A comparative EPR, infrared and Raman study of natural and deproteinated tooth enamel and dentin.

Abstract:

:The aim of the present work was to investigate how the native signal observed in the electron paramagnetic resonance (EPR) spectrum of tooth enamel and dentin is associated with the organic content of the two tissues. This was achieved by comparing the EPR native signal and the optical bands (Raman and infrared, IR) associated with organic components of tooth enamel and dentin, in natural and deproteinated samples. The main results were: (a) in natural samples, the organic optical bands are more intense in dentin than in enamel, in contrast with the EPR native signal which shows similar intensity in the two tissues; (b) after deproteination, the optical organic bands are completely suppressed in both dentin and enamel, while the EPR native signal is eliminated only in dentin. It is suggested that the IR and Raman organic bands are originated in the bulk of the organic matrix, while the paramagnetic centres associated with the EPR native signal are located in the organic-mineral interface.

journal_name

Phys Med Biol

authors

Fattibene P,Carosi A,De Coste V,Sacchetti A,Nucara A,Postorino P,Dore P

doi

10.1088/0031-9155/50/6/004

subject

Has Abstract

pub_date

2005-03-21 00:00:00

pages

1095-108

issue

6

eissn

0031-9155

issn

1361-6560

pii

S0031-9155(05)88229-6

journal_volume

50

pub_type

杂志文章
  • Evaluation of a ferrous benzoic xylenol orange transparent PVA cryogel radiochromic dosimeter.

    abstract::A stable cryogel dosimeter was prepared using ferrous benzoic xylenol orange (FBX) in a transparent poly-(vinyl alcohol) (PVA) cryogel matrix. Dose response was evaluated for different numbers of freeze-thaw cycles (FTCs), different concentrations of PVA, and ratios of water/dimethyl sulfoxide. Linear relationships be...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/7/1773

    authors: Eyadeh MM,Farrell TJ,Diamond KR

    更新日期:2014-04-07 00:00:00

  • Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

    abstract::Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the card...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/59/11/2813

    authors: Du Y,Bhattacharya M,Frey EC

    更新日期:2014-06-07 00:00:00

  • Calculation of electron beam dose distributions for arbitrarily shaped fields.

    abstract::A method for the calculation of absorbed dose distributions of arbitrarily shaped electron beams is presented. Isodose distributions and output factors of treatment fields can be predicted with good accuracy, without the need for any dose measurement in the actual field. A Gaussian pencil beam model is employed with t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/28/6/007

    authors: Bruinvis IA,Van Amstel A,Elevelt AJ,Van der Laarse R

    更新日期:1983-06-01 00:00:00

  • A multi-scale framework with unsupervised joint training of convolutional neural networks for pulmonary deformable image registration.

    abstract::To achieve accurate and fast deformable image registration (DIR) for pulmonary CT, we proposed a Multi-scale DIR framework with unsupervised Joint training of Convolutional Neural Network (MJ-CNN). MJ-CNN contains three models at multi-scale levels for a coarse-to-fine DIR to avoid being trapped in a local minimum. It...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab5da0

    authors: Jiang Z,Yin FF,Ge Y,Ren L

    更新日期:2020-01-13 00:00:00

  • A modified lead attenuation method to determine the fast neutron sensitivity kU of a photon dosemeter.

    abstract::Various lead attenuation techniques to determine the fast neutron sensitivity kU of a photon dosemeter are reviewed and a modified method is proposed to determine the kU value of a commercially available Geiger--Müller detector. The dependence on the 'effective' photon energy of the gamma-component of the mixed n--gam...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/24/4/005

    authors: Hough JH

    更新日期:1979-07-01 00:00:00

  • DAVID--a translucent multi-wire transmission ionization chamber for in vivo verification of IMRT and conformal irradiation techniques.

    abstract::Permanent in vivo verification of IMRT photon beam profiles by a radiation detector with spatial resolution, positioned on the radiation entrance side of the patient, has not been clinically available so far. In this work we present the DAVID system, which is able to perform this quality assurance measurement while th...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/51/5/013

    authors: Poppe B,Thieke C,Beyer D,Kollhoff R,Djouguela A,Rühmann A,Willborn KC,Harder D

    更新日期:2006-03-07 00:00:00

  • Single and multiple cross sections for ionizing processes of biological molecules by protons and alpha-particle impact: a classical Monte Carlo approach.

    abstract::A classical trajectory model has been used to predict total cross sections of single and double ionizing processes (including capture processes) for several ion-biological molecule collisional systems in the intermediate and high energy range. In this work, the systems studied are water, adenine or cytosine targets io...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/4/N03

    authors: Abbas I,Champion C,Zarour B,Lasri B,Hanssen J

    更新日期:2008-02-21 00:00:00

  • Influence of vascular normalization on interstitial flow and delivery of liposomes in tumors.

