Characterization of arterial flow mediated dilation via a physics-based model.

Abstract:

:In this paper, a physics-based mathematical model is developed to describe the transient behavior of the brachial artery during the Flow Mediated Dilation (FMD) test. The change of the artery's diameter was collected for 7 cases via in vivo, non-invasive ultrasound imaging. A theoretical model was developed to capture the response of the blood vessel to the change of the blood flow, in which the vessel's compliance is modeled as a function of the wall shear stress (WSS). The theory precisely captures the key feature of the mechanotransduction process, which a conventional viscoelastic model fails to describe. Three characteristic dimensionless parameters were obtained from the model, quantifying the physical state of the artery and related to the cardiovascular health. The transient physics, manifested in the two-way (where both arterial compliance and blood flow conditions affect each other) Fluid-Structure Interaction (FSI) process, present an interesting opportunity to explore the nature of living materials making up the arterial walls, which would in turn lead to a better understanding and therefore detection of the onset of some forms of cardiovascular diseases (CVD).

authors

Sidnawi B,Chen Z,Sehgal C,Wu Q

doi

10.1016/j.jmbbm.2020.103756

subject

Has Abstract

pub_date

2020-07-01 00:00:00

pages

103756

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(20)30310-6

journal_volume

107

pub_type

杂志文章
  • Development of a bite force transducer for measuring maximum voluntary bite forces between individual opposing tooth surfaces.

    abstract::Bite forces are studied in order to understand a wide range of factors pertaining to the mastication system. Various strain gauge transducers have been employed to measure bite forces, with several descriptions of these available in the literature; unfortunately, many reports provide insufficient detail to enable accu...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103846

    authors: Jansen van Vuuren L,Jansen van Vuuren WA,Broadbent JM,Duncan WJ,Waddell JN

    更新日期:2020-09-01 00:00:00

  • Finite element simulation for the mechanical characterization of soft biological materials by atomic force microscopy.

    abstract::The characterization of the mechanical properties of soft materials has been traditionally performed through uniaxial tensile tests. Nevertheless, this method cannot be applied to certain extremely soft materials, such as biological tissues or cells that cannot be properly subjected to these tests. Alternative non-des...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.006

    authors: Valero C,Navarro B,Navajas D,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Load-bearing in cortical bone microstructure: Selective stiffening and heterogeneous strain distribution at the lamellar level.

    abstract::An improved understanding of bone mechanics is vital in the development of evaluation strategies for patients at risk of bone fracture. The current evaluation approach based on bone mineral density (BMD) measurements lacks sensitivity, and it has become clear that as well as bone mass, bone quality should also be eval...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.016

    authors: Katsamenis OL,Chong HM,Andriotis OG,Thurner PJ

    更新日期:2013-01-01 00:00:00

  • Analysis of the mechanical response of biomimetic materials with highly oriented microstructures through 3D printing, mechanical testing and modeling.

    abstract::Many biomineralized organisms have evolved highly oriented nanostructures to perform specific functions. One key example is the abrasion-resistant rod-like microstructure found in the radular teeth of Chitons (Cryptochiton stelleri), a large mollusk. The teeth consist of a soft core and a hard shell that is abrasion r...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.026

    authors: de Obaldia EE,Jeong C,Grunenfelder LK,Kisailus D,Zavattieri P

    更新日期:2015-08-01 00:00:00

  • Mechanical properties, electrochemical corrosion and in-vitro bioactivity of yttria stabilized zirconia reinforced hydroxyapatite coatings prepared by gas tunnel type plasma spraying.

    abstract::Yttria stabilized zirconia reinforced hydroxyapatite coatings were deposited by a gas tunnel type plasma spray torch under optimum spraying conditions. For this purpose, 10, 20 and 30 wt% of yttria stabilized zirconia (YSZ) powders were premixed individually with hydroxyapatite (HA) powder and were used as the feedsto...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.002

    authors: Yugeswaran S,Yoganand CP,Kobayashi A,Paraskevopoulos KM,Subramanian B

    更新日期:2012-05-01 00:00:00

  • Biomechanics of infarcted left Ventricle-A review of experiments.

    abstract::Myocardial infarction (MI) is one of leading diseases to contribute to annual death rate of 5% in the world. In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated with MI diagnosis, understanding of remodelling, MI micro-structure and biomec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2019.103591

    authors: Li W

    更新日期:2020-03-01 00:00:00

  • Identification of biomechanical properties in vivo in human uterine cervix.

