Energy-dispersive x-ray fluorescence spectroscopy and inductively coupled plasma emission spectrometry evaluated for multielement analysis in complex biological matrices.

Abstract:

:Energy-dispersive x-ray spectroscopy and inductively coupled plasma emission spectrometry were evaluated as methods for routine multielement analysis of biological material. Standard samples included Standard Reference Materials (National Bureau of Standards), compounded mixtures, and supplements that provided a wide range of elemental concentrations for analysis. Elements included in this study were Zn, Pb, Ni, Mn, Fe, Mg, Cu, Ca, As, Se, Br, Rb, and Sr. Standards were analyzed as unknowns by participating laboratories. The two methods were evaluated for sensitivity, precision, and accuracy, and the results compared to those obtained for atomic absorption spectrometric analysis of identical standard unknowns. Both methods compared favorably and both were determined to be highly reliable for such an application. Advantages and disadvantages of each method are compared and discussed.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Irons RD,Schenk EA,Giauque RD

subject

Has Abstract

pub_date

1976-12-01 00:00:00

pages

2018-24

issue

12

eissn

0009-9147

issn

1530-8561

journal_volume

22

pub_type

杂志文章
  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Combi scheme: new combined internal/external quality-assessment scheme in The Netherlands.

    abstract::The Dutch Foundation for Quality Assessment in Clinical Chemistry (SKZL) is the professional organization that conducts external quality-assessment schemes in The Netherlands. However, such schemes in fact assess the performance of the internal quality-control systems of the participating laboratories. In this paper w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steigstra H,Jansen RT,Baadenhuijsen H

    更新日期:1991-07-01 00:00:00

  • Rapid RHD Zygosity Determination Using Digital PCR.

    abstract:BACKGROUND:Paternal zygosity testing is used for determining homo- or hemizygosity of RHD in pregnancies that are at a risk of hemolytic disease of the fetus and newborn. At present, this is achieved by using real-time PCR or the Rhesus box PCR, which can be difficult to interpret and unreliable, particularly for black...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268698

    authors: Sillence KA,Halawani AJ,Tounsi WA,Clarke KA,Kiernan M,Madgett TE,Avent ND

    更新日期:2017-08-01 00:00:00

  • Analytical goals developed from the inherent error of medical tests.

    abstract::Biological variation is inherent in all medical tests and is a major source of error in clinical test interpretation. We use inherent test error due to biological variability as the touchstone by which to validate the clinical acceptability of analytical goals. Analytical goals should consist of sets of complementary ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ross JW,Fraser MD

    更新日期:1993-07-01 00:00:00

  • Assessing quality and functionality of DNA from fresh and archival dried blood spots and recommendations for quality control guidelines.

    abstract:BACKGROUND:Dried blood spots (DBS) are a convenient and inexpensive method for biobanking. Although many countries have established population-based DBS biobanks from neonatal screening programs, the quality and usefulness of DNA from DBS have not been extensively assessed. METHODS:We compared 4 common DNA extraction ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.087510

    authors: Sjöholm MI,Dillner J,Carlson J

    更新日期:2007-08-01 00:00:00

  • Delivering clinical laboratory services to intensive care units.

    abstract::In response to the pressures of cost reduction, we established and evaluated a carefully integrated program to deliver clinical laboratory services more promptly and efficiently to the intensive care units (ICUs). The new protocol reduced the steps and turnaround time from ordering tests by physicians to reporting res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steffes MW,Gillen JL,Fuhrman SA

    更新日期:1996-03-01 00:00:00

  • Prospective Associations of Systemic and Urinary Choline Metabolites with Incident Type 2 Diabetes.

    abstract:BACKGROUND:Several compounds in the choline oxidation pathway are associated with insulin resistance and prevalent diabetes; however, prospective data are scarce.We explored the relationships between systemic and urinary choline-related metabolites and incident type 2 diabetes in an observational prospective study amon...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.250761

    authors: Svingen GF,Schartum-Hansen H,Pedersen ER,Ueland PM,Tell GS,Mellgren G,Njølstad PR,Seifert R,Strand E,Karlsson T,Nygård O

    更新日期:2016-05-01 00:00:00

  • Effect of assay methodology on pharmacokinetic differences between cyclosporine Neoral and Sandimmune formulations.

    abstract::The new oral formulation of cyclosporine (CsA), Neoral (CsA-N), results in increased area under the curve (AUC) and decreased intra- and interindividual variation in blood concentrations and other pharmacokinetic (PK) parameters when compared with the current Sand-immune (CsA-S) formulation. The present study examines...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aspeslet LJ,LeGatt DF,Murphy G,Yatscoff RW

