Simultaneous observation of calcium signaling response and membrane deformation due to localized mechanical stimulus in single osteoblast-like cells.

Abstract:

:Biochemical signals related to a mechanosensory mechanism by which cells sense mechanical stimuli have been gradually clarified by biological approaches such as blocking specific signaling pathways; however, mechanical signals such as deformation/strain, which is transduced into biochemical signals through this mechanism, particularly at the cellular structural component level in a single cell, have not yet been clearly understood. This in vitro study focuses on an intracellular calcium signaling response to an applied localized deformation in a single osteoblast-like MC3T3-E1 cell, and observed localized deformation of a cell membrane and the calcium ion flux from an extracellular medium. The localized deformation was applied to a cell by indenting a microsphere onto the cell membrane using a glass microneedle. The cellular calcium signaling response and cell membrane deformation were simultaneously observed using fluorescent dyes in a vertical section under a confocal laser-scanning microscope with high spatial and temporal resolutions. Our results observed in the vertical section showed that the initiation point of the calcium ion flux is collocated at the displaced microsphere around which stretch membrane deformation was observed.

authors

Adachi T,Sato K,Higashi N,Tomita Y,Hojo M

doi

10.1016/j.jmbbm.2007.06.003

subject

Has Abstract

pub_date

2008-01-01 00:00:00

pages

43-50

issue

1

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(07)00011-2

journal_volume

1

pub_type

杂志文章
  • Measurement of the shear modulus in thin-layered tissues using numerical simulations and shear wave elastography.

    abstract::Measurement of mechanical properties of thin-layered tissues has broad applications in the diagnosis of several pathologies. Ultrasound shear wave elastography (SWE) measures the shear wave speed as a means of estimating the mechanical properties of tissues. However, the wave speed in thin-layered tissues is affected ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103502

    authors: Sadeghi S,Cortes DH

    更新日期:2020-02-01 00:00:00

  • Design of a remote-control drug delivery implantable chip for cancer local on demand therapy using ionic polymer metal composite actuator.

    abstract::Since the local, on demand, cancer therapy is a challenging clinical issue today, this paper presents the design, fabrication and characterization of a remotely controlled single reservoir drug delivery chip using Ionic Polymer Metal Composite (IPMC) actuator. Here, Drug release was externally programmed and controlle...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.034

    authors: Saneei Mousavi MS,Karami AH,Ghasemnejad M,Kolahdouz M,Manteghi F,Ataei F

    更新日期:2018-10-01 00:00:00

  • Fracture mechanics of hydroxyapatite single crystals under geometric confinement.

    abstract::Geometric confinement to the nanoscale, a concept that refers to the characteristic dimensions of structural features of materials at this length scale, has been shown to control the mechanical behavior of many biological materials or their building blocks, and such effects have also been suggested to play a crucial r...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.005

    authors: Libonati F,Nair AK,Vergani L,Buehler MJ

    更新日期:2013-04-01 00:00:00

  • Tissue mechanics of piled critical size biomimetic and biominerizable nanocomposites: Formation of bioreactor-induced stem cell gradients under perfusion and compression.

    abstract:BACKGROUND:Perfusion bioreactors are used to solve problems in critical size bone tissue engineering. Biominerizable and biocompatible nanocomposites are suitable scaffold materials for this purpose because they offer mineral components in organic carriers. Human adipose derived stem cells (ASCs) can potentially be use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.022

    authors: Baumgartner W,Welti M,Hild N,Hess SC,Stark WJ,Bürgisser GM,Giovanoli P,Buschmann J

    更新日期:2015-07-01 00:00:00

  • Preparation and characterization of Bis-GMA free dental resin system with synthesized dimethacrylate monomer TDDMMA derived from tricyclo[5.2.1.0(2,6)]-decanedimethanol.

