Nanoindentation of the insertional zones of human meniscal attachments into underlying bone.

Abstract:

:The fibrocartilagenous knee menisci are situated between the femoral condyles and tibia plateau and are primarily anchored to the tibia by means of four attachments at the anterior and posterior horns. Strong fixation of meniscal attachments to the tibial plateau provide resistance to extruding forces of the meniscal body, allowing the menisci to assist in load transmission from the femur to the tibia. Clinically, tears and ruptures of the meniscal attachments and insertion to bone are rare. While it has been suggested that the success of a meniscal replacement is dependent on several factors, one of which is the secure fixation and firm attachment of the replacement to the tibial plateau, little is known about the material properties of meniscal attachments and the transition in material properties from the meniscus to subchondral bone. The objective of this study was to use nanoindentation to investigate the transition from meniscal attachment into underlying subchondral bone through uncalcified and calcified fibrocartilage. Nanoindentation tests were performed on both the anterior and posterior meniscal insertions to measure the instantaneous elastic modulus and elastic modulus at infinite time. The elastic moduli were found to increase in a bi-linear fashion from the external ligamentous attachment to the subchondral bone. The elastic moduli for the anterior attachments were consistently larger than those for the matching posterior attachments at similar indentation locations. These results show that there is a gradient of stiffness from the superficial zones of the insertion close to the ligamentous attachment into the deeper zones of the bone. This information will be useful in the continued development of successful meniscal replacements and understanding of fixation of the replacements to the tibial plateau.

authors

Hauch KN,Oyen ML,Odegard GM,Haut Donahue TL

doi

10.1016/j.jmbbm.2008.10.005

subject

Has Abstract

pub_date

2009-08-01 00:00:00

pages

339-47

issue

4

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(08)00085-4

journal_volume

2

pub_type

杂志文章
  • Characterization of the mechanical behaviors and bioactivity of tetrapod ZnO whiskers reinforced bioactive glass/gelatin composite scaffolds.

    abstract::The purpose of this study is to construct bone tissue engineering scaffold with high porosity, good mechanical properties, and biological activities. Bioactive glass/gelatin composite scaffolds with different amounts of tetrapod zinc oxide whiskers were produced. The morphology, mechanical properties and in vitro bioa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.032

    authors: Guo W,Zhao F,Wang Y,Tang J,Chen X

    更新日期:2017-04-01 00:00:00

  • Effect of solvent/disinfectant ethanol on the micro-surface structure and properties of multiphase denture base polymers.

    abstract:AIM OF THE STUDY:The aim of this study was to evaluate the effect of solvent/disinfectant ethanol on the surface of denture base polymers. Changes in surface roughness, topography and some nanomechanical properties were assessed by SEM and nanoindentation plotted against different concentrations of ethanol on heat cure...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.007

    authors: Basavarajappa S,Al-Kheraif AA,ElSharawy M,Vallittu PK

    更新日期:2016-02-01 00:00:00

  • Mechanical characterization of bio composite films as a novel drug carrier platform for sustained release of 5-fluorouracil for colon cancer: Methodological investigation.

    abstract::In this study, we employed Pectin (PC) as a matrix that is hybridized with three different nucleobase (NB) units (cytosine, thymine, uracil) to generate pectin-nucleobase(PC-NB) biocomposite films stabilized through bio-multiple hydrogen bonds (BMHBs) as drug carrier for anticancer 5-Fluorouracil (5-FU). Prepared bioc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104266

    authors: Tamilselvi S,Kavitha R,Usharani M,Mumjitha M,Mohanapriya S,MohanaPriya S

    更新日期:2021-03-01 00:00:00

  • Tribology and hydrophobicity of a biocompatible GPTMS/PFPE coating on Ti6Al4V surfaces.

    abstract::Tribological properties of perfluoropolyether (PFPE) coated 3-glycidoxypropyltrimethoxy silane (GPTMS) SAMs (self-assembled monolayers) onto Ti6Al4V alloy substrate were studied using ball-on-disk experiments. GPTMS SAMs deposition onto a Ti6Al4V alloy surface was carried out using solution phase method. Ultra-thin la...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.06.016

    authors: Panjwani B,Sinha SK

    更新日期:2012-11-01 00:00:00

  • Thermal-stress analysis of ceramic laminate veneer restorations with different incisal preparations using micro-computed tomography-based 3D finite element models.

    abstract::Main objective of this study is to investigate the thermal behavior of ceramic laminate veneer restorations of the maxillary central incisor with different incisal preparations such as butt joint and palatinal chamfer using finite element method. In addition, it is also aimed to understand the effect of different ther...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.039

    authors: Celebi AT,Icer E,Eren MM,Baykasoglu C,Mugan A,Yildiz E

    更新日期:2017-11-01 00:00:00

  • Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution.

    abstract::This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars we...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103401

    authors: Dartora G,Rocha Pereira GK,Varella de Carvalho R,Zucuni CP,Valandro LF,Cesar PF,Caldas RA,Bacchi A

