Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

Abstract:

BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and calculated as p2PSA/fPSA × √tPSA, was evaluated in a multicenter study for detecting PCa. METHODS:A total of 1362 patients from 4 different study sites who had tPSA values of 1.6-8.0 μg/L (668 patients with PCa, 694 without PCa) underwent ≥10 core biopsies. Serum concentrations of tPSA, fPSA (both calibrated against a WHO reference material), and p2PSA were measured on Access2 or DxI800 analyzers (Beckman Coulter). RESULTS:The percentage ratio of p2PSA to fPSA (%p2PSA) and Phi were significantly higher in all PCa subcohorts (positive initial or repeat biopsy result or negative digital rectal examination) (P < 0.0001) compared with patients without PCa. Phi had the largest area under the ROC curve (AUC) (AUC = 0.74) and provided significantly better clinical performance for predicting PCa compared with %p2PSA (AUC = 0.72, P = 0.018), p2PSA (AUC = 0.63, P < 0.0001), %fPSA (AUC = 0.61) or tPSA (AUC = 0.56). Significantly higher median values of Phi were observed for patients with a Gleason score ≥7 (Phi = 60) compared with a Gleason score <7 (Phi = 53; P = 0.0018). The proportion of aggressive PCa (Gleason score ≥7) increased with the Phi score. CONCLUSIONS:The results of this multicenter study show that Phi, compared with tPSA or %fPSA, demonstrated superior clinical performance in detecting PCa at tPSA 1.6-8.0 μg/L (i.e., approximately 2-10 μg/L in traditional calibration) and is better able to detect aggressive PCa.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

doi

10.1373/clinchem.2012.195784

subject

Has Abstract

pub_date

2013-01-01 00:00:00

pages

306-14

issue

1

eissn

0009-9147

issn

1530-8561

pii

clinchem.2012.195784

journal_volume

59

pub_type

杂志文章,多中心研究
  • Immunofluorometric demonstration and quantification of placental protein 5 in the absence of pregnancy.

    abstract::This time-resolved immunofluorometric assay (IFMA) developed for measurement of placental protein 5 (PP5) involves two antibodies: a monoclonal anti-PP5 antibody attached to a solid phase and an europium(III) chelate-labeled polyclonal anti-PP5 antibody as a tracer. The measuring range is 0.05-100 micrograms/L and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bützow R,Alfthan H,Stenman UH,Suikkari AM,Bohn H,Seppälä M

    更新日期:1988-08-01 00:00:00

  • Determination of 5-hydroxytryptophan in plasma by high-performance liquid chromatography and fluorometric detection after phthaldialdehyde reaction.

    abstract::We describe the sensitive and precise determination 5-hydroxytryptophan in plasma from patients treated with this compound. The method is based on solvent extraction of plasma, high-performance liquid chromatography and continuous fluorometric detection after reaction with phthaldialdehyde in strong acid. The combined...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Enbaek F,Magnussen I

    更新日期:1978-02-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Quality assurance, accreditation, and certification: needs and possibilities.

    abstract::Demonstrable quality of laboratory services entails two parts. First, one needs a quality policy statement, identification of user needs, choice of measurement procedures, reference measurement system to provide traceability, control materials, and proficiency testing with materials having reference-measurement-assign...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Dybkaer R

    更新日期:1994-07-01 00:00:00

  • Lipoprotein(a) and cardiovascular disease in ethnic Chinese: the Chin-Shan Community Cardiovascular Cohort Study.

    abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090969

    authors: Chien KL,Hsu HC,Su TC,Sung FC,Chen MF,Lee YT

    更新日期:2008-02-01 00:00:00

  • Activation of alanine aminotransferase in serum by pyridoxal phosphate.

    abstract::Alanine aminotransferase activity in serum increases significantly when serum is incubated with pyridoxal phosphate. The increase depends on the L-alanine concentration in the final assay mixture, being greatest at 800 mmol/liter. Preincubation of 22 normal sera, in a 10:1 ratio with an 8.09 mmol/liter pyridoxal phosp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lustig V

    更新日期:1977-02-01 00:00:00

  • Direct determination of sulfate conjugates of 17-oxosteroids in urine by liquid chromatography.

    abstract::We describe a new liquid-chromatographic method with fluorescence detection for direct simultaneous determination of four urinary sulfate conjugates of 17-oxosteroids (17OS), without use of solvolysis or enzymatic hydrolysis. The 17OS sulfates in urine samples are extracted with benzene as ion pairs in the presence of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nishikaze O,Iwata J

    更新日期:1986-05-01 00:00:00

  • Flow-cytometric determination of high-density-lipoprotein binding sites on human leukocytes.

