Exhaled breath temperature in patients with stable and exacerbated COPD.

Abstract:

:The measurement of the peak exhaled breath temperature (EBT) during multiple tidal breaths offers an easy, non-invasive tool for monitoring airway inflammation. Chronic obstructive pulmonary disease (COPD) is linked to airway inflammation, which is further aggravated by exacerbations of the disease. However, the peak EBT has not been studied in patients with COPD. The breath temperature was measured (X-halo, Delmedica Investments) in 19 control non-smoking subjects (age: 28  ±  11 years, mean ± standard deviation), 19 control smoking/ex-smoking subjects (53  ±  9 years), 20 patients with stable COPD (66  ±  8 years), and 17 patients with COPD at onset and also after recovery from an acute exacerbation (AECOPD; 65  ±  10 years). Spontaneous sputa were collected in AECOPD. The intra-class correlation coefficient of the repeated EBT measurements in non-smokers was 0.87 (95% confidence interval: 0.70-0.95). The peak EBT was different between the subject groups (Kruskal-Wallis test, p = 0.02), with lower values in the patients with stable COPD (34.00/33.35-34.34/°C; median /interquartile range/) than in the smoking/ex-smoking control subjects (34.51/34.20-34.68/°C, p < 0.05). The EBT was higher at the onset of AECOPD (34.58/34.12-34.99/°C, p < 0.05) compared to in a stable condition, and positively correlated with the sputum leukocyte count (p = 0.049, r2 = 0.30; Spearman test) and neutrophil percentage (p = 0.03, r(2) = 0.36). The breath temperature decreased after recovery from AECOPD (34.10/33.72-34.43/°C, p = 0.008; Wilcoxon test). The peak exhaled breath temperature, recorded during multiple tidal breaths, increases with an acute exacerbation of COPD, and may be related to accelerated airway inflammation. The application of exhaled breath temperature measurements when monitoring the activity of COPD should be further assessed in longitudinal studies.

journal_name

J Breath Res

authors

Lázár Z,Bikov A,Martinovszky F,Gálffy G,Losonczy G,Horváth I

doi

10.1088/1752-7155/8/4/046002

subject

Has Abstract

pub_date

2014-09-18 00:00:00

pages

046002

issue

4

eissn

1752-7155

issn

1752-7163

journal_volume

8

pub_type

杂志文章
  • Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    abstract::Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applicati...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/8/2/027103

    authors: Tisch U,Haick H

    更新日期:2014-06-01 00:00:00

  • In vitro volatile organic compound profiling using GC×GC-TOFMS to differentiate bacteria associated with lung infections: a proof-of-concept study.

    abstract::Chronic pulmonary infections are the principal cause of morbidity and mortality in individuals with cystic fibrosis (CF). Due to the polymicrobial nature of these infections, the identification of the particular bacterial species responsible is an essential step in diagnosis and treatment. Current diagnostic procedure...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/2/026008

    authors: Nizio KD,Perrault KA,Troobnikoff AN,Ueland M,Shoma S,Iredell JR,Middleton PG,Forbes SL

    更新日期:2016-04-27 00:00:00

  • Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

    abstract::Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advanceme...

    journal_title:Journal of breath research

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/1752-7155/7/3/037109

    authors: Wang Z,Wang C

    更新日期:2013-09-01 00:00:00

  • Exhaled nitric oxide as biomarker of acute lung injury: an unfulfilled promise?

    abstract::The discovery of nitric oxide (NO) as a signalling and regulatory molecule and its subsequent detection in the exhaled breath has not only yielded new mechanistic insights but also diagnostic opportunities and therapeutic targets in several important medical conditions. In diseases involving chronic pulmonary inflamma...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/7/1/017118

    authors: Boshier PR,Hanna GB,Marczin N

    更新日期:2013-03-01 00:00:00

  • Breath acetone change during aerobic exercise is moderated by cardiorespiratory fitness.

    abstract::Exhaled breath acetone (BrAce) was investigated during and after submaximal aerobic exercise as a volatile biomarker for metabolic responsiveness in high and lower-fit individuals in a prospective cohort pilot-study. Twenty healthy adults (19-39 years) with different levels of cardiorespiratory fitness (VO2peak), dete...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/abba6c

    authors: Königstein K,Abegg S,Schorn AN,Weber IC,Derron N,Krebs A,Gerber PA,Schmidt-Trucksäss A,Güntner AT

    更新日期:2020-10-31 00:00:00

  • Two-step investigation of lung cancer detection by sniffer dogs.

    abstract::Early detection of lung cancer (LC) is a priority since LC is characterized by symptoms mimicking other respiratory conditions, but it remains the leading cause of oncological disease death. Properly trained dogs can perceive the volatile organic compounds (VOCs) related to cancer thanks to their acute sense of smell....

