Abstract:
:In the present longitudinal study, we followed volatile organic compounds (VOCs) excreted in exhaled breath of 20 healthy individuals over time, while adhering to a gluten-free diet for 4 weeks prior to adherence to a normal diet. We used gas chromatography coupled with mass spectrometry (TD-GC-tof-MS) in combination with chemometric analysis to detect an array of VOCs in exhaled breath. Multivariate analysis was applied to extract the maximal information from the obtained data. Dietary intake was assessed to verify adherence to the diet and to get insight into macronutrient intake during the intervention period. A set of 12 volatile compounds distinguished the samples obtained during the gluten-free diet from those obtained during a normal diet. Seven compounds could be chemically identified (2-butanol, octane, 2-propyl-1pentanol, nonanal, dihydro-4-methyl-2(3H)-furanone, nonanoic acid and dodecanal) and speculated on a possible origin. Our findings suggest that a gluten-free dietary period had a reversible impact on participants' excreted metabolites visible in their breath. Several explanations are proposed of influencing metabolic status through dietary interventions. Although the exact origin of the discriminating compounds is not yet known, the main goal of this paper was to share a new potential use of exhaled air analysis and might become a useful tool in fields of nutrition and metabolism.
journal_name
J Breath Resjournal_title
Journal of breath researchauthors
Baranska A,Tigchelaar E,Smolinska A,Dallinga JW,Moonen EJ,Dekens JA,Wijmenga C,Zhernakova A,van Schooten FJdoi
10.1088/1752-7155/7/3/037104subject
Has Abstractpub_date
2013-09-01 00:00:00pages
037104issue
3eissn
1752-7155issn
1752-7163journal_volume
7pub_type
杂志文章abstract::To investigate the premise that levels of endogenous volatile organic compounds (VOC) in breath reflect those in blood, the concentration of acetone and isoprene were measured in radial arterial blood, peripheral venous blood and breath samples from ten healthy volunteers. Coefficients of repeatability as a percentage...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/3/2/027005
更新日期:2009-06-01 00:00:00
abstract::Chronic obstructive pulmonary disease (COPD)/emphysema risk groups are well defined and screening allows for early identification of disease. The capability of exhaled volatile organic compounds (VOCs) to detect emphysema, as found by computed tomography (CT) in current and former heavy smokers participating in a lung...
journal_title:Journal of breath research
pub_type: 临床试验,杂志文章,多中心研究
doi:10.1088/1752-7155/5/4/046009
更新日期:2011-12-01 00:00:00
abstract::Reactive oxygen species are associated with tissue inflammation and injury. Our laboratory has demonstrated that ethane, a stable product of lipid peroxidation, in exhaled breath can be used to measure total body oxidative stress. Herein patients were studied who underwent outpatient surgery, laproscopic bilateral tub...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/3/1/016002
更新日期:2009-03-01 00:00:00
abstract::Exhaled breath condensate (EBC) is increasingly being used as a non-invasive method for disease diagnosis and environmental exposure assessment. We previously detected the nucleic acids of bacterial pathogens in EBC. Influenza viruses can be transmitted through aerosols during coughing and exhaling. Existing detection...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/abd14c
更新日期:2021-01-12 00:00:00
abstract::The human genome is the counterpart to the human exposome with respect to the gene × environment interaction that describes health state and outcome. The genome has already been sequenced and is in the process of being assessed for specific functionality; to similarly decode the exposome will require the measurement a...
