Multifunctional microbubbles and nanobubbles for photoacoustic imaging.

Abstract:

:Photoacoustic imaging is an emerging imaging modality for noninvasive detection of tissue structural and functional anomalies. Multifunctional microbubbles (MBs) and nanobubbles (NBs) are contrast agents integrating multiple disease-targeting, imaging and therapeutic functions. Multifunctional MBs and NBs represent an enabling technology for many potential applications in the field of photoacoustic imaging. Highly absorbing optical contrast agents, such as gold nanoparticles, India ink and Indocyanine Green, can be encapsulated in MBs and NBs for stable absorption properties and multimodal imaging contrasts. The surface of MBs and NBs can be modified for high disease-targeting affinity, reduced immunogenicity and prolonged circulation lifetime. Low boiling point perfluorocarbon compounds can be encapsulated in MBs and NBs for selective activation by external energy sources. The activation of these MBs and NBs may introduce significant contrast enhancement and facilitate a variety of potential clinical applications, such as image-guided drug delivery and therapeutic margin assessment. MB and NB enhanced photoacoustic imaging is still in its infancy. Further development and validation works are necessary for successful translation of the technology from the benchtop to the bedside.

authors

Xu RX

doi

10.1002/cmmi.442

subject

Has Abstract

pub_date

2011-09-01 00:00:00

pages

401-11

issue

5

eissn

1555-4309

issn

1555-4317

journal_volume

6

pub_type

杂志文章,评审
  • Magnetosomes Extracted from Magnetospirillum gryphiswaldense as Theranostic Agents in an Experimental Model of Glioblastoma.

    abstract::Magnetic fluid hyperthermia (MFH) with chemically synthesized nanoparticles is currently used in clinical trials as it destroys tumor cells with an extremely localized deposition of thermal energy. In this paper, we investigated an MFH protocol based on magnetic nanoparticles naturally produced by magnetotactic bacter...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/2198703

    authors: Mannucci S,Tambalo S,Conti G,Ghin L,Milanese A,Carboncino A,Nicolato E,Marinozzi MR,Benati D,Bassi R,Marzola P,Sbarbati A

    更新日期:2018-07-11 00:00:00

  • Analytical Interference by Contrast Agents in Biochemical Assays.

    abstract:Objective:To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods:The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29 most frequently perform...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/1323802

    authors: Otnes S,Fogh-Andersen N,Rømsing J,Thomsen HS

    更新日期:2017-04-10 00:00:00

  • Phenylboronate 160Tb complexes for molecular recognition of glycoproteins expressed on tumor cells.

    abstract::The over-expression of sialic acid on the surface of cancer cells compared with normal ones makes this nine-carbon sugar an attractive biomarker for molecular diagnosis and therapy. Here, we describe a study on the molecular recognition of sialic acid end groups on the surface of human glioma cells by (160)Tb-DTPA-EN(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.123

    authors: Djanashvili K,Koning GA,van der Meer AJ,Wolterbeek HT,Peters JA

    更新日期:2007-01-01 00:00:00

  • E-selectin targeting to visualize tumors in vivo.

    abstract::Generally angiogenic factors induce the expression of E-selectin in vascular endothelial cells in the tumors. In this study, we employed an anti-E-selectin monoclonal antibody to target tumors in vivo and evaluated an optical imaging reagent to visualize tumor regions. The anti-E-selectin antibody was conjugated on th...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.367

    authors: Hirai M,Hiramatsu Y,Iwashita S,Otani T,Chen L,Li YG,Okada M,Oie K,Igarashi K,Wakita H,Seno M

    更新日期:2010-03-01 00:00:00

  • Corrigendum to "Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging".

    abstract::[This corrects the article DOI: 10.1155/2017/7368384.]. ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1155/2018/2165693

    authors: Tse JJ,Dunmore-Buyze PJ,Drangova M,Holdsworth DW

    更新日期:2018-08-23 00:00:00

  • Minimization of self-quenching fluorescence on dyes conjugated to biomolecules with multiple labeling sites via asymmetrically charged NIR fluorophores.

    abstract::Self-aggregation of dyes even at low concentrations poses a considerable challenge in preparing sufficiently bright molecular probes for in vivo imaging, particularly in the conjugation of near infrared cyanine dyes to polypeptides with multiple labeling sites. Such self-aggregation leads to a significant energy trans...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1585

    authors: Zhegalova NG,He S,Zhou H,Kim DM,Berezin MY

    更新日期:2014-09-01 00:00:00

  • Classification of acute and delayed contrast media-induced reactions: proposal of a three-step system.

