Improved tribocorrosion performance of bio-functionalized TiO2 nanotubes under two-cycle sliding actions in artificial saliva.

Abstract:

:After insertion into bone, dental implants may be subjected to tribocorrosive conditions resulting in the release of metallic ions and solid wear debris, which can induce to peri-implant inflammatory reactions accompanied by bone loss, and ultimately implant loosening. Despite the promising ability of TiO2 nanotubes (NTs) to improve osseointegration and avoid infection-related failures, the understanding of their degradation under the simultaneous action of wear and corrosion (tribocorrosion) is still very limited. This study aims, for the first time, to study the tribocorrosion behavior of bio-functionalized TiO2 NTs submitted to two-cycle sliding actions, and compare it with conventional TiO2 NTs. TiO2 NTs grown by anodization were doped with bioactive elements, namely calcium (Ca), phosphorous (P), and zinc (Zn), through reverse polarization anodization treatments. Characterization techniques such as scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and scanning transmission electron microscopy (STEM), were used to characterize the films. Tribocorrosion tests were carried out in artificial saliva (AS) by applying two cycles of reciprocating sliding actions. The open circuit potential (OCP) was monitored before, during, and after both cycles of sliding, during which the coefficient of friction (COF) was calculated. The resulting wear scars were analyzed by SEM and EDS, and wear volume measurements were performed by 2D profilometry. Finally, the mechanical features of TiO2 NTs were accessed by nanoindentation. The results show that bio-functionalized TiO2 NTs display an enhanced tribocorrosion performance, ascribed to the growth of a nano-thick oxide film at Ti/TiO2 NTs interface, which significantly increased their adhesion strength to the substrate and consequently their hardness. Furthermore, it was discovered that during tribo-electrochemical solicitations, the formation of a P-rich tribofilm takes place, which grants both electrochemical protection and resistance to mechanical wear. This study provides fundamental and new insights for the development of multifunctional TiO2 NTs with long-term biomechanical stability and improved clinical outcomes.

authors

Alves SA,Rossi AL,Ribeiro AR,Toptan F,Pinto AM,Shokuhfar T,Celis JP,Rocha LA

doi

10.1016/j.jmbbm.2018.01.038

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

143-154

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(18)30057-2

journal_volume

80

pub_type

杂志文章
  • Statistics in experimental studies on the human spine: Theoretical basics and review of applications.

    abstract::Proper statistical analysis is essential in the research studies. In particular, as regards the in vitro testing of the lumbar spine, the criteria for the standardization have been extensively discussed but the use of statistics has not been reviewed. Unfortunately, cadaveric testing is a very difficult and complex ex...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103862

    authors: Bassani T,Galbusera F

    更新日期:2020-10-01 00:00:00

  • Heterogeneous modeling based prosthesis design with porosity and material variation.

    abstract::The work proposes the development of heterogeneous bio-implants with the aim to minimize stress shielding effect and enhance bone ingrowth. Stress shielding in the implant can be minimized by reducing the overall stiffness of the implant, which is achieved here by varying the material based on stress distribution acro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.029

    authors: Singh SK,Tandon P

    更新日期:2018-11-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • Micromechanisms of fatigue crack growth in polycarbonate polyurethane: Time dependent and hydration effects.

    abstract::Polycarbonate polyurethane has cartilage-like, hygroscopic, and elastomeric properties that make it an attractive material for orthopedic joint replacement application. However, little data exists on the cyclic loading and fracture behavior of polycarbonate polyurethane. This study investigates the mechanisms of fatig...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.008

    authors: Ford AC,Gramling H,Li SC,Sov JV,Srinivasan A,Pruitt LA

    更新日期:2018-03-01 00:00:00

  • The applicability of PEEK-based abutment screws.

    abstract::The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.024

    authors: Schwitalla AD,Abou-Emara M,Zimmermann T,Spintig T,Beuer F,Lackmann J,Müller WD

    更新日期:2016-10-01 00:00:00

  • Reproducibility assessment of ultrasound-based aortic stiffness quantification and verification using Bi-axial tensile testing.

    abstract::Current guidelines for abdominal aortic aneurysm (AAA) repair are primarily based on the maximum diameter. Since these methods lack robustness in decision making, new image-based methods for mechanical characterization have been proposed. Recently, time-resolved 3D ultrasound (4D US) in combination with finite element...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103571

    authors: van Disseldorp EMJ,van den Hoven MHMH,van de Vosse FN,van Sambeek MRHM,Lopata RGP

    更新日期:2020-03-01 00:00:00

  • Hydrogels with differential and patterned mechanics to study stiffness-mediated myofibroblastic differentiation of hepatic stellate cells.

