An experimental study to investigate biomechanical aspects of the initial stability of press-fit implants.

Abstract:

:Initial fixation of press-fit implants depends on interference fit, surface morphology, and bone material properties. To understand the biomechanical effect of each factor and their interactions, the pull-out strength of seven types of CoCrMo tapered implants, with four different interference fits, three different surface morphologies (low, medium and high roughness), and at two time points (0 and 30 min) were tested in trabecular bone with varying density. The effect of interference fit on pull-out strength depended on the surface morphology and time. In contrast with our expectations, samples with a higher roughness had a lower pull-out strength. We found a similar magnitude of bone damage for the different surface morphologies, but the type of damage was different, with bone compaction versus bone abrasion for low and high frictional surfaces, respectively. This explains a reduced sensitivity of fixation strength to bone mineral density in the latter group. In addition, a reduction in fixation strength after a waiting period only occurred for the low frictional specimens. Our study demonstrates that it is essential to evaluate the interplay between different factors and emphasizes the importance of testing in natural bone in order to optimize the initial stability of press-fit implants.

authors

Berahmani S,Janssen D,van Kessel S,Wolfson D,de Waal Malefijt M,Buma P,Verdonschot N

doi

10.1016/j.jmbbm.2014.11.014

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

177-85

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(14)00366-X

journal_volume

42

pub_type

杂志文章
  • An interface finite element model can be used to predict healing outcome of bone fractures.

    abstract::After fractures, bone can experience different potential outcomes: successful bone consolidation, non-union and bone failure. Although, there are a lot of factors that influence fracture healing, experimental studies have shown that the interfragmentary movement (IFM) is one of the main regulators for the course of bo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.09.023

    authors: Alierta JA,Pérez MA,García-Aznar JM

    更新日期:2014-01-01 00:00:00

  • Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications.

    abstract::This work is part of an ongoing program to develop a new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite material for use as an orthopaedic long bone fracture plate, instead of a metal plate. The purpose of this study was to evaluate the mechanical properties of this new novel composite material. The composit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.013

    authors: Bagheri ZS,El Sawi I,Schemitsch EH,Zdero R,Bougherara H

    更新日期:2013-04-01 00:00:00

  • Resin adjustment of three-dimensional printed thermoset occlusal splints: Bonding properties - Short communication.

    abstract:OBJECTIVES:To evaluate the interfacial adhesion of an autopolymerizing acrylic resin to 3D printed thermoset occlusal splints compared to thermoplastic occlusal splints. MATERIALS AND METHODS:Cylinders made of an autopolymerizing acrylic resin were adhered to 3D printed thermoset and also to thermoplastic plates. A di...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.011

    authors: Perea-Lowery L,Vallittu PK

    更新日期:2019-07-01 00:00:00

  • Tribology and hydrophobicity of a biocompatible GPTMS/PFPE coating on Ti6Al4V surfaces.

    abstract::Tribological properties of perfluoropolyether (PFPE) coated 3-glycidoxypropyltrimethoxy silane (GPTMS) SAMs (self-assembled monolayers) onto Ti6Al4V alloy substrate were studied using ball-on-disk experiments. GPTMS SAMs deposition onto a Ti6Al4V alloy surface was carried out using solution phase method. Ultra-thin la...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.06.016

    authors: Panjwani B,Sinha SK

    更新日期:2012-11-01 00:00:00

  • Fabrication, tribological and corrosion behaviors of ultra-fine grained Co-28Cr-6Mo alloy for biomedical applications.

    abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.039

    authors: Ren F,Zhu W,Chu K

    更新日期:2016-07-01 00:00:00

  • In-situ synthesis of AgNPs in the natural/synthetic hybrid nanofibrous scaffolds: Fabrication, characterization and antimicrobial activities.

    abstract::Silver nanoparticles embedded within a nanofibrous polymer matrix have significant attention in recent years as an antimicrobial wound dressing materials. Herein, we have fabricated a novel Ag-polyurethane-zein hybrid nanofibrous scaffold for wound dressing applications. AgNPs were synthesized in-situ via reduction of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.07.034

    authors: Maharjan B,Joshi MK,Tiwari AP,Park CH,Kim CS

    更新日期:2017-01-01 00:00:00

  • Experimental study on dieless drawing of Nickel-Titanium alloy.

    abstract::The effect of a dieless drawing process on commercial grade Nickel-Titanium rods, of 5 mm diameter, was investigated by varying the established critical process parameters of temperature, cooling rate, drawing velocity, and heating/cooling velocity. The rods were successfully dieless drawn with a maximum steady state ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.013

    authors: Twohig E,Tiernan P,Tofail SA

    更新日期:2012-04-01 00:00:00

  • Packing of muscles in the rabbit shank influences three-dimensional architecture of M. soleus.

    abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.006

    authors: Wick C,Böl M,Müller F,Blickhan R,Siebert T

    更新日期:2018-07-01 00:00:00

  • Assessment of mechanical behavior of PLA composites reinforced with Mg micro-particles through depth-sensing indentations analysis.