    更新日期:2019-12-01 00:00:00

  • Clamping soft biologic tissues for uniaxial tensile testing: A brief survey of current methods and development of a novel clamping mechanism.

    abstract::Biologic tissues are complex materials that come in many forms and perform a variety of functions. They vary widely in composition and mechanical properties, and determination of the mechanical properties of tissues is of interest to those trying to engineer tissues to restore missing function. In performing experimen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103503

    authors: Jiang M,Lawson ZT,Erel V,Pervere S,Nan T,Robbins AB,Feed AD,Moreno MR

    更新日期:2020-03-01 00:00:00

  • Mechanical evaluation by patient-specific finite element analyses demonstrates therapeutic effects for osteoporotic vertebrae.

    abstract::Osteoporosis can lead to bone compressive fractures in the lower lumbar vertebrae. In order to assess the recovery of vertebral strength during drug treatment for osteoporosis, it is necessary not only to measure the bone mass but also to perform patient-specific mechanical analyses, since the strength of osteoporotic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.03.001

    authors: Tawara D,Sakamoto J,Murakami H,Kawahara N,Oda J,Tomita K

    更新日期:2010-01-01 00:00:00

  • Collagen tissue treated with chitosan solution in H2O/CO2 mixtures: Influence of clathrates hydrates on the structure and mechanical properties.

    abstract::A mixture of water/carbon dioxide is a "green" perspective solvent from the viewpoint of biomedical applications. Clathrate hydrates are formed this solvent under certain conditions and a very interesting question is the impact of clathrates hydrates on the structure and properties of bovine pericardium, which is used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.11.015

    authors: Chaschin IS,Bakuleva NP,Grigoriev TE,Krasheninnikov SV,Nikitin LN

    更新日期:2017-03-01 00:00:00

  • Effects of compression on orientation of ligands in fluorescent complexes between hydroxyapatite with amino acids and their optical properties.

    abstract::This study aims to reveal the effects of pressure during cold isostatic pressing (CIP) on the microstructure and optical properties of fluorescent HAp complexes. Although the microsturucture-dependent properties of fluorescent HAp complexes have been reported to improve the antibacterial properties of photocatalyst co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.09.006

    authors: Morakul S,Otsuka Y,Nararya A,Tagaya M,Motozuka S,Ohnuma K,Miyashita Y,Mutoh Y

    更新日期:2018-12-01 00:00:00

  • Unusual effect evidenced at the investigations of the mechanical behavior of composite hydrogels under cyclic compression.

    abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.030

    authors: Gofman IV,Buyanov AL

    更新日期:2017-07-01 00:00:00

  • Nitinol stent design - understanding axial buckling.

    abstract::Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminatin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.029

    authors: McGrath DJ,O Brien B,Bruzzi M,McHugh PE

    更新日期:2014-12-01 00:00:00

  • Mechanical properties of Indonesian-made narrow dynamic compression plate.

    abstract::Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.04.018

    authors: Dewo P,van der Houwen EB,Sharma PK,Magetsari R,Bor TC,Vargas-Llona LD,van Horn JR,Busscher HJ,Verkerke GJ

    更新日期:2012-09-01 00:00:00

  • Friction of F-actin knots.

    abstract::We use the existing data of force-extension experiments on F-actin molecules tied into knots to compute a value of 0.15 for the static friction coefficient for contact between different parts of the same molecule with itself. This estimate for protein-protein friction is relevant for the stabilization of the 273 known...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.08.005

    authors: Kirchner HO,Neukirch S

    更新日期:2010-01-01 00:00:00

  • Monotonic and cyclic loading behavior of porous scaffolds made from poly(para-phenylene) for orthopedic applications.

    abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.004

    authors: Hoyt AJ,Yakacki CM,Fertig RS 3rd,Dana Carpenter R,Frick CP

    更新日期:2015-01-01 00:00:00

  • Strain rate influence on human cortical bone toughness: A comparative study of four paired anatomical sites.

    abstract::Bone fracture is a major health issue worldwide and consequently there have been extensive investigations into the fracture behavior of human cortical bone. However, the fracture properties of human cortical bone under fall-like loading conditions remains poorly documented. Further, most published research has been pe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.015

    authors: Gauthier R,Follet H,Langer M,Meille S,Chevalier J,Rongiéras F,Peyrin F,Mitton D

    更新日期:2017-07-01 00:00:00

  • Fibroblast populated collagen lattices exhibit opposite biophysical conditions by fibrin or hyaluronic acid supplementation.

    abstract::Fibrin and hyaluronic acid are important components of the provisional wound matrix. Through interactions with fibroblasts, they provide biophysical cues that regulate the viscoelastic properties of the extracellular matrix. To understand the roles of fibrin and hyaluronic acid in a collagenous environment, we used fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.042

    authors: Chopin-Doroteo M,Salgado-Curiel RM,Pérez-González J,Marín-Santibáñez BM,Krötzsch E

    更新日期:2018-06-01 00:00:00

  • New regime in the mechanical behavior of skin: strain-softening occurring before strain-hardening.