    abstract::As a substitute for 2,2-bis[4-(2-hydroxy-3- methacryloxypropoxy)phenyl] propane (Bis-GMA) in dental materials, a new dimethacrylate monomer TDDMMA without bisphenol-A structure was synthesized through the reaction between tricyclo[5.2.1.0(2,6)]- decanedimethanol and 2-isocyanatoethyl methacrylate. The TDDMMA was mixed...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.020

    authors: Yin M,Liu F,He J

    更新日期:2016-04-01 00:00:00

  • The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    abstract::The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.005

    authors: Maru MM,Amaral M,Rodrigues SP,Santos R,Gouvea CP,Archanjo BS,Trommer RM,Oliveira FJ,Silva RF,Achete CA

    更新日期:2015-09-01 00:00:00

  • On the mechanical characterization and modeling of polymer gel brain substitute under dynamic rotational loading.

    abstract::The use of highly sensitive soft materials has become increasingly apparent in the last few years in numerous industrial fields, due to their viscous and damping nature. Unfortunately these materials remain difficult to characterize using conventional techniques, mainly because of the very low internal forces supporte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.008

    authors: Fontenier B,Hault-Dubrulle A,Drazetic P,Fontaine C,Naceur H

    更新日期:2016-10-01 00:00:00

  • Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair.

    abstract::The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.002

    authors: Podwojewski F,Otténio M,Beillas P,Guérin G,Turquier F,Mitton D

    更新日期:2014-10-01 00:00:00

  • Effects of test sample shape and surface production method on the fatigue behaviour of PMMA bone cement.

    abstract::There is no consensus over the optimal criterion to define the fatigue life of bone cement in vitro. Fatigue testing samples have been made into various shapes using different surface preparation techniques with little attention being paid to the importance of these variations on the fatigue results. The present study...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.023

    authors: Sheafi EM,Tanner KE

    更新日期:2014-01-01 00:00:00

  • Fabrication and characterization of poly(vinyl alcohol)-TiO2 nanocomposite films for orthopedic applications.

    abstract::Poly(vinyl alcohol) (PVA) is reinforced with TiO2 nanoparticles in order to enhance thermo-mechanical stabilities, surface characteristics and osteoblastic cell adhesion. PVA-TiO2 nanocomposite films with desirable mechanical, thermal and biocompatible properties are fabricated through solution casting method followed...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.009

    authors: Mohanapriya S,Mumjitha M,PurnaSai K,Raj V

    更新日期:2016-10-01 00:00:00

  • Numerical predictions of the interaction between highly nonlinear solitary waves and the microstructure of trabecular bone in the femoral head.

    abstract::The unique properties of highly nonlinear solitary waves in granular chains have prompted extensive research in the area of non-destructive testing and led to the development of new diagnostic schemes with potential applications in the healthcare industry. Here, we study numerically the interaction between highly nonl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103805

    authors: Yoon S,Schiffer A,Kim JJ,Jang IG,Lee S,Kim TY

    更新日期:2020-09-01 00:00:00

  • Characterization of persistent concussive syndrome using injury reconstruction and finite element modelling.

    abstract::Concussions occur 1.7 million times a year in North America, and account for approximately 75% of all traumatic brain injuries (TBI). Concussions usually cause transient symptoms but 10 to 20% of patients can have symptoms that persist longer than a month. The purpose of this research was to use reconstructions and fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.034

    authors: Post A,Kendall M,Koncan D,Cournoyer J,Blaine Hoshizaki T,Gilchrist MD,Brien S,Cusimano MD,Marshall S

    更新日期:2015-01-01 00:00:00

  • Surface integrity and corrosion performance of biomedical magnesium-calcium alloy processed by hybrid dry cutting-finish burnishing.

    abstract::Biodegradable magnesium-calcium (MgCa) alloy is a very attractive orthopedic biomaterial compared to permanent metallic alloys. However, the critical issue is that MgCa alloy corrodes too fast in the human organism. Compared to dry cutting, the synergistic dry cutting-finish burnishing can significantly improve corros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.026

    authors: Salahshoor M,Li C,Liu ZY,Fang XY,Guo YB

    更新日期:2018-02-01 00:00:00

  • Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices.