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/ab716e

    authors: Mazzola SM,Pirrone F,Sedda G,Gasparri R,Romano R,Spaggiari L,Mariangela A

    更新日期:2020-03-11 00:00:00

  • Genetic influence on the relation between exhaled nitric oxide and pulse wave reflection.

    abstract::Nitric oxide has an important role in the development of the structure and function of the airways and vessel walls. Fractional exhaled nitric oxide (FE(NO)) is inversely related to the markers and risk factors of atherosclerosis. We aimed to estimate the relative contribution of genes and shared and non-shared enviro...

    journal_title:Journal of breath research

    pub_type: 杂志文章,多中心研究

    doi:10.1088/1752-7155/7/2/026008

    authors: Tarnoki DL,Tarnoki AD,Medda E,Littvay L,Lazar Z,Toccaceli V,Fagnani C,Stazi MA,Nisticó L,Brescianini S,Penna L,Lucatelli P,Boatta E,Zini C,Fanelli F,Baracchini C,Meneghetti G,Koller A,Osztovits J,Jermendy G,Preda

    更新日期:2013-06-01 00:00:00

  • Serum and exhaled breath condensate leptin levels in asthmatic and obesity children: a pilot study.

    abstract:BACKGROUND:Recent studies have highlighted the possible involvement of leptin in inflammation. The leptin receptor is also expressed by alveolar macrophages, T lymphocytes and bronchial epitelial cells, suggesting a possible role in the cascade of airway inflammation. OBJECTIVES:The aim of the study was to evaluate th...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aa61c5

    authors: Bodini A,Tenero L,Sandri M,Maffeis C,Piazza M,Zanoni L,Peroni D,Boner A,Piacentini G

    更新日期:2017-09-27 00:00:00

  • Relationship between alveolar nitric oxide concentration in exhaled air and small airway function in COPD.

    abstract::Nitrative stress is thought to be involved in the inflammatory process in COPD airways, and the alveolar nitric oxide concentration (CAlv) has been reported to be increased. However, the CAlv levels are also regulated by gas diffusion at alveolar sites. The aim of the study was to assess the relationship between the C...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/4/046002

    authors: Hirano T,Matsunaga K,Sugiura H,Minakata Y,Koarai A,Akamatsu K,Ichikawa T,Furukawa K,Ichinose M

    更新日期:2013-12-01 00:00:00

  • Bio-inspired nano-engineered strip for semiquantitative FeNO analysis.

    abstract::A point-of-care, non-invasive, low-cost and sensitive nano-biodiagnostic is needed in today's age for rapid and accurate self-diagnosis as well as for the management of asthma, which is advantageous for low resource areas where asthma is prevalent. The objective of this research work was to prepare the miniature, nano...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/ab1faf

    authors: Shende P,Vaidya J,Kulkarni YA

    更新日期:2019-06-25 00:00:00

  • Smart sensor systems for human health breath monitoring applications.

    abstract::Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced c...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/3/037111

    authors: Hunter GW,Xu JC,Biaggi-Labiosa AM,Laskowski D,Dutta PK,Mondal SP,Ward BJ,Makel DB,Liu CC,Chang CW,Dweik RA

    更新日期:2011-09-01 00:00:00

  • Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS.

    abstract::Due to its high sensitivity, compact size and low cost ion mobility spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R  =  90. In this study, we ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/2/026004

    authors: Allers M,Langejuergen J,Gaida A,Holz O,Schuchardt S,Hohlfeld JM,Zimmermann S

    更新日期:2016-04-08 00:00:00

  • Effects of humidity, CO2 and O2 on real-time quantitation of breath biomarkers by means of PTR-ToF-MS.

    abstract::Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) represents an attractive tool for the real-time analysis of VOC profiles in human breath. Quantification of breath VOCs by means of direct MS may be affected by the matrix, as human breath not only contains several hundred VOCs at the ppbV-pptV lev...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aa9eea

    authors: Trefz P,Schubert JK,Miekisch W

    更新日期:2018-03-01 00:00:00

  • Implementation of Fowler's method for end-tidal air sampling.

    abstract::The design, realization and testing of a CO(2)-triggered breath sampler, capable of a separate collection of dead space and end-tidal air on multiple breaths, is presented. This sampling procedure has advantages in terms of the sample volume, insights regarding the origin of compounds, increased reproducibility and hi...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/2/3/037009

    authors: Di Francesco F,Loccioni C,Fioravanti M,Russo A,Pioggia G,Ferro M,Roehrer I,Tabucchi S,Onor M

