"Sandwich" enzyme immunoassay for serum ferritin with polypropylene test tubes as the solid phase.

Abstract:

:A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are developed during constant rotation of the tubes. The assay requires 20 microL of serum per assay and takes less than 3 h. The standard curve is linear between 0 and 400 micrograms of serum ferritin per liter. Analytical recoveries of various amounts of standard added to a serum sample ranged from 92 to 98.6%. The sensitivity is 2 micrograms/L, which translates to 0.4 ng per assay tube. Within-run CV ranges from 1.6 to 5.4% and between-run from 4.2 to 7.8% according to the ferritin concentration. Results by competitive radioimmunoassay correlated well (r = 0.98). No "hook effect" was observed for concentrations up to 13 mg/L. The reference interval is 40-240 micrograms/L for men, 8-100 micrograms/L for women.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Revenant MC

subject

Has Abstract

pub_date

1983-04-01 00:00:00

pages

681-3

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

29

pub_type

杂志文章
  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Analytical goals developed from the inherent error of medical tests.

    abstract::Biological variation is inherent in all medical tests and is a major source of error in clinical test interpretation. We use inherent test error due to biological variability as the touchstone by which to validate the clinical acceptability of analytical goals. Analytical goals should consist of sets of complementary ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ross JW,Fraser MD

    更新日期:1993-07-01 00:00:00

  • A homogeneous method for genotyping with fluorescence polarization.

    abstract::We combined the amplification refractory mutation system (ARMS) and fluorescence polarization (FP) to give a homogeneous genomic DNA genotype analysis method. Oligonucleotide probes labeled with the fluorescein dyes fluorescein isothiocyanate and 5-([4,6-dichlorotriazin-2-yl]amino)fluorescein and the rhodamine dye 6-c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibson NJ,Gillard HL,Whitcombe D,Ferrie RM,Newton CR,Little S

    更新日期:1997-08-01 00:00:00

  • Longitudinal concentrations of vitamin B(12) and vitamin B(12)-binding proteins during uncomplicated pregnancy.

    abstract:BACKGROUND:Because reference values for vitamin B(12) concentrations and vitamin B(12)-binding capacities for pregnant women have not been established, the reference values for nonpregnant women are often applied to assess vitamin B(12) status. The aim of the present study was to describe ranges of biochemical indices ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koebnick C,Heins UA,Dagnelie PC,Wickramasinghe SN,Ratnayaka ID,Hothorn T,Pfahlberg AB,Hoffmann I,Lindemans J,Leitzmann C

    更新日期:2002-06-01 00:00:00

  • Determination of serum 17 alpha-hydroxyprogesterone by liquid chromatography.

    abstract::17 alpha-Hydroxyprogesterone, cortisol, and 11-deoxycortisol were extracted with methylene chloride, separated by liquid chromatography, identified by their retention times, and quantitated by monitoring the absorbance at 254 nm. The method is specific and sensitive to as little as 2.5 ng of 17 alpha-hydroxyprogestero...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Canalis E,Caldarella AM,Reardon GE

    更新日期:1981-07-01 00:00:00

  • Rapid, simple, and sensitive immunoagglutination assay with SiO2 particles and quartz crystal microbalance for quantifying Schistosoma japonicum antibodies.

    abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071555

    authors: Wang H,Zhang Y,Yan B,Liu L,Wang S,Shen G,Yu R

    更新日期:2006-11-01 00:00:00

  • Is succinyldicholine the substrate of choice for the measurement of cholinesterase activity?

    abstract::We have developed a succinyldicholine-based assay for serum cholinesterase (EC 3.1.1.8) to help establish whether patients with suspected sensitivity to drugs of this type have enzyme abnormalities that cannot be detected by conventional laboratory techniques. Although the method discriminates between cholinesterase a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Faye S,Evans RT

    更新日期:1986-08-01 00:00:00

  • Real-time PCR technology for cancer diagnostics.

    abstract:BACKGROUND:Advances in the biological sciences and technology are providing molecular targets for diagnosing and treating cancer. Current classifications in surgical pathology for staging malignancies are based primarily on anatomic features (e.g., tumor-node-metastasis) and histopathology (e.g., grade). Microarrays to...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bernard PS,Wittwer CT

