Novel microstructural findings in M. plantaris and their impact during active and passive loading at the macro level.

Abstract:

:There are several studies dealing with experimental and structural analyses of skeletal muscles that are aimed at gaining a better understanding of three-dimensional muscle deformation and force generation. A variety of these contributions have performed structural or mechanical analyses, but very few have combined these approaches at different levels. To fill this gap, the present study aims to bring together three-dimensional micro-structural and mechanical findings in rabbit M. plantaris to study load transfer mechanisms inside the muscle during passive loading and active muscle contraction. During these two deformation states, the three-dimensional surface of the aponeurosis-tendon complex was recorded using optical measurement systems. In this way, the strain distribution on the muscle can be calculated to interpret the load transfer mechanisms inside the muscle. The results show that the three-dimensional strain distribution during muscle activation is completely different from the distribution during passive loading. Under both loading conditions, the strain distribution is irregular. To interpret these findings, the gross try and the fascicle architecture of the M. plantaris were determined. In doing so, a highly complex microstructure featuring tube- and sail-like structure was identified. Moreover, a compartmentalisation of the muscle into two compartments was detected. The smaller, bipennated muscle compartment was embedded into the larger, unipennated compartment. To the authors' knowledge, this type of inner structure has never been previously documented in single-headed muscles.

authors

Böl M,Leichsenring K,Ernst M,Wick C,Blickhan R,Siebert T

doi

10.1016/j.jmbbm.2015.06.026

subject

Has Abstract

pub_date

2015-11-01 00:00:00

pages

25-39

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(15)00231-3

journal_volume

51

pub_type

杂志文章
  • Relationships between the morphology, swelling and mechanical properties of poly(dimethyl siloxane)/poly(acrylic acid) interpenetrating networks.

    abstract::A limitation in the use of hydrophilic polymers as implantable devices is their inherently poor mechanical strength. Using interpenetrating polymer networks (IPNs) consisting of both hydrophilic and hydrophobic networks is an effective method of strengthening these polymers. In this work, a series of poly(dimethyl sil...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.01.002

    authors: Jalili K,Abbasi F,Oskoee SS,Alinejad Z

    更新日期:2009-10-01 00:00:00

  • Advances in zirconia toughened alumina biomaterials for total joint replacement.

    abstract::The objective of this article is to provide an up-to-date overview of zirconia-toughened alumina (ZTA) components used in total hip arthroplasties. The structure, mechanical properties, and available data regarding the clinical performance of ZTA are summarized. The advancements that have been made in understanding th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2013.03.022

    authors: Kurtz SM,Kocagöz S,Arnholt C,Huet R,Ueno M,Walter WL

    更新日期:2014-03-01 00:00:00

  • A numerical-experimental protocol to characterize corneal tissue with an application to predict astigmatic keratotomy surgery.

    abstract::Tonometers are intended to determine the intraocular pressure (IOP) and the quality of corneal tissue. In contrast to the physiological state of stress of the cornea, tonometers induce non-physiological bending stress. Recently, the use of a single experiment to calibrate a set of corneal mechanical properties was sug...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.06.017

    authors: Ariza-Gracia MÁ,Ortillés Á,Cristóbal JÁ,Rodríguez Matas JF,Calvo B

    更新日期:2017-10-01 00:00:00

  • Anatomic variation in the elastic anisotropy of cortical bone tissue in the human femur.

    abstract::Experimental investigations for anatomic variation in the magnitude and anisotropy of elastic constants in human femoral cortical bone tissue have typically focused on a limited number of convenient sites near the mid-diaphysis. However, the proximal and distal ends of the diaphysis are more clinically relevant to com...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.08.005

    authors: Espinoza Orías AA,Deuerling JM,Landrigan MD,Renaud JE,Roeder RK

    更新日期:2009-07-01 00:00:00

  • Strain rate influence on human cortical bone toughness: A comparative study of four paired anatomical sites.

    abstract::Bone fracture is a major health issue worldwide and consequently there have been extensive investigations into the fracture behavior of human cortical bone. However, the fracture properties of human cortical bone under fall-like loading conditions remains poorly documented. Further, most published research has been pe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.015

    authors: Gauthier R,Follet H,Langer M,Meille S,Chevalier J,Rongiéras F,Peyrin F,Mitton D

    更新日期:2017-07-01 00:00:00

  • Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta.

    abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.024

    authors: Peña JA,Martínez MA,Peña E

    更新日期:2015-10-01 00:00:00

  • Mechanical characterization of oligo(ethylene glycol)-based hydrogels by dynamic nanoindentation experiments.

    abstract::Oligo(ethylene glycol)-based (OEG) hydrogel samples of varying cross-link densities and degrees of swelling were characterized through dynamic nanoindentation testing. Experiments were performed using a non-standard nanoindentation method, which was validated on a standard polystyrene sample. This method maximizes the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.009

    authors: Guglielmi PO,Herbert EG,Tartivel L,Behl M,Lendlein A,Huber N,Lilleodden ET

    更新日期:2015-06-01 00:00:00

  • Molecular dynamics simulation of mechanical behavior of osteopontin-hydroxyapatite interfaces.