    abstract::Grit blasting is used as a cost-effective method to increase the surface roughness of metallic biomaterials, as Ti6Al4V and 316 LVM, to enhance the osteointegration, fixation and stability of implants. Samples of these two alloys were blasted by using alumina and zirconia particles, yielding rough (up to Ra~8μm) and n...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.10.013

    authors: Barriuso S,Chao J,Jiménez JA,García S,González-Carrasco JL

    更新日期:2014-02-01 00:00:00

  • Mechanical and biological behavior of ultrafine-grained Ti alloy aneurysm clip processed using high-pressure torsion.

    abstract::Severe plastic deformation (SPD) has recently been advanced as the main process for fabricating bulk ultrafine grained or nanocrystalline metallic materials, which present much higher strength and better bio-compatibility than coarse-grained counterparts. Medical devices, such as aneurysm clips and dental implants, re...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.002

    authors: Um HY,Park BH,Ahn DH,Abd El Aal MI,Park J,Kim HS

    更新日期:2017-04-01 00:00:00

  • Characterization of arterial flow mediated dilation via a physics-based model.

    abstract::In this paper, a physics-based mathematical model is developed to describe the transient behavior of the brachial artery during the Flow Mediated Dilation (FMD) test. The change of the artery's diameter was collected for 7 cases via in vivo, non-invasive ultrasound imaging. A theoretical model was developed to capture...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103756

    authors: Sidnawi B,Chen Z,Sehgal C,Wu Q

    更新日期:2020-07-01 00:00:00

  • Transient stiffening of cartilage during joint articulation: A microindentation study.

    abstract::As a mechanoactive tissue, articular cartilage undergoes compression and shear on a daily basis. With the advent of high resolution and sensitive mechanical testing methods, such as micro- and nanoindentation, it has become possible to assess changes in small-scale mechanical properties due to compression and shear of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104113

    authors: Yuh C,Laurent MP,Espinosa-Marzal RM,Chubinskaya S,Wimmer MA

    更新日期:2021-01-01 00:00:00

  • Mechanical performance of highly permeable laser melted Ti6Al4V bone scaffolds.

    abstract::Critically engineered stiffness and strength of a scaffold are crucial for managing maladapted stress concentration and reducing stress shielding. At the same time, suitable porosity and permeability are key to facilitate biological activities associated with bone growth and nutrient delivery. A systematic balance of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103517

    authors: Arjunan A,Demetriou M,Baroutaji A,Wang C

    更新日期:2020-02-01 00:00:00

  • Nanoscale characterization of dynamic cellular viscoelasticity by atomic force microscopy with varying measurement parameters.

    abstract::Cell mechanics plays an important role in regulating the physiological activities of cells. The advent of atomic force microscopy (AFM) provides a novel powerful instrument for quantifying the mechanics of single cells at the nanoscale. The applications of AFM in single-cell mechanical assays in the past decade have s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.036

    authors: Li M,Liu L,Xu X,Xing X,Dang D,Xi N,Wang Y

    更新日期:2018-06-01 00:00:00

  • Assessing the microstructural response to applied deformation in porcine passive skeletal muscle.

    abstract::The passive micro-structural mechanical response of muscle tissue is important for numerous medical applications. However, the recently observed tension/compression asymmetry in porcine muscle remains poorly explained. In particular there remains a lack of understanding of how external tension or compression applied i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.019

    authors: Takaza M,Cooney GM,McManus G,Stafford P,Simms CK

    更新日期:2014-12-01 00:00:00

  • Identification of biomechanical properties in vivo in human uterine cervix.

    abstract:BACKGROUND AND AIMS:The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregna...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.005

    authors: Liao D,Hee L,Sandager P,Uldbjerg N,Gregersen H

    更新日期:2014-11-01 00:00:00

  • Failure analysis of the fractured wires in sternal perichronal loops.