    更新日期:2002-08-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Population-based study of repeat laboratory testing.

    abstract:BACKGROUND:Test repetition could be a readily modifiable component of laboratory utilization. Laboratory test repetition has not been rigorously studied at a population-based level. Our objective was to determine the prevalence of, and charges associated with, repetition of eight common laboratory tests. METHODS:We pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.021220

    authors: van Walraven C,Raymond M

    更新日期:2003-12-01 00:00:00

  • Radioassay for cobalamin (vitamin B12) requiring no pretreatment of serum.

    abstract::We describe a radioassay for cobalamin (vitamin B12) in human serum or plasma that requires no boiling or other pretreatment of the sample. Normal chicken serum covalently coupled to magnetizable particles is used as the binding agent. The assay is performed at pH 12.9, at which pH all cobalamin in human serum is rele...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Houts TM,Carney JA

    更新日期:1981-02-01 00:00:00

  • Soluble CD146 Is a Novel Marker of Systemic Congestion in Heart Failure Patients: An Experimental Mechanistic and Transcardiac Clinical Study.

    abstract:BACKGROUND:Soluble CD146 (sCD146), is an endothelial marker with similar diagnostic power as natriuretic peptides in decompensated heart failure (HF). While natriuretic peptides are released by the failing heart, sCD146 may be released by veins in response to stretch induced by systemic congestion in HF. This study inv...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2016.260471

    authors: Arrigo M,Truong QA,Onat D,Szymonifka J,Gayat E,Tolppanen H,Sadoune M,Demmer RT,Wong KY,Launay JM,Samuel JL,Cohen-Solal A,Januzzi JL Jr,Singh JP,Colombo PC,Mebazaa A

    更新日期:2017-01-01 00:00:00

  • Low HDL Cholesterol and High Risk of Autoimmune Disease: Two Population-Based Cohort Studies Including 117341 Individuals.

    abstract:BACKGROUND:HDL is quantitatively the most important lipoprotein in most species and mechanistic evidence points toward a role for HDL in normal immune function. We tested the hypothesis that concentrations of HDL cholesterol are associated with risk of autoimmune disease. METHODS:From 2 studies of the general populati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.299636

    authors: Madsen CM,Varbo A,Nordestgaard BG

    更新日期:2019-05-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00

  • Lipoprotein lipids in women with androgen excess: independent associations with increased insulin and androgen.

    abstract::Concentrations of triglycerides are increased and concentrations of high-density lipoprotein (HDL) cholesterol are low in women with hyperandrogenism. These alterations could be related to excessive androgen or estrogen, to hyperinsulinism, or to a combination of these abnormalities. We examined their independent infl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wild RA,Applebaum-Bowden D,Demers LM,Bartholomew M,Landis JR,Hazzard WR,Santen RJ

    更新日期:1990-02-01 00:00:00

  • Monitoring cyclosporine in liver-transplant recipients: effects of clinical status on the performance of two monoclonal antibody-based methods.

    abstract::The characteristics of the Abbott selective fluorescence polarization immunoassay for cyclosporine in whole blood (TDXSP) were compared with the Incstar radioimmunoassay by using kit standards (INCSP) or TDXSP standards (INCTDX) with samples from adult (48) and pediatric (24) liver-transplant recipients and a further ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tredger JM,Gonde CE,Williams R

    更新日期:1992-01-01 00:00:00

  • A clinical chemistry analyzer evaluated by NCCLS guidelines for use in a military field laboratory unit.

    abstract::In a previous comparison study of "dry chemistry" desktop analyzers, the ChemPro 1000 (Arden Medical Systems) was one of several instruments found suitable for field use. We have now evaluated the linearity, accuracy, and precision of the ChemPro 1000, according to NCCLS Document EP 10-P. We also compared results with...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sullinger J,Garrett PE

    更新日期:1989-11-01 00:00:00

  • Evaluation of pteroylglutamic acid and n-5-methyltetrahydrofolic acid reference standards in a new "No-Boil" radioassay for serum folate.

    abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Theobald RA,Batchelder M,Sturgeon MF

