Preclinical Imaging Biomarkers for Postischaemic Neurovascular Remodelling.

Abstract:

:In the pursuit of understanding the pathological alterations that underlie ischaemic injuries, such as vascular remodelling and reorganisation, there is a need for recognising the capabilities and limitations of in vivo imaging techniques. Thus, this review presents contemporary published research of imaging modalities that have been implemented to study postischaemic neurovascular changes in small animals. A comparison of the technical aspects of the various imaging tools is included to set the framework for identifying the most appropriate methods to observe postischaemic neurovascular remodelling. A systematic search of the PubMed® and Elsevier's Scopus databases identified studies that were conducted between 2008 and 2018 to explore postischaemic neurovascular remodelling in small animal models. Thirty-five relevant in vivo imaging studies are included, of which most made use of magnetic resonance imaging or positron emission tomography, whilst various optical modalities were also utilised. Notably, there is an increasing trend of using multimodal imaging to exploit the most beneficial properties of each imaging technique to elucidate different aspects of neurovascular remodelling. Nevertheless, there is still scope for further utilising noninvasive imaging tools such as contrast agents or radiotracers, which will have the ability to monitor neurovascular changes particularly during restorative therapy. This will facilitate more successful utility of the clinical imaging techniques in the interpretation of neurovascular reorganisation over time.

authors

Gandhi R,Tsoumpas C

doi

10.1155/2019/3128529

subject

Has Abstract

pub_date

2019-02-03 00:00:00

pages

3128529

eissn

1555-4309

issn

1555-4317

journal_volume

2019

pub_type

杂志文章,评审
  • Multifunctional microbubbles and nanobubbles for photoacoustic imaging.

    abstract::Photoacoustic imaging is an emerging imaging modality for noninvasive detection of tissue structural and functional anomalies. Multifunctional microbubbles (MBs) and nanobubbles (NBs) are contrast agents integrating multiple disease-targeting, imaging and therapeutic functions. Multifunctional MBs and NBs represent an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1002/cmmi.442

    authors: Xu RX

    更新日期:2011-09-01 00:00:00

  • Contrast-Enhanced MicroCT for Virtual 3D Anatomical Pathology of Biological Tissues: A Literature Review.

    abstract::To date, the combination of histological sectioning, staining, and microscopic assessment of the 2D sections is still the golden standard for structural and compositional analysis of biological tissues. X-ray microfocus computed tomography (microCT) is an emerging 3D imaging technique with high potential for 3D struct...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2019/8617406

    authors: de Bournonville S,Vangrunderbeeck S,Kerckhofs G

    更新日期:2019-02-28 00:00:00

  • Multimodal approach to assess tumour vasculature and potential treatment effect with DCE-US and DCE-MRI quantification in CWR22 prostate tumour xenografts.

    abstract::The aim of this study was to compare intratumoural heterogeneity and longitudinal changes assessed by dynamic contrast-enhanced ultrasound (DCE-US) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in prostate tumour xenografts. In vivo DCE-US and DCE-MRI were obtained 24 h pre- (day 0) and post- (day...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1645

    authors: Arteaga-Marrero N,Rygh CB,Mainou-Gomez JF,Nylund K,Roehrich D,Heggdal J,Matulaniec P,Gilja OH,Reed RK,Svensson L,Lutay N,Olsen DR

    更新日期:2015-11-01 00:00:00

  • Functionalization of Gadolinium Chelates Silica Nanoparticle through Silane Chemistry for Simultaneous MRI/64Cu PET Imaging.

    abstract::Multimodal nanoprobes are highly demanded for biomedical imaging applications to enhance the reliability of the diagnostic results. Among different types of nano-objects, ultrasmall silica gadolinium nanoparticle (SiGdNP) appears as a safe, effective, and versatile platform for this purpose. In this study, a new metho...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/7938267

    authors: Tran VL,Thakare V,Natuzzi M,Moreau M,Oudot A,Vrigneaud JM,Courteau A,Louis C,Roux S,Boschetti F,Denat F,Tillement O,Lux F

    更新日期:2018-11-01 00:00:00

  • Effect of anesthesia carrier gas on in vivo circulation times of ultrasound microbubble contrast agents in rats.

    abstract:PURPOSE:Microbubble contrast agents are currently implemented in a variety of both clinical and preclinical ultrasound imaging studies. The therapeutic and diagnostic capabilities of these contrast agents are limited by their short in-vivo lifetimes, and research to lengthen their circulation times is on going. In this...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.414

    authors: Mullin L,Gessner R,Kwan J,Kaya M,Borden MA,Dayton PA

    更新日期:2011-05-01 00:00:00

  • Classification of acute and delayed contrast media-induced reactions: proposal of a three-step system.