    abstract::We report linear and non-linear shear tests on rat skin, evidencing a strain-softening regime, from 1% to 50% strain, followed by a strong strain-hardening regime, leading to a 'deck chair-shaped' stress-strain curve. The strain-softening regime was never reported as such in the literature, possibly mistaken for the l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.021

    authors: Nicolle S,Decorps J,Fromy B,Palierne JF

    更新日期:2017-05-01 00:00:00

  • Graphite nanoplatelets-modified PLA/PCL: Effect of blend ratio and nanofiller localization on structure and properties.

    abstract::Structure and properties of poly(lactic acid) (PLA)/poly (ɛ-caprolactone) (PCL) influenced by graphite nanoplatelets (GNP) were studied in dependence on blend composition. Electron microscopy indicates predominant localization of GNP in PCL. GNP-induced changes in viscosity hinder refinement of PCL inclusions, support...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.028

    authors: Kelnar I,Kratochvíl J,Kaprálková L,Zhigunov A,Nevoralová M

    更新日期:2017-07-01 00:00:00

  • Elastic properties measurement of human enamel based on resonant ultrasound spectroscopy.

    abstract:OBJECTIVES:To investigate the elastic properties of human enamel using resonant ultrasound spectroscopy (RUS). METHODS:Six rectangular parallelepiped specimens were prepared from six human third molars. For all specimens, the theoretical resonant frequencies were calculated using the Rayleigh-Ritz method, knowing the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.09.014

    authors: Niu H,Fan F,Wang R,Zhang Q,Shen F,Ren P,Liu T,Fan Y,Laugier P

    更新日期:2019-01-01 00:00:00

  • Tissue mechanics of piled critical size biomimetic and biominerizable nanocomposites: Formation of bioreactor-induced stem cell gradients under perfusion and compression.

    abstract:BACKGROUND:Perfusion bioreactors are used to solve problems in critical size bone tissue engineering. Biominerizable and biocompatible nanocomposites are suitable scaffold materials for this purpose because they offer mineral components in organic carriers. Human adipose derived stem cells (ASCs) can potentially be use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.022

    authors: Baumgartner W,Welti M,Hild N,Hess SC,Stark WJ,Bürgisser GM,Giovanoli P,Buschmann J

    更新日期:2015-07-01 00:00:00

  • Environmental fatigue of superelastic NiTi wire with two surface finishes.

    abstract::Surface finish of NiTi is widely perceived to affect its biocompatibility and corrosion fatigue performance. The aim of this work was to find out, whether a carefully engineered surface oxide shows any beneficial effect over electropolished surface on the fatigue performance of superelastic NiTi wire mechanically cycl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104028

    authors: Racek J,Šittner P

    更新日期:2020-11-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Fabrication and characterization of poly(vinyl alcohol)-TiO2 nanocomposite films for orthopedic applications.

    abstract::Poly(vinyl alcohol) (PVA) is reinforced with TiO2 nanoparticles in order to enhance thermo-mechanical stabilities, surface characteristics and osteoblastic cell adhesion. PVA-TiO2 nanocomposite films with desirable mechanical, thermal and biocompatible properties are fabricated through solution casting method followed...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.009

    authors: Mohanapriya S,Mumjitha M,PurnaSai K,Raj V

    更新日期:2016-10-01 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.

    abstract::The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.026

    authors: Ridone P,Grage SL,Patkunarajah A,Battle AR,Ulrich AS,Martinac B

    更新日期:2018-03-01 00:00:00

  • Mechanical properties enhancement of self-cured PMMA reinforced with zirconia and boron nitride nanopowders for high-performance dental materials.

    abstract::We report on the mechanical properties regarding self-cured acrylic polymethyl methacrylate (PMMA) reinforced with hexagonal boron nitride (h-BN) and stabilized zirconia (8Y ZrO2) nanopowders. The nanocomposites were prepared by using both manual and ultrasonic mixing techniques. The fabricated specimens were subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103937

    authors: Alqahtani M

    更新日期:2020-10-01 00:00:00

  • Experimental study on dieless drawing of Nickel-Titanium alloy.

    abstract::The effect of a dieless drawing process on commercial grade Nickel-Titanium rods, of 5 mm diameter, was investigated by varying the established critical process parameters of temperature, cooling rate, drawing velocity, and heating/cooling velocity. The rods were successfully dieless drawn with a maximum steady state ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.013

    authors: Twohig E,Tiernan P,Tofail SA

    更新日期:2012-04-01 00:00:00

  • Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

    abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104253

    authors: Collins CJ,Yang B,Crenshaw TD,Ploeg HL

    更新日期:2021-03-01 00:00:00

  • Characterization of arterial flow mediated dilation via a physics-based model.

    abstract::In this paper, a physics-based mathematical model is developed to describe the transient behavior of the brachial artery during the Flow Mediated Dilation (FMD) test. The change of the artery's diameter was collected for 7 cases via in vivo, non-invasive ultrasound imaging. A theoretical model was developed to capture...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103756

    authors: Sidnawi B,Chen Z,Sehgal C,Wu Q

    更新日期:2020-07-01 00:00:00