    abstract::This work deals with the mechanical characterization by depth-sensing indentation (DSI) of PLLA and PLDA composites reinforced with micro-particles of Mg (up to 15wt%), which is a challenging task since the indented volume must provide information of the bulk composite, i.e. contain enough reinforcement particles. The...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.09.013

    authors: Cifuentes SC,Frutos E,Benavente R,Lorenzo V,González-Carrasco JL

    更新日期:2017-01-01 00:00:00

  • On the tension-compression switch hypothesis in arterial mechanics.

    abstract::The tension-compression switch hypothesis for soft tissue proposes that when collagen fibres are compressed they do not contribute to the mechanical response which is then assumed to be the isotropic response of the extra-cellular matrix in which they are embedded. Such an assumption would seem reasonable. However, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103558

    authors: Horgan CO,Murphy JG

    更新日期:2020-03-01 00:00:00

  • Elastic softening of β-type Ti-Nb alloys by indium (In) additions.

    abstract::Recent developments showed that β-type Ti-Nb alloys are good candidates for hard tissue replacement and repair. However, their elastic moduli are still to be further reduced to match Young׳s modulus values of human bone, in order to avoid stress shielding. In the present study, the effect of indium (In) additions on t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.010

    authors: Calin M,Helth A,Gutierrez Moreno JJ,Bönisch M,Brackmann V,Giebeler L,Gemming T,Lekka CE,Gebert A,Schnettler R,Eckert J

    更新日期:2014-11-01 00:00:00

  • Impact of the testing protocol on the mechanical characterization of small diameter electrospun vascular grafts.

    abstract:AIM:For the proper function of small diameter vascular grafts their mechanical properties are essential. A variety of testing methods and protocols exists to measure tensile strength, compliance and viscoelastic material behavior. In this study the impact of the measurement protocol in hoop tensile tests on the measure...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103652

    authors: Stoiber M,Grasl C,Frieberger K,Moscato F,Bergmeister H,Schima H

    更新日期:2020-04-01 00:00:00

  • Detection of degradation in polyester implants by analysing mode shapes of structure vibration.

    abstract::This paper presents a numerical study on using vibration analysis to detect degradation in degrading polyesters. A numerical model of a degrading plate sample is considered. The plate is assumed to degrade following the typical behaviour of amorphous copolymers of polylactide and polyglycolide. Due to the well-known a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.002

    authors: Samami H,Pan J

    更新日期:2016-09-01 00:00:00

  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • Mechanical and microstructural properties of ultra-translucent dental zirconia ceramic stabilized with 5 mol% yttria.

    abstract::Monolithic dental prostheses fabricated from 3 mol.% yttria-stabilized zirconia (3YZ) are becoming increasingly popular. Recently, 5 mol.% yttria-stabilized zirconia (5YZ) which significantly improves the translucency of 3YZ has been prepared. However, its mechanical and microstructural properties, especially those af...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103974

    authors: Harada A,Shishido S,Barkarmo S,Inagaki R,Kanno T,Örtengren U,Egusa H,Nakamura K

    更新日期:2020-11-01 00:00:00

  • Design of a remote-control drug delivery implantable chip for cancer local on demand therapy using ionic polymer metal composite actuator.

    abstract::Since the local, on demand, cancer therapy is a challenging clinical issue today, this paper presents the design, fabrication and characterization of a remotely controlled single reservoir drug delivery chip using Ionic Polymer Metal Composite (IPMC) actuator. Here, Drug release was externally programmed and controlle...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.034

    authors: Saneei Mousavi MS,Karami AH,Ghasemnejad M,Kolahdouz M,Manteghi F,Ataei F

    更新日期:2018-10-01 00:00:00

  • Elastic properties measurement of human enamel based on resonant ultrasound spectroscopy.

    abstract:OBJECTIVES:To investigate the elastic properties of human enamel using resonant ultrasound spectroscopy (RUS). METHODS:Six rectangular parallelepiped specimens were prepared from six human third molars. For all specimens, the theoretical resonant frequencies were calculated using the Rayleigh-Ritz method, knowing the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.09.014

    authors: Niu H,Fan F,Wang R,Zhang Q,Shen F,Ren P,Liu T,Fan Y,Laugier P

    更新日期:2019-01-01 00:00:00

  • Processing nanoengineered scaffolds through electrospinning and mineralization suitable for biomimetic bone tissue engineering.

    abstract::Processing scaffolds that mimic the extracellular matrix (ECM) of natural bone in structure and chemical composition is a potential promising option for engineering physiologically functional bone tissue. In this article, we report a novel method, by combining electrospinning and mineralization, to process a series of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.01.007

    authors: Liao S,Murugan R,Chan CK,Ramakrishna S

    更新日期:2008-07-01 00:00:00

  • Bioactive composite for keratoprosthesis skirt.

    abstract::In this study, the fabrication and properties of a synthetic keratoprosthesis skirt for use in osteo-odonto-keratoprosthesis (OOKP) surgery are discussed. In the search for a new material concept, bioactive glass and polymethyl methacrylate (PMMA)-based composites were prepared. Three different bioactive glasses (i.e....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.025

    authors: Laattala K,Huhtinen R,Puska M,Arstila H,Hupa L,Kellomäki M,Vallittu PK

    更新日期:2011-11-01 00:00:00

  • Optimization of process parameters for drilled hole quality characteristics during cortical bone drilling using Taguchi method.

