Exhaled nitric oxide as biomarker of acute lung injury: an unfulfilled promise?

Abstract:

:The discovery of nitric oxide (NO) as a signalling and regulatory molecule and its subsequent detection in the exhaled breath has not only yielded new mechanistic insights but also diagnostic opportunities and therapeutic targets in several important medical conditions. In diseases involving chronic pulmonary inflammation such as asthma that affects millions worldwide, exhaled NO has achieved spectacular successes with patients currently owning handheld devices and monitoring inflammatory aspects of their conditions in their own homes. This has been facilitated by recognition by regulatory bodies, scientific and clinical societies and insurance companies. While characteristic changes in exhaled NO have also been observed in acute lung injury (ALI), the promise of exhaled NO as a surrogate biomarker of this life-threatening disease has not been achieved. In this work, we have analysed factors contributing to successes of exhaled NO in the asthma field and contrasted these on the ALI field. We provide a snapshot of current status of exhaled NO field in ALI and propose a framework for definite evaluation of exhaled NO as a clinically useful biomarker.

journal_name

J Breath Res

authors

Boshier PR,Hanna GB,Marczin N

doi

10.1088/1752-7155/7/1/017118

subject

Has Abstract

pub_date

2013-03-01 00:00:00

pages

017118

issue

1

eissn

1752-7155

issn

1752-7163

journal_volume

7

pub_type

杂志文章,评审
  • Measurement of exhaled volatile organic compounds from patients with chronic obstructive pulmonary disease (COPD) using closed gas loop GC-IMS and GC-APCI-MS.

    abstract::Due to its high sensitivity, compact size and low cost ion mobility spectrometry (IMS) has the potential to become a point-of-care breath analyzer. Therefore, we developed a prototype of a compact, closed gas loop IMS with gas chromatographic (GC) pre-separation and high resolving power of R  =  90. In this study, we ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/2/026004

    authors: Allers M,Langejuergen J,Gaida A,Holz O,Schuchardt S,Hohlfeld JM,Zimmermann S

    更新日期:2016-04-08 00:00:00

  • Measurements of lactate in exhaled breath condensate at rest and after maximal exercise in young and healthy subjects.

    abstract::Arterial lactate concentrations, taken as indicators of physical fitness, in athletes as well as in patients with cardio-respiratory or metabolic diseases, are measured invasively from arterialized ear lobe blood. Currently developed micro enzyme detectors permit a non-invasive measurement of hypoxia-related metabolit...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/4/1/017105

    authors: Marek EM,Volke J,Hawener I,Platen P,Mückenhoff K,Marek W

    更新日期:2010-03-01 00:00:00

  • Secondary electrospray ionization-mass spectrometry and a novel statistical bioinformatic approach identifies a cancer-related profile in exhaled breath of breast cancer patients: a pilot study.

    abstract::Breath analysis represents a new frontier in medical diagnosis and a powerful tool for cancer biomarker discovery due to the recent development of analytical platforms for the detection and identification of human exhaled volatile compounds. Statistical and bioinformatic tools may represent an effective complement to ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/3/031001

    authors: Martinez-Lozano Sinues P,Landoni E,Miceli R,Dibari VF,Dugo M,Agresti R,Tagliabue E,Cristoni S,Orlandi R

    更新日期:2015-09-21 00:00:00

  • A collection system for dry solid residues from exhaled breath for analysis via atomic force microscopy.

    abstract::Exhaled air contains sub-micron droplets of lung liquid, which potentially bear biomarkers of lung diseases. After dehydration they form dry residue particles (DRPs). As a first step in developing techniques to characterize individual DRPs, a new electrostatic collector was designed in which DRPs are charged within a ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aa5359

    authors: Morozov VN,Mikheev AY

    更新日期:2017-01-09 00:00:00

  • Breath markers for therapeutic radiation.

    abstract::Radiation dose is important in radiotherapy. Too little, and the treatment is not effective, too much causes radiation toxicity. A biochemical measurement of the effect of radiotherapy would be useful in personalisation of this treatment. This study evaluated changes in exhaled breath volatile organic compounds (VOC) ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aba816

    authors: Salman D,Eddleston M,Darnley K,Nailon WH,McLaren DB,Hadjithelki A,Ruszkiewicz D,Langejuergen J,Alkhalifa Y,Phillips I,Thomas CLP

    更新日期:2020-10-24 00:00:00

  • Instant effects of changing body positions on compositions of exhaled breath.

