Abstract:
:Current guidelines for abdominal aortic aneurysm (AAA) repair are primarily based on the maximum diameter. Since these methods lack robustness in decision making, new image-based methods for mechanical characterization have been proposed. Recently, time-resolved 3D ultrasound (4D US) in combination with finite element analysis was shown to provide additional risk estimators such as patient-specific peak wall stresses and wall stiffness in a non-invasive way. The aim of this study is to: 1) assess the reproducibility of this US-based stiffness measurement in vitro and in vivo, and 2) verify this 4D US stiffness using the gold standard: bi-axial tensile testing of the excised aortic tissue. For the in vitro study, 4D US data were acquired in an idealized inflation experiment using porcine aortas. The full aortic geometry was segmented and tracked over the cardiac cycle, and afterwards finite element analysis was performed by calibrating the finite element model to the measured US displacements to find the global aortic wall stiffness. For verification purposes, the porcine tissue was subjected to bi-axial tensile testing. Secondly, four AAA patients were included and 4D US data were acquired before open aortic surgery was performed. Similar to the experimental approach, the 4D US data were analyzed using the iterative finite element approach. During surgery, aortic tissue was harvested and the resulting tissue specimens were analyzed using bi-axial tensile testing. Finally, reproducibility was quantified for both methods. A high reproducibility was observed for the wall stiffness measurements using 4D US, i.e., an ICC of 0.91 (95% CI: 0.78-0.98) for the porcine aortas and an ICC of 0.98 (95% CI: 0.84-1.00) for the AAA samples. Verification with bi-axial tensile testing revealed a good agreement for the inflation experiment and a moderate agreement for the AAA patients, partially caused by the diseased state and inhomogeneities of the tissue. The performance of aortic stiffness characterization using 4D US revealed overall a high reproducibility and a moderate agreement with ex vivo mechanical testing. Future research should include more patient samples, to statistically assess the accuracy of the current in vivo method, which is not trivial due to the low number of open surgical interventions.
journal_name
J Mech Behav Biomed Materauthors
van Disseldorp EMJ,van den Hoven MHMH,van de Vosse FN,van Sambeek MRHM,Lopata RGPdoi
10.1016/j.jmbbm.2019.103571subject
Has Abstractpub_date
2020-03-01 00:00:00pages
103571eissn
1751-6161issn
1878-0180pii
S1751-6161(18)31702-8journal_volume
103pub_type
杂志文章abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.06.006
更新日期:2013-11-01 00:00:00
abstract::Previous physiological experiments and finite element modelling indicate that inter-synergistic epimuscular myofascial force transmission (EMFT) between co-activated muscles has a potential to affect healthy muscle's contribution to joint moment and joint range of movement. This is quite relevant for patients with cer...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.08.040
更新日期:2018-01-01 00:00:00
abstract::In this study, we explored the Ti-Nb-Fe system to find an optimal cost-effective composition with the lowest elastic modulus and the lowest added Nb content. Six Ti-(31-4x)Nb-(1+0.5x)Fe ingots were prepared and Nb was substituted with Fe, starting at Ti-31Nb-1.0Fe and going up to Ti-11Nb-3.5Fe (wt%). The ingots were s...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.09.024
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVE:This study examined the effect of phytic acid (IP6) in stabilizing the morphology of dentine collagen network and resin-dentine bonding. METHODS:Dentine beams were fully demineralized with 10% phosphoric acid (PA) or 1% IP6 (pH 1.2). PA-demineralized beams were divided into three groups: (a) no further treat...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.03.027
更新日期:2015-08-01 00:00:00
abstract::The structure, composition and morphology of a radio-frequency (RF) magnetron sputter-deposited dense nano-hydroxyapatite (HA) coating that was deposited on the surface of an AZ31 magnesium alloy were characterized using AFM, SEM, EDX and XRD. The results obtained from SEM and XRD experiments revealed that the bias ap...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.02.025
更新日期:2015-06-01 00:00:00
abstract::In this study, the bone mineral density (BMD), geometry, macroscopic viscoelastic properties and mechanical strength in five different groups of Sprague-Dawley rats (sham operated, ovariectomized with vehicle, parathyroid hormone and/or ibandronate administration) were examined by peripheral quantitative computed tomo...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.03.009
更新日期:2013-06-01 00:00:00
abstract::Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.01.007
更新日期:2014-06-01 00:00:00
abstract::The passive micro-structural mechanical response of muscle tissue is important for numerous medical applications. However, the recently observed tension/compression asymmetry in porcine muscle remains poorly explained. In particular there remains a lack of understanding of how external tension or compression applied i...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.08.019
更新日期:2014-12-01 00:00:00
abstract::Total Knee Arthroplasty is a well-established surgical procedure performed to relieve pain and to restore function in knee osteoarthritis. A proper choice of the implant size is mandatory in order to guarantee the success of the implant and to respect the bone stock of tibial plateau and femoral condyles. The aim of t...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.06.012
更新日期:2014-10-01 00:00:00
abstract::The impact response of body armor composed of a ceramic plate with an ultrahigh molecular weight polyethylene (UHMWPE) fiber-reinforced composite and layers of UHMWPE fibers shielding a block of ballistic gelatin has been experimentally and numerically analyzed. It is a surrogate model for studying injuries to human t...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.01.010
更新日期:2015-05-01 00:00:00
abstract::The medial patello-femoral ligament is considered the most important passive patellar stabilizer and its proper functionality is essential for the patello-femoral joint stability. In this work, 18 human knees were randomly divided into two groups and reconstructed through two different surgical techniques: the "Throug...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.02.009
