Comparison of 68Ga-DOTA-Siglec-9 and 18F-Fluorodeoxyribose-Siglec-9: Inflammation Imaging and Radiation Dosimetry.

Abstract:

:Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a ligand of inflammation-inducible vascular adhesion protein-1 (VAP-1). We compared 68Ga-DOTA- and 18F-fluorodeoxyribose- (FDR-) labeled Siglec-9 motif peptides for PET imaging of inflammation. Methods. Firstly, we examined 68Ga-DOTA-Siglec-9 and 18F-FDR-Siglec-9 in rats with skin/muscle inflammation. We then studied 18F-FDR-Siglec-9 for the detection of inflamed atherosclerotic plaques in mice and compared it with previous 68Ga-DOTA-Siglec-9 results. Lastly, we estimated human radiation dosimetry from the rat data. Results. In rats, 68Ga-DOTA-Siglec-9 (SUV, 0.88 ± 0.087) and 18F-FDR-Siglec-9 (SUV, 0.77 ± 0.22) showed comparable (P = 0.29) imaging of inflammation. In atherosclerotic mice, 18F-FDR-Siglec-9 detected inflamed plaques with a target-to-background ratio (1.6 ± 0.078) similar to previously tested 68Ga-DOTA-Siglec-9 (P = 0.35). Human effective dose estimates for 68Ga-DOTA-Siglec-9 and 18F-FDR-Siglec-9 were 0.024 and 0.022 mSv/MBq, respectively. Conclusion. Both tracers are suitable for PET imaging of inflammation. The easier production and lower cost of 68Ga-DOTA-Siglec-9 present advantages over 18F-FDR-Siglec-9, indicating it as a primary choice for clinical studies.

authors

Virtanen H,Silvola JMU,Autio A,Li XG,Liljenbäck H,Hellberg S,Siitonen R,Ståhle M,Käkelä M,Airaksinen AJ,Helariutta K,Tolvanen T,Veres TZ,Saraste A,Knuuti J,Jalkanen S,Roivainen A

doi

10.1155/2017/7645070

subject

Has Abstract

pub_date

2017-12-31 00:00:00

pages

7645070

eissn

1555-4309

issn

1555-4317

journal_volume

2017

pub_type

杂志文章
  • Synthesis and Evaluation of 18F-Labeled Peptide for Gonadotropin-Releasing Hormone Receptor Imaging.

    abstract::The gonadotropin-releasing hormone (GnRH) receptor is overexpressed in the majority of tumors of the human reproductive system. The purpose of this study was to develop an 18F-labeled peptide for tumor GnRH receptor imaging. In this study, the GnRH (pGlu1-His2-Trp3-Ser4-Tyr5-Gly6-Leu7-Arg8-Pro9-Gly10-NH2) peptide anal...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/5635269

    authors: Huang S,Li H,Han Y,Fu L,Ren Y,Zhang Y,Li Y,Sun P,Wang M,Wu H,Wang Q,Hu K

    更新日期:2019-03-07 00:00:00

  • Use of 18F-FDG-PET/CT for Retroperitoneal/Intra-Abdominal Soft Tissue Sarcomas.

    abstract:Rationale:To assess the diagnostic value of 18F-FDG-PET/CT for different retroperitoneal soft tissue sarcomas (STS) and other similar tumors. To analyze the predictive value of 18F-FDG-PET/CT for histological grade and main prognostic factors. Methods:195 patients with 44 different diseases have been included. Relatio...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/2601281

    authors: Liu DN,Li ZW,Wang HY,Zhao M,Zhao W,Hao CY

    更新日期:2018-07-02 00:00:00

  • Labeling of multiple cell lines using a new iron oxide agent for cell tracking by MRI.

    abstract::Stem cells, cancer cells and immune cells were labeled by co-incubation with a new ultra-small iron oxide nanoparticle called Molday ION Rhodamine-B (MIRB). Iron staining, fluorescence imaging, transmission electron microscopy and flow cytometry were used to assess cell viability, function and labeling efficiency. Thi...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.456

    authors: McFadden C,Mallett CL,Foster PJ

    更新日期:2011-11-01 00:00:00

  • An imageable retinoid acid derivative to detect human cancer xenografts and study therapeutic dosing to reduce its toxicity.

    abstract::Developing agents with 'seek, treat and see' capability is critical for personalized molecular medicine. Those agents will specifically target the disease markers for diagnosis and apply the biologically effective dose for treatment. Retinoids regulate a multitude of biological processes. In addition, retinoic acid ca...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.419

    authors: Wang W,Qiu X,Zhang F,Sun J,Cameron AG,Wendt JA,Mawad ME,Ke S

    更新日期:2011-07-01 00:00:00

  • Influence of cell-internalization on relaxometric, optical and compositional properties of targeted paramagnetic quantum dot micelles.