    更新日期:1981-04-01 00:00:00

  • Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

    abstract:BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2012.195784

    authors: Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

    更新日期:2013-01-01 00:00:00

  • Chromogenic ionophore-based methods for spectrophotometric assay of sodium and potassium in serum and plasma.

    abstract::We report spectrophotometric methods for quantifying sodium and potassium in serum and plasma without sample pretreatment or solvent-extraction steps. The methods are based on novel chromogenic ionophores characterized by molecular structures highly preorganized for binding, which result in exceptionally high sensitiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kumar A,Chapoteau E,Czech BP,Gebauer CR,Chimenti MZ,Raimondo O

    更新日期:1988-09-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol.

    abstract::We evaluated the performance of two homogeneous assays for quantifying HDL cholesterol (HDL-C) and compared them with the phosphotungstic acid (PTA)/ MgCl2 assay. Both homogeneous HDL-C assays were precise, having a within-run CV of < 1.20% and a between-run CV of < 4.07%. The HDL-C values (y) measured by the two homo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huang YC,Kao JT,Tsai KS

    更新日期:1997-06-01 00:00:00

  • Use of the laboratory in prediction of outcome in the high-risk newborn.

    abstract::This paper reviews our ability to predict survival and neurodevelopmental outcome in the newborn period. Traditionally, prognosis is based on individual risk factors or disease states. The laboratory plays an important role in diagnosing some of these. For example, prenatal and newborn screening are important in the d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Synnes AR

    更新日期:1997-01-01 00:00:00

  • Single-Stranded DNA Library Preparation Preferentially Enriches Short Maternal DNA in Maternal Plasma.

    abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268656

    authors: Vong JSL,Tsang JCH,Jiang P,Lee WS,Leung TY,Chan KCA,Chiu RWK,Lo YMD

    更新日期:2017-05-01 00:00:00

  • Use of proximity ligation to screen for inhibitors of interactions between vascular endothelial growth factor A and its receptors.

    abstract:BACKGROUND:Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. METHODS:We used sensitive, miniaturized proximity ligation assays (...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.099424

    authors: Gustafsdottir SM,Wennström S,Fredriksson S,Schallmeiner E,Hamilton AD,Sebti SM,Landegren U

    更新日期:2008-07-01 00:00:00

  • Modified pentamer formation assay for measurement of tacrolimus and its active metabolites: comparison with liquid chromatography-tandem mass spectrometry and microparticle enzyme-linked immunoassay (MEIA-II).

    abstract::A modified pentamer formation assay (PFA) for quantification of tacrolimus and active metabolites after extraction from whole blood is described. The lower limit of detection was 2 microg/L. Intraassay precision (CV) was 5.7-13.7%, and the interassay CV was 6. 1-14.9%. Tacrolimus trough concentrations in 104 whole blo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Armstrong VW,Schuetz E,Zhang Q,Groothuisen S,Scholz C,Shipkova M,Aboleneen H,Oellerich M

    更新日期:1998-12-01 00:00:00

  • Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring: an overview.

    abstract::Even though significant progress has been made in the development of electrodes for the in vivo detection of catecholamines, oxygen, and various cations, there has been little research on the feasibility of continuously monitoring drugs in whole blood by electrochemical sensing devices. Electroanalytical problems asso...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pinkerton TC,Lawson BL

    更新日期:1982-09-01 00:00:00

  • High-dose alpha-tocopherol therapy does not affect HDL subfractions in patients with coronary artery disease on statin therapy.

    abstract:BACKGROUND:Subfractions of HDL, particularly large HDL (HDL2), are inversely correlated with the severity of coronary artery disease (CAD). alpha-Tocopherol (AT) is the main lipid-soluble antioxidant in plasma. Results of a previous small study (n = 44) suggested that either a combination of an antioxidant cocktail [80...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.078865

    authors: Singh U,Otvos J,Dasgupta A,de Lemos JA,Devaraj S,Jialal I

    更新日期:2007-03-01 00:00:00

  • Determination of beta 2-microglobulin in human urine and serum by latex immunoassay.

    abstract::This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bernard AM,Vyskocil A,Lauwerys RR

    更新日期:1981-06-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00