Online breath analysis using metal oxide semiconductor sensors (electronic nose) for diagnosis of lung cancer.

Abstract:

:The analysis of exhaled breath is drawing a high degree of interest in the diagnostics of various diseases, including lung cancer. Electronic nose (E-nose) technology is one of the perspective approaches in the field due to its relative simplicity and cost efficiency. The use of an E-nose together with pattern recognition algorithms allow 'breath-prints' to be discriminated. The aim of this study was to develop an efficient online E-nose-based lung cancer diagnostic method via exhaled breath analysis with the use of some statistical classification methods. A developed multisensory system consisting of six metal oxide chemoresistance gas sensors was employed in three temperature regimes. This study involved 118 individuals: 65 in the lung cancer group (cytologically verified) and 53 in the healthy control group. The exhaled breath samples of the volunteers were analysed using the developed E-nose system. The dataset obtained, consisting of the sensor responses, was pre-processed and split into training (70%) and test (30%) subsets. The training data was used to fit the classification models; the test data was used for the estimation of prediction possibility. Logistic regression was found to be an adequate data-processing approach. The performance of the developed method was promising for the screening purposes (sensitivity-95.0%, specificity-100.0%, accuracy-97.2%). This shows the applicability of the gas-sensitive sensor array for the exhaled breath diagnostics. Metal oxide sensors are highly sensitive, low-cost and stable, and their poor sensitivity can be enhanced by integrating them with machine learning algorithms, as can be seen in this study. All experiments were carried out with the permission of the N.N. Petrov Research Institute of Oncology ethics committee no. 15/83 dated March 15, 2017.

journal_name

J Breath Res

authors

Kononov A,Korotetsky B,Jahatspanian I,Gubal A,Vasiliev A,Arsenjev A,Nefedov A,Barchuk A,Gorbunov I,Kozyrev K,Rassadina A,Iakovleva E,Sillanpää M,Safaei Z,Ivanenko N,Stolyarova N,Chuchina V,Ganeev A

doi

10.1088/1752-7163/ab433d

subject

Has Abstract

pub_date

2019-10-23 00:00:00

pages

016004

issue

1

eissn

1752-7155

issn

1752-7163

journal_volume

14

pub_type

杂志文章
  • Cancerous glucose metabolism in lung cancer-evidence from exhaled breath analysis.

    abstract::Cancer cells prefer hyperglycolysis versus oxidative phosphorylation, even in the presence of oxygen. This phenomenon is used through the FDG-PET scans, and may affect the exhaled volatile signature. This study investigates the volatile signature in lung cancer (LC) before and after an oral glucose tolerance test (OGT...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/2/026012

    authors: Feinberg T,Alkoby-Meshulam L,Herbig J,Cancilla JC,Torrecilla JS,Gai Mor N,Bar J,Ilouze M,Haick H,Peled N

    更新日期:2016-06-07 00:00:00

  • Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults.

    abstract::Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and pot...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/4/047109

    authors: Spacek LA,Mudalel M,Tittel F,Risby TH,Solga SF

    更新日期:2015-12-14 00:00:00

  • Measurements of lactate in exhaled breath condensate at rest and after maximal exercise in young and healthy subjects.

    abstract::Arterial lactate concentrations, taken as indicators of physical fitness, in athletes as well as in patients with cardio-respiratory or metabolic diseases, are measured invasively from arterialized ear lobe blood. Currently developed micro enzyme detectors permit a non-invasive measurement of hypoxia-related metabolit...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/4/1/017105

    authors: Marek EM,Volke J,Hawener I,Platen P,Mückenhoff K,Marek W

    更新日期:2010-03-01 00:00:00

  • Breath acetone change during aerobic exercise is moderated by cardiorespiratory fitness.

    abstract::Exhaled breath acetone (BrAce) was investigated during and after submaximal aerobic exercise as a volatile biomarker for metabolic responsiveness in high and lower-fit individuals in a prospective cohort pilot-study. Twenty healthy adults (19-39 years) with different levels of cardiorespiratory fitness (VO2peak), dete...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/abba6c

    authors: Königstein K,Abegg S,Schorn AN,Weber IC,Derron N,Krebs A,Gerber PA,Schmidt-Trucksäss A,Güntner AT

    更新日期:2020-10-31 00:00:00

  • Implementation of Fowler's method for end-tidal air sampling.

    abstract::The design, realization and testing of a CO(2)-triggered breath sampler, capable of a separate collection of dead space and end-tidal air on multiple breaths, is presented. This sampling procedure has advantages in terms of the sample volume, insights regarding the origin of compounds, increased reproducibility and hi...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/2/3/037009

    authors: Di Francesco F,Loccioni C,Fioravanti M,Russo A,Pioggia G,Ferro M,Roehrer I,Tabucchi S,Onor M