    abstract::Physicians and scientists use a broad spectrum of terms to classify contrast media (CM)-induced adverse reactions. In particular, the designation of hypersensitivity reactions is quite varied. Consequently, comparisons of different papers dealing with this subject are difficult or even impossible. Moreover, general de...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1475

    authors: Böhm I,Heverhagen JT,Klose KJ

    更新日期:2012-11-01 00:00:00

  • Uniform mesoporous silica coated iron oxide nanoparticles as a highly efficient, nontoxic MRI T(2) contrast agent with tunable proton relaxivities.

    abstract::Monodisperse mesoporous silica (mSiO(2) ) coated superparamagnetic iron oxide (Fe(3) O(4) @mSiO(2) ) nanoparticles (NPs) have been developed as a potential magnetic resonance imaging (MRI) T(2) contrast agent. To evaluate the effect of surface coating on MRI contrast efficiency, we examined the proton relaxivities of ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1473

    authors: Ye F,Laurent S,Fornara A,Astolfi L,Qin J,Roch A,Martini A,Toprak MS,Muller RN,Muhammed M

    更新日期:2012-09-01 00:00:00

  • Antibody-functionalized nanoparticles for imaging cancer: influence of conjugation to gold nanoparticles on the biodistribution of 89Zr-labeled cetuximab in mice.

    abstract::Antibody-labeled gold nanoparticles represent a promising novel tool regarding cancer imaging and therapy. Nevertheless, the characterization of biodistribution of such immunonanocarriers has been poorly documented. In this study, the biodistribution of (89)Zr-labeled cetuximab before and after the coupling reaction t...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1539

    authors: Karmani L,Labar D,Valembois V,Bouchat V,Nagaswaran PG,Bol A,Gillart J,Levêque P,Bouzin C,Bonifazi D,Michiels C,Feron O,Grégoire V,Lucas S,Vander Borght T,Gallez B

    更新日期:2013-09-01 00:00:00

  • Surgical tissue handling methods to optimize ex vivo fluorescence with the activatable optical probe γ-glutamyl hydroxymethyl rhodamine green.

    abstract::Optical fluorescence imaging has been developed as an aid to intraoperative diagnosis to improve surgical and endoscopic procedures. Compared with other intraoperative imaging methods, it is lower in cost, has a high safety margin, is portable and easy to use. γ-glutamyl hydroxymethyl rhodamine green (gGlu-HMRG) is a ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1705

    authors: Harada T,Nakamura Y,Sato K,Nagaya T,Choyke PL,Seto Y,Kobayashi H

    更新日期:2016-11-01 00:00:00

  • VCAM-1-targeting gold nanoshell probe for photoacoustic imaging of atherosclerotic plaque in mice.

    abstract::The development of molecular probes and novel imaging modalities, allowing better resolution and specificity, is associated with an increased potential for molecular imaging of atherosclerotic plaques especially in basic and pre-clinical research applications. In that context, a photoacoustic molecular probe based on ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1491

    authors: Rouleau L,Berti R,Ng VW,Matteau-Pelletier C,Lam T,Saboural P,Kakkar AK,Lesage F,Rhéaume E,Tardif JC

    更新日期:2013-01-01 00:00:00

  • Labeling of multiple cell lines using a new iron oxide agent for cell tracking by MRI.

    abstract::Stem cells, cancer cells and immune cells were labeled by co-incubation with a new ultra-small iron oxide nanoparticle called Molday ION Rhodamine-B (MIRB). Iron staining, fluorescence imaging, transmission electron microscopy and flow cytometry were used to assess cell viability, function and labeling efficiency. Thi...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.456

    authors: McFadden C,Mallett CL,Foster PJ

    更新日期:2011-11-01 00:00:00

  • Spectroscopic, radiochemical, and theoretical studies of the Ga3+-N-2-hydroxyethyl piperazine-N'-2-ethanesulfonic acid (HEPES buffer) system: evidence for the formation of Ga3+ - HEPES complexes in (68) Ga labeling reactions.

    abstract::Recent reports have claimed a superior performance of HEPES buffer in comparison to alternative buffer systems for (67/68) Ga labeling in aqueous media. In this paper we report spectroscopic ((1) H and (71) Ga NMR), radiochemical, mass spectrometry and theoretical modeling studies on the Ga(3+)/HEPES system (HEPES = N...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1517

    authors: Martins AF,Prata MI,Rodrigues SP,Geraldes CF,Riss PJ,Amor-Coarasa A,Burchardt C,Kroll C,Roesch F

    更新日期:2013-05-01 00:00:00

  • Variations in labeling protocol influence incorporation, distribution and retention of iron oxide nanoparticles into human umbilical vein endothelial cells.