    abstract::Quantum dot micelles (pQDs) with a paramagnetic coating are promising nanoparticles for bimodal molecular imaging. Their bright fluorescence allows for optical detection, while their Gd payload enables visualization with contrast-enhanced MRI. A popular approach in molecular MRI is the targeting of abundantly expresse...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.411

    authors: Starmans LW,Kok MB,Sanders HM,Zhao Y,Donegá Cde M,Meijerink A,Mulder WJ,Grüll H,Strijkers GJ,Nicolay K

    更新日期:2011-03-01 00:00:00

  • Ferumoxides-protamine sulfate is more effective than ferucarbotran for cell labeling: implications for clinically applicable cell tracking using MRI.

    abstract::The use of superparamagnetic iron oxide (SPIO) for labeling cells holds great promise for clinically applicable cell tracking using magnetic resonance imaging. For clinical application, an effectively and specifically labeled cell preparation is highly desired (i.e. a large amount of intracellular iron and a negligibl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.289

    authors: van Buul GM,Farrell E,Kops N,van Tiel ST,Bos PK,Weinans H,Krestin GP,van Osch GJ,Bernsen MR

    更新日期:2009-09-01 00:00:00

  • Brain Tumor Diagnostics and Therapeutics with Superparamagnetic Ferrite Nanoparticles.

    abstract::Ferrite nanoparticles (F-NPs) can transform both cancer diagnostics and therapeutics. Superparamagnetic F-NPs exhibit high magnetic moment and susceptibility such that in presence of a static magnetic field transverse relaxation rate of water protons for MRI contrast is augmented to locate F-NPs (i.e., diagnostics) an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2017/6387217

    authors: Hyder F,Manjura Hoque S

    更新日期:2017-12-11 00:00:00

  • Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    abstract::Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have lim...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1578

    authors: Clavijo Jordan MV,Beeman SC,Baldelomar EJ,Bennett KM

    更新日期:2014-09-01 00:00:00

  • Influence of paramagnetic melanin on the MRI contrast in melanoma: a combined high-field (11.7 T) MRI and EPR study.

    abstract::Melanoma is the most dangerous form of skin cancer and its incidence is rising each year. Because the current methods of diagnosis based on the visual aspect of the tumor show limitations, several new techniques are emerging to help in this diagnosis, amongst which are magnetic resonance imaging (MRI) and electron par...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1554

    authors: Godechal Q,Mignion L,Karroum O,Magat J,Danhier P,Morandini R,Ghanem GE,Leveque P,Gallez B

    更新日期:2014-03-01 00:00:00

  • Variations in labeling protocol influence incorporation, distribution and retention of iron oxide nanoparticles into human umbilical vein endothelial cells.

    abstract::Various studies have shown that various cell types can be labeled with iron oxide particles and visualized by magnetic resonance imaging (MRI). However, reported protocols for cell labeling show a large variation in terms of labeling dose and incubation time. It is therefore not clear how different labeling protocols ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.379

    authors: van Tiel ST,Wielopolski PA,Houston GC,Krestin GP,Bernsen MR

    更新日期:2010-09-01 00:00:00

  • Superparamagnetic iron oxide nanoparticles conjugated to a grass pollen allergen and an optical probe.

    abstract::In this study we report the development of a bioconjugate between superparamagnetic iron oxide nanoparticles and Phl p5a (one of the major allergens from grass pollen). The bioconjugate also contains an optical probe (Alexa647) conjugated to the nanoparticle via biotin-streptavidin association. We show that this conju...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1466

    authors: Herranz F,Schmidt-Weber CB,Shamji MH,Narkus A,Ruiz-Cabello J,Vilar R

    更新日期:2012-07-01 00:00:00

  • 99mTc-Radiolabeled TPGS Nanomicelles Outperform 99mTc-Sestamibi as Breast Cancer Imaging Agent.

    abstract::D-α-Tocopheryl polyethylene glycol 1000 succinate (TPGS) is a Food and Drug Administration (FDA) approved biomaterial that can form nanosized micelles in aqueous solution. TPGS micelles stand as an interesting system to perform drug delivery as they can carry lipophilic drugs and overcome P glycoprotein efflux as well...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/4087895

    authors: Tesan FC,Nicoud MB,Nuñez M,Medina VA,Chiappetta DA,Salgueiro MJ

    更新日期:2019-04-23 00:00:00

  • Preclinical Imaging Biomarkers for Postischaemic Neurovascular Remodelling.

    abstract::In the pursuit of understanding the pathological alterations that underlie ischaemic injuries, such as vascular remodelling and reorganisation, there is a need for recognising the capabilities and limitations of in vivo imaging techniques. Thus, this review presents contemporary published research of imaging modalitie...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2019/3128529

    authors: Gandhi R,Tsoumpas C

    更新日期:2019-02-03 00:00:00

  • Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes?