    abstract::Physicians and scientists use a broad spectrum of terms to classify contrast media (CM)-induced adverse reactions. In particular, the designation of hypersensitivity reactions is quite varied. Consequently, comparisons of different papers dealing with this subject are difficult or even impossible. Moreover, general de...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1475

    authors: Böhm I,Heverhagen JT,Klose KJ

    更新日期:2012-11-01 00:00:00

  • A First Report on [18F]FPRGD2 PET/CT Imaging in Multiple Myeloma.

    abstract::An observational study was set up to assess the feasibility of [18F]FPRGD2 PET/CT for imaging patients with multiple myeloma (MM) and to compare its detection rate with low dose CT alone and combined [18F]NaF/[18F]FDG PET/CT images. Four patients (2 newly diagnosed patients and 2 with relapsed MM) were included and un...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/6162845

    authors: Withofs N,Cousin F,De Prijck B,Bonnet C,Hustinx R,Gambhir SS,Beguin Y,Caers J

    更新日期:2017-07-27 00:00:00

  • Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes?

    abstract::Targeted magnetic resonance contrast agents (e.g. iron oxide nanoparticles) have the potential to become highly selective imaging tools. In this context, quantification of the coupled amount of protein is essential for the design of antibody- or antibody fragment-conjugated nanoparticles. Nevertheless, the presence of...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.405

    authors: Rimkus G,Bremer-Streck S,Grüttner C,Kaiser WA,Hilger I

    更新日期:2011-05-01 00:00:00

  • Optimizing quantitative in vivo fluorescence imaging with near-infrared quantum dots.

    abstract::Quantum dots (QDs) are fluorescent nanoparticles with broad excitation and narrow, wavelength-tunable emission spectra. They are used extensively for in vitro fluorescence imaging studies and more recently for in vivo small animal and pre-clinical studies. To date there has been little concern about the selection of Q...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.409

    authors: Rosenblum LT,Kosaka N,Mitsunaga M,Choyke PL,Kobayashi H

    更新日期:2011-05-01 00:00:00

  • Thermodynamic stability and kinetic inertness of a Gd-DTPA bisamide complex grafted onto gold nanoparticles.

    abstract::Gold nanoparticles coated by gadolinium (III) chelates (Au@DTDTPA) where DTDTPA is a dithiolated bisamide derivative of diethylenetriamine-N,N,N',N'',N''-pentaacetic acid (DTPA), constituted contrast agents for both X-ray computed tomography and magnetic resonance imaging. In an MRI context, highly stable Gd(3+) compl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1616

    authors: Mogilireddy V,Déchamps-Olivier I,Alric C,Laurent G,Laurent S,Vander Elst L,Muller R,Bazzi R,Roux S,Tillement O,Chuburu F

    更新日期:2015-05-01 00:00:00

  • Contrast-Enhanced Microtomographic Characterisation of Vessels in Native Bone and Engineered Vascularised Grafts Using Ink-Gelatin Perfusion and Phosphotungstic Acid.

    abstract:Objectives:Bone ischemia and necrosis are challenging to treat, requiring investigation of native and engineered bone revascularisation processes through advanced imaging techniques. This study demonstrates an experimental two-step method for precise bone and vessel analysis in native bones or vascularised bone grafts ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/4035160

    authors: Sutter S,Todorov A,Ismail T,Haumer A,Fulco I,Schulz G,Scherberich A,Kaempfen A,Martin I,Schaefer DJ

    更新日期:2017-04-23 00:00:00

  • Hepatic 18F-FDG Uptake Measurements on PET/MR: Impact of Volume of Interest Location on Repeatability.

    abstract:Background:To investigate same day 18F-FDG (Fluorodeoxyglucose) PET (Positron Emission Tomography)/MR (Magnetic Resonance) test-retest repeatability of Standardized Uptake Value measurements normalized for body weight (SUV) and lean body mass (SUL) in different locations in the liver. Methods:This prospective study wa...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/8639731

    authors: Domachevsky L,Bernstine H,Nidam M,Stein D,Goldberg N,Stern D,Abadi-Korek I,Groshar D

    更新日期:2017-05-30 00:00:00

  • Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    abstract::Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1695

    authors: Kingston MJ,Perriman DM,Neeman T,Smith PN,Webb AL

    更新日期:2016-07-01 00:00:00

  • Superparamagnetic iron oxide nanoparticles conjugated to a grass pollen allergen and an optical probe.