    abstract::Bone is characterized with an optimized combination of high stiffness and toughness. The understanding of bone nanomechanics is critical to the development of new artificial biological materials with unique properties. In this work, the mechanical characteristics of the interfaces between osteopontin (OPN, a noncollag...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.04.002

    authors: Lai ZB,Wang M,Yan C,Oloyede A

    更新日期:2014-08-01 00:00:00

  • Understanding how reduced loading affects Achilles tendon mechanical properties using a fibre-reinforced poro-visco-hyper-elastic model.

    abstract::Understanding tendon mechanobiology is important for gaining insight into the development of tendon pathology and subsequent repair processes. The aim of this study was to investigate how experimentally observed mechanobiological adaptation of rat Achilles tendons translate to changes in constitutive mechanical proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.041

    authors: Notermans T,Khayyeri H,Isaksson H

    更新日期:2019-08-01 00:00:00

  • Nanomechanical properties of human skin and introduction of a novel hair indenter.

    abstract::The mechanical resistance of the stratum corneum, the outermost layer of skin, to deformation has been evaluated at different length scales using Atomic Force Microscopy. Nanomechanical surface mapping was first conducted using a sharp silicon tip and revealed that Young׳s modulus of the stratum corneum varied over th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.014

    authors: Álvarez-Asencio R,Wallqvist V,Kjellin M,Rutland MW,Camacho A,Nordgren N,Luengo GS

    更新日期:2016-02-01 00:00:00

  • Unusual effect evidenced at the investigations of the mechanical behavior of composite hydrogels under cyclic compression.

    abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.030

    authors: Gofman IV,Buyanov AL

    更新日期:2017-07-01 00:00:00

  • Analysis of behind the armor ballistic trauma.

    abstract::The impact response of body armor composed of a ceramic plate with an ultrahigh molecular weight polyethylene (UHMWPE) fiber-reinforced composite and layers of UHMWPE fibers shielding a block of ballistic gelatin has been experimentally and numerically analyzed. It is a surrogate model for studying injuries to human t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.010

    authors: Wen Y,Xu C,Wang S,Batra RC

    更新日期:2015-05-01 00:00:00

  • Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.010

    authors: Murr LE,Amato KN,Li SJ,Tian YX,Cheng XY,Gaytan SM,Martinez E,Shindo PW,Medina F,Wicker RB

    更新日期:2011-10-01 00:00:00

  • Sub-10-micrometer toughening and crack tip toughness of dental enamel.

    abstract::In previous studies, enamel showed indications to occlude small cracks in-vivo and exhibited R-curve behaviors for bigger cracks ex-vivo. This study quantifies the crack tip's toughness (K(I0),K(III0)), the crack's closure stress and the cohesive zone size at the crack tip of enamel and investigates the toughening mec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.003

    authors: Ang SF,Schulz A,Pacher Fernandes R,Schneider GA

    更新日期:2011-04-01 00:00:00

  • Numerical modeling of bone as a multiscale poroelastic material by the homogenization technique.

    abstract::Bone is a complex material showing a hierarchical and porous structure but also a natural ability to remodel thanks to cells sensitive to fluid flows. Based on these characteristics, a multiscale numerical model has been developed in order to represent the bone response under mechanical solicitation. It relies on the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.015

    authors: Perrin E,Bou-Saïd B,Massi F

    更新日期:2019-03-01 00:00:00

  • Optimization of process parameters for drilled hole quality characteristics during cortical bone drilling using Taguchi method.

    abstract::Orthopaedic surgery involves drilling of bones to get them fixed at their original position. The drilling process used in orthopaedic surgery is most likely to the mechanical drilling process and there is all likelihood that it may harm the already damaged bone, the surrounding bone tissue and nerves, and the peril is...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.015

    authors: Singh G,Jain V,Gupta D,Ghai A

    更新日期:2016-09-01 00:00:00

  • De novo topology optimization of total ossicular replacement prostheses.

    abstract::Conductive hearing loss, due to middle ear pathologies or traumas, affects more than 5% of the population worldwide. Passive prostheses to replace the ossicular chain mainly rely on piston-like titanium and/or hydroxyapatite devices, which in the long term suffer from extrusion. Although the basic shape of such device...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103541

    authors: Milazzo M,Muyshondt PGG,Carstensen J,Dirckx JJJ,Danti S,Buehler MJ

    更新日期:2020-03-01 00:00:00

  • Comparison of microsphere penetration with LC Bead LUMI™ versus other commercial microspheres.

    abstract::The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.10.034

    authors: Caine M,Zhang X,Hill M,Guo W,Ashrafi K,Bascal Z,Kilpatrick H,Dunn A,Grey D,Bushby R,Bushby A,Willis SL,Dreher MR,Lewis AL

    更新日期:2018-02-01 00:00:00

  • In vivo assessment of material properties of muscles and connective tissues around the knee joint based on shear wave elastography.