    abstract::Elevated interstitial fluid pressure is one of the barriers of drug delivery in solid tumors. Recent studies have shown that normalization of tumor vasculature by anti-angiogenic factors may improve the delivery of conventional cytotoxic drugs, possibly by increasing blood flow, decreasing interstitial fluid pressure,...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/4/1477

    authors: Ozturk D,Yonucu S,Yilmaz D,Unlu MB

    更新日期:2015-02-21 00:00:00

  • Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurements.

    abstract::An open-ended coaxial probe is often used for investigating the dielectric properties of biological tissues. The present study indicates that in addition to the probe size, the penetration of the electromagnetic (EM) fields of an open-ended coaxial probe in contact with the skin is dependent on the applied frequency b...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/7/404

    authors: Alanen E,Lahtinen T,Nuutinen J

    更新日期:1999-07-01 00:00:00

  • Layer-specific ultrasound elastography using a multi-layered shear wave dispersion model for assessing the viscoelastic properties.

    abstract::Mechanical properties of biological tissues are significant biomarkers for diagnosing various diseases. Assessing the viscoelastic properties of multi-layer tissues has remained challenging for a long time. Some shear wave models have been proposed to estimate thin-layer tissues' viscoelasticity recently. However, the...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abca04

    authors: Lu G,Li R,Qian X,Chen R,Jiang L,Chen Z,Shung KK,Humayun MS,Zhou Q

    更新日期:2020-11-12 00:00:00

  • Systematic variations in polymer gel dosimeter calibration due to container influence and deviations from water equivalence.

    abstract::There are a number of gel dosimeter calibration methods in contemporary usage. The present study is a detailed Monte Carlo investigation into the accuracy of several calibration techniques. Results show that for most arrangements the dose to gel accurately reflects the dose to water, with the most accurate method invo...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/52/13/022

    authors: Taylor ML,Franich RD,Johnston PN,Millar RM,Trapp JV

    更新日期:2007-07-07 00:00:00

  • A theoretical model for respiratory motion artifacts in free-breathing CT scans.

    abstract::Successful radiotherapy treatment depends heavily upon the accuracy of patient geometry captured during treatment simulation using computed tomography (CT) scans. Radiotherapy patients are often scanned under free breathing, and respiratory motion can cause severe artifacts in CT scans, including shortening, elongatio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/3/018

    authors: Lewis JH,Jiang SB

    更新日期:2009-02-07 00:00:00

  • High resolution bone mineral densitometry with a gamma camera.

    abstract::A technique is described by which the regional distribution of bone mineral can be determined in bone samples from small animals. The technique employs an Anger camera interfaced to a medical computer. High resolution (less than 1 mm) imaging is possible by producing magnified images of the bone samples. Regional dens...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/1/003

    authors: LeBlanc A,Evans H,Jhingran S,Johnson P

    更新日期:1984-01-01 00:00:00

  • Investigation of real tissue water equivalent path lengths using an efficient dose extinction method.

    abstract::For proton therapy, an accurate conversion of CT HU to relative stopping power (RSP) is essential. Validation of the conversion based on real tissue samples is more direct than the current practice solely based on tissue substitutes and can potentially address variations over the population. Based on a novel dose exti...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa782c

    authors: Zhang R,Baer E,Jee KW,Sharp GC,Flanz J,Lu HM

    更新日期:2017-06-23 00:00:00

  • Characterization of 3D joint space morphology using an electrostatic model (with application to osteoarthritis).

    abstract::Joint space morphology can be indicative of the risk, presence, progression, and/or treatment response of disease or trauma. We describe a novel methodology of characterizing joint space morphology in high-resolution 3D images (e.g. cone-beam CT (CBCT)) using a model based on elementary electrostatics that overcomes a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/3/947

    authors: Cao Q,Thawait G,Gang GJ,Zbijewski W,Reigel T,Brown T,Corner B,Demehri S,Siewerdsen JH

    更新日期:2015-02-07 00:00:00

  • Performance comparison of depth-encoding detectors based on dual-ended readout and different SiPMs for high-resolution PET applications.

    abstract::Silicon photomultipliers (SiPMs) are widely used in positron emission tomography (PET), however, SiPMs from different vendors vary in their performance characteristics. In addition, the specifications provided by the manufacturers are measured under different operating conditions and using different test setups, makin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab1c37

    authors: Du J,Bai X,Cherry SR

    更新日期:2019-08-07 00:00:00

  • A feasibility study of the use of fluorescence bronchoscopy for localization of small lung tumours.