    abstract::In this method, leukocytes were isolated from 6 mL of EDTA-blood by density-gradient centrifugation and subsequently incubated with rhodamine isothiocyanate (RITC)-conjugated high-density lipoproteins (HDL). The receptor-bound conjugate particles were determined by fluorescent flow cytometry and compared with 125I-lab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schmitz G,Wulf G,Brüning T,Assmann G

    更新日期:1987-12-01 00:00:00

  • Kinetic centrifugal analyzer and manual determination of serum urea nitrogen, with use of o-phthaldialdehyde reagent.

    abstract::o-Phthaldialdehdye reagent was used in assaying urea with a miniature centrifugal analyzer. Seventeen samples can be assayed kinetically in 2 min at a current cost of less than a penny per test. The reaction is initiated in the instrument upon simultaneous mixing of the o-phthaldialdehyde reagent containing 10 microli...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levinson SS

    更新日期:1978-12-01 00:00:00

  • The Longer, the Better? An Empirical Study of the Extent and Mechanisms of Attenuating Biomarker Associations in Cardiovascular Patient Cohorts.

    abstract:BACKGROUND:Identifying novel risk markers in cardiovascular patients remains a research priority. Longer follow-up generally is considered favorable in such studies, but associations of interest may become attenuated with increasing follow-up. This issue has not been adequately addressed in the context of patient cohor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.263202

    authors: Breitling LP,Mons U,Hahmann H,Koenig W,Rothenbacher D,Brenner H

    更新日期:2017-03-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • Diagnosis of 5α-reductase 2 deficiency: is measurement of dihydrotestosterone essential?

    abstract:BACKGROUND:5α-Reductase 2 deficiency (5ARD) is a known cause of 46,XY disorders of sex development (DSD). Traditionally, the diagnosis relies on dihydrotestosterone (DHT) measurement, but the results are often equivocal, potentially leading to misdiagnosis. We reviewed alternative approaches for diagnosis of 5ARD. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.196501

    authors: Chan AO,But BW,Lee CY,Lam YY,Ng KL,Tung JY,Kwan EY,Chan YK,Tsui TK,Lam AL,Tse WY,Cheung PT,Shek CC

    更新日期:2013-05-01 00:00:00

  • 25-Hydroxyvitamin D and Risk of Osteoporotic Fractures: Mendelian Randomization Analysis in 2 Large Population-Based Cohorts.

    abstract:BACKGROUND:Whether low plasma 25-hydroxyvitamin D concentrations cause osteoporotic fractures is unclear. We tested the hypothesis that low plasma 25-hydroxyvitamin D concentrations are associated with increased risk of osteoporotic fractures using a Mendelian randomization analysis. METHODS:We genotyped 116 335 rando...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa049

    authors: Çolak Y,Afzal S,Nordestgaard BG

    更新日期:2020-05-01 00:00:00

  • Improved separation of creatine kinase cardiac isoenzyme in serum by batch fractionation.

    abstract::I describe a simple, single-tube batch fractionation procedure for separating MM and MB isoenzymes of creatine kinase on a macroporous strong anion exchanger (AG MP-1, Bio-Rad Laboratories). The isoenzymes can be separated in less than 3 min, with a resulting dilution of the serum with no more than an equal volume of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morin LG

    更新日期:1976-01-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • Combi scheme: new combined internal/external quality-assessment scheme in The Netherlands.

    abstract::The Dutch Foundation for Quality Assessment in Clinical Chemistry (SKZL) is the professional organization that conducts external quality-assessment schemes in The Netherlands. However, such schemes in fact assess the performance of the internal quality-control systems of the participating laboratories. In this paper w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steigstra H,Jansen RT,Baadenhuijsen H

    更新日期:1991-07-01 00:00:00

  • Immobilization of immunoglobulins onto surface-treated and untreated polystyrene beads for radioimmunoassays.

    abstract::The immunoreactivity of anti-triiodothyronine (anti-T3) IgG, pretreated at acidic pH and adsorbed onto polystyrene beads, was significantly greater than that determined for native anti-T3 IgG immobilized at optimum pH 3.5. Acidic-pH-pretreated IgG, adsorbed at pH 7.0 onto ethanol-treated beads, had less immunoreactivi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kakabakos SE,Livanlou E,Evangelatos GP,Ithakissios DS

    更新日期:1990-03-01 00:00:00

  • Energy-dispersive x-ray fluorescence spectroscopy and inductively coupled plasma emission spectrometry evaluated for multielement analysis in complex biological matrices.

    abstract::Energy-dispersive x-ray spectroscopy and inductively coupled plasma emission spectrometry were evaluated as methods for routine multielement analysis of biological material. Standard samples included Standard Reference Materials (National Bureau of Standards), compounded mixtures, and supplements that provided a wide ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Irons RD,Schenk EA,Giauque RD

    更新日期:1976-12-01 00:00:00

  • Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

    abstract::We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mahoney JJ,Wong RJ,Van Kessel AL

