Optimization of process parameters for drilled hole quality characteristics during cortical bone drilling using Taguchi method.

Abstract:

:Orthopaedic surgery involves drilling of bones to get them fixed at their original position. The drilling process used in orthopaedic surgery is most likely to the mechanical drilling process and there is all likelihood that it may harm the already damaged bone, the surrounding bone tissue and nerves, and the peril is not limited at that. It is very much feared that the recovery of that part may be impeded so that it may not be able to sustain life long. To achieve sustainable orthopaedic surgery, a surgeon must try to control the drilling damage at the time of bone drilling. The area around the holes decides the life of bone joint and so, the contiguous area of drilled hole must be intact and retain its properties even after drilling. This study mainly focuses on optimization of drilling parameters like rotational speed, feed rate and the type of tool at three levels each used by Taguchi optimization for surface roughness and material removal rate. The confirmation experiments were also carried out and results found with the confidence interval. Scanning electrode microscopy (SEM) images assisted in getting the micro level information of bone damage.

authors

Singh G,Jain V,Gupta D,Ghai A

doi

10.1016/j.jmbbm.2016.05.015

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

355-365

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(16)30134-5

journal_volume

62

pub_type

杂志文章
  • Fatigue and durability of Nitinol stents.

    abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.08.001

    authors: Pelton AR,Schroeder V,Mitchell MR,Gong XY,Barney M,Robertson SW

    更新日期:2008-04-01 00:00:00

  • Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening.

    abstract::Many treatments for cardiovascular diseases include an endovascular insertion of stents or stent grafts into arteries, a procedure which may cause high tissue stresses and even damage in the arterial wall. In order to study such problems by using finite element methods, both appropriate constitutive models and experim...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.03.012

    authors: Weisbecker H,Pierce DM,Regitnig P,Holzapfel GA

    更新日期:2012-08-01 00:00:00

  • Dynamic nanomechanical properties of novel Si-rich intermetallic coatings growth on a medical 316 LVM steel by hot dipping in a hypereutectic Al-25Si alloy.

    abstract::This aim of this study is to determine the elastoplastic properties of Ni-free Al3FeSi2 intermetallic coatings grown on medical stainless steel under different experimental conditions. Elastoplastic properties are defined by the plasticity index (PI), which correlates the hardness and the Young's modulus. Special emph...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.018

    authors: Frutos E,González-Carrasco JL

    更新日期:2015-06-01 00:00:00

  • Stem cell therapy restores viscoelastic properties of myocardium in rat model of hypertension.

    abstract::Extensive remodeling of the myocardium is seen in a variety of cardiovascular diseases, including systemic hypertension. Stem cell therapy has been proposed to improve the clinical outcomes of hypertension, and we hypothesized that changes in mechanical properties of the myocardium would accompany the progression of d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.041

    authors: Rubiano A,Qi Y,Guzzo D,Rathinasabapathy A,Rowe K,Pepine C,Simmons C

    更新日期:2016-06-01 00:00:00

  • Air-abrasion using new silica-alumina powders containing different silica concentrations: Effect on the microstructural characteristics and fatigue behavior of a Y-TZP ceramic.

    abstract::This study assessed the fatigue performance (biaxial flexure fatigue strength), surface characteristics (topography and roughness) and structural stability (t-m phase transformation) of a Y-TZP ceramic subjected to air-abrasion using new powders (7% and 20% silica-coated aluminum oxide particles) in comparison to comm...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.032

    authors: Cadore-Rodrigues AC,Prochnow C,Rippe MP,Oliveira JS,Jahn SL,Foletto EL,Pereira GKR,Valandro LF

    更新日期:2019-10-01 00:00:00

  • Elastic properties measurement of human enamel based on resonant ultrasound spectroscopy.

    abstract:OBJECTIVES:To investigate the elastic properties of human enamel using resonant ultrasound spectroscopy (RUS). METHODS:Six rectangular parallelepiped specimens were prepared from six human third molars. For all specimens, the theoretical resonant frequencies were calculated using the Rayleigh-Ritz method, knowing the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.09.014

    authors: Niu H,Fan F,Wang R,Zhang Q,Shen F,Ren P,Liu T,Fan Y,Laugier P

    更新日期:2019-01-01 00:00:00

  • Towards intervertebral disc engineering: Bio-mimetics of form and function of the annulus fibrosus lamellae.

