Abstract:
:Endodontically-treated teeth are prone to fracture due to loss of tooth structure and altered mechanical behaviors. The stability and rigidity of post-restored teeth, particularly in cases involving periodontal destruction, has not been adequately investigated. This study examined the influence of post material on teeth with simulated bone reduction by a multiparametric evaluation. Sixty extracted premolars of similar sizes were endodontically treated then divided into six groups. Each group was restored with one of the combinations of three posts (a glass-fiber, a prefabricated titanium post, and a cast post) and two simulated bone conditions (2 or 6 mm below crown margins). After crown restorations, they were loaded with a 100 N force then the displacements were examined by the digital-image-correlation technique. Marginal integrity on the buccal and lingual crown margins was examined before and after the thermocycling. Finally, the teeth were loaded until failure to examine the strength and fracture patterns. The digital-image-correlation measurements revealed that tooth deformation was related to the support conditions, especially for the fiber post groups. The cast post groups showed less altered marginal integrity after thermomechanical loading than the fiber and titanium post groups did. In the fracture test, the fiber-post/reduced-support group exhibited inferior fracture strength. The reduced support significantly affected fracture strength and incidence of repairable root fracture. The marginal integrity was not correlated with tooth deformation, since the tooth flexed at the crest of the simulated bone. The root fracture resistance was determined mainly by post materials but was concurrently affected by the support conditions.
journal_name
J Mech Behav Biomed Materauthors
Ni CW,Chang CH,Chen TY,Chuang SFdoi
10.1016/j.jmbbm.2010.10.012subject
Has Abstractpub_date
2011-04-01 00:00:00pages
322-30issue
3eissn
1751-6161issn
1878-0180pii
S1751-6161(10)00160-8journal_volume
4pub_type
杂志文章abstract::Many biomineralized organisms have evolved highly oriented nanostructures to perform specific functions. One key example is the abrasion-resistant rod-like microstructure found in the radular teeth of Chitons (Cryptochiton stelleri), a large mollusk. The teeth consist of a soft core and a hard shell that is abrasion r...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.03.026
更新日期:2015-08-01 00:00:00
abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.01.019
更新日期:2013-04-01 00:00:00
abstract:OBJECTIVES:Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing aware...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.10.021
更新日期:2019-02-01 00:00:00
abstract::Droplet processing technologies and many biological processes use disk-like or hemispherical shapes for construction or the design of surfaces. The ability to tune the characteristics and properties of a surface is important at the micro- and nano-scale. The influence of size on the mechanical properties is presently ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.07.014
更新日期:2012-12-01 00:00:00
abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2007.08.001
更新日期:2008-04-01 00:00:00
abstract::This study aimed at investigating articular cartilage rupture by investigating the response of healthy and degenerate cartilage through altering the osmotic swelling environment of surface-intact, cartilage-on-bone specimens. The osmotic environment in healthy and degenerate bovine cartilage was varied by soaking tiss...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.04.018
更新日期:2011-10-01 00:00:00
abstract::The tension-compression switch hypothesis for soft tissue proposes that when collagen fibres are compressed they do not contribute to the mechanical response which is then assumed to be the isotropic response of the extra-cellular matrix in which they are embedded. Such an assumption would seem reasonable. However, th...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103558
更新日期:2020-03-01 00:00:00
abstract::Tonometers are intended to determine the intraocular pressure (IOP) and the quality of corneal tissue. In contrast to the physiological state of stress of the cornea, tonometers induce non-physiological bending stress. Recently, the use of a single experiment to calibrate a set of corneal mechanical properties was sug...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.06.017
更新日期:2017-10-01 00:00:00
abstract::Modeling human body response to dynamic loading events and developing biofidelic human surrogate systems require accurate material properties over a range of loading rates for various human organ tissues. This work describes a technique for measuring the shear properties of soft biomaterials at high rates of strain (1...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.06.008
更新日期:2011-11-01 00:00:00
abstract::In the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and aniso...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.01.023
更新日期:2015-05-01 00:00:00
abstract::Constitutive models for biological tissue are typically formulated as a mixture of constituents and the overall response is then assembled by superposition or compatibility. This ensures the stress response of the biological tissue to be in the range of a given constitutive relationship, guaranteeing that at least one...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.04.037
更新日期:2019-08-01 00:00:00
abstract::The aim of this study was to develop a biodegradable three-dimensional-printed polylactide (PLA) cage for promoting bony fixation and an antibiotics-embedded poly(d,l)-lactide-co-glycolide (PLGA) nanofibrous membrane for infectious prophylaxis during treating the comminuted metaphyseal fracture in a rabbit femoral mod...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.05.002