    更新日期:2008-09-01 00:00:00

  • Translating secondary electrospray ionization-high-resolution mass spectrometry to the clinical environment.

    abstract::While there has been progress in making use of breath tests to guide clinical decision making, the full potential of exhaled breath analysis still remains to be exploited. Here we summarize some of the reasons why this is the case, what we have done so far to overcome some of the existing obstacles, and our vision of ...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7163/aa9ee3

    authors: Singh KD,Del Miguel GV,Gaugg MT,Ibañez AJ,Zenobi R,Kohler M,Frey U,Sinues PM

    更新日期:2018-02-07 00:00:00

  • Influence of age and sex in exhaled breath samples investigated by means of infrared laser absorption spectroscopy.

    abstract::Breath gas analysis provides insight into human metabolism of healthy and ill individuals. As an innovative and non-invasive method, it opens up options to improve diagnostics, monitoring and treatment decisions. Mid-infrared laser absorption spectroscopy is utilized to detect CH(4), H(2)O, CO(2), NH(3) and CH(3)OH in...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/2/027101

    authors: Hannemann M,Antufjew A,Borgmann K,Hempel F,Ittermann T,Welzel S,Weltmann KD,Völzke H,Röpcke J

    更新日期:2011-06-01 00:00:00

  • Injection of deuterated water into the pulmonary/alveolar circulation; measurement of HDO in exhaled breath and implications to breath analysis.

    abstract::The results of experiments are described in which a known quantity of sterile deuterated water is injected directly into the pulmonary circulation via the right internal jugular vein of several haemodialysis patients and the deuterium to hydrogen ratio, D/H, in the exhaled lung water was measured using the flowing aft...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/6/3/036005

    authors: Tan BK,Davies SJ,Spaněl P,Smith D

    更新日期:2012-09-01 00:00:00

  • Effect of atropine sulfate on gastric emptying and gastrocecal transit time evaluated by using the [1-(13)C]acetic acid and lactose-[(13)C]ureide breath test in conscious rats.

    abstract::Breath tests have been used to investigate many physiological functions. Recently, we have developed a breath test system by using a non-invasive technique in conscious rats. In this study, we investigated the effect of atropine sulfate on the gastric emptying and gastrocecal transit time using [1-(13)C]acetic acid an...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/3/4/047003

    authors: Uchida M,Yoshida K,Shimizu K

    更新日期:2009-12-01 00:00:00

  • The impact of chewing gum on halitosis parameters: a systematic review.

    abstract::This study aimed to analyze the impact of chewing gum on halitosis parameters. Three databases were searched with the following focused question: 'Can chewing gum additionally reduce halitosis parameters, such as organoleptic scores and volatile sulfur compounds (VSC), when compared to a control treatment'? Controlled...

    journal_title:Journal of breath research

    pub_type: 杂志文章,meta分析,评审

    doi:10.1088/1752-7163/aa5cc2

    authors: Muniz FW,Friedrich SA,Silveira CF,Rösing CK

    更新日期:2017-02-17 00:00:00

  • Endogenous volatile organic compounds in breath and blood of healthy volunteers: examining breath analysis as a surrogate for blood measurements.

    abstract::To investigate the premise that levels of endogenous volatile organic compounds (VOC) in breath reflect those in blood, the concentration of acetone and isoprene were measured in radial arterial blood, peripheral venous blood and breath samples from ten healthy volunteers. Coefficients of repeatability as a percentage...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/3/2/027005

    authors: O'Hara ME,Clutton-Brock TH,Green S,Mayhew CA

    更新日期:2009-06-01 00:00:00

  • Prototype of a breath-based analysis system for medication compliance monitoring.

    abstract::Poor compliance to prescribed medication regimens in clinical trials continues to be a major obstacle to drug development success and cost reduction, and there is no gold standard technology that is cheap and effective to reliably measure drug compliance. This paper presents a new drug compliance scheme based on the d...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/1/2/026006

    authors: Meka VV,Lutz BJ,Melker RJ,Euliano NR

    更新日期:2007-12-01 00:00:00

  • Instant effects of changing body positions on compositions of exhaled breath.

    abstract::Concentrations of exhaled volatile organic compounds (VOCs) may depend not only on biochemical or pathologic processes but also on physiological parameters. As breath sampling may be done in different body positions, effects of the sampling position on exhaled VOC concentrations were investigated by means of real-time...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/4/047105

    authors: Sukul P,Trefz P,Kamysek S,Schubert JK,Miekisch W

    更新日期:2015-11-19 00:00:00

  • Secondary electrospray ionization-mass spectrometry and a novel statistical bioinformatic approach identifies a cancer-related profile in exhaled breath of breast cancer patients: a pilot study.

