Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening.

Abstract:

:Many treatments for cardiovascular diseases include an endovascular insertion of stents or stent grafts into arteries, a procedure which may cause high tissue stresses and even damage in the arterial wall. In order to study such problems by using finite element methods, both appropriate constitutive models and experimental data on human tissue samples are required. Layer-specific experimental data for human tissue tested up to the supra-physiological loading range are rare in the literature. In this study, intact and layer-separated experimental data from uniaxial extension tests are presented for human thoracic and abdominal aortas with non-atherosclerotic intimal thickening undergoing supra-physiological loading. A novel pseudo-elastic damage model, proposed to describe discontinuous softening in aortic arterial tissues, is fit to the obtained experimental data. Fitting of the model with and without consideration of damage accumulation in the non-collagenous matrix material reveals that tissue damage is primarily related to the collagen fiber fabric. By employing the fit model, the effect of aortic tissue pre-conditioning on the material parameters from the resulting data fits is evaluated. Histological examination of the collagen fibers under different applied stretches is used to gain more insights into the structural changes of the tissue under supra-physiological loading.

authors

Weisbecker H,Pierce DM,Regitnig P,Holzapfel GA

doi

10.1016/j.jmbbm.2012.03.012

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

93-106

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(12)00092-6

journal_volume

12

pub_type

杂志文章
  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • Micromechanical modelling of oil palm empty fruit bunch fibres containing silica bodies.

    abstract::Experimental and numerical investigation was conducted to study the micromechanics of oil palm empty fruit bunch fibres containing silica bodies. The finite viscoelastic-plastic material model called Parallel Rheological Network model was proposed, that fitted well with cyclic and stress relaxation tensile tests of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.043

    authors: Omar FN,Hanipah SH,Xiang LY,Mohammed MAP,Baharuddin AS,Abdullah J

    更新日期:2016-09-01 00:00:00

  • Monotonic and cyclic loading behavior of porous scaffolds made from poly(para-phenylene) for orthopedic applications.

    abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.004

    authors: Hoyt AJ,Yakacki CM,Fertig RS 3rd,Dana Carpenter R,Frick CP

    更新日期:2015-01-01 00:00:00

  • A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements.

    abstract::A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.022

    authors: Abdelgaied A,Fisher J,Jennings LM

    更新日期:2018-02-01 00:00:00

  • Synthesis and characterization of a novel open cellular Mg-based scaffold for tissue engineering application.

    abstract::Tissue engineering is a field which aims to regenerate damaged tissues by enhancing tissue growth through the porous architecture of the scaffolds which is desired to mimic the human cancellous bone. Mg-based scaffolds are gaining importance in the field of tissue engineering owing to its potential application as a bi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.02.010

    authors: Singh S,Vashisth P,Shrivastav A,Bhatnagar N

    更新日期:2019-06-01 00:00:00

  • Effect of aging on the transverse toughness of human cortical bone: evaluation by R-curves.

    abstract::The age-related deterioration in the quality (e.g., strength and fracture resistance) and quantity (e.g., bone-mineral density) of human bone, together with increased life expectancy, is responsible for increasing incidence of bone fracture in the elderly. The present study describes ex vivo fracture experiments to qu...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.020

    authors: Koester KJ,Barth HD,Ritchie RO

    更新日期:2011-10-01 00:00:00

  • Correlation of the mechanical and structural properties of cortical rachis keratin of rectrices of the Toco Toucan (Ramphastos toco).

    abstract::Mechanical characterization of the cortex of rectrices (tail feathers) of the Toco Toucan (Ramphastos toco) has been carried out by tensile testing of the rachis cortex in order to systematically determine Young's modulus and maximum tensile strength gradients on the surfaces and along the length of the feather. Of ov...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.010

    authors: Bodde SG,Meyers MA,McKittrick J

    更新日期:2011-07-01 00:00:00

  • Measurement of the shear modulus in thin-layered tissues using numerical simulations and shear wave elastography.

    abstract::Measurement of mechanical properties of thin-layered tissues has broad applications in the diagnosis of several pathologies. Ultrasound shear wave elastography (SWE) measures the shear wave speed as a means of estimating the mechanical properties of tissues. However, the wave speed in thin-layered tissues is affected ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103502

    authors: Sadeghi S,Cortes DH

    更新日期:2020-02-01 00:00:00

  • Reproducibility assessment of ultrasound-based aortic stiffness quantification and verification using Bi-axial tensile testing.

    abstract::Current guidelines for abdominal aortic aneurysm (AAA) repair are primarily based on the maximum diameter. Since these methods lack robustness in decision making, new image-based methods for mechanical characterization have been proposed. Recently, time-resolved 3D ultrasound (4D US) in combination with finite element...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103571

    authors: van Disseldorp EMJ,van den Hoven MHMH,van de Vosse FN,van Sambeek MRHM,Lopata RGP

    更新日期:2020-03-01 00:00:00

  • Computational micromechanics of bioabsorbable magnesium stents.

    abstract::Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.007

    authors: Grogan JA,Leen SB,McHugh PE

    更新日期:2014-06-01 00:00:00

  • Mechanical properties of bovine cortical bone based on the automated ball indentation technique and graphics processing method.

    abstract::Cortical bone provides the main form of support in humans and other vertebrates against various forces. Thus, capturing its mechanical properties is important. In this study, the mechanical properties of cortical bone were investigated by using automated ball indentation and graphics processing at both the macroscopic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.039

    authors: Zhang A,Zhang S,Bian C

    更新日期:2018-02-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • Study of nanoscale deformation mechanisms in bulk hexagonal hydroxyapatite under uniaxial loading using molecular dynamics.

