Superparamagnetic iron oxide nanoparticles conjugated to a grass pollen allergen and an optical probe.

Abstract:

:In this study we report the development of a bioconjugate between superparamagnetic iron oxide nanoparticles and Phl p5a (one of the major allergens from grass pollen). The bioconjugate also contains an optical probe (Alexa647) conjugated to the nanoparticle via biotin-streptavidin association. We show that this conjugate has a range of features that makes it a very promising candidate to image the localization of this allergen in vivo: (a) upon conjugation to the iron oxide nanoparticles, the allergen retains its ability to interact with IgE antibodies; (b) the magnetic properties of the iron oxide core of this bioconjugate are suitable for MR imaging; and (c) Alexa647 fluorophore retains its emission properties once attached to the iron oxide nanoparticles, yielding a dual modality MRI-optical probe.

authors

Herranz F,Schmidt-Weber CB,Shamji MH,Narkus A,Ruiz-Cabello J,Vilar R

doi

10.1002/cmmi.1466

subject

Has Abstract

pub_date

2012-07-01 00:00:00

pages

435-9

issue

4

eissn

1555-4309

issn

1555-4317

journal_volume

7

pub_type

杂志文章
  • Corrigendum to "Erbium-Based Perfusion Contrast Agent for Small-Animal Microvessel Imaging".

    abstract::[This corrects the article DOI: 10.1155/2017/7368384.]. ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1155/2018/2165693

    authors: Tse JJ,Dunmore-Buyze PJ,Drangova M,Holdsworth DW

    更新日期:2018-08-23 00:00:00

  • Uniform mesoporous silica coated iron oxide nanoparticles as a highly efficient, nontoxic MRI T(2) contrast agent with tunable proton relaxivities.

    abstract::Monodisperse mesoporous silica (mSiO(2) ) coated superparamagnetic iron oxide (Fe(3) O(4) @mSiO(2) ) nanoparticles (NPs) have been developed as a potential magnetic resonance imaging (MRI) T(2) contrast agent. To evaluate the effect of surface coating on MRI contrast efficiency, we examined the proton relaxivities of ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1473

    authors: Ye F,Laurent S,Fornara A,Astolfi L,Qin J,Roch A,Martini A,Toprak MS,Muller RN,Muhammed M

    更新日期:2012-09-01 00:00:00

  • Can we accurately quantify nanoparticle associated proteins when constructing high-affinity MRI molecular imaging probes?

    abstract::Targeted magnetic resonance contrast agents (e.g. iron oxide nanoparticles) have the potential to become highly selective imaging tools. In this context, quantification of the coupled amount of protein is essential for the design of antibody- or antibody fragment-conjugated nanoparticles. Nevertheless, the presence of...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.405

    authors: Rimkus G,Bremer-Streck S,Grüttner C,Kaiser WA,Hilger I

    更新日期:2011-05-01 00:00:00

  • Development and validation of a smoothing-splines-based correction method for improving the analysis of CEST-MR images.

    abstract::Chemical exchange saturation transfer (CEST) imaging is an emerging MRI technique relying on the use of endogenous or exogenous molecules containing exchangeable proton pools. The heterogeneity of the water resonance frequency offset plays a key role in the occurrence of artifacts in CEST-MR images. To limit this draw...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.240

    authors: Stancanello J,Terreno E,Castelli DD,Cabella C,Uggeri F,Aime S

    更新日期:2008-07-01 00:00:00

  • Preclinical Imaging Biomarkers for Postischaemic Neurovascular Remodelling.

    abstract::In the pursuit of understanding the pathological alterations that underlie ischaemic injuries, such as vascular remodelling and reorganisation, there is a need for recognising the capabilities and limitations of in vivo imaging techniques. Thus, this review presents contemporary published research of imaging modalitie...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1155/2019/3128529

    authors: Gandhi R,Tsoumpas C

    更新日期:2019-02-03 00:00:00

  • Considerations for the clinical use of contrast agents for cellular MRI in regenerative medicine.