    abstract:BACKGROUND AND AIMS:The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregna...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.005

    authors: Liao D,Hee L,Sandager P,Uldbjerg N,Gregersen H

    更新日期:2014-11-01 00:00:00

  • Microstructure and mechanical properties of MgO-stabilized ZrO₂-Al₂O₃ dental composites.

    abstract::The aim of the present study was to investigate the production of tetragonal zirconia (t-ZrO(2)) particles (experimental t-ZrO(2)) from monoclinic zirconia (m-ZrO(2)) and to evaluate the effect of the t-ZrO(2) content on the fracture toughness of alumina-zirconia composites by conducting ASTM E399 standard test. In th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.11.007

    authors: Abi CB,Emrullahoğlu OF,Said G

    更新日期:2013-02-01 00:00:00

  • Verification and implementation of a modified split Hopkinson pressure bar technique for characterizing biological tissue and soft biosimulant materials under dynamic shear loading.

    abstract::Modeling human body response to dynamic loading events and developing biofidelic human surrogate systems require accurate material properties over a range of loading rates for various human organ tissues. This work describes a technique for measuring the shear properties of soft biomaterials at high rates of strain (1...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.06.008

    authors: Trexler MM,Lennon AM,Wickwire AC,Harrigan TP,Luong QT,Graham JL,Maisano AJ,Roberts JC,Merkle AC

    更新日期:2011-11-01 00:00:00

  • A new constitutive model for simulation of softening, plateau, and densification phenomena for trabecular bone under compression.

    abstract::A new type of constitutive model and its computational implementation procedure for the simulation of a trabecular bone are proposed in the present study. A yield surface-independent Frank-Brockman elasto-viscoplastic model is introduced to express the nonlinear material behavior such as softening beyond yield point, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.028

    authors: Lee CS,Lee JM,Youn B,Kim HS,Shin JK,Goh TS,Lee JS

    更新日期:2017-01-01 00:00:00

  • Intrafibrillar plasticity through mineral/collagen sliding is the dominant mechanism for the extreme toughness of antler bone.

    abstract::The inelastic deformability of the mineralised matrix in bones is critical to their high toughness, but the nanoscale mechanisms are incompletely understood. Antler is a tough bone type, with a nanostructure composed of mineralised collagen fibrils ∼100nm diameter. We track the fibrillar deformation of antler tissue d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.020

    authors: Gupta HS,Krauss S,Kerschnitzki M,Karunaratne A,Dunlop JW,Barber AH,Boesecke P,Funari SS,Fratzl P

    更新日期:2013-12-01 00:00:00

  • Characterization and fatigue damage of plasma sprayed HAp top coat with Ti and HAp/Ti bond coat layers on commercially pure titanium substrate.

    abstract::The surface of commercially pure Ti (cp-Ti) substrate was grit-blasted with Al(2)O(3) powders and then wet-blasted with HAp/Ti mixed powders at room temperature. Then plasma spraying with Ti powders or HAp/Ti mixed powders on the blasted surface was carried out to form a bond coat layer, denoted as T50 and T100 bond c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.11.001

    authors: Rakngarm A,Mutoh Y

    更新日期:2009-10-01 00:00:00

  • The functions of hydrophobic elastic polyurethane combined with an antibacterial triclosan derivative in the dentin restoration interface.

    abstract::Dentin restoration produces weak interfaces because of the effects of bacterial microflora, biofilms, and mechanical, thermal, and shrinkage stresses. This results in secondary caries. Therefore, hydrophobic elastic polyurethane (PU) containing different concentrations of triclosan derivatives was synthesized and appl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103471

    authors: Guo X,Cheng Q,Yu G,Wang H,Tian Z,Shi Z,Cui Z,Zhu S

    更新日期:2020-02-01 00:00:00

  • Preparation and properties of an injectable scaffold of poly(lactic-co-glycolic acid) microparticles/chitosan hydrogel.

    abstract::Hydrogels are more and more attractive in biomedical fields, since they can be used as injectable scaffolds, drugs and gene carriers and smart sensors. The highly hydrated hydrogels, however, generally have low mechanical strength. In this work, a composite chitosan hydrogel was prepared by blending water soluble and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.02.001

    authors: Hu X,Zhou J,Zhang N,Tan H,Gao C

    更新日期:2008-10-01 00:00:00

  • In-situ synthesis of AgNPs in the natural/synthetic hybrid nanofibrous scaffolds: Fabrication, characterization and antimicrobial activities.