    abstract::Concentrations of exhaled volatile organic compounds (VOCs) may depend not only on biochemical or pathologic processes but also on physiological parameters. As breath sampling may be done in different body positions, effects of the sampling position on exhaled VOC concentrations were investigated by means of real-time...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/4/047105

    authors: Sukul P,Trefz P,Kamysek S,Schubert JK,Miekisch W

    更新日期:2015-11-19 00:00:00

  • Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults.

    abstract::Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and pot...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/9/4/047109

    authors: Spacek LA,Mudalel M,Tittel F,Risby TH,Solga SF

    更新日期:2015-12-14 00:00:00

  • Endogenous volatile organic compounds in breath and blood of healthy volunteers: examining breath analysis as a surrogate for blood measurements.

    abstract::To investigate the premise that levels of endogenous volatile organic compounds (VOC) in breath reflect those in blood, the concentration of acetone and isoprene were measured in radial arterial blood, peripheral venous blood and breath samples from ten healthy volunteers. Coefficients of repeatability as a percentage...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/3/2/027005

    authors: O'Hara ME,Clutton-Brock TH,Green S,Mayhew CA

    更新日期:2009-06-01 00:00:00

  • Increased concentrations of breath haloamines are not detectable in airways inflammation using SIFT-MS.

    abstract::The haloamines, including the chloramines (H(2)NCl, HNCl(2)) and bromamine (H(2)NBr), are diffusible gases that are likely to be produced during inflammation and so may be present as markers of lung inflammation on breath. Although haloamines are quite reactive, it is possible to measure these compounds in humid sampl...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/3/037105

    authors: Storer MK,Dummer JD,Cook J,McEwan M,Epton MJ

    更新日期:2011-09-01 00:00:00

  • The use of a gas chromatograph coupled to a metal oxide sensor for rapid assessment of stool samples from irritable bowel syndrome and inflammatory bowel disease patients.

    abstract::There is much clinical interest in the development of a low-cost and reliable test for diagnosing inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), two very distinct diseases that can present with similar symptoms. The assessment of stool samples for the diagnosis of gastro-intestinal diseases is in...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/8/2/026001

    authors: Shepherd SF,McGuire ND,de Lacy Costello BP,Ewen RJ,Jayasena DH,Vaughan K,Ahmed I,Probert CS,Ratcliffe NM

    更新日期:2014-06-01 00:00:00

  • Prototype of a breath-based analysis system for medication compliance monitoring.

    abstract::Poor compliance to prescribed medication regimens in clinical trials continues to be a major obstacle to drug development success and cost reduction, and there is no gold standard technology that is cheap and effective to reliably measure drug compliance. This paper presents a new drug compliance scheme based on the d...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/1/2/026006

    authors: Meka VV,Lutz BJ,Melker RJ,Euliano NR

    更新日期:2007-12-01 00:00:00

  • Airborne virus detection by a sensing system using a disposable integrated impaction device.

    abstract::There are many respiratory infections such as influenza that cause epidemics. These respiratory infection epidemics can be effectively prevented by determining the presence or absence of infections in patients using frequent tests. We think that self-diagnosis may be possible using a system that can collect and detect...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/3/036009

    authors: Takenaka K,Togashi S,Miyake R,Sakaguchi T,Hide M

    更新日期:2016-07-22 00:00:00

  • Smart sensor systems for human health breath monitoring applications.

    abstract::Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced c...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/5/3/037111

    authors: Hunter GW,Xu JC,Biaggi-Labiosa AM,Laskowski D,Dutta PK,Mondal SP,Ward BJ,Makel DB,Liu CC,Chang CW,Dweik RA

    更新日期:2011-09-01 00:00:00

  • Microbial volatile compounds in health and disease conditions.

    abstract::Microbial cultures and/or microbial associated diseases often have a characteristic smell. Volatile organic compounds (VOCs) are produced by all microorganisms as part of their normal metabolism. The types and classes of VOC produced is wide, including fatty acids and their derivatives (e.g. hydrocarbons, aliphatic al...

    journal_title:Journal of breath research

    pub_type: 杂志文章,评审

    doi:10.1088/1752-7155/6/2/024001

    authors: Thorn RM,Greenman J

    更新日期:2012-06-01 00:00:00

  • The impact of chewing gum on halitosis parameters: a systematic review.

    abstract::This study aimed to analyze the impact of chewing gum on halitosis parameters. Three databases were searched with the following focused question: 'Can chewing gum additionally reduce halitosis parameters, such as organoleptic scores and volatile sulfur compounds (VSC), when compared to a control treatment'? Controlled...