journal_title:Journal of breath research
pub_type: 杂志文章,评审
doi:10.1088/1752-7155/5/4/046005
更新日期:2011-12-01 00:00:00
abstract::Wheeze is a common symptom in preschool children. The role of bacteria, regulatory T (T(reg)) cells and their association with airway inflammation in preschool wheeze is largely unknown. We evaluated inflammatory markers in exhaled breath condensate (EBC), bacterial colonization and circulating T(reg) cells in prescho...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/6/4/046001
更新日期:2012-12-01 00:00:00
abstract::The analysis of exhaled breath is drawing a high degree of interest in the diagnostics of various diseases, including lung cancer. Electronic nose (E-nose) technology is one of the perspective approaches in the field due to its relative simplicity and cost efficiency. The use of an E-nose together with pattern recogni...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/ab433d
更新日期:2019-10-23 00:00:00
abstract::Exhaled NO (FE(NO)) measurements have been utilized as a marker to diagnose asthma as well as a non-invasive tool for monitoring airway inflammation and the response to anti-inflammatory medications. One area where this non-invasive monitoring may be helpful is for asthmatic athletes as they train for competitive even...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/2/3/037027
更新日期:2008-09-01 00:00:00
abstract::In this article, a database of blood:air and fat:air partition coefficients (λ b:a and λ f:a) is reported for estimating 1678 volatile organic compounds recently reported to appear in the volatilome of the healthy human. For this purpose, a quantitative structure-property relationship (QSPR) approach was applied and a...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/1/017103
更新日期:2016-01-27 00:00:00
abstract::Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) represents an attractive tool for the real-time analysis of VOC profiles in human breath. Quantification of breath VOCs by means of direct MS may be affected by the matrix, as human breath not only contains several hundred VOCs at the ppbV-pptV lev...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa9eea
更新日期:2018-03-01 00:00:00
abstract::Oral malodour is a common condition which affects a large proportion of the population, resulting in social, emotional and psychological stress. Certain oral bacteria form a coating called a biofilm on the tongue dorsum and degrade organic compounds releasing volatile sulfur compounds that are malodourous. Current che...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/10/4/046009
更新日期:2016-10-18 00:00:00
abstract::Breath analysis represents a new frontier in medical diagnosis and a powerful tool for cancer biomarker discovery due to the recent development of analytical platforms for the detection and identification of human exhaled volatile compounds. Statistical and bioinformatic tools may represent an effective complement to ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/9/3/031001
更新日期:2015-09-21 00:00:00
abstract::Breath contains hundreds of volatile organic compounds (VOCs), the composition of which is altered in a wide variety of diseases. Bacteria are implicated in the formation of VOCs, but the biochemical mechanisms that lead to the formation of breath VOCs remain largely hypothetical. We hypothesized that bacterial DNA fr...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/10/4/047103
更新日期:2016-12-17 00:00:00
abstract::The results of experiments are described in which a known quantity of sterile deuterated water is injected directly into the pulmonary circulation via the right internal jugular vein of several haemodialysis patients and the deuterium to hydrogen ratio, D/H, in the exhaled lung water was measured using the flowing aft...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/6/3/036005
更新日期:2012-09-01 00:00:00
abstract::In this work, we present a hydrophilic self-cleaning condenser surface for the collection of biological and environmental aerosol samples. The condenser is installed in a battery-operated hand-held breath sampling device. The device performance is characterized by the collection and analysis of exhaled breath samples ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aac5a5
更新日期:2018-06-08 00:00:00
abstract::Exhaled air contains sub-micron droplets of lung liquid, which potentially bear biomarkers of lung diseases. After dehydration they form dry residue particles (DRPs). As a first step in developing techniques to characterize individual DRPs, a new electrostatic collector was designed in which DRPs are charged within a ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa5359
更新日期:2017-01-09 00:00:00
abstract::Robust methods for breath sampling and analysis are required for potential clinical applications. We have evaluated an improved sampling and experimental design, assessing instrumental and biological variability within and across breath measurements. Calibration curves for selected relevant volatile organic compounds...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/6/2/026002
更新日期:2012-06-01 00:00:00