    abstract::The differentiation of hepatic stellate cells (HSCs) into myofibroblasts is a key event in liver fibrosis. Due to the local stiffening of the extracellular matrix (ECM) during fibrosis, it is of great interest to develop mimics that can be used to investigate the cellular response to changes in mechanics. Here, we use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.11.008

    authors: Guvendiren M,Perepelyuk M,Wells RG,Burdick JA

    更新日期:2014-10-01 00:00:00

  • Translucency, hardness and strength parameters of PMMA resin containing graphene-like material for CAD/CAM restorations.

    abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103388

    authors: Agarwalla SV,Malhotra R,Rosa V

    更新日期:2019-12-01 00:00:00

  • Assessing the microstructural response to applied deformation in porcine passive skeletal muscle.

    abstract::The passive micro-structural mechanical response of muscle tissue is important for numerous medical applications. However, the recently observed tension/compression asymmetry in porcine muscle remains poorly explained. In particular there remains a lack of understanding of how external tension or compression applied i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.019

    authors: Takaza M,Cooney GM,McManus G,Stafford P,Simms CK

    更新日期:2014-12-01 00:00:00

  • Fatigue and durability of Nitinol stents.

    abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.08.001

    authors: Pelton AR,Schroeder V,Mitchell MR,Gong XY,Barney M,Robertson SW

    更新日期:2008-04-01 00:00:00

  • A constitutive law for degrading bioresorbable polymers.

    abstract::This paper presents a constitutive law that predicts the changes in elastic moduli, Poisson's ratio and ultimate tensile strength of bioresorbable polymers due to biodegradation. During biodegradation, long polymer chains are cleaved by hydrolysis reaction. For semi-crystalline polymers, the chain scissions also lead ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.026

    authors: Samami H,Pan J

    更新日期:2016-06-01 00:00:00

  • Constitutive modeling of human saphenous veins at overloading pressures.

    abstract::In the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and aniso...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.023

    authors: Veselý J,Horný L,Chlup H,Adámek T,Krajíček M,Žitný R

    更新日期:2015-05-01 00:00:00

  • Wear characterization and contact surfaces analysis of menisci and femoral retrieved components in bi-condylar knee prostheses.

    abstract:PURPOSE:Although total knee arthroplasty is a well-practiced surgical procedure, material properties and surface topography can contribute to the wear mechanisms and the implant failure. It has been advised that an increased femoral component's surface roughness of total knee prostheses may be a contributing factor to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103959

    authors: Affatato S,Ruzzi S,Milosevic M,Ruggiero A

    更新日期:2020-10-01 00:00:00

  • On the tension-compression switch hypothesis in arterial mechanics.

    abstract::The tension-compression switch hypothesis for soft tissue proposes that when collagen fibres are compressed they do not contribute to the mechanical response which is then assumed to be the isotropic response of the extra-cellular matrix in which they are embedded. Such an assumption would seem reasonable. However, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103558

    authors: Horgan CO,Murphy JG

    更新日期:2020-03-01 00:00:00

  • Experimental and constitutive modeling approaches for a study of biomechanical properties of human coronary arteries.

    abstract::The study concerns the determination of mechanical properties of human coronary arterial walls with both experimental and constitutive modeling approaches. The research material was harvested from 18 patients (range 50-84 years). On the basis of hospital records and visual observation, each tissue sample was classifie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.021

    authors: Jankowska MA,Bartkowiak-Jowsa M,Bedzinski R

    更新日期:2015-10-01 00:00:00

  • Role of porosity and matrix behavior on compressive fracture of Haversian bone using random spring network model.

    abstract::Haversian remodeling is known to result in improved resistance to compressive fracture in healthy cortical bone. Here, we examine the individual roles of the mean porosity, structure of the network of pores and remodeled bone matrix properties in the fracture behavior of Haversian bone. The detailed structure of poros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.013

    authors: Mayya A,Banerjee A,Rajesh R

    更新日期:2018-07-01 00:00:00

  • Towards intervertebral disc engineering: Bio-mimetics of form and function of the annulus fibrosus lamellae.

    abstract::The aging western society is heavily afflicted with intervertebral disc (IVD) degeneration. Replacement or repair of the degenerated IVD with an artificial bio-mimetic construct is one of the challenges of future research due to its complex structure and unique biomechanical function. Herein, biocomposite laminates ma...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.023

    authors: Sharabi M,Wertheimer S,Wade KR,Galbusera F,Benayahu D,Wilke HJ,Haj-Ali R

    更新日期:2019-06-01 00:00:00

  • A new constitutive model for simulation of softening, plateau, and densification phenomena for trabecular bone under compression.

    abstract::A new type of constitutive model and its computational implementation procedure for the simulation of a trabecular bone are proposed in the present study. A yield surface-independent Frank-Brockman elasto-viscoplastic model is introduced to express the nonlinear material behavior such as softening beyond yield point, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.028

    authors: Lee CS,Lee JM,Youn B,Kim HS,Shin JK,Goh TS,Lee JS

    更新日期:2017-01-01 00:00:00

  • The effect of equiaxial stretching on the osteogenic differentiation and mechanical properties of human adipose stem cells.