    journal_title:Journal of breath research

    pub_type: 杂志文章,meta分析,评审

    doi:10.1088/1752-7163/aa5cc2

    authors: Muniz FW,Friedrich SA,Silveira CF,Rösing CK

    更新日期:2017-02-17 00:00:00

  • Methodology validation, intra-subject reproducibility and stability of exhaled volatile organic compounds.

    abstract::Robust methods for breath sampling and analysis are required for potential clinical applications. We have evaluated an improved sampling and experimental design, assessing instrumental and biological variability within and across breath measurements. Calibration curves for selected relevant volatile organic compounds...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/6/2/026002

    authors: Basanta M,Ibrahim B,Douce D,Morris M,Woodcock A,Fowler SJ

    更新日期:2012-06-01 00:00:00

  • Profile of volatile organic compounds in exhaled breath changes as a result of gluten-free diet.

    abstract::In the present longitudinal study, we followed volatile organic compounds (VOCs) excreted in exhaled breath of 20 healthy individuals over time, while adhering to a gluten-free diet for 4 weeks prior to adherence to a normal diet. We used gas chromatography coupled with mass spectrometry (TD-GC-tof-MS) in combination ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/3/037104

    authors: Baranska A,Tigchelaar E,Smolinska A,Dallinga JW,Moonen EJ,Dekens JA,Wijmenga C,Zhernakova A,van Schooten FJ

    更新日期:2013-09-01 00:00:00

  • Relationship between alveolar nitric oxide concentration in exhaled air and small airway function in COPD.

    abstract::Nitrative stress is thought to be involved in the inflammatory process in COPD airways, and the alveolar nitric oxide concentration (CAlv) has been reported to be increased. However, the CAlv levels are also regulated by gas diffusion at alveolar sites. The aim of the study was to assess the relationship between the C...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/4/046002

    authors: Hirano T,Matsunaga K,Sugiura H,Minakata Y,Koarai A,Akamatsu K,Ichikawa T,Furukawa K,Ichinose M

    更新日期:2013-12-01 00:00:00

  • Increased volume of conducting airways in idiopathic pulmonary fibrosis is independent of disease severity: a volumetric capnography study.

    abstract::Bronchiectasis, bronchiolectasis, and bronchiolisation of alveolar regions are salient features of idiopathic pulmonary fibrosis (IPF). We asked whether IPF was associated with physiological changes consistent with increases in the volume of conducting airways, and whether airway volume was related to the severity of ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/1/016005

    authors: Plantier L,Debray MP,Estellat C,Flamant M,Roy C,Bancal C,Borie R,Israël-Biet D,Mal H,Crestani B,Delclaux C

    更新日期:2016-02-01 00:00:00

  • Clinical breath analysis: discriminating between human endogenous compounds and exogenous (environmental) chemical confounders.

    abstract::Volatile organic compounds (VOCs) in exhaled breath originate from current or previous environmental exposures (exogenous compounds) and internal metabolic (anabolic and catabolic) production (endogenous compounds). The origins of certain VOCs in breath presumed to be endogenous have been proposed to be useful as prec...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/1/017107

    authors: Pleil JD,Stiegel MA,Risby TH

    更新日期:2013-03-01 00:00:00

  • Atmospheric pressure chemical ionization mass spectrometry of pyridine and isoprene: potential breath exposure and disease biomarkers.

    abstract::Volatile organic compounds (VOCs) in exhaled human breath can serve as potential disease-specific and exposure biomarkers and therefore can reveal information about a subject's health and environment. Pyridine, a VOC marker for exposure to tobacco smoke, and isoprene, a liver disease biomarker, were studied using atmo...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/7/2/026005

    authors: Kapishon V,Koyanagi GK,Blagojevic V,Bohme DK

    更新日期:2013-06-01 00:00:00

  • Injection of deuterated water into the pulmonary/alveolar circulation; measurement of HDO in exhaled breath and implications to breath analysis.

    abstract::The results of experiments are described in which a known quantity of sterile deuterated water is injected directly into the pulmonary circulation via the right internal jugular vein of several haemodialysis patients and the deuterium to hydrogen ratio, D/H, in the exhaled lung water was measured using the flowing aft...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/6/3/036005

    authors: Tan BK,Davies SJ,Spaněl P,Smith D

    更新日期:2012-09-01 00:00:00

  • Power-efficient self-cleaning hydrophilic condenser surface for portable exhaled breath condensate (EBC) metabolomic sampling.