    abstract::The aging western society is heavily afflicted with intervertebral disc (IVD) degeneration. Replacement or repair of the degenerated IVD with an artificial bio-mimetic construct is one of the challenges of future research due to its complex structure and unique biomechanical function. Herein, biocomposite laminates ma...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.023

    authors: Sharabi M,Wertheimer S,Wade KR,Galbusera F,Benayahu D,Wilke HJ,Haj-Ali R

    更新日期:2019-06-01 00:00:00

  • Understanding how reduced loading affects Achilles tendon mechanical properties using a fibre-reinforced poro-visco-hyper-elastic model.

    abstract::Understanding tendon mechanobiology is important for gaining insight into the development of tendon pathology and subsequent repair processes. The aim of this study was to investigate how experimentally observed mechanobiological adaptation of rat Achilles tendons translate to changes in constitutive mechanical proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.041

    authors: Notermans T,Khayyeri H,Isaksson H

    更新日期:2019-08-01 00:00:00

  • Effects of inter-synergistic mechanical interactions on the mechanical behaviour of activated spastic semitendinosus muscle of patients with cerebral palsy.

    abstract::Previous physiological experiments and finite element modelling indicate that inter-synergistic epimuscular myofascial force transmission (EMFT) between co-activated muscles has a potential to affect healthy muscle's contribution to joint moment and joint range of movement. This is quite relevant for patients with cer...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.040

    authors: Kaya CS,Temelli Y,Ates F,Yucesoy CA

    更新日期:2018-01-01 00:00:00

  • Influence of cold rolling and ageing treatment on microstructure and mechanical properties of Ti-30Nb-5Ta-6Zr alloy.

    abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.06.006

    authors: Wang Y,Zhao J,Dai S,Chen F,Yu X,Zhang Y

    更新日期:2013-11-01 00:00:00

  • Assessment of a long-term in vitro model to characterize the mechanical behavior and macrophage-mediated degradation of a novel, degradable, electrospun poly-urethane vascular graft.

    abstract::An assessment tool to evaluate the degradation of biodegradable materials in a more physiological environment is still needed. Macrophages are critical players in host response, remodeling and degradation. In this study, a cell culture model using monocyte-derived primary macrophages was established to study the degra...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104077

    authors: Enayati M,Puchhammer S,Iturri J,Grasl C,Kaun C,Baudis S,Walter I,Schima H,Liska R,Wojta J,Toca-Herrera JL,Podesser BK,Bergmeister H

    更新日期:2020-12-01 00:00:00

  • Mechanical performance, corrosion and tribological evaluation of a Co-Cr-Mo alloy processed by MIM for biomedical applications.

    abstract::In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co-Cr-Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103706

    authors: Herranz G,Berges C,Naranjo JA,García C,Garrido I

    更新日期:2020-05-01 00:00:00

  • Nanoscale characterization of dynamic cellular viscoelasticity by atomic force microscopy with varying measurement parameters.

    abstract::Cell mechanics plays an important role in regulating the physiological activities of cells. The advent of atomic force microscopy (AFM) provides a novel powerful instrument for quantifying the mechanics of single cells at the nanoscale. The applications of AFM in single-cell mechanical assays in the past decade have s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.036

    authors: Li M,Liu L,Xu X,Xing X,Dang D,Xi N,Wang Y

    更新日期:2018-06-01 00:00:00

  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • Articular cartilage surface rupture during compression: investigating the effects of tissue hydration in relation to matrix health.

    abstract::This study aimed at investigating articular cartilage rupture by investigating the response of healthy and degenerate cartilage through altering the osmotic swelling environment of surface-intact, cartilage-on-bone specimens. The osmotic environment in healthy and degenerate bovine cartilage was varied by soaking tiss...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.018

    authors: Fick JM,Espino DM

    更新日期:2011-10-01 00:00:00

  • Graphite nanoplatelets-modified PLA/PCL: Effect of blend ratio and nanofiller localization on structure and properties.

    abstract::Structure and properties of poly(lactic acid) (PLA)/poly (ɛ-caprolactone) (PCL) influenced by graphite nanoplatelets (GNP) were studied in dependence on blend composition. Electron microscopy indicates predominant localization of GNP in PCL. GNP-induced changes in viscosity hinder refinement of PCL inclusions, support...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.028

    authors: Kelnar I,Kratochvíl J,Kaprálková L,Zhigunov A,Nevoralová M

    更新日期:2017-07-01 00:00:00

  • Mechanical properties of Indonesian-made narrow dynamic compression plate.

    abstract::Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.04.018

    authors: Dewo P,van der Houwen EB,Sharma PK,Magetsari R,Bor TC,Vargas-Llona LD,van Horn JR,Busscher HJ,Verkerke GJ

