Abstract:
:Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identifying small AF defects with biomechanical testing can be difficult because IVDs have a complex, composite structure and nonlinear biomechanical properties that are dependent on AF fiber tension. It remains unclear how choice of biomechanical testing protocols affect the sensitivity of biomechanical properties to AF injuries. This study determined whether axial preload or magnitude of cyclic axial or torsional testing affected the ability to detect minor AF defects in rat caudal motion segments using ex vivo biomechanical testing. Intact and injured motion segments were subjected to a repeated measures study design with multiple biomechanical testing protocols that varied axial tension-compression force amplitude (±1.6 N, ±8.0 N, ±16.0 N), axial preload (-1.6 N, -8.0 N, -16.0 N, corresponding to -0.1 MPa, -0.5 MPa, and -1.0 MPa, respectively), and torsional rotation angle (±10°, ±15°, and ±20°). Biomechanical properties obtained from the lowest force testing conditions for axial tension-compression (±1.6 N), axial preload (-1.6 N), and angular rotation (±10°) exhibited the largest differences in biomechanical properties between intact and injured conditions. Biomechanical properties determined under low axial force or torsion amplitudes involve less AF fiber tension and were most sensitive to injury. Low force testing protocols are recommended for detecting minor structural AF defects and may enable more precise assessments of IVD injuries, healing or repair.
journal_name
J Mech Behav Biomed Materauthors
Torre OM,Evashwick-Rogler TW,Nasser P,Iatridis JCdoi
10.1016/j.jmbbm.2019.03.024subject
Has Abstractpub_date
2019-07-01 00:00:00pages
13-20eissn
1751-6161issn
1878-0180pii
S1751-6161(18)31609-6journal_volume
95pub_type
杂志文章abstract::A newly designed hydroxyapatite-polyurethane (HA-PU) composite scaffold was prepared by polymerizing glyceride of castor oil (GCO) with isophorone diisocyanate (IPDI) and HA as fillers. The aim of this study was to determine the effect of HA fillers on the mechanical properties and osteogenesis capacity of the composi...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.08.028
更新日期:2018-12-01 00:00:00
abstract::The passive micro-structural mechanical response of muscle tissue is important for numerous medical applications. However, the recently observed tension/compression asymmetry in porcine muscle remains poorly explained. In particular there remains a lack of understanding of how external tension or compression applied i...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.08.019
更新日期:2014-12-01 00:00:00
abstract::Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.04.018
更新日期:2012-09-01 00:00:00
abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.12.020
更新日期:2017-05-01 00:00:00
abstract::The tension-compression switch hypothesis for soft tissue proposes that when collagen fibres are compressed they do not contribute to the mechanical response which is then assumed to be the isotropic response of the extra-cellular matrix in which they are embedded. Such an assumption would seem reasonable. However, th...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103558
更新日期:2020-03-01 00:00:00
abstract:OBJECTIVES:The causes of in vivo fractures of all-ceramic dental crowns are not yet fully understood. The fracture origins often occur in the cervical margin in the approximal area, but the reason for this is unclear. The aim of this study was to evaluate the fracture origin of 22 of clinically-failed alumina crowns. ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.08.006
更新日期:2016-01-01 00:00:00
abstract::With the aim to prepare antibacterial acrylic bone cements, a series of imidazolium-containg mono-methacrylates with N-alkyl chain length varied from 10 to 18 (MEIM-x) were synthesized as polymerizable antibacterial agents through a two-step reaction. The structures of the monomers were confirmed by 1H NMR. Methyl met...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.06.003
更新日期:2017-10-01 00:00:00
abstract::An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency depe...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.08.010
更新日期:2012-03-01 00:00:00
abstract::The hierarchical architecture of the collagen fibril is well understood, involving non-integer staggering of collagen molecules which results in a 67 nm periodic molecular density variation termed D-banding. Other than this variation, collagen fibrils are considered to be homogeneous at the micro-scale and beyond. Int...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103849
更新日期:2020-10-01 00:00:00
abstract::In previous studies, enamel showed indications to occlude small cracks in-vivo and exhibited R-curve behaviors for bigger cracks ex-vivo. This study quantifies the crack tip's toughness (K(I0),K(III0)), the crack's closure stress and the cohesive zone size at the crack tip of enamel and investigates the toughening mec...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2010.12.003
更新日期:2011-04-01 00:00:00
abstract::The finite element analysis is an accepted method to predict vertebral body compressive strength. This study compares measurements obtained from in vitro tests with the ones from two different simulation models: clinical quantitative computer tomography (QCT) based homogenized finite element (hFE) models and pre-clini...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.11.018
更新日期:2014-05-01 00:00:00
abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.09.025
更新日期:2015-12-01 00:00:00
abstract::The cornea, through its shape, is the main contributor to the eye׳s focusing power. Pathological alterations of the cornea strongly affect the eye power. To improve treatments, complex biomechanical models have been developed based on the architecture and mechanical properties of the collagen network in the stroma, th...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.031
