Abstract:
:Discrepancies among different methods for assaying human growth hormone have been described in various studies. The two major sources of discordant results are the heterogeneity of the antibodies and the different standardization bases used by the assay manufacturers. We propose standardizing assays with 22-kDa biosynthetic monomer human growth hormone diluted with the diluents supplied by the kit manufacturers. In a study of two monoclonal immunoradiometric assays (Hybritech, specific for the 22-kDa monomer; Sorin, recognizing also a 20-kDa variant hormone), standardization with 22-kDa monomer human growth hormone reduced by 63% the differences in results for 44 serum samples from children. The use of 22-kDa human growth hormone as a common standard, highly pure and easily available in large quantities, could help limit the interpretative problems in growth diagnostics.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Banfi G,Marinelli M,Pontillo M,Bonini Psubject
Has Abstractpub_date
1992-10-01 00:00:00pages
2107-10issue
10eissn
0009-9147issn
1530-8561journal_volume
38pub_type
杂志文章abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1981-07-01 00:00:00
abstract::In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-08-01 00:00:00
abstract::The serum pancreolauryl test has limited sensitivity for detecting mild pancreatic insufficiency. The aim of this study was to optimize the serum pancreolauryl test so as to increase the probability of positive results in patients with chronic pancreatitis. The study had three parts. First, the sampling time was optim...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-05-01 00:00:00
abstract:BACKGROUND:The liver is frequently subject to insult because of viral infection, alcohol abuse, or toxic chemical exposure. Extensive research has been conducted to identify blood markers that can better discern liver damage, but little progress has been achieved in clinical practice. Recently, circulating microRNAs (m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.147850
更新日期:2010-12-01 00:00:00
abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-04-01 00:00:00
abstract::Radioimmunoassay of triiodothyronine was performed with a homogeneous incubation system. Bound and free ligand were separated by partitioning in an aqueous two-phase system. The agreement between the results obtained with this technique and conventional heterogeneous radioimmunoassay was very good (r = 0.981). ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-05-01 00:00:00
abstract:BACKGROUND:The association of changes in oxidative and proinflammatory states with vascular function after diet and exercise intervention among obese children has not been previously explored. METHODS:In this 6-week diet and exercise intervention study in 35 obese children, age 12 to 18 years, we evaluated the relatio...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2007.089953
更新日期:2008-01-01 00:00:00
abstract::We describe a new multilayer immunoassay element for the determination of haptens in undiluted serum and plasma. Polysaccharide layers are coated onto a plastic base. The signal layer contains an immobilized antibody and a fluorescent-labeled hapten. A second layer, containing a pigment, acts as an optical screen. Sam...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-09-01 00:00:00
abstract::Owing to increased enzymatic hydrolysis of glutamine, additional ammonia is formed in blood and plasma specimens with increased gamma-glutamyltransferase activity (gamma-GT, EC 2.3.2.2.). The close correlation between gamma-GT and glutaminase (EC 3.5.1.2) activities (r = 0.97) in plasma, the inhibition with 6-diazo-5-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-08-01 00:00:00
abstract::We describe a single-cuvette enzyme-linked immunosorbent assay (ELISA) based on enzymic rate kinetics. This kinetic assay can yield linear quantitative data on immunoglobin concentrations. Optimum assay conditions, component concentrations, reaction intervals, and pH are described. Assay linearity and sensitivity are ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-08-01 00:00:00
abstract::We are developing a method for quantifying plasma lipoproteins by proton nuclear magnetic resonance (NMR) spectroscopy that offers advantages over existing clinical methods. We showed that the major lipoproteins have distinct NMR properties sufficient to permit their concentrations to be extracted from a computer line...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-09-01 00:00:00
abstract::I evaluated use of the fluorescence polarization technique to measure neocarzinostatin, a proteinaceous antitumor antibiotic, and its antibody, in serum. The antigen (neocarzinostatin), labeled with fluorescein isothiocyanate, was allowed to interact with its antibody in a cuvet, in the instrument, yielding an increas...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-12-01 00:00:00