    abstract::Targeted magnetic resonance contrast agents (e.g. iron oxide nanoparticles) have the potential to become highly selective imaging tools. In this context, quantification of the coupled amount of protein is essential for the design of antibody- or antibody fragment-conjugated nanoparticles. Nevertheless, the presence of...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.405

    authors: Rimkus G,Bremer-Streck S,Grüttner C,Kaiser WA,Hilger I

    更新日期:2011-05-01 00:00:00

  • Surgical tissue handling methods to optimize ex vivo fluorescence with the activatable optical probe γ-glutamyl hydroxymethyl rhodamine green.

    abstract::Optical fluorescence imaging has been developed as an aid to intraoperative diagnosis to improve surgical and endoscopic procedures. Compared with other intraoperative imaging methods, it is lower in cost, has a high safety margin, is portable and easy to use. γ-glutamyl hydroxymethyl rhodamine green (gGlu-HMRG) is a ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1705

    authors: Harada T,Nakamura Y,Sato K,Nagaya T,Choyke PL,Seto Y,Kobayashi H

    更新日期:2016-11-01 00:00:00

  • Parameters Influencing PET Imaging Features: A Phantom Study with Irregular and Heterogeneous Synthetic Lesions.

    abstract:Aim:To evaluate reproducibility and stability of radiomic features as effects of the use of different volume segmentation methods and reconstruction settings. The potential of radiomics in really capturing the presence of heterogeneous tumor uptake and irregular shape was also investigated. Materials and Methods:An an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/5324517

    authors: Gallivanone F,Interlenghi M,D'Ambrosio D,Trifirò G,Castiglioni I

    更新日期:2018-09-10 00:00:00

  • High-throughput screening of chemical exchange saturation transfer MR contrast agents.

    abstract::A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B(0)). This approach, which is applicable to diamagnetic, paramag...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.383

    authors: Liu G,Gilad AA,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2010-05-01 00:00:00

  • Real-time 3D MRI of contrast agents in whole living mice.

    abstract::A specific mouse whole body coil and a dedicated gradient system at 4.7 T were coupled with an ultra-fast 3D gradient echo MRI and keyhole reconstruction technique to obtain 3D whole-body dynamic T(1)-weighted or T(2)*-weighted imaging. The technique was used to visualize the real-time distribution of non-targeting T(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.429

    authors: Bled E,Hassen WB,Pourtau L,Mellet P,Lanz T,Schüler D,Voisin P,Franconi JM,Thiaudière E,Miraux S

    更新日期:2011-07-01 00:00:00

  • Contrast-Enhanced Microtomographic Characterisation of Vessels in Native Bone and Engineered Vascularised Grafts Using Ink-Gelatin Perfusion and Phosphotungstic Acid.

    abstract:Objectives:Bone ischemia and necrosis are challenging to treat, requiring investigation of native and engineered bone revascularisation processes through advanced imaging techniques. This study demonstrates an experimental two-step method for precise bone and vessel analysis in native bones or vascularised bone grafts ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/4035160

    authors: Sutter S,Todorov A,Ismail T,Haumer A,Fulco I,Schulz G,Scherberich A,Kaempfen A,Martin I,Schaefer DJ

    更新日期:2017-04-23 00:00:00

  • In vitro setup to study permeability characteristics of contrast agents by MRI.

    abstract::An experimental setup consisting of a hollow fiber module (HFM) was developed for the in vitro study of contrast agent (CA) permeability. Controllable flow and known fiber characteristics allowed permeability studies under well-defined conditions with CAs of different molecular weight (MW). In the MRI experiments perf...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.262

    authors: Heilmann M,Vautier J,Robert P,Volk A

    更新日期:2009-03-01 00:00:00

  • Multifunctional microbubbles and nanobubbles for photoacoustic imaging.

    abstract::Photoacoustic imaging is an emerging imaging modality for noninvasive detection of tissue structural and functional anomalies. Multifunctional microbubbles (MBs) and nanobubbles (NBs) are contrast agents integrating multiple disease-targeting, imaging and therapeutic functions. Multifunctional MBs and NBs represent an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1002/cmmi.442

    authors: Xu RX

    更新日期:2011-09-01 00:00:00

  • Construction and Evaluation of the Tumor-Targeting, Cell-Penetrating Multifunctional Molecular Probe iCREKA.