更新日期:2017-08-01 00:00:00
abstract::A particular challenge in biomaterial development for treating orthopedic injuries stems from the need to balance bioactive design criteria with the mechanical and geometric constraints governed by the physiological wound environment. Such trade-offs are of particular importance in large craniofacial bone defects whic...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.03.032
更新日期:2016-08-01 00:00:00
abstract::Concussions occur 1.7 million times a year in North America, and account for approximately 75% of all traumatic brain injuries (TBI). Concussions usually cause transient symptoms but 10 to 20% of patients can have symptoms that persist longer than a month. The purpose of this research was to use reconstructions and fi...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.07.034
更新日期:2015-01-01 00:00:00
abstract::Advances in adhesive technologies have increased indications for the use of inlays. Decrease in the bonded interface integrity due to wear has been cited as the main cause of its failure. However, this process of interface degradation and the influence of inlay material on damage mechanism appear to be poorly understo...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103430
更新日期:2020-01-01 00:00:00
abstract::The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.07.002
更新日期:2014-10-01 00:00:00
abstract::Biological hydrogels, e.g. bacterial cellulose (BC) hydrogel, attracted increasing interest in recent decades since they show a good potential for biomedical engineering as replacements of real tissues thanks mainly to their good biocompatibility and fibrous structure. To select potential candidates for such applicati...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.021
更新日期:2016-06-01 00:00:00
abstract::This paper presents a numerical study on using vibration analysis to detect degradation in degrading polyesters. A numerical model of a degrading plate sample is considered. The plate is assumed to degrade following the typical behaviour of amorphous copolymers of polylactide and polyglycolide. Due to the well-known a...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.010
更新日期:2011-10-01 00:00:00
abstract::This paper presents a new approach to study the effects of temperature on the poro- elastic and viscoelastic behavior of articular cartilage. Biphasic solid-fluid mixture theory is applied to study the poro-mechanical behavior of articular cartilage in a fully saturated state. The balance of linear momentum, mass, and...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.11.023
更新日期:2018-02-01 00:00:00
abstract::In recent years, scaffolds produced in 3D printing technology have become more widespread tool due to providing more advantages than traditional methods in tissue engineering applications. In this research, it was aimed to produce patches for the treatment of tympanic membrane perforations which caused significant hea...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104219
更新日期:2021-02-01 00:00:00
abstract:OBJECTIVES:To investigate the elastic properties of human enamel using resonant ultrasound spectroscopy (RUS). METHODS:Six rectangular parallelepiped specimens were prepared from six human third molars. For all specimens, the theoretical resonant frequencies were calculated using the Rayleigh-Ritz method, knowing the ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.09.014
更新日期:2019-01-01 00:00:00
abstract::Imprecise knowledge on the composition-processing-microstructure-property correlation of titanium alloys combined with experimental data are used for developing rule based models for predicting the strength and elastic modulus of titanium alloys. The developed models are used for designing alloys suitable for orthoped...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.08.039
更新日期:2016-01-01 00:00:00
abstract::In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.02.009
更新日期:2012-06-01 00:00:00
abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.09.025
更新日期:2015-12-01 00:00:00
abstract:BACKGROUND AND AIMS:The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregna...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.07.005
更新日期:2014-11-01 00:00:00
abstract::Experimental and numerical investigation was conducted to study the micromechanics of oil palm empty fruit bunch fibres containing silica bodies. The finite viscoelastic-plastic material model called Parallel Rheological Network model was proposed, that fitted well with cyclic and stress relaxation tensile tests of th...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.04.043
更新日期:2016-09-01 00:00:00
abstract::A newly designed hydroxyapatite-polyurethane (HA-PU) composite scaffold was prepared by polymerizing glyceride of castor oil (GCO) with isophorone diisocyanate (IPDI) and HA as fillers. The aim of this study was to determine the effect of HA fillers on the mechanical properties and osteogenesis capacity of the composi...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.08.028
更新日期:2018-12-01 00:00:00
abstract::The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.10.005
更新日期:2009-08-01 00:00:00
abstract::The application of orthopaedic implants is associated with risks of bacterial infection and long-term antibiotic therapy. This problem has led to the study of implants with nano-textured surfaces as a method of inhibiting bacterial adhesion and reducing implant failure due to infection. In this research, various nano-...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.02.011
更新日期:2018-04-01 00:00:00