    abstract::In this study we report the development of a bioconjugate between superparamagnetic iron oxide nanoparticles and Phl p5a (one of the major allergens from grass pollen). The bioconjugate also contains an optical probe (Alexa647) conjugated to the nanoparticle via biotin-streptavidin association. We show that this conju...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1466

    authors: Herranz F,Schmidt-Weber CB,Shamji MH,Narkus A,Ruiz-Cabello J,Vilar R

    更新日期:2012-07-01 00:00:00

  • Synthesis and in vitro evaluation of MR molecular imaging probes using J591 mAb-conjugated SPIONs for specific detection of prostate cancer.

    abstract::Carcinoma of the prostate is the most frequent diagnosed malignant tumor in men and is the second leading cause of cancer-related death in this group. The cure rate of prostate cancer is highly dependent on the stage of disease at the diagnosis and early detection is key to designing effective treatment strategies. Th...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1514

    authors: Abdolahi M,Shahbazi-Gahrouei D,Laurent S,Sermeus C,Firozian F,Allen BJ,Boutry S,Muller RN

    更新日期:2013-03-01 00:00:00

  • Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    abstract::Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitativ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1569

    authors: Sun PZ,Wang Y,Dai Z,Xiao G,Wu R

    更新日期:2014-07-01 00:00:00

  • High-throughput screening of chemical exchange saturation transfer MR contrast agents.

    abstract::A new high-throughput MRI method for screening chemical exchange saturation transfer (CEST) agents is demonstrated, allowing simultaneous testing of multiple samples with minimal attention to sample configuration and shimming of the main magnetic field (B(0)). This approach, which is applicable to diamagnetic, paramag...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.383

    authors: Liu G,Gilad AA,Bulte JW,van Zijl PC,McMahon MT

    更新日期:2010-05-01 00:00:00

  • Use of 18F-FDG-PET/CT for Retroperitoneal/Intra-Abdominal Soft Tissue Sarcomas.

    abstract:Rationale:To assess the diagnostic value of 18F-FDG-PET/CT for different retroperitoneal soft tissue sarcomas (STS) and other similar tumors. To analyze the predictive value of 18F-FDG-PET/CT for histological grade and main prognostic factors. Methods:195 patients with 44 different diseases have been included. Relatio...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/2601281

    authors: Liu DN,Li ZW,Wang HY,Zhao M,Zhao W,Hao CY

    更新日期:2018-07-02 00:00:00

  • Antibody-functionalized nanoparticles for imaging cancer: influence of conjugation to gold nanoparticles on the biodistribution of 89Zr-labeled cetuximab in mice.

    abstract::Antibody-labeled gold nanoparticles represent a promising novel tool regarding cancer imaging and therapy. Nevertheless, the characterization of biodistribution of such immunonanocarriers has been poorly documented. In this study, the biodistribution of (89)Zr-labeled cetuximab before and after the coupling reaction t...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1539

    authors: Karmani L,Labar D,Valembois V,Bouchat V,Nagaswaran PG,Bol A,Gillart J,Levêque P,Bouzin C,Bonifazi D,Michiels C,Feron O,Grégoire V,Lucas S,Vander Borght T,Gallez B

    更新日期:2013-09-01 00:00:00

  • Quantitative (1)H MRI, (19)F MRI, and (19)F MRS of cell-internalized perfluorocarbon paramagnetic nanoparticles.

    abstract::In vivo molecular imaging with targeted MRI contrast agents will require sensitive methods to quantify local concentrations of contrast agent, enabling not only imaging-based recognition of pathological biomarkers but also detection of changes in expression levels as a consequence of disease development, therapeutic i...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.398

    authors: Kok MB,de Vries A,Abdurrachim D,Prompers JJ,Grüll H,Nicolay K,Strijkers GJ

    更新日期:2011-01-01 00:00:00

  • Spectroscopic, radiochemical, and theoretical studies of the Ga3+-N-2-hydroxyethyl piperazine-N'-2-ethanesulfonic acid (HEPES buffer) system: evidence for the formation of Ga3+ - HEPES complexes in (68) Ga labeling reactions.

    abstract::Recent reports have claimed a superior performance of HEPES buffer in comparison to alternative buffer systems for (67/68) Ga labeling in aqueous media. In this paper we report spectroscopic ((1) H and (71) Ga NMR), radiochemical, mass spectrometry and theoretical modeling studies on the Ga(3+)/HEPES system (HEPES = N...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1517

    authors: Martins AF,Prata MI,Rodrigues SP,Geraldes CF,Riss PJ,Amor-Coarasa A,Burchardt C,Kroll C,Roesch F

    更新日期:2013-05-01 00:00:00

  • Minimization of self-quenching fluorescence on dyes conjugated to biomolecules with multiple labeling sites via asymmetrically charged NIR fluorophores.

