Abstract:
:If there were enzymatically inactive B subunits in a solution containing lactate dehydrogenase (LD) B4 prepared from the hemolysates of heterozygous individuals with LD-B subunit deficiency, the inactive subunits would compete with normal subunits for antibodies to the B4 subunit. Using the activity of normal LD-B4 as an index, we could ascertain the proportion of free antigen (LD-B4) and antibody-antigen complexes (LD-B4-anti-LD-B4) and calculate the apparent equilibrium constant, Keq. Doing so, we found the value for Keq in LD-B subunit deficiency to be smaller than that for normal controls. Evidently the expected competitive reaction takes place. We conclude that heterozygous individuals with LD-B subunit deficiency do indeed produce variant (enzymatically inactive) B subunits of LD.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Maekawa M,Sudo K,Kanno Tsubject
Has Abstractpub_date
1986-01-01 00:00:00pages
116-9issue
1 Pt 1eissn
0009-9147issn
1530-8561journal_volume
32pub_type
杂志文章abstract::The clinical utilities of the emerging biochemical markers for mammary adenocarcinoma CA 15-3, CA 549, CA M26, CA M29, and MCA (mucin-like carcinoma-associated antigen) were assessed by a formal rating according to six desirable marker characteristics. All five indicators similarly have good specificities but limited ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1993-11-01 00:00:00
abstract::We compared the ionic activity of sodium, as measured with glass electrodes, with sodium concentration in 23 healthy persons, 15 persons with acute renal failure, and before and after dialysis in 46 patients with chronic renal failure. In healthy persons the mean (+/- SEM) sodium concentration was 139.1 +/- 0.6 mmol/L...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-11-01 00:00:00
abstract:BACKGROUND:24,25-Dihydroxyvitamin D [24,25(OH)2D] in serum may be both a nuisance and nutritionally valuable. METHODS:We investigated the impact of 24,25(OH)2D3 on the performance of commercially available immunoassays for serum total 25-hydroxyvitamin D [25(OH)D] using (a) serum from a nationally representative sampl...
journal_title:Clinical chemistry
pub_type: 杂志文章,随机对照试验
doi:10.1373/clinchem.2014.234955
更新日期:2015-04-01 00:00:00
abstract:BACKGROUND:Recent studies show that the haptoglobin phenotype in individuals with diabetes mellitus is an important factor for predicting the risk of myocardial infarction, cardiovascular death, and stroke. Current methods for haptoglobin phenotyping include PCR and gel electrophoresis. A need exists for a reliable met...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2015.244004
更新日期:2016-01-01 00:00:00
abstract::Carbohydrate-deficient transferrin (CDT) may now be the most valuable biological marker for diagnosis of alcohol abuse. We compared the diagnostic performance of two new CDT tests, Axis %CDT turbidimetric immunoassay (TIA) and Axis %CDT HPLC, against Specialty Laboratories' isoelectric focusing/immunoblotting/laser de...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1997-06-01 00:00:00
abstract::Major discoveries have been made in the past few years on the structure and mode of biosynthesis of serum albumin. The complete amino acid sequence of this protein has been determined, and its covalent structure shown to be a single peptide chain grouped into a series of nine disulfide-bonded loops. These loops appear...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1977-01-01 00:00:00
abstract::We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay cor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-10-01 00:00:00
abstract:BACKGROUND:Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.176545
更新日期:2012-03-01 00:00:00
abstract:BACKGROUND:In patient and population samples, generation of analytical results that are comparable and independent of the measurement system, time, and location is essential for the utility of laboratory information supplied in healthcare. Obtaining analytical measurement results with such characteristics is the aim of...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2008.107052
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.071555
更新日期:2006-11-01 00:00:00
abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-07-01 00:00:00
abstract::Purified arylsulfatase A (EC 3.1.6.1) from human urine was radioiodinated under conditions that caused no significant loss of antigenic activity. We used this labeled arylsulfatase A (specific radioactivity 4-7.5 Ci/g) together with nonlabeled enzyme and rabbit antiserum produced against homogeneous enzyme to develop ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-03-01 00:00:00
abstract::Using high-performance liquid chromatography and gas chromatography, we reevaluated the 24-h influence of a serotonin- and dopamine-rich diet on platelet serotonin and serotonin, 5-hydroxyindoleacetic acid (5-HIAA), and major catecholamine metabolites in the urine of 15 healthy adults. Although there were significant ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-09-01 00:00:00
abstract::The herbicide paraquat (1,1'-dimethyl-4,4'-bipyridylium dichloride; PQ), is a poison known to cause delayed mortality due to lung and kidney injuries. High-resolution proton nuclear magnetic resonance (1H NMR) spectroscopy has been extensively applied in evaluating nephrotoxicity by the characteristic perturbations in...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-06-01 00:00:00