    abstract::Silver nanoparticles embedded within a nanofibrous polymer matrix have significant attention in recent years as an antimicrobial wound dressing materials. Herein, we have fabricated a novel Ag-polyurethane-zein hybrid nanofibrous scaffold for wound dressing applications. AgNPs were synthesized in-situ via reduction of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.07.034

    authors: Maharjan B,Joshi MK,Tiwari AP,Park CH,Kim CS

    更新日期:2017-01-01 00:00:00

  • Transient behavior and relaxation of microcapsules with a cross-linked human serum albumin membrane.

    abstract::Capsules consist of droplets enclosed by a membrane with shear resistant properties especially when fabricated by interfacial cross-linking. In many applications, the protection and release of the internal medium need to be strictly controlled. It is possible to tune the membrane mechanical properties by changing the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.008

    authors: Gires PY,Barthès-Biesel D,Leclerc E,Salsac AV

    更新日期:2016-05-01 00:00:00

  • Setting mechanism of a new injectable Dicalcium Phosphate Dihydrate (DCPD) forming cement.

    abstract::We previously described the gelation mechanism of calcium polyphosphate (CPP) in the presence of water. In this study, we developed novel and injectable poly-dicalcium phosphate dihydrate (P-DCPD) forming cement by the reaction of acidic CPP gel with alkali tetracalcium phosphate (TTCP). The setting reaction mechanism...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.032

    authors: Ren W,Song W,Yurgelevic S,Markel DC

    更新日期:2018-03-01 00:00:00

  • Comparison of mechanical testing methods for biomaterials: Pipette aspiration, nanoindentation, and macroscale testing.

    abstract::Characterization of the mechanical properties of biological materials is often complicated by small volume, irregular geometry, fragility, and environmental sensitivity. Pipette aspiration and nanoindentation testing deal well with these limitations and have seen increasing use in biomaterial characterization, but lit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.022

    authors: Buffinton CM,Tong KJ,Blaho RA,Buffinton EM,Ebenstein DM

    更新日期:2015-11-01 00:00:00

  • Biomechanical, structural and biological characterisation of a new silk fibroin scaffold for meniscal repair.

    abstract::Meniscal injury is typically treated surgically via partial meniscectomy, which has been shown to cause cartilage degeneration in the long-term. Consequently, research has focused on meniscal prevention and replacement. However, none of the materials or implants developed for meniscal replacement have yet achieved wid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.041

    authors: Warnecke D,Stein S,Haffner-Luntzer M,de Roy L,Skaer N,Walker R,Kessler O,Ignatius A,Dürselen L

    更新日期:2018-10-01 00:00:00

  • In vivo assessment of material properties of muscles and connective tissues around the knee joint based on shear wave elastography.

    abstract::Previous studies on knee biomechanics have mainly focused on the joint structure itself, largely neglecting the material properties of the muscles and connective tissues around the knee joint. Therefore, this study was purposed to conduct a systematic in vivo examination of the material properties of muscles, tendons,...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103829

    authors: Wu J,Qian Z,Liang W,Liu J,Ren L,Ren L

    更新日期:2020-09-01 00:00:00

  • Adhesion of ligand-conjugated biosynthesized magnetite nanoparticles to triple negative breast cancer cells.

    abstract::This paper presents the results of an experimental study of the adhesion forces between components of model conjugated magnetite nanoparticle systems for improved selectivity in the specific targeting of triple negative breast cancer. Adhesion forces between chemically synthesized magnetite nanoparticles (CMNPs), bios...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.004

    authors: Obayemi JD,Hu J,Uzonwanne VO,Odusanya OS,Malatesta K,Anuku N,Soboyejo WO

    更新日期:2017-04-01 00:00:00

  • A microstructurally-based, multi-scale, continuum-mechanical model for the passive behaviour of skeletal muscle tissue.

    abstract::This work presents a novel microstructurally-based, multi-scale model describing the passive behaviour of skeletal muscle tissue. The model is based on the detailed description of the mechanically relevant parts of the microstructure. The effective constitutive material response is obtained by a homogenisation of mech...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.012

    authors: Bleiler C,Ponte Castañeda P,Röhrle O

    更新日期:2019-09-01 00:00:00

  • Damage initiation and progression in the cartilage surface probed by nonlinear optical microscopy.