    abstract::Previous studies on knee biomechanics have mainly focused on the joint structure itself, largely neglecting the material properties of the muscles and connective tissues around the knee joint. Therefore, this study was purposed to conduct a systematic in vivo examination of the material properties of muscles, tendons,...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103829

    authors: Wu J,Qian Z,Liang W,Liu J,Ren L,Ren L

    更新日期:2020-09-01 00:00:00

  • Composite electrospun gelatin fiber-alginate gel scaffolds for mechanically robust tissue engineered cornea.

    abstract::A severe shortage of good quality donor cornea is now an international crisis in public health. Alternatives for donor tissue need to be urgently developed to meet the increasing demand for corneal transplantation. Hydrogels have been widely used as scaffolds for corneal tissue regeneration due to their large water co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.001

    authors: Tonsomboon K,Oyen ML

    更新日期:2013-05-01 00:00:00

  • Mechanical properties enhancement of self-cured PMMA reinforced with zirconia and boron nitride nanopowders for high-performance dental materials.

    abstract::We report on the mechanical properties regarding self-cured acrylic polymethyl methacrylate (PMMA) reinforced with hexagonal boron nitride (h-BN) and stabilized zirconia (8Y ZrO2) nanopowders. The nanocomposites were prepared by using both manual and ultrasonic mixing techniques. The fabricated specimens were subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103937

    authors: Alqahtani M

    更新日期:2020-10-01 00:00:00

  • A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    abstract::A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.022

    authors: Abdelgaied A,Fisher J,Jennings LM

    更新日期:2018-02-01 00:00:00

  • Study on the effect of graphene oxide (GO) feeding on silk properties based on segmented precise measurement.

    abstract::Silk is widely used in the biomedical field (e.g., surgical sutures) for its excellent mechanical properties and biocompatibility. The properties of silk can be further enhanced by a multitude of methods, including nano particle feeding, which is convenient and green. Generally, the filament length of a silkworm cocoo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104147

    authors: Qu J,Dai M,Ye W,Fang Y,Bian D,Su W,Li F,Sun H,Wei J,Li B

    更新日期:2021-01-01 00:00:00

  • Teleost fish scales amongst the toughest collagenous materials.

    abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.09.025

    authors: Khayer Dastjerdi A,Barthelat F

    更新日期:2015-12-01 00:00:00

  • The effect of equiaxial stretching on the osteogenic differentiation and mechanical properties of human adipose stem cells.

    abstract::Although mechanical cues are known to affect stem cell fate and mechanobiology, the significance of such stimuli on the osteogenic differentiation of human adipose stem cells (hASCs) remains unclear. In this study, we investigated the effect of long-term mechanical stimulation on the attachment, osteogenic differentia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.016

    authors: Virjula S,Zhao F,Leivo J,Vanhatupa S,Kreutzer J,Vaughan TJ,Honkala AM,Viehrig M,Mullen CA,Kallio P,McNamara LM,Miettinen S

    更新日期:2017-08-01 00:00:00

  • A constitutive law for degrading bioresorbable polymers.

    abstract::This paper presents a constitutive law that predicts the changes in elastic moduli, Poisson's ratio and ultimate tensile strength of bioresorbable polymers due to biodegradation. During biodegradation, long polymer chains are cleaved by hydrolysis reaction. For semi-crystalline polymers, the chain scissions also lead ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.026

    authors: Samami H,Pan J

    更新日期:2016-06-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Effect of hydroxyapatite fillers on the mechanical properties and osteogenesis capacity of bio-based polyurethane composite scaffolds.

    abstract::A newly designed hydroxyapatite-polyurethane (HA-PU) composite scaffold was prepared by polymerizing glyceride of castor oil (GCO) with isophorone diisocyanate (IPDI) and HA as fillers. The aim of this study was to determine the effect of HA fillers on the mechanical properties and osteogenesis capacity of the composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.08.028

    authors: Du J,Zuo Y,Lin L,Huang D,Niu L,Wei Y,Wang K,Lin Q,Zou Q,Li Y

    更新日期:2018-12-01 00:00:00

  • An experimental study to investigate biomechanical aspects of the initial stability of press-fit implants.

    abstract::Initial fixation of press-fit implants depends on interference fit, surface morphology, and bone material properties. To understand the biomechanical effect of each factor and their interactions, the pull-out strength of seven types of CoCrMo tapered implants, with four different interference fits, three different sur...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.014

    authors: Berahmani S,Janssen D,van Kessel S,Wolfson D,de Waal Malefijt M,Buma P,Verdonschot N

    更新日期:2015-02-01 00:00:00

  • Reproducibility assessment of ultrasound-based aortic stiffness quantification and verification using Bi-axial tensile testing.

    abstract::Current guidelines for abdominal aortic aneurysm (AAA) repair are primarily based on the maximum diameter. Since these methods lack robustness in decision making, new image-based methods for mechanical characterization have been proposed. Recently, time-resolved 3D ultrasound (4D US) in combination with finite element...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103571

    authors: van Disseldorp EMJ,van den Hoven MHMH,van de Vosse FN,van Sambeek MRHM,Lopata RGP

    更新日期:2020-03-01 00:00:00