    更新日期:2008-09-01 00:00:00

  • Effects of humidity, CO2 and O2 on real-time quantitation of breath biomarkers by means of PTR-ToF-MS.

    abstract::Proton transfer reaction time-of-flight mass spectrometry (PTR-ToF-MS) represents an attractive tool for the real-time analysis of VOC profiles in human breath. Quantification of breath VOCs by means of direct MS may be affected by the matrix, as human breath not only contains several hundred VOCs at the ppbV-pptV lev...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aa9eea

    authors: Trefz P,Schubert JK,Miekisch W

    更新日期:2018-03-01 00:00:00

  • The use of a gas chromatograph coupled to a metal oxide sensor for rapid assessment of stool samples from irritable bowel syndrome and inflammatory bowel disease patients.

    abstract::There is much clinical interest in the development of a low-cost and reliable test for diagnosing inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), two very distinct diseases that can present with similar symptoms. The assessment of stool samples for the diagnosis of gastro-intestinal diseases is in...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/8/2/026001

    authors: Shepherd SF,McGuire ND,de Lacy Costello BP,Ewen RJ,Jayasena DH,Vaughan K,Ahmed I,Probert CS,Ratcliffe NM

    更新日期:2014-06-01 00:00:00

  • Breath markers for therapeutic radiation.

    abstract::Radiation dose is important in radiotherapy. Too little, and the treatment is not effective, too much causes radiation toxicity. A biochemical measurement of the effect of radiotherapy would be useful in personalisation of this treatment. This study evaluated changes in exhaled breath volatile organic compounds (VOC) ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aba816

    authors: Salman D,Eddleston M,Darnley K,Nailon WH,McLaren DB,Hadjithelki A,Ruszkiewicz D,Langejuergen J,Alkhalifa Y,Phillips I,Thomas CLP

    更新日期:2020-10-24 00:00:00

  • Responses measured in the exhaled breath of human volunteers acutely exposed to ozone and diesel exhaust.

    abstract::Exhaled breath collection is used to identify and monitor inflammatory or oxidative components in breath. Exhaled breath sample collection is noninvasive and would greatly benefit human pollutant exposure research. We demonstrate the efficacy of exhaled breath collection and analysis in two human exposure studies to o...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/2/3/037019

    authors: Sawyer K,Samet JM,Ghio AJ,Pleil JD,Madden MC

    更新日期:2008-09-01 00:00:00

  • Smart sensor systems for human health breath monitoring applications.

    abstract::Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced c...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/3/037111

    authors: Hunter GW,Xu JC,Biaggi-Labiosa AM,Laskowski D,Dutta PK,Mondal SP,Ward BJ,Makel DB,Liu CC,Chang CW,Dweik RA

    更新日期:2011-09-01 00:00:00

  • Influence of age and sex in exhaled breath samples investigated by means of infrared laser absorption spectroscopy.

    abstract::Breath gas analysis provides insight into human metabolism of healthy and ill individuals. As an innovative and non-invasive method, it opens up options to improve diagnostics, monitoring and treatment decisions. Mid-infrared laser absorption spectroscopy is utilized to detect CH(4), H(2)O, CO(2), NH(3) and CH(3)OH in...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/2/027101

    authors: Hannemann M,Antufjew A,Borgmann K,Hempel F,Ittermann T,Welzel S,Weltmann KD,Völzke H,Röpcke J

    更新日期:2011-06-01 00:00:00

  • Increased volume of conducting airways in idiopathic pulmonary fibrosis is independent of disease severity: a volumetric capnography study.

    abstract::Bronchiectasis, bronchiolectasis, and bronchiolisation of alveolar regions are salient features of idiopathic pulmonary fibrosis (IPF). We asked whether IPF was associated with physiological changes consistent with increases in the volume of conducting airways, and whether airway volume was related to the severity of ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/1/016005

    authors: Plantier L,Debray MP,Estellat C,Flamant M,Roy C,Bancal C,Borie R,Israël-Biet D,Mal H,Crestani B,Delclaux C

    更新日期:2016-02-01 00:00:00

  • Detection of Staphylococcus aureus in cystic fibrosis patients using breath VOC profiles.

    abstract::Staphylococcus aureus (S. aureus) is a common bacterium infecting children with cystic fibrosis (CF). Since current detection methods are difficult to perform in children, there is need for an alternative. This proof of concept study investigates whether breath profiles can discriminate between S. aureus infected and ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/4/046014

    authors: Neerincx AH,Geurts BP,van Loon J,Tiemes V,Jansen JJ,Harren FJ,Kluijtmans LA,Merkus PJ,Cristescu SM,Buydens LM,Wevers RA

    更新日期:2016-11-30 00:00:00

  • Two-step investigation of lung cancer detection by sniffer dogs.

    abstract::Early detection of lung cancer (LC) is a priority since LC is characterized by symptoms mimicking other respiratory conditions, but it remains the leading cause of oncological disease death. Properly trained dogs can perceive the volatile organic compounds (VOCs) related to cancer thanks to their acute sense of smell....