    abstract::Although mechanical cues are known to affect stem cell fate and mechanobiology, the significance of such stimuli on the osteogenic differentiation of human adipose stem cells (hASCs) remains unclear. In this study, we investigated the effect of long-term mechanical stimulation on the attachment, osteogenic differentia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.016

    authors: Virjula S,Zhao F,Leivo J,Vanhatupa S,Kreutzer J,Vaughan TJ,Honkala AM,Viehrig M,Mullen CA,Kallio P,McNamara LM,Miettinen S

    更新日期:2017-08-01 00:00:00

  • A combined strategy to enhance the properties of Zn by laser rapid solidification and laser alloying.

    abstract::The orthopedic application of Zn is limited owing to the poor strength and low plasticity. In this study, a novel strategy by combining rapid solidification obtained by selective laser melting (SLM) and alloying with Mg was proposed to improve the mechanical properties of Zn. The microstructures, mechanical properties...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.018

    authors: Yang Y,Yuan F,Gao C,Feng P,Xue L,He S,Shuai C

    更新日期:2018-06-01 00:00:00

  • Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.

    abstract::This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.023

    authors: Liu Y,Zhu G,Yang H,Wang C,Zhang P,Han G

    更新日期:2018-01-01 00:00:00

  • "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.

    abstract::The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.026

    authors: Ridone P,Grage SL,Patkunarajah A,Battle AR,Ulrich AS,Martinac B

    更新日期:2018-03-01 00:00:00

  • Through-thickness stress relaxation in bacterial cellulose hydrogel.

    abstract::Biological hydrogels, e.g. bacterial cellulose (BC) hydrogel, attracted increasing interest in recent decades since they show a good potential for biomedical engineering as replacements of real tissues thanks mainly to their good biocompatibility and fibrous structure. To select potential candidates for such applicati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.021

    authors: Gao X,Kuśmierczyk P,Shi Z,Liu C,Yang G,Sevostianov I,Silberschmidt VV

    更新日期:2016-06-01 00:00:00

  • Planar biaxial extension of the lumbar facet capsular ligament reveals significant in-plane shear forces.

    abstract::The lumbar facet capsular ligament (FCL) articulates with six degrees of freedom during spinal motions of flexion/extension, lateral bending, and axial rotation. The lumbar FCL is composed of highly aligned collagen fiber bundles on the posterior surface (oriented primarily laterally between the rigid articular facets...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.019

    authors: Claeson AA,Barocas VH

    更新日期:2017-01-01 00:00:00

  • Fabrication and mechanical properties of Al2O3/SiC/ZrO2 functionally graded material by electrophoretic deposition.

    abstract::This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.029

    authors: Askari E,Mehrali M,Metselaar IH,Kadri NA,Rahman MM

    更新日期:2012-08-01 00:00:00

  • Myoglobin and troponin concentrations are increased in early stage deep tissue injury.

    abstract::Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomark...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.026

    authors: Traa WA,Strijkers GJ,Bader DL,Oomens CWJ

    更新日期:2019-04-01 00:00:00

  • An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

    abstract::Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.033

    authors: Wierzbicki MA,Raines SB,Gordon SG,Criscione JC,Saunders AB,Birch S,Due B,Keller B,Nash LD,Miller MW,Maitland DJ

    更新日期:2017-11-01 00:00:00

  • Clamping soft biologic tissues for uniaxial tensile testing: A brief survey of current methods and development of a novel clamping mechanism.

    abstract::Biologic tissues are complex materials that come in many forms and perform a variety of functions. They vary widely in composition and mechanical properties, and determination of the mechanical properties of tissues is of interest to those trying to engineer tissues to restore missing function. In performing experimen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103503

    authors: Jiang M,Lawson ZT,Erel V,Pervere S,Nan T,Robbins AB,Feed AD,Moreno MR

    更新日期:2020-03-01 00:00:00

  • Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species.

    abstract::Due to its proximity to the mitral valve, the coronary sinus (CS) vessel serves as a conduit for the deployment and implantation of the percutaneous transvenous mitral annuloplasty (PTMA) devices that can potentially reduce the mitral regurgitation. Because CS vessel is a venous tissue and seldom diseased, its mechani...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.09.001

    authors: Pham T,Sun W

    更新日期:2012-02-01 00:00:00

  • An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets.

    abstract::The atrioventricular heart valve (AHV) leaflets are critical to the facilitation of proper unidirectional blood flow through the heart. Previously, studies have been conducted to understand the tissue mechanics of healthy AHV leaflets to inform the development of valve-specific computational models and replacement mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103438

    authors: Duginski GA,Ross CJ,Laurence DW,Johns CH,Lee CH

    更新日期:2020-01-01 00:00:00