    abstract::Various studies have shown that various cell types can be labeled with iron oxide particles and visualized by magnetic resonance imaging (MRI). However, reported protocols for cell labeling show a large variation in terms of labeling dose and incubation time. It is therefore not clear how different labeling protocols ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.379

    authors: van Tiel ST,Wielopolski PA,Houston GC,Krestin GP,Bernsen MR

    更新日期:2010-09-01 00:00:00

  • Influence of paramagnetic melanin on the MRI contrast in melanoma: a combined high-field (11.7 T) MRI and EPR study.

    abstract::Melanoma is the most dangerous form of skin cancer and its incidence is rising each year. Because the current methods of diagnosis based on the visual aspect of the tumor show limitations, several new techniques are emerging to help in this diagnosis, amongst which are magnetic resonance imaging (MRI) and electron par...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1554

    authors: Godechal Q,Mignion L,Karroum O,Magat J,Danhier P,Morandini R,Ghanem GE,Leveque P,Gallez B

    更新日期:2014-03-01 00:00:00

  • Dynamic contrast-enhanced computed tomography for the quantification of tumor response to vasoactive agents in a rat tumor model: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this pilot study was to establish the ability of dynamic contrast enhanced computed tomography (DCE-CT) to detect changes in tumor blood flow (BF) and oxygenation induced by vasoactive substances in rats. MATERIALS AND METHODS:Under ultrasound guidance, a fiber-optic probe was g...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.399

    authors: Pollard RE,Larson RF

    更新日期:2011-01-01 00:00:00

  • Effect of anesthesia carrier gas on in vivo circulation times of ultrasound microbubble contrast agents in rats.

    abstract:PURPOSE:Microbubble contrast agents are currently implemented in a variety of both clinical and preclinical ultrasound imaging studies. The therapeutic and diagnostic capabilities of these contrast agents are limited by their short in-vivo lifetimes, and research to lengthen their circulation times is on going. In this...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.414

    authors: Mullin L,Gessner R,Kwan J,Kaya M,Borden MA,Dayton PA

    更新日期:2011-05-01 00:00:00

  • Ferumoxides-protamine sulfate is more effective than ferucarbotran for cell labeling: implications for clinically applicable cell tracking using MRI.

    abstract::The use of superparamagnetic iron oxide (SPIO) for labeling cells holds great promise for clinically applicable cell tracking using magnetic resonance imaging. For clinical application, an effectively and specifically labeled cell preparation is highly desired (i.e. a large amount of intracellular iron and a negligibl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.289

    authors: van Buul GM,Farrell E,Kops N,van Tiel ST,Bos PK,Weinans H,Krestin GP,van Osch GJ,Bernsen MR

    更新日期:2009-09-01 00:00:00

  • In vitro setup to study permeability characteristics of contrast agents by MRI.

    abstract::An experimental setup consisting of a hollow fiber module (HFM) was developed for the in vitro study of contrast agent (CA) permeability. Controllable flow and known fiber characteristics allowed permeability studies under well-defined conditions with CAs of different molecular weight (MW). In the MRI experiments perf...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.262

    authors: Heilmann M,Vautier J,Robert P,Volk A

    更新日期:2009-03-01 00:00:00

  • Gadobutrol Precedes Gd-DTPA in Abdominal Contrast-Enhanced MRA and MRI: A Prospective, Multicenter, Intraindividual Study.

    abstract:Objective:To qualitatively and quantitatively compare the contrast-enhanced magnetic resonance angiography (MRA) and magnetic resonance imaging (MRI) in one-stop shop of abdominal imaging with Gadobutrol and Gd-DTPA at equimolar doses of gadolinium. Materials and Methods:This was a prospective designed, multiple cente...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1155/2019/9738464

    authors: Liu X,Li Z,Zhang W,Yang C,Diao Y,Duan T,Fu Y,Ren J,Bin S

    更新日期:2019-12-02 00:00:00

  • A First Report on [18F]FPRGD2 PET/CT Imaging in Multiple Myeloma.

    abstract::An observational study was set up to assess the feasibility of [18F]FPRGD2 PET/CT for imaging patients with multiple myeloma (MM) and to compare its detection rate with low dose CT alone and combined [18F]NaF/[18F]FDG PET/CT images. Four patients (2 newly diagnosed patients and 2 with relapsed MM) were included and un...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/6162845

    authors: Withofs N,Cousin F,De Prijck B,Bonnet C,Hustinx R,Gambhir SS,Beguin Y,Caers J

    更新日期:2017-07-27 00:00:00

  • Diagnostic Performance of PET or PET/CT with Different Radiotracers in Patients with Suspicious Lung Cancer or Pleural Tumours according to Published Meta-Analyses.

    abstract:Purpose:Several meta-analyses have reported data about the diagnostic performance of positron emission tomography or positron emission tomography/computed tomography (PET or PET/CT) with different radiotracers in patients with suspicious lung cancer (LC) or pleural tumours (PT). This review article aims at providing an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2020/5282698

    authors: Lococo F,Muoio B,Chiappetta M,Nachira D,Petracca Ciavarella L,Margaritora S,Treglia G