    更新日期:1997-01-01 00:00:00

  • A rapid, sensitive enzyme-linked immunoassay for human thyrotropin.

    abstract::In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tseng YC,Burman KD,Baker JR Jr,Wartofsky L

    更新日期:1985-07-01 00:00:00

  • Reference centiles for serum ferritin and percentage of transferrin saturation, with application to mutations of the HFE gene.

    abstract:BACKGROUND:The gene that causes most cases of hereditary hemochromatosis is designated HFE. Individuals with mutations in the HFE gene may have increased serum iron, transferrin saturation, and ferritin concentrations relative to individuals with the wild-type genotype. METHODS:We generated reference centiles for perc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koziol JA,Ho NJ,Felitti VJ,Beutler E

    更新日期:2001-10-01 00:00:00

  • Standardization with synthetic 22-kDa monomer human growth hormone reduces discrepancies between two monoclonal immunoradiometric assay kits.

    abstract::Discrepancies among different methods for assaying human growth hormone have been described in various studies. The two major sources of discordant results are the heterogeneity of the antibodies and the different standardization bases used by the assay manufacturers. We propose standardizing assays with 22-kDa biosyn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Banfi G,Marinelli M,Pontillo M,Bonini P

    更新日期:1992-10-01 00:00:00

  • Variability in the relationship between mean plasma glucose and HbA1c: implications for the assessment of glycemic control.

    abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.079756

    authors: Kilpatrick ES,Rigby AS,Atkin SL

    更新日期:2007-05-01 00:00:00

  • Creatine kinase: stability, inactivation, reactivation.

    abstract::I determined the in vitro biological half-lives or decay constants for creatine kinase isoenzymes at various temperatures. Values at 37 degrees C are consistent with values reported by others in vivo, which suggests that in vivo irreversible inactivation is primarily thermal. Reversible inactivation appears to be an o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morin LG

    更新日期:1977-01-01 00:00:00

  • Linked linear amplification for simultaneous analysis of the two most common hemochromatosis mutations.

    abstract:BACKGROUND:Two mutations in HFE, G845A (amino acid substitution C282Y) and C187G (H63D), are associated with hereditary hemochromatosis. We developed and validated a novel method, linked linear amplification (LLA), for detection of these two mutations. METHODS:Two segments of HFE were amplified by a multiplex LLA reac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.7.1050

    authors: Killeen AA,Breneman JW 3rd,Carillo AR,Ugozzoli LA,Lowery JD,Liu J,Hixson CS

    更新日期:2003-07-01 00:00:00

  • Enzyme immunoassay of thyroxin-binding globulin.

    abstract::We describe a new double-antibody enzyme radioimmunoassay for thyroxin-binding globulin (TBG) in serum. A TBG-beta-D-galactosidase complex was prepared with m-maleimidobenzoyl N-hydroxysuccinimide ester. The mean analytical recovery of TBG added to serum was 99%, sample volume and TBG value were linearly related, and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miyai K,Ito M,Hata N

    更新日期:1982-12-01 00:00:00

  • Simultaneous quantitation of zinc protoporphyrin and free protoporphyrin in erythrocytes by acetone extraction.

    abstract::Erythrocyte protoporphyrin content is increased in several human and veterinary disorders in which heme synthesis is disrupted. The nature of the defect determines whether zinc protoporphyrin, unchelated (free) protoporphyrin, or both are present in the erythrocytes. Extraction of the protoporphyrin into acetone/water...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hart D,Piomelli S

    更新日期:1981-02-01 00:00:00

  • Estimating glomerular filtration rate in kidney transplantation: is the new chronic kidney disease epidemiology collaboration equation any better?

    abstract:BACKGROUND:The new Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation was developed to address the systematic underestimation of the glomerular filtration rate (GFR) by the Modification of Diet in Renal Disease (MDRD) Study equation in patients with a relatively well-preserved kidney function. The per...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.135111

    authors: White CA,Akbari A,Doucette S,Fergusson D,Knoll GA

    更新日期:2010-03-01 00:00:00

  • Immunoassay of low concentrations of albumin in urine by latex particle counting.

    abstract::We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 5...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cambiaso CL,Collet-Cassart D,Lievens M

    更新日期:1988-02-01 00:00:00

  • Oligosaccharide analysis in urine by maldi-tof mass spectrometry for the diagnosis of lysosomal storage diseases.