abstract::A one-stage semiautomated method for estimating total phospholipids in plasma is reported. The phospholipids are extracted into aqueous ethanol, combined with a Lewis acid, and the change in pH is monitored colorimetrically. The method, compared with the acid digestion method of Gomori [J. Lab. Clin. Med. 27, 955 (194...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-09-01 00:00:00
abstract::We present the results of measurements of alkaline phosphatase activity from interlaboratory transferability studies conducted by 12 laboratories in five countries. The variability, as demonstrated by within-day precision (CV less than or equal to 2.6%), between-day precision (CV less than or equal to 3.6%), and betwe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-05-01 00:00:00
abstract::We report the presence of complexes between aspartate aminotransferase (AST, EC 2.6.1.1) and immunoglobulin (Ig) in the serum of a patient suffering from lung cancer with metastasis to the liver. After fractionation of the serum by gel filtration, AST-Ig complexes (AST-IgA, AST-IgG) were demonstrated by counterimmunoe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-02-01 00:00:00
abstract::Ammonia concentrations in plasma may increase because of contamination and deterioration of blood components during specimen handling and storage. Using replicate specimens from healthy volunteers, we studied influences of specimen processing and storage procedures on ammonia measurements made with a self-contained re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-06-01 00:00:00
abstract::Five genetic defects have been established as risk factors for venous thrombosis. Three are protein C, protein S, and antithrombin deficiencies, defects in the anticoagulant pathways of blood coagulation. Together they can be found in approximately 15% of families with inherited thrombophilia. Their laboratory diagnos...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1997-09-01 00:00:00
abstract:BACKGROUND:The liver is frequently subject to insult because of viral infection, alcohol abuse, or toxic chemical exposure. Extensive research has been conducted to identify blood markers that can better discern liver damage, but little progress has been achieved in clinical practice. Recently, circulating microRNAs (m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.147850
更新日期:2010-12-01 00:00:00
abstract::Six different procedures for radioiodination of mouse epidermal growth factor (EGF) all resulted in a heterogeneous 125I-labeled EGF preparation, as analyzed by reversed-phase HPLC. EGF preparations that had been iodinated with Chloramine T, lodogen, or lodo-beads were found mainly to consist of oxidized 125I-labeled ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:We evaluated the completeness of reporting of diagnostic test accuracy (DTA) systematic reviews using the recently developed Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA)-DTA guidelines. METHODS:MEDLINE® was searched for DTA systematic reviews published October 2017 to January 2...
journal_title:Clinical chemistry
pub_type: 杂志文章,meta分析
doi:10.1373/clinchem.2018.292987
更新日期:2019-02-01 00:00:00
abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-01-01 00:00:00
abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.152009
更新日期:2010-12-01 00:00:00
abstract::We present a unified approach to the use of linear models and matrix least squares with the intention of providing a better understanding of the techniques themselves and of the statistics that arise from these techniques as they are used in clinical chemistry. Emphasis is placed on the importance of appropriate exper...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-06-01 00:00:00
abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.057216
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC wa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.147124
更新日期:2010-09-01 00:00:00
abstract::We describe a high-performance liquid chromatographic method for the quantitative determination of gentamicin in serum. The antibiotic was separated from serum by passage through a silicic acid column, derivatized with o-phthalaldehyde, and eluted with ethanol. The derivatized gentamicin was then separated into all th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-12-01 00:00:00
abstract:BACKGROUND:High-resolution DNA melting analysis of small amplicons is a simple and inexpensive technique for genotyping. Microfluidics allows precise and rapid control of temperature during melting. METHODS:Using a microfluidic platform for serial PCR and melting analysis, 4 targets containing single nucleotide varian...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.276147
更新日期:2017-10-01 00:00:00
abstract::To demonstrate oligoclonal IgG bands (I) in unconcentrated cerebrospinal fluid, we used isoelectric focusing in agarose followed by protein transfer to cellulose nitrate membrane, double-antibody peroxidase labeling, and avidin-biotin amplification. I can be reliably seen after isoelectric focusing of 5-microL specime...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-07-01 00:00:00