    更新日期:1993-05-01 00:00:00

  • Mass concentration and activity concentration of creatine kinase isoenzyme MB compared in serum after acute myocardial infarction.

    abstract::We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,De Mol AM,De Buyzere ML,De Scheerder IK,Wieme RJ

    更新日期:1990-01-01 00:00:00

  • HPLC for simultaneous quantification of total ceramide, glucosylceramide, and ceramide trihexoside concentrations in plasma.

    abstract:BACKGROUND:Simple, reproducible assays are needed for the quantification of sphingolipids, ceramide (Cer), and sphingoid bases. We developed an HPLC method for simultaneous quantification of total plasma concentrations of Cer, glucosylceramide (GlcCer), and ceramide trihexoside (CTH). METHODS:After addition of sphinga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.079012

    authors: Groener JE,Poorthuis BJ,Kuiper S,Helmond MT,Hollak CE,Aerts JM

    更新日期:2007-04-01 00:00:00

  • Relationship of lipoprotein(a) to variables of coagulation and fibrinolysis in a healthy population.

    abstract::In the Prospective Cardiovascular Münster (PROCAM) study, serum lipoprotein(a) [Lp(a)] and its relationship to pro- and anticoagulatory as well as fibrinolytic indices were determined in a large group of employees: 864 men (m) and 373 women (f), ages 16-65 years. Univariate statistical analysis showed Lp(a) concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Heinrich J,Sandkamp M,Kokott R,Schulte H,Assmann G

    更新日期:1991-11-01 00:00:00

  • Sensitive detection of KIT D816V in patients with mastocytosis.

    abstract:BACKGROUND:The 2447 A > T pathogenic variation at codon 816 of exon 17 (D816V) in the KIT gene, occurring in systemic mastocytosis (SM), leads to constitutive activation of tyrosine kinase activity and confers resistance to the tyrosine kinase inhibitor imatinib mesylate. Thus detection of this variation in SM patients...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.068205

    authors: Tan A,Westerman D,McArthur GA,Lynch K,Waring P,Dobrovic A

    更新日期:2006-12-01 00:00:00

  • Simultaneous detection of high-sensitivity cardiac troponin I and myoglobin by modified sandwich lateral flow immunoassay: proof of principle.

    abstract:BACKGROUND:Although numerous lateral flow immunoassays (LFIAs) have been developed and widely used, inadequate analytical sensitivity and the lack of multiple protein detection applications have limited their clinical utility. We developed a new LFIA device for the simultaneous detection of high-sensitivity cardiac tro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.171694

    authors: Zhu J,Zou N,Zhu D,Wang J,Jin Q,Zhao J,Mao H

    更新日期:2011-12-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • Discrete modular system for automation of radioimmunoassay of serum choriomammotropin.

    abstract::We describe a discrete automated radioimmunoassay system for determining choriomammotropin (placental lactogen) in human serum. With the present system it can be measured in as many as 37 unknown sera (50 muL) and three quality-control sera, in duplicate, within 1.5 h. The time required for sample preparation, incubat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hammond GL,Leinonen P,Vihko R

    更新日期:1979-01-01 00:00:00

  • Clinical evaluation of the Elecsys beta-CrossLaps serum assay, a new assay for degradation products of type I collagen C-tlopeptides.

    abstract:BACKGROUND:The Elecsys beta-CrossLaps serum assay measures type I collagen degradation fragments (beta-CTx) that contain the beta-isomerized octapeptide EKAHD-beta-GGR. We investigated the analytical performance of the assay and changes in beta-CrossLaps in patients with metabolic bone diseases. METHODS:The electroche...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Okabe R,Nakatsuka K,Inaba M,Miki T,Naka H,Masaki H,Moriguchi A,Nishizawa Y

    更新日期:2001-08-01 00:00:00

  • Rapid detection of leukemia cells by use of a complement-mediated cytolytic reaction and an imaging sensor system.

    abstract::We describe a system for detection of leukemia cells involving complement-mediated cytotoxic reaction and an image processing system, consisting of a charge-coupled-device image sensor, an image memory board, a personal computer, and a phase-contrast microscope. Then added to a cell suspension, monoclonal antibody spe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki M,Tamiya E,Kataoka T,Tokunaga T,Karube I

    更新日期:1987-04-01 00:00:00

  • Effect of dimethyl sulfoxide on serum osmolality.

    abstract::Consecutive values for serum osmolality measured in a patient exceeded (548 mOsm) the previously reported pathological range and, indeed, exceeded that generally considered compatible with life. The patient was receiving large amounts of intravenous dimethyl sulfoxide as part of an experimental protocol to control int...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Runckel DN,Swanson JR

    更新日期:1980-11-01 00:00:00