    abstract::Advances in regenerative medicine are rapidly transforming healthcare. A cornerstone of regenerative medicine is the introduction of cells that were grown or manipulated in vitro. Key questions that arise after these cells are re-introduced are: whether these cells are localized in the appropriate site; whether cells ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章,评审

    doi:10.1002/cmmi.1547

    authors: Modo M,Kolosnjaj-Tabi J,Nicholls F,Ling W,Wilhelm C,Debarge O,Gazeau F,Clement O

    更新日期:2013-11-01 00:00:00

  • Functionalization of Gadolinium Chelates Silica Nanoparticle through Silane Chemistry for Simultaneous MRI/64Cu PET Imaging.

    abstract::Multimodal nanoprobes are highly demanded for biomedical imaging applications to enhance the reliability of the diagnostic results. Among different types of nano-objects, ultrasmall silica gadolinium nanoparticle (SiGdNP) appears as a safe, effective, and versatile platform for this purpose. In this study, a new metho...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/7938267

    authors: Tran VL,Thakare V,Natuzzi M,Moreau M,Oudot A,Vrigneaud JM,Courteau A,Louis C,Roux S,Boschetti F,Denat F,Tillement O,Lux F

    更新日期:2018-11-01 00:00:00

  • Classification of acute and delayed contrast media-induced reactions: proposal of a three-step system.

    abstract::Physicians and scientists use a broad spectrum of terms to classify contrast media (CM)-induced adverse reactions. In particular, the designation of hypersensitivity reactions is quite varied. Consequently, comparisons of different papers dealing with this subject are difficult or even impossible. Moreover, general de...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1475

    authors: Böhm I,Heverhagen JT,Klose KJ

    更新日期:2012-11-01 00:00:00

  • The influence of ferucarbotran on the chondrogenesis of human mesenchymal stem cells.

    abstract::For in vivo applications of magnetically labeled stem cells, biological effects of the labeling procedure have to be precluded. This study evaluates the effect of different ferucarbotran cell labeling protocols on chondrogenic differentiation of human mesenchymal stem cells (hMSC) as well as their implications for MR ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.276

    authors: Henning TD,Sutton EJ,Kim A,Golovko D,Horvai A,Ackerman L,Sennino B,McDonald D,Lotz J,Daldrup-Link HE

    更新日期:2009-07-01 00:00:00

  • Influence of paramagnetic melanin on the MRI contrast in melanoma: a combined high-field (11.7 T) MRI and EPR study.

    abstract::Melanoma is the most dangerous form of skin cancer and its incidence is rising each year. Because the current methods of diagnosis based on the visual aspect of the tumor show limitations, several new techniques are emerging to help in this diagnosis, amongst which are magnetic resonance imaging (MRI) and electron par...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1554

    authors: Godechal Q,Mignion L,Karroum O,Magat J,Danhier P,Morandini R,Ghanem GE,Leveque P,Gallez B

    更新日期:2014-03-01 00:00:00

  • Novel Gd(III)-based probes for MR molecular imaging of matrix metalloproteinases.

    abstract::Two novel Gd-based contrast agents (CAs) for the molecular imaging of matrix metalloproteinases (MMPs) were synthetized and characterized in vitro and in vivo. These probes were based on the PLG*LWAR peptide sequence, known to be hydrolyzed between Gly and Leu by a broad panel of MMPs. A Gd-DOTA chelate was conjugated...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.478

    authors: Gringeri CV,Menchise V,Rizzitelli S,Cittadino E,Catanzaro V,Dati G,Chaabane L,Digilio G,Aime S

    更新日期:2012-03-01 00:00:00

  • USPIO-loaded red blood cells as a biomimetic MR contrast agent: a relaxometric study.