abstract::This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidim...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-06-01 00:00:00
abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.026591
更新日期:2004-04-01 00:00:00
abstract::Single-spin density-gradient ultracentrifugation (DUC) has proven to be a reproducible method for detection of low-density-lipoprotein (LDL) heterogeneity. Recently another method has been described for this: gradient gel electrophoresis (GGE) of serum, a method that might be more suitable for screening. To gain insig...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-06-01 00:00:00
abstract::We describe the interlaboratory testing of a candidate Reference Method (Part I) for uric acid in serum. The method is based on the ultrasound spectrophotometric quantitation of uric acid before and after incubation with uricase. A comprehensive investigation involving 12 laboratories was organized to document the tra...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-02-01 00:00:00
abstract:BACKGROUND:Technological advances have resulted in a renaissance of proteomic studies directed at finding markers of disease progression, diagnosis, or responsiveness to therapy. Renal diseases are ideally suited for such research, given that urine is an easily accessible biofluid and its protein content is derived mai...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2011.165969
更新日期:2012-02-01 00:00:00
abstract:BACKGROUND:About 5% of patients with neurofibromatosis type 1 (NF1) bear constitutional microdeletions that encompass NF1 (neurofibromin 1) and neighboring genes. These patients are characterized by the development of a high number of dermal neurofibromas (dNFs), mental retardation, and an increased risk of developing ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2012.194217
更新日期:2013-06-01 00:00:00
abstract::We describe a discrete automated radioimmunoassay system for determining choriomammotropin (placental lactogen) in human serum. With the present system it can be measured in as many as 37 unknown sera (50 muL) and three quality-control sera, in duplicate, within 1.5 h. The time required for sample preparation, incubat...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-01-01 00:00:00
abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-05-01 00:00:00
abstract::We describe a liquid-chromatographic assay for AZT in human plasma and urine. This assay involves the use of two internal standards, allowing reference of AZT peaks to the appropriate internal standard, the choice depending on the range of concentrations encountered. This method is isocratic, specific, sensitive enoug...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-08-01 00:00:00
abstract:BACKGROUND:Variability among assays used to measure intact parathyroid hormone (iPTH) is of particular concern because of the routine use of iPTH assay results to guide management of osteodystrophy and calcium metabolism in patients with end-stage renal disease (ESRD). The aim of this study was to determine the extent ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.071589
更新日期:2006-09-01 00:00:00
abstract:BACKGROUND:Serial measurements of neurohormones have been shown to improve prognostication in the setting of acute heart failure (HF) or chronic HF without therapeutic intervention. We investigated the prognostic role of serial measurements of emerging neurohormones and BNP in a cohort of chronic HF patients undergoing...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.125856
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2005.052456
更新日期:2005-11-01 00:00:00
abstract:BACKGROUND:Dried blood spots (DBS) are a convenient and inexpensive method for biobanking. Although many countries have established population-based DBS biobanks from neonatal screening programs, the quality and usefulness of DNA from DBS have not been extensively assessed. METHODS:We compared 4 common DNA extraction ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.087510
更新日期:2007-08-01 00:00:00
abstract::If there were enzymatically inactive B subunits in a solution containing lactate dehydrogenase (LD) B4 prepared from the hemolysates of heterozygous individuals with LD-B subunit deficiency, the inactive subunits would compete with normal subunits for antibodies to the B4 subunit. Using the activity of normal LD-B4 as...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-01-01 00:00:00
abstract:BACKGROUND:Hyperglycosylated human chorionic gonadotropin (hCG-h) contains larger and more complex carbohydrate chains than regular human chorionic gonadotropin (hCG). hCG-h is thought to be the major form of hCG produced by testicular cancers and it has been suggested to play a key role in tumor invasion, but studies ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2012.183723
更新日期:2012-07-01 00:00:00