    abstract::A novel tumor stroma targeting and membrane-penetrating cyclic peptide, named iCREKA, was designed and labeled by fluorescein isothiocyanate (FITC) and positron emitter 18F to build the tumor-targeting tracers. The FITC-iCREKA was proved to have significantly higher cellular uptake in the glioma U87 cells in the prese...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/7929617

    authors: Wang LJ,Li HS,Wang QS,Wu HB,Han YJ,Zhou WL,Wang M,Huang S

    更新日期:2018-03-04 00:00:00

  • Current Status and Future Perspectives of Artificial Intelligence in Magnetic Resonance Breast Imaging.

    abstract::Recent advances in artificial intelligence (AI) and deep learning (DL) have impacted many scientific fields including biomedical maging. Magnetic resonance imaging (MRI) is a well-established method in breast imaging with several indications including screening, staging, and therapy monitoring. The rapid development a...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2020/6805710

    authors: Meyer-Bäse A,Morra L,Meyer-Bäse U,Pinker K

    更新日期:2020-08-28 00:00:00

  • Ability of 18F-FDG PET/CT Radiomic Features to Distinguish Breast Carcinoma from Breast Lymphoma.

    abstract::Purpose. To investigate the value of SUV metrics and radiomic features based on the ability of 18F-FDG PET/CT in differentiating between breast lymphoma and breast carcinoma. Methods. A total of 67 breast nodules from 44 patients who underwent 18F-FDG PET/CT pretreatment were retrospectively analyzed. Radiomic paramet...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/4507694

    authors: Ou X,Wang J,Zhou R,Zhu S,Pang F,Zhou Y,Tian R,Ma X

    更新日期:2019-02-25 00:00:00

  • Effect of anesthesia carrier gas on in vivo circulation times of ultrasound microbubble contrast agents in rats.

    abstract:PURPOSE:Microbubble contrast agents are currently implemented in a variety of both clinical and preclinical ultrasound imaging studies. The therapeutic and diagnostic capabilities of these contrast agents are limited by their short in-vivo lifetimes, and research to lengthen their circulation times is on going. In this...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.414

    authors: Mullin L,Gessner R,Kwan J,Kaya M,Borden MA,Dayton PA

    更新日期:2011-05-01 00:00:00

  • Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    abstract::Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitativ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1569

    authors: Sun PZ,Wang Y,Dai Z,Xiao G,Wu R

    更新日期:2014-07-01 00:00:00

  • Connexin 43-targeted T1 contrast agent for MRI diagnosis of glioma.

    abstract::Glioblastoma multiforme is the most aggressive form of brain tumor. Early and accurate diagnosis of glioma and its borders is an important step for its successful treatment. One of the promising targets for selective visualization of glioma and its margins is connexin 43 (Cx43), which is highly expressed in reactive a...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1653

    authors: Abakumova T,Abakumov M,Shein S,Chelushkin P,Bychkov D,Mukhin V,Yusubalieva G,Grinenko N,Kabanov A,Nukolova N,Chekhonin V

    更新日期:2016-01-01 00:00:00

  • A fluorescent, paramagnetic and PEGylated gold/silica nanoparticle for MRI, CT and fluorescence imaging.

    abstract::An important challenge in medical diagnostics is to design all-in-one contrast agents that can be detected with multiple techniques such as magnetic resonance imaging (MRI), X-ray computed tomography (CT), positron emission tomography (PET), single photon emission tomography (SPECT) or fluorescence imaging (FI). Altho...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.376

    authors: van Schooneveld MM,Cormode DP,Koole R,van Wijngaarden JT,Calcagno C,Skajaa T,Hilhorst J,'t Hart DC,Fayad ZA,Mulder WJ,Meijerink A

    更新日期:2010-07-01 00:00:00

  • Uniform mesoporous silica coated iron oxide nanoparticles as a highly efficient, nontoxic MRI T(2) contrast agent with tunable proton relaxivities.

    abstract::Monodisperse mesoporous silica (mSiO(2) ) coated superparamagnetic iron oxide (Fe(3) O(4) @mSiO(2) ) nanoparticles (NPs) have been developed as a potential magnetic resonance imaging (MRI) T(2) contrast agent. To evaluate the effect of surface coating on MRI contrast efficiency, we examined the proton relaxivities of ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1473

    authors: Ye F,Laurent S,Fornara A,Astolfi L,Qin J,Roch A,Martini A,Toprak MS,Muller RN,Muhammed M

    更新日期:2012-09-01 00:00:00

  • Considerations for the clinical use of contrast agents for cellular MRI in regenerative medicine.

    abstract::Advances in regenerative medicine are rapidly transforming healthcare. A cornerstone of regenerative medicine is the introduction of cells that were grown or manipulated in vitro. Key questions that arise after these cells are re-introduced are: whether these cells are localized in the appropriate site; whether cells ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1002/cmmi.1547

    authors: Modo M,Kolosnjaj-Tabi J,Nicholls F,Ling W,Wilhelm C,Debarge O,Gazeau F,Clement O

    更新日期:2013-11-01 00:00:00