    abstract::Red blood cells (RBCs) loaded with iron oxide nanoparticles have been proposed as biomimetic constructs with long half-life (ca. 20 days) in the blood compartment and potentially interesting properties (such as relaxivity) as intravascular contrast agents for magnetic resonance imaging. However, the encapsulation of n...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1562

    authors: Boni A,Ceratti D,Antonelli A,Sfara C,Magnani M,Manuali E,Salamida S,Gozzi A,Bifone A

    更新日期:2014-05-01 00:00:00

  • Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging.

    abstract:Objective:The purpose of this study was to demonstrate the feasibility of using hyperpolarized carbon-13 (13C) metabolic imaging with [1-13C]-labeled pyruvate for evaluating real-time in vivo metabolism of orthotopic diffuse intrinsic pontine glioma (DIPG) xenografts. Materials and Methods:3D 13C magnetic resonance sp...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/3215658

    authors: Autry AW,Hashizume R,James CD,Larson PEZ,Vigneron DB,Park I

    更新日期:2018-07-30 00:00:00

  • Analytical Interference by Contrast Agents in Biochemical Assays.

    abstract:Objective:To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods:The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29 most frequently perform...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/1323802

    authors: Otnes S,Fogh-Andersen N,Rømsing J,Thomsen HS

    更新日期:2017-04-10 00:00:00

  • Characterization of MRI contrast agent-loaded polymeric nanocapsules as versatile vehicle for targeted imaging.

    abstract::Various contrast agents (Magnevist, Gadovist and Multihance) loaded into polymeric nanocapsules were synthesized by the inverse miniemulsion technique. The relaxivity of the resultant contrast agents was assessed at 1.5 T magnetic field strength. The ionic relaxivity of the contrast agents could at least be maintained...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.364

    authors: Sharma S,Paiphansiri U,Hombach V,Mailänder V,Zimmermann O,Landfester K,Rasche V

    更新日期:2010-03-01 00:00:00

  • Preparation of 68Ga-PSMA-11 with a Synthesis Module for Micro PET-CT Imaging of PSMA Expression during Prostate Cancer Progression.

    abstract:Objective:To synthesize 68Ga-Glu-urea-Lys(Ahx)-HBED-CC (68Ga-PSMA-11) with a synthesis module and investigate PET-CT imaging to monitor PSMA expression during prostate cancer (PCa) progression and tumor growth in mice bearing subcutaneous PCa xenografts. Method:The radiochemical purity and stability of  68Ga-PSMA-11 w...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2018/8046541

    authors: Wang Y,Shao G,Wu J,Cui C,Zang S,Qiu F,Jia R,Wang Z,Wang F

    更新日期:2018-04-26 00:00:00

  • Dynamic contrast-enhanced computed tomography for the quantification of tumor response to vasoactive agents in a rat tumor model: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this pilot study was to establish the ability of dynamic contrast enhanced computed tomography (DCE-CT) to detect changes in tumor blood flow (BF) and oxygenation induced by vasoactive substances in rats. MATERIALS AND METHODS:Under ultrasound guidance, a fiber-optic probe was g...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.399

    authors: Pollard RE,Larson RF

    更新日期:2011-01-01 00:00:00

  • Thermodynamic stability and kinetic inertness of a Gd-DTPA bisamide complex grafted onto gold nanoparticles.

    abstract::Gold nanoparticles coated by gadolinium (III) chelates (Au@DTDTPA) where DTDTPA is a dithiolated bisamide derivative of diethylenetriamine-N,N,N',N'',N''-pentaacetic acid (DTPA), constituted contrast agents for both X-ray computed tomography and magnetic resonance imaging. In an MRI context, highly stable Gd(3+) compl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1616

    authors: Mogilireddy V,Déchamps-Olivier I,Alric C,Laurent G,Laurent S,Vander Elst L,Muller R,Bazzi R,Roux S,Tillement O,Chuburu F

    更新日期:2015-05-01 00:00:00

  • How to perform accurate and reliable measurements of longitudinal and transverse relaxation times of MRI contrast media in aqueous solutions.