    abstract::Hydroxyapatite (HAP) is a natural bioceramic which is currently used in scaffolds and coatings for the regrowth of osseous tissue but offers poor load-bearing capacity compared to other biomaterials. The deformation mechanisms responsible for the mechanical behavior of HAP are not well understood, although the advent ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103894

    authors: Snyder AD,Salehinia I

    更新日期:2020-10-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • Administration of PTH and ibandronate increases ovariectomized rat compact bone viscoelasticity.

    abstract::In this study, the bone mineral density (BMD), geometry, macroscopic viscoelastic properties and mechanical strength in five different groups of Sprague-Dawley rats (sham operated, ovariectomized with vehicle, parathyroid hormone and/or ibandronate administration) were examined by peripheral quantitative computed tomo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.009

    authors: Yang X,Teoh SH,DasDe S,Lee T

    更新日期:2013-06-01 00:00:00

  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

    abstract::The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.036

    authors: Schouman T,Schmitt M,Adam C,Dubois G,Rouch P

    更新日期:2016-06-01 00:00:00

  • Fabrication, tribological and corrosion behaviors of ultra-fine grained Co-28Cr-6Mo alloy for biomedical applications.

    abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.039

    authors: Ren F,Zhu W,Chu K

    更新日期:2016-07-01 00:00:00

  • An analytical solution for the stress state at stent-coating interfaces.

    abstract::In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.009

    authors: Parry G,McGarry P

    更新日期:2012-06-01 00:00:00

  • Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

    abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104253

    authors: Collins CJ,Yang B,Crenshaw TD,Ploeg HL

    更新日期:2021-03-01 00:00:00

  • Processing nanoengineered scaffolds through electrospinning and mineralization suitable for biomimetic bone tissue engineering.

    abstract::Processing scaffolds that mimic the extracellular matrix (ECM) of natural bone in structure and chemical composition is a potential promising option for engineering physiologically functional bone tissue. In this article, we report a novel method, by combining electrospinning and mineralization, to process a series of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.01.007

    authors: Liao S,Murugan R,Chan CK,Ramakrishna S

    更新日期:2008-07-01 00:00:00

  • Reinforcement of conventional glass-ionomer restorative material with short glass fibers.

    abstract::This study investigated the strengthening effect of glass fibers when added to conventional glass-ionomer restorative material. Glass fibers were incorporated into glass-ionomer powder in 3 wt% and 5 wt%. The fibers used had 1 mm length and 10 microm thickness. These criteria of fiber length, diameter, and concentrati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.04.002

    authors: Hammouda IM

    更新日期:2009-01-01 00:00:00

  • Evaluation of surface roughness, hardness and elastic modulus of nanoparticle containing light-polymerized denture glaze materials.

    abstract:STATEMENT OF PROBLEM:The surface hardness and roughness of different glaze materials for denture base acrylic resins have not been well reported. PURPOSE:The purpose of the study was to measure the surfaces hardness, elastic modulus and surface roughness of 5 different light-polymerized glaze materials for poly methyl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103601

    authors: Choi JJE,Uy CE,Ramani RS,Waddell JN

    更新日期:2020-03-01 00:00:00

  • Mechanical characterization of oligo(ethylene glycol)-based hydrogels by dynamic nanoindentation experiments.

    abstract::Oligo(ethylene glycol)-based (OEG) hydrogel samples of varying cross-link densities and degrees of swelling were characterized through dynamic nanoindentation testing. Experiments were performed using a non-standard nanoindentation method, which was validated on a standard polystyrene sample. This method maximizes the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.009

    authors: Guglielmi PO,Herbert EG,Tartivel L,Behl M,Lendlein A,Huber N,Lilleodden ET

    更新日期:2015-06-01 00:00:00

  • Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.

    abstract::The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.07.009

    authors: Robinson HJ,Markaki AE,Collier CA,Clyne TW

    更新日期:2011-11-01 00:00:00

  • Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices.

    abstract::Grit blasting is used as a cost-effective method to increase the surface roughness of metallic biomaterials, as Ti6Al4V and 316 LVM, to enhance the osteointegration, fixation and stability of implants. Samples of these two alloys were blasted by using alumina and zirconia particles, yielding rough (up to Ra~8μm) and n...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.10.013

    authors: Barriuso S,Chao J,Jiménez JA,García S,González-Carrasco JL

    更新日期:2014-02-01 00:00:00

  • Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles.

    abstract::Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which the material proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.006

    authors: Peters AE,Comerford EJ,Macaulay S,Bates KT,Akhtar R

    更新日期:2017-07-01 00:00:00

  • UV damage and sun care: deciphering mechanics of skin to develop next generation therapies.

    abstract::Some ultraviolet radiation (UV) is essential to the body as it stimulates the production of vitamin D, yet overexposure has deleterious consequences for the skin. UV induces structural and cellular changes across the different layers of skin tissue leading to mechanical and oxidative stress. Both are critical paramete...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.02.008

    authors: Levi K

    更新日期:2013-12-01 00:00:00

  • Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

    abstract::Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morpho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.004

    authors: Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish K

    更新日期:2015-07-01 00:00:00

  • Effects of fibrin sealant and bone fragments on defect regeneration performed on rat tibiae: An experimental study.

    abstract::Fibrin sealant (FS) is a biomaterial that exhibits hemostatic and repairing properties. It has been successfully used as scaffolds and adhesives to improve repair and regeneration of tissues. The objective of this study was to evaluate the effect of FS in the regeneration process of bone defects in male rat tibias thr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103662

    authors: de Oliveira CTB,Leonel BC,de Oliveira AC,de Brito Paiva M,Ramos J,Barraviera B,Ferreira Junior RS,Shimano AC

    更新日期:2020-04-01 00:00:00