    更新日期:2020-04-25 00:00:00

  • Preclinical Imaging Biomarkers for Postischaemic Neurovascular Remodelling.

    abstract::In the pursuit of understanding the pathological alterations that underlie ischaemic injuries, such as vascular remodelling and reorganisation, there is a need for recognising the capabilities and limitations of in vivo imaging techniques. Thus, this review presents contemporary published research of imaging modalitie...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2019/3128529

    authors: Gandhi R,Tsoumpas C

    更新日期:2019-02-03 00:00:00

  • Dynamic manganese-enhanced magnetic resonance imaging can detect chronic cryoinjury-induced infarction in pig hearts in vivo.

    abstract::The purpose was to investigate whether MnCl(2) can serve as an MRI contrast agent to detect chronic cryoinjury infarction in pigs in vivo and whether MnCl(2) causes significant hemodynamic disturbances. Hearts were subjected to a topical 2 min cryothermia to establish myocardial infarction (MI). Thereafter GdDTPA-enha...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.438

    authors: Yang Y,de Gervai PD,Sun J,Gruwel ML,Kupriyanov V

    更新日期:2011-11-01 00:00:00

  • Ability of 18F-FDG PET/CT Radiomic Features to Distinguish Breast Carcinoma from Breast Lymphoma.

    abstract::Purpose. To investigate the value of SUV metrics and radiomic features based on the ability of 18F-FDG PET/CT in differentiating between breast lymphoma and breast carcinoma. Methods. A total of 67 breast nodules from 44 patients who underwent 18F-FDG PET/CT pretreatment were retrospectively analyzed. Radiomic paramet...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/4507694

    authors: Ou X,Wang J,Zhou R,Zhu S,Pang F,Zhou Y,Tian R,Ma X

    更新日期:2019-02-25 00:00:00

  • Assessment of the biodistribution of an [(18) F]FDG-loaded perfluorocarbon double emulsion using dynamic micro-PET in rats.

    abstract::Perfluorocarbon (PFC) double emulsions loaded with a water-soluble, therapeutic agent can be triggered by ultrasound in a process known as acoustic droplet vaporization. Elucidating the stability and biodistribution of these sonosensitive vehicles and encapsulated agents is critical in developing targeted drug deliver...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1532

    authors: Fabiilli ML,Piert MR,Koeppe RA,Sherman PS,Quesada CA,Kripfgans OD

    更新日期:2013-07-01 00:00:00

  • Thermodynamic stability and kinetic inertness of a Gd-DTPA bisamide complex grafted onto gold nanoparticles.

    abstract::Gold nanoparticles coated by gadolinium (III) chelates (Au@DTDTPA) where DTDTPA is a dithiolated bisamide derivative of diethylenetriamine-N,N,N',N'',N''-pentaacetic acid (DTPA), constituted contrast agents for both X-ray computed tomography and magnetic resonance imaging. In an MRI context, highly stable Gd(3+) compl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1616

    authors: Mogilireddy V,Déchamps-Olivier I,Alric C,Laurent G,Laurent S,Vander Elst L,Muller R,Bazzi R,Roux S,Tillement O,Chuburu F

    更新日期:2015-05-01 00:00:00

  • Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    abstract::Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have lim...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1578

    authors: Clavijo Jordan MV,Beeman SC,Baldelomar EJ,Bennett KM

    更新日期:2014-09-01 00:00:00

  • Early Prediction of Treatment Response of Neuroendocrine Hepatic Metastases after Peptide Receptor Radionuclide Therapy with 90Y-DOTATOC Using Diffusion Weighted and Dynamic Contrast-Enhanced MRI.

    abstract::The purpose of this study was to determine if parameters derived from diffusion-weighted (DW-) and dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) can help to assess early response to peptide receptor radionuclide therapy (PRRT) with 90Y-DOTATOC in neuroendocrine hepatic metastases (NET-HM). Twenty p...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/1517208

    authors: Weikert T,Maas OC,Haas T,Klarhöfer M,Bremerich J,Forrer F,Sauter AW,Sommer G

    更新日期:2019-11-11 00:00:00

  • Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability.

    abstract:Background:To investigate same day 18F-FDG (Fluorodeoxyglucose) PET (Positron Emission Tomography)/MR (Magnetic Resonance) test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV) and lean body mass (SUL) in different locations in the liver. Methods:This prospective study wa...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/8639731

    authors: Domachevsky L,Bernstine H,Nidam M,Stein D,Goldberg N,Stern D,Abadi-Korek I,Groshar D

    更新日期:2017-05-30 00:00:00