    abstract::Orthopaedic surgery involves drilling of bones to get them fixed at their original position. The drilling process used in orthopaedic surgery is most likely to the mechanical drilling process and there is all likelihood that it may harm the already damaged bone, the surrounding bone tissue and nerves, and the peril is...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.015

    authors: Singh G,Jain V,Gupta D,Ghai A

    更新日期:2016-09-01 00:00:00

  • Evaluation of the mechanical properties and degree of conversion of 3D printed splint material.

    abstract:OBJECTIVE:To evaluate the effect of post-curing method, printing layer thickness, and water storage on the mechanical properties and degree of conversion of a light-curing methacrylate based resin material (IMPRIMO® LC Splint), used for the fabrication of 3D printed occlusal splints and surgical guides. METHODS:96 bar...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104254

    authors: Perea-Lowery L,Gibreel M,Vallittu PK,Lassila L

    更新日期:2021-03-01 00:00:00

  • A comparative study of the mechanical properties of a dinosaur and crocodile fossil teeth.

    abstract::Vertebrate teeth are complex structures adapted in terms of shape and structure to serve a variety of functions like biting and grinding. Thus, examining the morphology, composition and mechanical properties of the teeth can aid in providing insights into the feeding behaviour of extinct species. We here provide the f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.025

    authors: Kundanati L,D'Incau M,Bernardi M,Scardi P,Pugno NM

    更新日期:2019-09-01 00:00:00

  • The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    abstract::The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.005

    authors: Maru MM,Amaral M,Rodrigues SP,Santos R,Gouvea CP,Archanjo BS,Trommer RM,Oliveira FJ,Silva RF,Achete CA

    更新日期:2015-09-01 00:00:00

  • Thermal-stress analysis of ceramic laminate veneer restorations with different incisal preparations using micro-computed tomography-based 3D finite element models.

    abstract::Main objective of this study is to investigate the thermal behavior of ceramic laminate veneer restorations of the maxillary central incisor with different incisal preparations such as butt joint and palatinal chamfer using finite element method. In addition, it is also aimed to understand the effect of different ther...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.039

    authors: Celebi AT,Icer E,Eren MM,Baykasoglu C,Mugan A,Yildiz E

    更新日期:2017-11-01 00:00:00

  • Experimental and constitutive modeling approaches for a study of biomechanical properties of human coronary arteries.

    abstract::The study concerns the determination of mechanical properties of human coronary arterial walls with both experimental and constitutive modeling approaches. The research material was harvested from 18 patients (range 50-84 years). On the basis of hospital records and visual observation, each tissue sample was classifie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.021

    authors: Jankowska MA,Bartkowiak-Jowsa M,Bedzinski R

    更新日期:2015-10-01 00:00:00

  • Human enamel rod presents anisotropic nanotribological properties.

    abstract::The AFM combined nanoindentation was performed to observe the ultrastructure of enamel rod from various section plans and positions while probing their mechanical and tribological properties of the area. The nanohardness and the elastic modulus of the head region of the enamel rods are significantly higher than that o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.002

    authors: Jeng YR,Lin TT,Hsu HM,Chang HJ,Shieh DB

    更新日期:2011-05-01 00:00:00

  • Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading.

    abstract::This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.005

    authors: Ozcan M,Melo RM,Souza RO,Machado JP,Felipe Valandro L,Botttino MA

    更新日期:2013-04-01 00:00:00

  • Multiscale FE method for analysis of bone micro-structures.

    abstract::Bones are composed of hierarchical bio-composite materials characterized by complex multiscale structural geometry and behavior. The architecture and the mechanical properties of bone tissue differ at each level of hierarchy. Thus, a multiscale approach for mechanical analysis of bone is imperative. This paper propose...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.03.003

    authors: Podshivalov L,Fischer A,Bar-Yoseph PZ

    更新日期:2011-08-01 00:00:00

  • Quantifying tactile properties of liver tissue, silicone elastomers, and a 3D printed polymer for manufacturing realistic organ models.

    abstract::In order to produce anatomical models that feel realistic to the touch, artificial materials need to be found that mimic tactile properties of biological tissues. The aim of this study was to provide a guideline for identifying materials that feel similar to biological tissues, based on a quantifiable and reproducible...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103630

    authors: Estermann SJ,Pahr DH,Reisinger A

    更新日期:2020-04-01 00:00:00

  • Analysis of the mechanical response of biomimetic materials with highly oriented microstructures through 3D printing, mechanical testing and modeling.

    abstract::Many biomineralized organisms have evolved highly oriented nanostructures to perform specific functions. One key example is the abrasion-resistant rod-like microstructure found in the radular teeth of Chitons (Cryptochiton stelleri), a large mollusk. The teeth consist of a soft core and a hard shell that is abrasion r...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.026

    authors: de Obaldia EE,Jeong C,Grunenfelder LK,Kisailus D,Zavattieri P

    更新日期:2015-08-01 00:00:00