    abstract::We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.02.015

    authors: Chao J,Voces R,Peña C

    更新日期:2011-10-01 00:00:00

  • A microstructurally-based, multi-scale, continuum-mechanical model for the passive behaviour of skeletal muscle tissue.

    abstract::This work presents a novel microstructurally-based, multi-scale model describing the passive behaviour of skeletal muscle tissue. The model is based on the detailed description of the mechanically relevant parts of the microstructure. The effective constitutive material response is obtained by a homogenisation of mech...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.012

    authors: Bleiler C,Ponte Castañeda P,Röhrle O

    更新日期:2019-09-01 00:00:00

  • Profile of a 10-MDP-based universal adhesive system associated with chlorhexidine: Dentin bond strength and in situ zymography performance.

    abstract::The incorporation of functional monomers and proteolytic inhibitors into adhesive systems have shown to be promising strategies to improve the longevity of adhesive restorations. The aim of this study was to evaluate the long-term bonding performance and anti-gelatinolytic effect of a 10-MDP-based universal adhesive s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103925

    authors: Giacomini MC,Scaffa PMC,Gonçalves RS,Zabeu GS,Vidal CMP,Carrilho MRO,Honório HM,Wang L

    更新日期:2020-10-01 00:00:00

  • An interpenetrating network composite for a regenerative spinal disc application.

    abstract::Severe degeneration of the intervertebral disc has an immensely debilitating effect on quality of life that has become a serious health and economic burden throughout the world. The disc plays an integral role in biomechanical movement and support within the spine. The emergence of tissue engineering endeavours to res...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.10.015

    authors: Chan AH,Boughton PC,Ruys AJ,Oyen ML

    更新日期:2017-01-01 00:00:00

  • Constitutive modeling of human saphenous veins at overloading pressures.

    abstract::In the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and aniso...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.023

    authors: Veselý J,Horný L,Chlup H,Adámek T,Krajíček M,Žitný R

    更新日期:2015-05-01 00:00:00

  • Novel microstructural findings in M. plantaris and their impact during active and passive loading at the macro level.

    abstract::There are several studies dealing with experimental and structural analyses of skeletal muscles that are aimed at gaining a better understanding of three-dimensional muscle deformation and force generation. A variety of these contributions have performed structural or mechanical analyses, but very few have combined th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.026

    authors: Böl M,Leichsenring K,Ernst M,Wick C,Blickhan R,Siebert T

    更新日期:2015-11-01 00:00:00

  • Biorelevant polyanions stabilize fibrin against mechanical and proteolytic decomposition: Effects of polymer size and electric charge.

    abstract::The release of neutrophil extracellular traps (NETs) containing DNA and histones is an essential mechanism in the neutrophil-mediated innate immunity. In thrombi the polyanionic DNA confers mechanical and lytic resistance to fibrin and heparins interfere with the effects of NET components. Heparins are polyanions used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103459

    authors: Komorowicz E,Balázs N,Tanka-Salamon A,Varga Z,Szabó L,Bóta A,Longstaff C,Kolev K

    更新日期:2020-02-01 00:00:00

  • Reduction of load-bearing capacity of all-ceramic crowns due to cement aging.

    abstract::The purpose of this study was to investigate how water aging of the resin cement influences the stress distribution in all-ceramic crowns and if there is an increase in the propensity for crown failure. The failure of all-ceramic crowns attributed to cement degradation was explored using a combination of experimental ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.003

    authors: Lu C,Wang R,Mao S,Arola D,Zhang D

    更新日期:2013-01-01 00:00:00

  • Effects of homogenization technique and introduction of interfaces in a multiscale approach to predict the elastic properties of arthropod cuticle.

    abstract::In this paper the mechanical response of the arthropod cuticle is evaluated by means of a multiscale approach including interface effects. The cuticle's elastic behavior is modeled at the nano and the micro scales by mean-field homogenization techniques. With respect to the work of Nikolov et al. (2011), the idea has ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.003

    authors: Lhadi S,Ahzi S,Rémond Y,Nikolov S,Fabritius H

    更新日期:2013-07-01 00:00:00