    abstract::Breath analysis represents a new frontier in medical diagnosis and a powerful tool for cancer biomarker discovery due to the recent development of analytical platforms for the detection and identification of human exhaled volatile compounds. Statistical and bioinformatic tools may represent an effective complement to ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/3/031001

    authors: Martinez-Lozano Sinues P,Landoni E,Miceli R,Dibari VF,Dugo M,Agresti R,Tagliabue E,Cristoni S,Orlandi R

    更新日期:2015-09-21 00:00:00

  • Towards standardization in the analysis of breath gas volatiles.

    abstract::Despite growing interest and considerable progress in breath research over the last decade, standardized practices for the sampling and analysis of breath gas volatiles remain elusive. The primary reasons for this are (a) the rich chemical diversity of exhaled breath that covers an extensive range of volatile organic ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/8/3/037101

    authors: Herbig J,Beauchamp J

    更新日期:2014-09-01 00:00:00

  • Profile of volatile organic compounds in exhaled breath changes as a result of gluten-free diet.

    abstract::In the present longitudinal study, we followed volatile organic compounds (VOCs) excreted in exhaled breath of 20 healthy individuals over time, while adhering to a gluten-free diet for 4 weeks prior to adherence to a normal diet. We used gas chromatography coupled with mass spectrometry (TD-GC-tof-MS) in combination ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/3/037104

    authors: Baranska A,Tigchelaar E,Smolinska A,Dallinga JW,Moonen EJ,Dekens JA,Wijmenga C,Zhernakova A,van Schooten FJ

    更新日期:2013-09-01 00:00:00

  • Breath testing for intra-abdominal infection: appendicitis, a preliminary study.

    abstract::In the current pilot study we aimed to determine whether breath analysis could be used to help recognise intra-abdominal infection, using acute appendicitis as an exemplar condition. Our study included 53 patients (aged 18-88 years) divided into three groups: appendix group, 26 (13 male) patients suffering from acute ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/abba88

    authors: Andrews BT,Das P,Denzer W,Ritchie GA,Peverall R,Hamade AM,Hancock G

    更新日期:2020-10-22 00:00:00

  • An increase in exhaled CO concentration in systemic inflammation/sepsis.

    abstract::Despite recent progress in Critical Care Medicine, sepsis is still a major medical problem with a high rate of mortality and morbidity especially in intensive care units. Oxidative stress induced by inflammation associated with sepsis causes degradation of heme protein, increases microsomal free heme content, promotes...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/4/4/047103

    authors: Morimatsu H,Takahashi T,Matsusaki T,Hayashi M,Matsumi J,Shimizu H,Matsumi M,Morita K

    更新日期:2010-12-01 00:00:00

  • Study of the art: canine olfaction used for cancer detection on the basis of breath odour. Perspectives and limitations.

    abstract::Experimental studies using trained dogs to identify breath odour markers of human cancer, published in the recent decade, have been analyzed and compared with the authors' own results. Particular published studies differ as regards the experimental setup, kind of odour samples (breath, urine, tumor tissue, serum), sam...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/9/2/027001

    authors: Jezierski T,Walczak M,Ligor T,Rudnicka J,Buszewski B

    更新日期:2015-05-06 00:00:00

  • Exhaled breath condensate for lung cancer protein analysis: a review of methods and biomarkers.

    abstract::Lung cancer is a leading cause of cancer-related deaths worldwide, and is considered one of the most aggressive human cancers, with a 5 year overall survival of 10-15%. Early diagnosis of lung cancer is ideal; however, it is still uncertain as to what technique will prove successful in the systematic screening of high...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/10/3/034001

    authors: Hayes SA,Haefliger S,Harris B,Pavlakis N,Clarke SJ,Molloy MP,Howell VM

    更新日期:2016-07-05 00:00:00

  • Measurements of lactate in exhaled breath condensate at rest and after maximal exercise in young and healthy subjects.

    abstract::Arterial lactate concentrations, taken as indicators of physical fitness, in athletes as well as in patients with cardio-respiratory or metabolic diseases, are measured invasively from arterialized ear lobe blood. Currently developed micro enzyme detectors permit a non-invasive measurement of hypoxia-related metabolit...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/4/1/017105

    authors: Marek EM,Volke J,Hawener I,Platen P,Mückenhoff K,Marek W

    更新日期:2010-03-01 00:00:00