    abstract::With increasing interest in treating osteoarthritis at its earliest stages, it has become important to understand the mechanisms by which the disease progresses across a joint. Here, second harmonic generation (SHG) microscopy, coupled with a two-dimensional spring-mass network model, was used to image and investigate...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.004

    authors: Brown CP,Houle MA,Chen M,Price AJ,Légaré F,Gill HS

    更新日期:2012-01-01 00:00:00

  • The impact of discrete compartments of a multi-compartment collagen-GAG scaffold on overall construct biophysical properties.

    abstract::Orthopedic interfaces such as the tendon-bone junction (TBJ) present unique challenges for biomaterials development. Here we describe a multi-compartment collagen-GAG scaffold fabricated via lyophilization that contains discrete mineralized (CGCaP) and non-mineralized (CG) regions joined by a continuous interface. Mod...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.07.016

    authors: Weisgerber DW,Kelkhoff DO,Caliari SR,Harley BA

    更新日期:2013-12-01 00:00:00

  • Improved tribocorrosion performance of bio-functionalized TiO2 nanotubes under two-cycle sliding actions in artificial saliva.

    abstract::After insertion into bone, dental implants may be subjected to tribocorrosive conditions resulting in the release of metallic ions and solid wear debris, which can induce to peri-implant inflammatory reactions accompanied by bone loss, and ultimately implant loosening. Despite the promising ability of TiO2 nanotubes (...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.038

    authors: Alves SA,Rossi AL,Ribeiro AR,Toptan F,Pinto AM,Shokuhfar T,Celis JP,Rocha LA

    更新日期:2018-04-01 00:00:00

  • Contact angle study of blood dilutions on common microchip materials.

    abstract::Biocompatible polymers are commonly used to fabricate microfluidic channels for the study of biological flows such as blood microflows. The most common of these materials is polydimethylsiloxane (PDMS) which is very hydrophobic. Oxygenated plasma is advocated to treat the PDMS with reported decreases in contact angle ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.07.007

    authors: Pitts KL,Abu-Mallouh S,Fenech M

    更新日期:2013-01-01 00:00:00

  • Modeling failure of soft anisotropic materials with application to arteries.

    abstract::The arterial wall is a composite where the preferred orientation of collagen fibers induces anisotropy. Though the hyperelastic theories of fiber-reinforced composites reached a high level of sophistication and showed a reasonable correspondence with the available experimental data they are short of the failure descri...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.002

    authors: Volokh KY

    更新日期:2011-11-01 00:00:00

  • Effects of compression on orientation of ligands in fluorescent complexes between hydroxyapatite with amino acids and their optical properties.

    abstract::This study aims to reveal the effects of pressure during cold isostatic pressing (CIP) on the microstructure and optical properties of fluorescent HAp complexes. Although the microsturucture-dependent properties of fluorescent HAp complexes have been reported to improve the antibacterial properties of photocatalyst co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.09.006

    authors: Morakul S,Otsuka Y,Nararya A,Tagaya M,Motozuka S,Ohnuma K,Miyashita Y,Mutoh Y

    更新日期:2018-12-01 00:00:00

  • Profile of a 10-MDP-based universal adhesive system associated with chlorhexidine: Dentin bond strength and in situ zymography performance.

    abstract::The incorporation of functional monomers and proteolytic inhibitors into adhesive systems have shown to be promising strategies to improve the longevity of adhesive restorations. The aim of this study was to evaluate the long-term bonding performance and anti-gelatinolytic effect of a 10-MDP-based universal adhesive s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103925

    authors: Giacomini MC,Scaffa PMC,Gonçalves RS,Zabeu GS,Vidal CMP,Carrilho MRO,Honório HM,Wang L

    更新日期:2020-10-01 00:00:00

  • Glycerol-dimethacrylate as alternative hydrophilic monomer for HEMA replacement in simplified adhesives.

    abstract:OBJECTIVES:Hydroxyethyl-methacrylate (HEMA) is still widely used in simplified adhesives. Indeed, several shortcomings occur with this monomer, such as water uptake and formation of linear polymers. This study aimed to compare the effects of HEMA replacement by glycerol-dimethacrylate (GDMA) on selected physicochemical...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.022

    authors: Araújo-Neto VG,Nobre CFA,De Paula DM,Souza LC,Silva JC,Moreira MM,Picanço PRB,Feitosa VP