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/ab716e

    authors: Mazzola SM,Pirrone F,Sedda G,Gasparri R,Romano R,Spaggiari L,Mariangela A

    更新日期:2020-03-11 00:00:00

  • Onset of action of inhaled glucocorticoids on bronchial and alveolar nitric oxide output.

    abstract::Fractional exhaled nitric oxide (FENO) is a marker of airway inflammation. Measuring FENO at multiple flow rates enables calculation of NO parameters: bronchial NO output (J awNO), bronchial wall (C awNO) and alveolar (C ANO) NO concentrations, and bronchial diffusion factor of NO (D awNO). FENO is known to rapidly re...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/abc054

    authors: Karvonen T,Sepponen-Lavikko A,Holm K,Schultz R,Moilanen E,Lehtimäki L

    更新日期:2020-11-05 00:00:00

  • Methodology validation, intra-subject reproducibility and stability of exhaled volatile organic compounds.

    abstract::Robust methods for breath sampling and analysis are required for potential clinical applications. We have evaluated an improved sampling and experimental design, assessing instrumental and biological variability within and across breath measurements. Calibration curves for selected relevant volatile organic compounds...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/6/2/026002

    authors: Basanta M,Ibrahim B,Douce D,Morris M,Woodcock A,Fowler SJ

    更新日期:2012-06-01 00:00:00

  • Prototype of a breath-based analysis system for medication compliance monitoring.

    abstract::Poor compliance to prescribed medication regimens in clinical trials continues to be a major obstacle to drug development success and cost reduction, and there is no gold standard technology that is cheap and effective to reliably measure drug compliance. This paper presents a new drug compliance scheme based on the d...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/1/2/026006

    authors: Meka VV,Lutz BJ,Melker RJ,Euliano NR

    更新日期:2007-12-01 00:00:00

  • Bio-inspired nano-engineered strip for semiquantitative FeNO analysis.

    abstract::A point-of-care, non-invasive, low-cost and sensitive nano-biodiagnostic is needed in today's age for rapid and accurate self-diagnosis as well as for the management of asthma, which is advantageous for low resource areas where asthma is prevalent. The objective of this research work was to prepare the miniature, nano...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/ab1faf

    authors: Shende P,Vaidya J,Kulkarni YA

    更新日期:2019-06-25 00:00:00

  • Aerobic exercise in polluted urban environments: effects on airway defense mechanisms in young healthy amateur runners.

    abstract::In this study, the effects of aerobic exercise on the upper airways and their defense mechanisms were investigated in athletes. The athletes ran in two different environments: the downtown streets of the city of São Paulo (Street), more polluted, and an urban forest (Forest), less polluted. Thirty-eight young healthy ...

    journal_title:Journal of breath research

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1752-7163/10/4/046018

    authors: Cavalcante de Sá M,Nakagawa NK,Saldiva de André CD,Carvalho-Oliveira R,de Santana Carvalho T,Nicola ML,de André PA,Nascimento Saldiva PH,Vaisberg M

    更新日期:2016-12-21 00:00:00

  • Study of the art: canine olfaction used for cancer detection on the basis of breath odour. Perspectives and limitations.

    abstract::Experimental studies using trained dogs to identify breath odour markers of human cancer, published in the recent decade, have been analyzed and compared with the authors' own results. Particular published studies differ as regards the experimental setup, kind of odour samples (breath, urine, tumor tissue, serum), sam...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/9/2/027001

    authors: Jezierski T,Walczak M,Ligor T,Rudnicka J,Buszewski B

    更新日期:2015-05-06 00:00:00

  • Towards standardization in the analysis of breath gas volatiles.

    abstract::Despite growing interest and considerable progress in breath research over the last decade, standardized practices for the sampling and analysis of breath gas volatiles remain elusive. The primary reasons for this are (a) the rich chemical diversity of exhaled breath that covers an extensive range of volatile organic ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/8/3/037101

    authors: Herbig J,Beauchamp J

    更新日期:2014-09-01 00:00:00

  • Methodological considerations for large-scale breath analysis studies: lessons from the U-BIOPRED severe asthma project.

    abstract::Methods for breath sampling and analysis require robust quality assessment to minimise the risk of false discoveries. Planning large-scale multi-site breath metabolite profiling studies also requires careful consideration of systematic and random variation as a result of sampling and analysis techniques. In this study...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aae557

    authors: Ahmed WM,Brinkman P,Weda H,Knobel HH,Xu Y,Nijsen TM,Goodacre R,Rattray N,Vink TJ,Santonico M,Pennazza G,Montuschi P,Sterk PJ,Fowler SJ