    abstract::Knowledge of the longitudinal and transverse relaxation times (T(1) and T(2)) of water protons in an aqueous solution of an MRI contrast agent is essential for its characterization. These parameters can be measured at low field on low resolution spectrometers or at high field on high resolution spectrometers. The reli...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.294

    authors: Henoumont C,Laurent S,Vander Elst L

    更新日期:2009-11-01 00:00:00

  • Synthesis and Evaluation of 18F-Labeled Peptide for Gonadotropin-Releasing Hormone Receptor Imaging.

    abstract::The gonadotropin-releasing hormone (GnRH) receptor is overexpressed in the majority of tumors of the human reproductive system. The purpose of this study was to develop an 18F-labeled peptide for tumor GnRH receptor imaging. In this study, the GnRH (pGlu1-His2-Trp3-Ser4-Tyr5-Gly6-Leu7-Arg8-Pro9-Gly10-NH2) peptide anal...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/5635269

    authors: Huang S,Li H,Han Y,Fu L,Ren Y,Zhang Y,Li Y,Sun P,Wang M,Wu H,Wang Q,Hu K

    更新日期:2019-03-07 00:00:00

  • Early Prediction of Treatment Response of Neuroendocrine Hepatic Metastases after Peptide Receptor Radionuclide Therapy with 90Y-DOTATOC Using Diffusion Weighted and Dynamic Contrast-Enhanced MRI.

    abstract::The purpose of this study was to determine if parameters derived from diffusion-weighted (DW-) and dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) can help to assess early response to peptide receptor radionuclide therapy (PRRT) with 90Y-DOTATOC in neuroendocrine hepatic metastases (NET-HM). Twenty p...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2019/1517208

    authors: Weikert T,Maas OC,Haas T,Klarhöfer M,Bremerich J,Forrer F,Sauter AW,Sommer G

    更新日期:2019-11-11 00:00:00

  • A First Report on [18F]FPRGD2 PET/CT Imaging in Multiple Myeloma.

    abstract::An observational study was set up to assess the feasibility of [18F]FPRGD2 PET/CT for imaging patients with multiple myeloma (MM) and to compare its detection rate with low dose CT alone and combined [18F]NaF/[18F]FDG PET/CT images. Four patients (2 newly diagnosed patients and 2 with relapsed MM) were included and un...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/6162845

    authors: Withofs N,Cousin F,De Prijck B,Bonnet C,Hustinx R,Gambhir SS,Beguin Y,Caers J

    更新日期:2017-07-27 00:00:00

  • E-selectin targeting to visualize tumors in vivo.

    abstract::Generally angiogenic factors induce the expression of E-selectin in vascular endothelial cells in the tumors. In this study, we employed an anti-E-selectin monoclonal antibody to target tumors in vivo and evaluated an optical imaging reagent to visualize tumor regions. The anti-E-selectin antibody was conjugated on th...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.367

    authors: Hirai M,Hiramatsu Y,Iwashita S,Otani T,Chen L,Li YG,Okada M,Oie K,Igarashi K,Wakita H,Seno M

    更新日期:2010-03-01 00:00:00

  • Disruptive chemical doping in a ferritin-based iron oxide nanoparticle to decrease r2 and enhance detection with T1-weighted MRI.

    abstract::Inorganic doping was used to create flexible, paramagnetic nanoparticle contrast agents for in vivo molecular magnetic resonance imaging (MRI) with low transverse relaxivity (r2). Most nanoparticle contrast agents formed from superparamagnetic metal oxides are developed with high r2. While sensitive, they can have lim...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1578

    authors: Clavijo Jordan MV,Beeman SC,Baldelomar EJ,Bennett KM

    更新日期:2014-09-01 00:00:00

  • Spectroscopic, radiochemical, and theoretical studies of the Ga3+-N-2-hydroxyethyl piperazine-N'-2-ethanesulfonic acid (HEPES buffer) system: evidence for the formation of Ga3+ - HEPES complexes in (68) Ga labeling reactions.