更新日期:2016-06-01 00:00:00
abstract::The paper describes a highly space-resolved characterization of the surface mechanical properties of the posterior human corneal layer (Descemet's membrane). This has been accomplished with Atomic Force Microscopy (AFM) nano-indentation by using a probe with a sharp tip geometry. Results indicate that the contact with...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.05.019
更新日期:2017-10-01 00:00:00
abstract::Processing scaffolds that mimic the extracellular matrix (ECM) of natural bone in structure and chemical composition is a potential promising option for engineering physiologically functional bone tissue. In this article, we report a novel method, by combining electrospinning and mineralization, to process a series of...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.01.007
更新日期:2008-07-01 00:00:00
abstract::Orthopedic interfaces such as the tendon-bone junction (TBJ) present unique challenges for biomaterials development. Here we describe a multi-compartment collagen-GAG scaffold fabricated via lyophilization that contains discrete mineralized (CGCaP) and non-mineralized (CG) regions joined by a continuous interface. Mod...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.07.016
更新日期:2013-12-01 00:00:00
abstract::Infection incidence for total hip and knee arthroplasty (THA and TKA, respectively) is between 0.2% and 5% and results in approximately 100,000 device failures per year in the United States. Treatment requires prolonged systemic antibiotic therapy with additional surgical revisions. As a prophylactic measure against i...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.06.033
更新日期:2018-11-01 00:00:00
abstract::Superelastic wires and diamond-shaped stent surrogates were manufactured from Nitinol rods and tubing, respectively, from five different mill product suppliers - Standard VAR, Standard VIM, Standard VIM+VAR, Process-Optimized VIM+VAR, and High-Purity VAR. High-cycle fatigue tests up to 10(7) cycles were conducted unde...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.07.003
更新日期:2015-11-01 00:00:00
abstract::Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.04.005
更新日期:2017-08-01 00:00:00
abstract::Biocompatible polymers are commonly used to fabricate microfluidic channels for the study of biological flows such as blood microflows. The most common of these materials is polydimethylsiloxane (PDMS) which is very hydrophobic. Oxygenated plasma is advocated to treat the PDMS with reported decreases in contact angle ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.07.007
更新日期:2013-01-01 00:00:00
abstract::In total hip replacement (THR), wear particles play a significant role in osteolysis and have been observed in locations as remote as the tip of femoral stem. However, there is no clear understanding of the factors and mechanisms causing, or contributing to particle migration to the periprosthetic tissue. Interfacial ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.01.005
更新日期:2014-04-01 00:00:00
abstract::The scaled skin of fish is an intricate system that provides mechanical protection against hard and sharp puncture, while maintaining the high flexural compliance required for unhindered locomotion. This unusual combination of local hardness and global compliance makes fish skin an interesting model for bioinspired pr...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.06.014
更新日期:2017-12-01 00:00:00
abstract::This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars we...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103401
更新日期:2019-12-01 00:00:00
abstract::Oligo(ethylene glycol)-based (OEG) hydrogel samples of varying cross-link densities and degrees of swelling were characterized through dynamic nanoindentation testing. Experiments were performed using a non-standard nanoindentation method, which was validated on a standard polystyrene sample. This method maximizes the...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.02.009
更新日期:2015-06-01 00:00:00
abstract::The present study describes the lubrication mechanisms within artificial hip joints considering real conformity of rubbing surfaces. Part I is focused on hard-on-soft material combination, introducing the fundamentals of lubrication performance. These pairs have not been explored in terms of in situ observation before...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.09.022
更新日期:2019-01-01 00:00:00
abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.05.024
更新日期:2015-10-01 00:00:00
abstract::Hemipelvic prostheses are used to reconstruct the damaged pelvis due to bone tumors and traumas. However, biomechanical properties of the reconstructed pelvis remain unclear, causing difficulties to implant development and prediction of surgical outcome. In this study, a novel adjustable hemipelvic prosthesis for the ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.10.036
更新日期:2019-02-01 00:00:00
abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.09.025
更新日期:2015-12-01 00:00:00
abstract::Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.07.018
更新日期:2018-11-01 00:00:00
abstract::Polylactic acid (PLA), one of the most likely green and environmentally friendly materials, is an alternative to petroleum-based plastic. It still remains a challenge to increase the degradation rate and decrease the cost of PLA without compromised mechanical properties. Low cost PLA/wood flour (WF) composite was elab...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.08.016
更新日期:2018-12-01 00:00:00
abstract::The age-related deterioration in the quality (e.g., strength and fracture resistance) and quantity (e.g., bone-mineral density) of human bone, together with increased life expectancy, is responsible for increasing incidence of bone fracture in the elderly. The present study describes ex vivo fracture experiments to qu...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.020
更新日期:2011-10-01 00:00:00
abstract::Geometric confinement to the nanoscale, a concept that refers to the characteristic dimensions of structural features of materials at this length scale, has been shown to control the mechanical behavior of many biological materials or their building blocks, and such effects have also been suggested to play a crucial r...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.12.005
更新日期:2013-04-01 00:00:00