    abstract::The possible use of fluorescence bronchoscopy for localization of bronchogenic tumours at the carcinoma in situ stage has been investigated. The target lesion is 80 micrometer thick with a mass of 250 microgram, containing 250 pg of haematoporphyrin derivative. The injected haematoporphyrin-derivative is preferentiall...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/22/5/014

    authors: Profio AE,Doiron DR

    更新日期:1977-09-01 00:00:00

  • Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    abstract::Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registratio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa62c5

    authors: Uneri A,De Silva T,Goerres J,Jacobson MW,Ketcha MD,Reaungamornrat S,Kleinszig G,Vogt S,Khanna AJ,Osgood GM,Wolinsky JP,Siewerdsen JH

    更新日期:2017-04-21 00:00:00

  • Segmented attenuation correction using artificial neural networks in positron tomography.

    abstract::The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/10/024

    authors: Yu SK,Nahmias C

    更新日期:1996-10-01 00:00:00

  • On MEG forward modelling using multipolar expansions.

    abstract::Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional par...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/47/4/301

    authors: Jerbi K,Mosher JC,Baillet S,Leahy RM

    更新日期:2002-02-21 00:00:00

  • Extension of the NCAT phantom for the investigation of intra-fraction respiratory motion in IMRT using 4D Monte Carlo.

    abstract::The purpose of this work was to create a computational platform for studying motion in intensity modulated radiotherapy (IMRT). Specifically, the non-uniform rational B-spline (NURB) cardiac and torso (NCAT) phantom was modified for use in a four-dimensional Monte Carlo (4D-MC) simulation system to investigate the eff...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/5/014

    authors: McGurk R,Seco J,Riboldi M,Wolfgang J,Segars P,Paganetti H

    更新日期:2010-03-07 00:00:00

  • Array detection for speckle reduction in optical coherence microscopy.

    abstract::This paper introduces a spatial-diversity method for speckle suppression in optical coherence microscopy. The method is based on combining interference signals from an array of detectors placed in the back focal plane of the objective lens, such that elements receive light backscattered from the sample volume at diffe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/42/7/015

    authors: Schmitt JM

    更新日期:1997-07-01 00:00:00

  • Simultaneous optimization of RBE-weighted dose and nanometric ionization distributions in treatment planning with carbon ions.

    abstract::Inverse treatment planning in intensity modulated particle therapy (IMPT) with scanned carbon-ion beams is currently based on the optimization of RBE-weighted dose to satisfy requirements of target coverage and limited toxicity to organs-at-risk (OARs) and healthy tissues. There are many feasible IMPT plans that meet ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aaf400

    authors: Burigo LN,Ramos-Méndez J,Bangert M,Schulte RW,Faddegon B

    更新日期:2019-01-04 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.

    abstract::The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for prompt gamma imaging (PGI) as a means of providing in vivo verification of the delivered proton radiotherapy beams. A water phantom was i...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/18/7085

    authors: Polf JC,Avery S,Mackin DS,Beddar S

    更新日期:2015-09-21 00:00:00

  • A low cost method for hard x-ray grating interferometry.

    abstract::Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critica...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/23/8266

    authors: Du Y,Lei Y,Liu X,Huang J,Zhao Z,Guo J,Li J,Niu H

    更新日期:2016-12-07 00:00:00

  • An automated, fast and accurate registration method to link stranded seeds in permanent prostate implants.

    abstract::The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed moveme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/N391

    authors: Westendorp H,Nuver TT,Moerland MA,Minken AW

    更新日期:2015-10-21 00:00:00

  • Meshless reconstruction technique for digital tomosynthesis.

    abstract::A novel meshless reconstruction algorithm for digital tomosynthesis (DT) is presented and assessed against experimental data. The algorithm does not require a three-dimensional grid or mesh allocation and performs a slice-by-slice reconstruction where each slice position can be chosen at runtime. The methodology is ba...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab7685

    authors: Soloviev VY,Renforth KL,Dirckx CJ,Wells SG

    更新日期:2020-04-20 00:00:00

  • Characterization of enzymatically induced degradation of articular cartilage using high frequency ultrasound.

    abstract::Ultrasound may provide a quantitative technique for the characterization of cartilage changes typical of early osteoarthrosis. In this study, specific changes in bovine articular cartilage were induced using collagenase and chondroitinase ABC, enzymes that selectively degrade collagen fibril network and digest proteog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/44/11/303

    authors: Töyräs J,Rieppo J,Nieminen MT,Helminen HJ,Jurvelin JS

    更新日期:1999-11-01 00:00:00

  • Directional x-ray dark-field imaging.

    abstract::We introduce a novel x-ray imaging approach that yields information about the local texture of structures smaller than the image pixel resolution inside an object. The approach is based on a recently developed x-ray dark-field imaging technique, using scattering from sub-micron structures in the sample. We show that t...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/55/12/004

    authors: Jensen TH,Bech M,Bunk O,Donath T,David C,Feidenhans'l R,Pfeiffer F

    更新日期:2010-06-21 00:00:00