    abstract::Recent reports have claimed a superior performance of HEPES buffer in comparison to alternative buffer systems for (67/68) Ga labeling in aqueous media. In this paper we report spectroscopic ((1) H and (71) Ga NMR), radiochemical, mass spectrometry and theoretical modeling studies on the Ga(3+)/HEPES system (HEPES = N...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1517

    authors: Martins AF,Prata MI,Rodrigues SP,Geraldes CF,Riss PJ,Amor-Coarasa A,Burchardt C,Kroll C,Roesch F

    更新日期:2013-05-01 00:00:00

  • Ferumoxides-protamine sulfate is more effective than ferucarbotran for cell labeling: implications for clinically applicable cell tracking using MRI.

    abstract::The use of superparamagnetic iron oxide (SPIO) for labeling cells holds great promise for clinically applicable cell tracking using magnetic resonance imaging. For clinical application, an effectively and specifically labeled cell preparation is highly desired (i.e. a large amount of intracellular iron and a negligibl...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.289

    authors: van Buul GM,Farrell E,Kops N,van Tiel ST,Bos PK,Weinans H,Krestin GP,van Osch GJ,Bernsen MR

    更新日期:2009-09-01 00:00:00

  • Electron paramagnetic resonance as a sensitive tool to assess the iron oxide content in cells for MRI cell labeling studies.

    abstract::MRI cell tracking is a promising technique to track various cell types (stem cells, tumor cells, etc.) in living animals. Usually, cells are incubated with iron oxides (T(2) contrast agent) in order to take up the particles before being injected in vivo. Iron oxide quantification is important in such studies for valid...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.497

    authors: Danhier P,De Preter G,Boutry S,Mahieu I,Leveque P,Magat J,Haufroid V,Sonveaux P,Bouzin C,Feron O,Muller RN,Jordan BF,Gallez B

    更新日期:2012-05-01 00:00:00

  • Optimizing quantitative in vivo fluorescence imaging with near-infrared quantum dots.

    abstract::Quantum dots (QDs) are fluorescent nanoparticles with broad excitation and narrow, wavelength-tunable emission spectra. They are used extensively for in vitro fluorescence imaging studies and more recently for in vivo small animal and pre-clinical studies. To date there has been little concern about the selection of Q...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.409

    authors: Rosenblum LT,Kosaka N,Mitsunaga M,Choyke PL,Kobayashi H

    更新日期:2011-05-01 00:00:00

  • Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    abstract::Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitativ...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1002/cmmi.1569

    authors: Sun PZ,Wang Y,Dai Z,Xiao G,Wu R

    更新日期:2014-07-01 00:00:00

  • Comparison of 68Ga-DOTA-Siglec-9 and 18F-Fluorodeoxyribose-Siglec-9: Inflammation Imaging and Radiation Dosimetry.

    abstract::Sialic acid-binding immunoglobulin-like lectin 9 (Siglec-9) is a ligand of inflammation-inducible vascular adhesion protein-1 (VAP-1). We compared 68Ga-DOTA- and 18F-fluorodeoxyribose- (FDR-) labeled Siglec-9 motif peptides for PET imaging of inflammation. Methods. Firstly, we examined 68Ga-DOTA-Siglec-9 and 18F-FDR-S...

    journal_title:Contrast media & molecular imaging

    pub_type: 杂志文章

    doi:10.1155/2017/7645070

    authors: Virtanen H,Silvola JMU,Autio A,Li XG,Liljenbäck H,Hellberg S,Siitonen R,Ståhle M,Käkelä M,Airaksinen AJ,Helariutta K,Tolvanen T,Veres TZ,Saraste A,Knuuti J,Jalkanen S,Roivainen A

    更新日期:2017-12-31 00:00:00