更新日期:2016-07-01 00:00:00
abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.010
更新日期:2011-10-01 00:00:00
abstract::In 3DP fabricating artificial bone scaffolds process, the interaction mechanism between binder and bioceramics power determines the microstructure and macro mechanical properties of Hydroxyapatite (HA) bone scaffold. In this study, we applied Molecular Dynamics (MD) methods to investigating the bonding mechanism and e...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.007
更新日期:2016-04-01 00:00:00
abstract::This study evaluated the effects of two types of superstructures (splinted crown and non-splinted crown) on four vibration characteristics (natural frequency, damping ratio (DAR), vectors in antiphase, maximum displacement (MDP)) by using modal analysis. These structures were fabricated on three implants placed in the...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104050
更新日期:2020-12-01 00:00:00
abstract::This paper presents the results of an experimental study of the adhesion forces between components of model conjugated magnetite nanoparticle systems for improved selectivity in the specific targeting of triple negative breast cancer. Adhesion forces between chemically synthesized magnetite nanoparticles (CMNPs), bios...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.02.004
更新日期:2017-04-01 00:00:00
abstract::Although clinical bone fractures occur predominantly under impact loading (as occurs during sporting accidents, falls, high-speed impacts or other catastrophic events), experimentally validated studies on the dynamic fracture behavior of bone, at the loading rates associated with such events, remain limited. In this s...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2010.09.006
更新日期:2011-01-01 00:00:00
abstract::Considering the interest of the research community in the fatigue behavior of all-ceramic restorations and the time consumed in low-frequency cyclic fatigue tests, this study aimed to investigate the influence of the loading frequency on the zirconia fatigue strength. The biaxial flexural fatigue strength of Y-TZP dis...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.01.008
更新日期:2016-08-01 00:00:00
abstract::Biocompatible Zinc-hydroxyapatite-titania and Zinc-hydroxyapatite nanocomposite coatings have been prepared by electrodeposition on NiTi shape memory alloy. Structures of coatings were characterized using X-ray diffraction (XRD). It was found that addition of TiO2 particles cause to reduction of crystallite size of co...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.05.016
更新日期:2016-09-01 00:00:00
abstract::We previously described the gelation mechanism of calcium polyphosphate (CPP) in the presence of water. In this study, we developed novel and injectable poly-dicalcium phosphate dihydrate (P-DCPD) forming cement by the reaction of acidic CPP gel with alkali tetracalcium phosphate (TTCP). The setting reaction mechanism...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.12.032
更新日期:2018-03-01 00:00:00
abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103388
更新日期:2019-12-01 00:00:00
abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.03.030
更新日期:2017-07-01 00:00:00
abstract::The inelastic deformability of the mineralised matrix in bones is critical to their high toughness, but the nanoscale mechanisms are incompletely understood. Antler is a tough bone type, with a nanostructure composed of mineralised collagen fibrils ∼100nm diameter. We track the fibrillar deformation of antler tissue d...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.03.020
更新日期:2013-12-01 00:00:00
abstract::Even though bariatric surgery is one of the most effective treatment option of obesity, post-surgical weight loss is not always ensured, especially in the long term, when many patients experience weight regain. Bariatric procedures are largely based on surgeon's expertise and intra-operative decisions, while an integr...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103883
更新日期:2020-10-01 00:00:00
abstract::Anterior cruciate ligament (ACL) is a key fibrous connective tissue that maintains the stability of a knee joint and it is the most commonly injured ligament of the knee. A synthetic prosthesis in the form of a braided structure can be an attractive alternative to biological grafts provided that the mechanical propert...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.09.018
更新日期:2016-02-01 00:00:00
abstract::Laser surface melting (LSM) of Ti6Al4V alloy was carried out with an aim to improve properties such as microstructure and wear for implant applications. The alloy substrate was melted at 250W and 400W at a scan velocity of 5mm/s, with input energy of 42J/mm(2) and 68J/mm(2), respectively. The results showed that equia...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.12.001
更新日期:2014-04-01 00:00:00
abstract::In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co-Cr-Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103706
更新日期:2020-05-01 00:00:00
abstract::The mechanical reliability of calcium phosphate cements has restricted their clinical application in load-bearing locations. Although their mechanical strength can be improved using a variety of strategies, their fatigue properties are still unclear, especially after degradation. The evolutions of uniaxial compressive...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.07.026
更新日期:2017-11-01 00:00:00
abstract::This aim of this study is to determine the elastoplastic properties of Ni-free Al3FeSi2 intermetallic coatings grown on medical stainless steel under different experimental conditions. Elastoplastic properties are defined by the plasticity index (PI), which correlates the hardness and the Young's modulus. Special emph...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.02.018
更新日期:2015-06-01 00:00:00