    更新日期:2012-09-01 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • Biomechanics of infarcted left Ventricle-A review of experiments.

    abstract::Myocardial infarction (MI) is one of leading diseases to contribute to annual death rate of 5% in the world. In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated with MI diagnosis, understanding of remodelling, MI micro-structure and biomec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2019.103591

    authors: Li W

    更新日期:2020-03-01 00:00:00

  • Simultaneous observation of calcium signaling response and membrane deformation due to localized mechanical stimulus in single osteoblast-like cells.

    abstract::Biochemical signals related to a mechanosensory mechanism by which cells sense mechanical stimuli have been gradually clarified by biological approaches such as blocking specific signaling pathways; however, mechanical signals such as deformation/strain, which is transduced into biochemical signals through this mechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.06.003

    authors: Adachi T,Sato K,Higashi N,Tomita Y,Hojo M

    更新日期:2008-01-01 00:00:00

  • Study on the effect of graphene oxide (GO) feeding on silk properties based on segmented precise measurement.

    abstract::Silk is widely used in the biomedical field (e.g., surgical sutures) for its excellent mechanical properties and biocompatibility. The properties of silk can be further enhanced by a multitude of methods, including nano particle feeding, which is convenient and green. Generally, the filament length of a silkworm cocoo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104147

    authors: Qu J,Dai M,Ye W,Fang Y,Bian D,Su W,Li F,Sun H,Wei J,Li B

    更新日期:2021-01-01 00:00:00

  • An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

    abstract::Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.033

    authors: Wierzbicki MA,Raines SB,Gordon SG,Criscione JC,Saunders AB,Birch S,Due B,Keller B,Nash LD,Miller MW,Maitland DJ

    更新日期:2017-11-01 00:00:00

  • Mechanical and biological behavior of ultrafine-grained Ti alloy aneurysm clip processed using high-pressure torsion.

    abstract::Severe plastic deformation (SPD) has recently been advanced as the main process for fabricating bulk ultrafine grained or nanocrystalline metallic materials, which present much higher strength and better bio-compatibility than coarse-grained counterparts. Medical devices, such as aneurysm clips and dental implants, re...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.002

    authors: Um HY,Park BH,Ahn DH,Abd El Aal MI,Park J,Kim HS

    更新日期:2017-04-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • On the wear behavior and damage mechanism of bonded interface: Ceramic vs resin composite inlays.

    abstract::Advances in adhesive technologies have increased indications for the use of inlays. Decrease in the bonded interface integrity due to wear has been cited as the main cause of its failure. However, this process of interface degradation and the influence of inlay material on damage mechanism appear to be poorly understo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103430

    authors: Yu P,Xiong Y,Zhao P,Xu Z,Yu H,Arola D,Gao S

    更新日期:2020-01-01 00:00:00

  • Modeling ultrasonic wave propagation in a dental implant - Bone system.

    abstract::The evolution of the bone-implant interface reflects the implant osseointegration and bond strength, thereby determining the overall implant stability in the jawbone. Quantitative ultrasound represents a promising alternative technique to characterize the interfacial integrity, precisely due to the fact that those wav...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103547

    authors: Dorogoy A,Haïat G,Shemtov-Yona K,Rittel D

    更新日期:2020-03-01 00:00:00

  • Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.

    abstract::The current study is part of an ongoing research program to develop an advanced new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite with a “sandwich structure” as a substitute for metallic materials for orthopedic long bone fracture plate applications. The purpose of this study was to assess the fatigue prope...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:

    authors: Bagheri ZS,El Sawi I,Bougherara H,Zdero R

    更新日期:2014-07-01 00:00:00

  • Fabrication, tribological and corrosion behaviors of ultra-fine grained Co-28Cr-6Mo alloy for biomedical applications.

    abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.039

    authors: Ren F,Zhu W,Chu K

    更新日期:2016-07-01 00:00:00

  • Preparation and characterization of Bis-GMA free dental resin system with synthesized dimethacrylate monomer TDDMMA derived from tricyclo[5.2.1.0(2,6)]-decanedimethanol.

    abstract::As a substitute for 2,2-bis[4-(2-hydroxy-3- methacryloxypropoxy)phenyl] propane (Bis-GMA) in dental materials, a new dimethacrylate monomer TDDMMA without bisphenol-A structure was synthesized through the reaction between tricyclo[5.2.1.0(2,6)]- decanedimethanol and 2-isocyanatoethyl methacrylate. The TDDMMA was mixed...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.020

    authors: Yin M,Liu F,He J

    更新日期:2016-04-01 00:00:00

  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00