    abstract:BACKGROUND:There are 45 known genetic diseases that impair the lysosomal degradation of macromolecules. The loss of a single lysosomal hydrolase leads to the accumulation of its undegraded substrates in tissues and increases of related glycoconjugates in urine, some of which can be detected by screening of free oligosa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.201053

    authors: Xia B,Asif G,Arthur L,Pervaiz MA,Li X,Liu R,Cummings RD,He M

    更新日期:2013-09-01 00:00:00

  • Development of a homogeneous assay for measurement of small dense LDL cholesterol.

    abstract:BACKGROUND:Plasma concentrations of small dense (sd)-LDL are associated with the prevalence of cardiovascular events. However, the special equipment and long assay times required for sd-LDL measurement have hindered its clinical application. Herein, we report development of a simple homogeneous assay for sd-LDL-cholest...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.149559

    authors: Ito Y,Fujimura M,Ohta M,Hirano T

    更新日期:2011-01-01 00:00:00

  • Detection of Chromosomal Translocation in Hematologic Malignancies by a Novel DNA-Based Looped Ligation Assay (LOLA).

    abstract:BACKGROUND:Disease-defining chromosomal translocations are seen in various neoplasms, especially in lymphomas and leukemias. Translocation detection at the DNA level is often complicated by chromosomal breakpoints that are distributed over very large regions. We have developed a ligation-based assay [the looped ligatio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.270140

    authors: Harada S,Sizzle E,Lin MT,Gocke CD

    更新日期:2017-07-01 00:00:00

  • Meconium nicotine and metabolites by liquid chromatography-tandem mass spectrometry: differentiation of passive and nonexposure and correlation with neonatal outcome measures.

    abstract:BACKGROUND:Meconium analysis is a diagnostically sensitive and objective alternative to maternal self-report for detecting prenatal tobacco exposure. Nicotine and metabolite disposition in meconium is poorly characterized, and correlation of analytes' concentrations with neonatal outcomes is unexplored. Our objectives ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.109173

    authors: Gray TR,Magri R,Shakleya DM,Huestis MA

    更新日期:2008-12-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Metabolic response of humans to ingestion of nicotinic acid and nicotinamide.

    abstract::The identification of nicotinamide-N1-oxide as a metabolite in the urine of a schizophrenic patient prompted a study of the relative metabolism of nicotinic acid and nicotinamide in mental patients and healthy volunteers. Metabolites quantified included N1-methyl-2-pyridone-5-carboxamide, N1-methyl-4-pyridone-3-carbox...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mrochek JE,Jolley RL,Young DS,Turner WJ

    更新日期:1976-11-01 00:00:00

  • Raising monospecific antibodies by use of protein components prestained with Remazol Brilliant Blue and separated by disc electrophoresis on polyacrylamide gel.

    abstract::We have reported (Clin Chem 29: 42-44, 1983) that prestaining with Remazol Brilliant Blue permits direct visualization of serum components on disc electrophoresis, and apparently purifies the proteins well. Here we have cut out the bands corresponding to the prestained albumin and transferrin after disc electrophoresi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Saoji AM,Jad CY,Yemul VL,Khare PM,Kelkar SS

    更新日期:1984-07-01 00:00:00

  • Light-chain ratios of immunoglobulins G, A, and M determined by enzyme immunoassay.

    abstract::We describe an enzyme-linked immunosorbent assay for determination of light-chain ratios for IgG, IgA, and IgM in serum. A commercial serum with known overall kappa and lambda concentrations was used as standard. To capture the respective immunoglobulins, we used antibodies to gamma, lambda and mu chains coated onto m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chui SH,Lam CW,Lai KN

    更新日期:1990-03-01 00:00:00

  • Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

    abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simon M,Cuan J

    更新日期:1980-11-01 00:00:00

  • Immunochemical determination of human immunoglobulins: use of kinetic turbidimetry and a 36-place centrifugal analyzer.

    abstract::We describe the measurement of human immunoglobulins IgG, IgA, and IgM in diluted sera, with diluted commercial monospecific antisera, with use of a 36-place centrifugal analyzer (RotoChem IIa; American Instrument Co., Silver Spring, MD 20920). The assay involves a two-point kinetic turbidimetric technique. The change...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Williams RJ,Lichti DA,Griffith F,Thies AC

    更新日期:1979-04-01 00:00:00

  • Microcalorimetric determination of glucose in reference samples of serum.

    abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Goldberg RN

    更新日期:1976-10-01 00:00:00