    abstract::Self-aggregation of dyes even at low concentrations poses a considerable challenge in preparing sufficiently bright molecular probes for in vivo imaging, particularly in the conjugation of near infrared cyanine dyes to polypeptides with multiple labeling sites. Such self-aggregation leads to a significant energy trans...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1585

    authors: Zhegalova NG,He S,Zhou H,Kim DM,Berezin MY

    更新日期:2014-09-01 00:00:00

  • USPIO-loaded red blood cells as a biomimetic MR contrast agent: a relaxometric study.

    abstract::Red blood cells (RBCs) loaded with iron oxide nanoparticles have been proposed as biomimetic constructs with long half-life (ca. 20 days) in the blood compartment and potentially interesting properties (such as relaxivity) as intravascular contrast agents for magnetic resonance imaging. However, the encapsulation of n...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1562

    authors: Boni A,Ceratti D,Antonelli A,Sfara C,Magnani M,Manuali E,Salamida S,Gozzi A,Bifone A

    更新日期:2014-05-01 00:00:00

  • Analytical Interference by Contrast Agents in Biochemical Assays.

    abstract:Objective:To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods:The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29 most frequently perform...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/1323802

    authors: Otnes S,Fogh-Andersen N,Rømsing J,Thomsen HS

    更新日期:2017-04-10 00:00:00

  • Parameters Influencing PET Imaging Features: A Phantom Study with Irregular and Heterogeneous Synthetic Lesions.

    abstract:Aim:To evaluate reproducibility and stability of radiomic features as effects of the use of different volume segmentation methods and reconstruction settings. The potential of radiomics in really capturing the presence of heterogeneous tumor uptake and irregular shape was also investigated. Materials and Methods:An an...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/5324517

    authors: Gallivanone F,Interlenghi M,D'Ambrosio D,Trifirò G,Castiglioni I

    更新日期:2018-09-10 00:00:00

  • Real-time 3D MRI of contrast agents in whole living mice.

    abstract::A specific mouse whole body coil and a dedicated gradient system at 4.7 T were coupled with an ultra-fast 3D gradient echo MRI and keyhole reconstruction technique to obtain 3D whole-body dynamic T(1)-weighted or T(2)*-weighted imaging. The technique was used to visualize the real-time distribution of non-targeting T(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.429

    authors: Bled E,Hassen WB,Pourtau L,Mellet P,Lanz T,Schüler D,Voisin P,Franconi JM,Thiaudière E,Miraux S

    更新日期:2011-07-01 00:00:00

  • VCAM-1-targeting gold nanoshell probe for photoacoustic imaging of atherosclerotic plaque in mice.

    abstract::The development of molecular probes and novel imaging modalities, allowing better resolution and specificity, is associated with an increased potential for molecular imaging of atherosclerotic plaques especially in basic and pre-clinical research applications. In that context, a photoacoustic molecular probe based on ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1491

    authors: Rouleau L,Berti R,Ng VW,Matteau-Pelletier C,Lam T,Saboural P,Kakkar AK,Lesage F,Rhéaume E,Tardif JC

    更新日期:2013-01-01 00:00:00

  • Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging.

    abstract:Objective:The purpose of this study was to demonstrate the feasibility of using hyperpolarized carbon-13 (13C) metabolic imaging with [1-13C]-labeled pyruvate for evaluating real-time in vivo metabolism of orthotopic diffuse intrinsic pontine glioma (DIPG) xenografts. Materials and Methods:3D 13C magnetic resonance sp...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/3215658

    authors: Autry AW,Hashizume R,James CD,Larson PEZ,Vigneron DB,Park I

    更新日期:2018-07-30 00:00:00

  • Phenylboronate 160Tb complexes for molecular recognition of glycoproteins expressed on tumor cells.

    abstract::The over-expression of sialic acid on the surface of cancer cells compared with normal ones makes this nine-carbon sugar an attractive biomarker for molecular diagnosis and therapy. Here, we describe a study on the molecular recognition of sialic acid end groups on the surface of human glioma cells by (160)Tb-DTPA-EN(...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.123

    authors: Djanashvili K,Koning GA,van der Meer AJ,Wolterbeek HT,Peters JA

    更新日期:2007-01-01 00:00:00

  • Ferumoxides-protamine sulfate is more effective than ferucarbotran for cell labeling: implications for clinically applicable cell tracking using MRI.

    abstract::The use of superparamagnetic iron oxide (SPIO) for labeling cells holds great promise for clinically applicable cell tracking using magnetic resonance imaging. For clinical application, an effectively and specifically labeled cell preparation is highly desired (i.e. a large amount of intracellular iron and a negligibl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.289

    authors: van Buul GM,Farrell E,Kops N,van Tiel ST,Bos PK,Weinans H,Krestin GP,van Osch GJ,Bernsen MR

    更新日期:2009-09-01 00:00:00