    abstract::In this work, we present a hydrophilic self-cleaning condenser surface for the collection of biological and environmental aerosol samples. The condenser is installed in a battery-operated hand-held breath sampling device. The device performance is characterized by the collection and analysis of exhaled breath samples ...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aac5a5

    authors: Zamuruyev KO,Schmidt AJ,Borras E,McCartney MM,Schivo M,Kenyon NJ,Delplanque JP,Davis CE

    更新日期:2018-06-08 00:00:00

  • Changes in oxidative stress during outpatient surgery.

    abstract::Reactive oxygen species are associated with tissue inflammation and injury. Our laboratory has demonstrated that ethane, a stable product of lipid peroxidation, in exhaled breath can be used to measure total body oxidative stress. Herein patients were studied who underwent outpatient surgery, laproscopic bilateral tub...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/3/1/016002

    authors: Brown RH,Risby TH

    更新日期:2009-03-01 00:00:00

  • Tablets containing a cysteine protease, actinidine, reduce oral malodor: a crossover study.

    abstract::Tongue coating (TC) mainly consists of protein mostly from exfoliated epithelial cells. Until now, to reduce TC accumulation, only mechanical measures have been available, and the procedure involves unpleasant side effects, such as gagging reflex or carcinogenesis related to mechanical stimulation. We expected that pr...

    journal_title:Journal of breath research

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1752-7155/6/1/017107

    authors: Nohno K,Yamaga T,Kaneko N,Miyazaki H

    更新日期:2012-03-01 00:00:00

  • Prediction of blood:air and fat:air partition coefficients of volatile organic compounds for the interpretation of data in breath gas analysis.

    abstract::In this article, a database of blood:air and fat:air partition coefficients (λ b:a and λ f:a) is reported for estimating 1678 volatile organic compounds recently reported to appear in the volatilome of the healthy human. For this purpose, a quantitative structure-property relationship (QSPR) approach was applied and a...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/1/017103

    authors: Kramer C,Mochalski P,Unterkofler K,Agapiou A,Ruzsanyi V,Liedl KR

    更新日期:2016-01-27 00:00:00

  • Assessment of nanoparticles and metal exposure of airport workers using exhaled breath condensate.

    abstract::Aircraft engine exhaust increases the number concentration of nanoparticles (NP) in the surrounding environment. Health concerns related to NP raise the question of the exposure and health monitoring of airport workers. No biological monitoring study on this profession has been reported to date. The aim was to evaluat...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/3/036006

    authors: Marie-Desvergne C,Dubosson M,Touri L,Zimmermann E,Gaude-Môme M,Leclerc L,Durand C,Klerlein M,Molinari N,Vachier I,Chanez P,Mossuz VC

    更新日期:2016-07-13 00:00:00

  • Cluster analysis on breath print of newly diagnosed COPD patients: effects of therapy.

    abstract:BACKGROUND:Chronic obstructive pulmonary disease (COPD) is a highly heterogeneous disease and airflow limitation and symptoms only partially capture such heterogeneity. Since COPD is known to affect the production of volatile organic compounds (VOCs), we aimed to verify to which extent exhaled VOCs can characterize new...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aac273

    authors: Scarlata S,Finamore P,Santangelo S,Giannunzio G,Pennazza G,Grasso S,Santonico M,Incalzi RA

    更新日期:2018-06-08 00:00:00

  • Serum and exhaled breath condensate leptin levels in asthmatic and obesity children: a pilot study.

    abstract:BACKGROUND:Recent studies have highlighted the possible involvement of leptin in inflammation. The leptin receptor is also expressed by alveolar macrophages, T lymphocytes and bronchial epitelial cells, suggesting a possible role in the cascade of airway inflammation. OBJECTIVES:The aim of the study was to evaluate th...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7163/aa61c5

    authors: Bodini A,Tenero L,Sandri M,Maffeis C,Piazza M,Zanoni L,Peroni D,Boner A,Piacentini G

    更新日期:2017-09-27 00:00:00

  • Breathomics--exhaled volatile organic compound analysis to detect hepatic encephalopathy: a pilot study.

    abstract::The current diagnostic challenge with diagnosing hepatic encephalopathy (HE) is identifying those with minimal HE as opposed to the more clinically apparent covert/overt HE. Rifaximin, is an effective therapy but earlier identification and treatment of HE could prevent liver disease progression and hospitalization. Ou...

    journal_title:Journal of breath research

    pub_type: 杂志文章

    doi:10.1088/1752-7155/10/1/016012

    authors: Arasaradnam RP,McFarlane M,Ling K,Wurie S,O'Connell N,Nwokolo CU,Bardhan KD,Skinner J,Savage RS,Covington JA

    更新日期:2016-02-11 00:00:00