abstract::Analysis of breath acetone could be useful in the Intensive Care Unit (ICU) setting to monitor evidence of starvation and metabolic stress. The aims of this study were to examine the relationship between acetone concentrations in breath and blood in critical illness, to explore any changes in breath acetone concentrat...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/7/3/037102
更新日期:2013-09-01 00:00:00
abstract::Breath tests have been used to investigate many physiological functions. Recently, we have developed a breath test system by using a non-invasive technique in conscious rats. In this study, we investigated the effect of atropine sulfate on the gastric emptying and gastrocecal transit time using [1-(13)C]acetic acid an...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/3/4/047003
更新日期:2009-12-01 00:00:00
abstract::Despite recent progress in Critical Care Medicine, sepsis is still a major medical problem with a high rate of mortality and morbidity especially in intensive care units. Oxidative stress induced by inflammation associated with sepsis causes degradation of heme protein, increases microsomal free heme content, promotes...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/4/4/047103
更新日期:2010-12-01 00:00:00
abstract::Methods for breath sampling and analysis require robust quality assessment to minimise the risk of false discoveries. Planning large-scale multi-site breath metabolite profiling studies also requires careful consideration of systematic and random variation as a result of sampling and analysis techniques. In this study...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aae557
更新日期:2018-10-30 00:00:00
abstract::Based on the adsorption of analytes in the sampling loop, a time-resolved dynamic dilution introduction method was developed for negative ion mobility spectrometry to continuously monitor end-tidal propofol without other sample pre-separation. The dynamic dilution characteristics of propofol and moisture in the Teflon...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/9/1/016002
更新日期:2015-01-05 00:00:00
abstract::The measurement of the peak exhaled breath temperature (EBT) during multiple tidal breaths offers an easy, non-invasive tool for monitoring airway inflammation. Chronic obstructive pulmonary disease (COPD) is linked to airway inflammation, which is further aggravated by exacerbations of the disease. However, the peak ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/8/4/046002
更新日期:2014-09-18 00:00:00
abstract::There have been a number of studies in which metal oxide sensors (MOS) have replaced conventional analytical detectors in gas chromatography systems. However, despite the use of these instruments in a range of applications including breath research the sensor responses (i.e. resistance changes w.r.t. concentration of ...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/aa8efe
更新日期:2017-12-06 00:00:00
abstract::Arterial lactate concentrations, taken as indicators of physical fitness, in athletes as well as in patients with cardio-respiratory or metabolic diseases, are measured invasively from arterialized ear lobe blood. Currently developed micro enzyme detectors permit a non-invasive measurement of hypoxia-related metabolit...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/4/1/017105
更新日期:2010-03-01 00:00:00
abstract::Exhaled breath collection is used to identify and monitor inflammatory or oxidative components in breath. Exhaled breath sample collection is noninvasive and would greatly benefit human pollutant exposure research. We demonstrate the efficacy of exhaled breath collection and analysis in two human exposure studies to o...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/2/3/037019
更新日期:2008-09-01 00:00:00
abstract::Fractional exhaled nitric oxide (FENO) is a marker of airway inflammation. Measuring FENO at multiple flow rates enables calculation of NO parameters: bronchial NO output (J awNO), bronchial wall (C awNO) and alveolar (C ANO) NO concentrations, and bronchial diffusion factor of NO (D awNO). FENO is known to rapidly re...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7163/abc054
更新日期:2020-11-05 00:00:00
abstract::Poor compliance to prescribed medication regimens in clinical trials continues to be a major obstacle to drug development success and cost reduction, and there is no gold standard technology that is cheap and effective to reliably measure drug compliance. This paper presents a new drug compliance scheme based on the d...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/1/2/026006
更新日期:2007-12-01 00:00:00
abstract::Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath...
journal_title:Journal of breath research
pub_type: 杂志文章
doi:10.1088/1752-7155/8/2/026003
更新日期:2014-06-01 00:00:00
abstract::Fractional exhaled NO (FeNO) is universally considered an indirect marker of eosinophilic airways inflammation, playing an important role in the physiopathology of childhood asthma. Advances in technology and standardization have allowed a wider use of FeNO in clinical practice in children from the age of four years. ...
journal_title:Journal of breath research
pub_type: 杂志文章,评审
doi:10.1088/1752-7155/6/2/027103
更新日期:2012-06-01 00:00:00