    更新日期:2018-10-30 00:00:00

  • Screening for emphysema via exhaled volatile organic compounds.

    abstract::Chronic obstructive pulmonary disease (COPD)/emphysema risk groups are well defined and screening allows for early identification of disease. The capability of exhaled volatile organic compounds (VOCs) to detect emphysema, as found by computed tomography (CT) in current and former heavy smokers participating in a lung...

    journal_title:Journal of breath research

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1088/1752-7155/5/4/046009

    authors: Cristescu SM,Gietema HA,Blanchet L,Kruitwagen CL,Munnik P,van Klaveren RJ,Lammers JW,Buydens L,Harren FJ,Zanen P

    更新日期:2011-12-01 00:00:00

  • Breath carbonyl levels in a human population of seven hundred participants.

    abstract::Oxidative stress is associated with numerous health conditions and disorders, and aldehydes are known biomarkers of oxidative stress that can be non-invasively measured in exhaled human breath. Few studies report breath aldehyde levels in human populations, and none claim participant numbers in the hundreds or more. F...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/ab8865

    authors: McCartney MM,Thompson CJ,Klein LR,Ngo JH,Seibel JD,Fabia F,Simms LA,Borras E,Young BS,Lara J,Turnlund MW,Nguyen AP,Kenyon NJ,Davis CE

    更新日期:2020-07-21 00:00:00

  • Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS.

    abstract::Due to its high sensitivity, compact size and low cost ion mobility spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R  =  90. In this study, we ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/2/026004

    authors: Allers M,Langejuergen J,Gaida A,Holz O,Schuchardt S,Hohlfeld JM,Zimmermann S

    更新日期:2016-04-08 00:00:00

  • Volatile organic compound markers of psychological stress in skin: a pilot study.

    abstract::The forehead was studied as a possible sampling site for capturing changes in volatile organic compound (VOC) profiles associated with psychological-stress. Skin-VOCs were sampled with a polydimethylsilicone (PDMS)-coupon and the resulting VOCs were recovered and analysed with two-stage thermal desorption gas chromato...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/4/046012

    authors: Martin HJ,Turner MA,Bandelow S,Edwards L,Riazanskaia S,Thomas CL

    更新日期:2016-11-21 00:00:00

  • An increase in exhaled CO concentration in systemic inflammation/sepsis.

    abstract::Despite recent progress in Critical Care Medicine, sepsis is still a major medical problem with a high rate of mortality and morbidity especially in intensive care units. Oxidative stress induced by inflammation associated with sepsis causes degradation of heme protein, increases microsomal free heme content, promotes...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/4/4/047103

    authors: Morimatsu H,Takahashi T,Matsusaki T,Hayashi M,Matsumi J,Shimizu H,Matsumi M,Morita K

    更新日期:2010-12-01 00:00:00

  • Quantification of trace levels of the potential cancer biomarkers formaldehyde, acetaldehyde and propanol in breath by SIFT-MS.

    abstract::The sensitivity of selected ion flow tube mass spectrometry, SIFT-MS, has been increased such that it is now possible to detect metabolites present at a part-per-billion, ppb, level in single breath exhalations. However, to utilize this improved sensitivity, the overlaps (coincidences) of those ions resulting from int...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/2/4/046003

    authors: Spaněl P,Smith D

    更新日期:2008-12-01 00:00:00

  • Exhaled nitric oxide as biomarker of acute lung injury: an unfulfilled promise?

    abstract::The discovery of nitric oxide (NO) as a signalling and regulatory molecule and its subsequent detection in the exhaled breath has not only yielded new mechanistic insights but also diagnostic opportunities and therapeutic targets in several important medical conditions. In diseases involving chronic pulmonary inflamma...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/7/1/017118

    authors: Boshier PR,Hanna GB,Marczin N

    更新日期:2013-03-01 00:00:00

  • Secondary electrospray ionization-mass spectrometry and a novel statistical bioinformatic approach identifies a cancer-related profile in exhaled breath of breast cancer patients: a pilot study.

    abstract::Breath analysis represents a new frontier in medical diagnosis and a powerful tool for cancer biomarker discovery due to the recent development of analytical platforms for the detection and identification of human exhaled volatile compounds. Statistical and bioinformatic tools may represent an effective complement to ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/3/031001

    authors: Martinez-Lozano Sinues P,Landoni E,Miceli R,Dibari VF,Dugo M,Agresti R,Tagliabue E,Cristoni S,Orlandi R

    更新日期:2015-09-21 00:00:00