Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

Abstract:

:This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 determinations at two different concentrations were 5.5 and 5.8%. The corresponding between-assay CVs were 7.9 and 9.2%. We saw no interference from any components of urine or serum. The mean urinary excretion by 30 healthy subjects, as determined by this method, was 101 micrograms/g of creatinine (SD 38.8). The concentration in serum averaged 43 mg/L (SD 12.1).

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Lucertini S,Valcavi P,Mutti A,Franchini I

subject

Has Abstract

pub_date

1984-01-01 00:00:00

pages

149-51

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

30

pub_type

杂志文章
  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • A model for medical decision making and problem solving.

    abstract::Clinicians confront the classical problem of decision making under uncertainty, but a universal procedure by which they deal with this situation, both in diagnosis and therapy, can be defined. This consists in the choice of a specific course of action from available alternatives so as to reduce uncertainty. Formal ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Werner M

    更新日期:1995-08-01 00:00:00

  • Precipitation methods for high-density lipoprotein cholesterol measurement compared, and final evaluation under routine operating conditions of a method with a low sample-to-reagent ratio.

    abstract::We evaluated six precipitation methods for high-density lipoprotein cholesterol (HDL-chol) determination: the heparin/Mn2+ precipitation reagent method (Hep), two variants of the phosphotungstic acid/Mg2+ method (Tung-L and Tung-B), the dextran sulfate 50,000/Mg2+ method (Dex), the PEG 6000 method (PEG), and the PEG 6...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,Hessels M,Toenhake-Dijkstra H,Baadenhuijsen H

    更新日期:1997-04-01 00:00:00

  • Micro-scale method for theophylline in body fluids by reversed-phase, high-pressure liquid chromatography.

    abstract::We describe a micro-scale method for determining serum theophylline. The chromatography system includes a muBondapack C18 column and acetonitrile, 70 ml/liter of sodium acetate buffer (10 mmol/liter, ph 4.0) as the mobile phase. Test serum or plasma, 30 mul, is mixed with an equal quantity of a solution containing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orcutt JJ,Kozak PP Jr,Gillman SA,Cummins LH

    更新日期:1977-03-01 00:00:00

  • Comprehensive study of a thyroxin-analog-based assay for free thyroxin ("Amerlex FT4").

    abstract::The basic theory of thyroxin-analog-based radioimmunoassays for free thyroxin has been extended to evaluate definitively the effects arising from residual binding of the tracer analog to serum proteins. Using experimentally determined binding constants and computer simulation techniques, we studied the effects of thyr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilkins TA,Midgley JE,Barron N

    更新日期:1985-10-01 00:00:00

  • Quantifying manganese in lymphocytes to assess manganese nutritional status.

    abstract::To clarify whether manganese nutritional status is better reflected by the manganese concentration in lymphocytes or in whole blood, we injected manganese solutions intravenously into manganese-deficient rats and determined manganese concentrations in lymphocytes, whole blood, and various tissues. The manganese concen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matsuda A,Kimura M,Kataoka M,Ohkuma S,Sato M,Itokawa Y

    更新日期:1989-09-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Laboratory costs in the context of disease.

    abstract:BACKGROUND:To determine the contribution of laboratory costs to the overall costs of managing hospital patients with different diseases, we studied the costs of laboratory testing overall and in relation to the other costs incurred during hospitalization. METHODS:We used a database developed by the University HealthSy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Young DS,Sachais BS,Jefferies LC

    更新日期:2000-07-01 00:00:00

  • Novel technique for scanning of codon 634 of the RET protooncogene with fluorescence resonance energy transfer and real-time PCR in patients with medullary thyroid carcinoma.

    abstract:BACKGROUND:The multiple endocrine neoplasia 2 (MEN 2) syndromes [MEN 2A, MEN 2B, and familial medullary thyroid carcinoma (FMTC)] are caused by germline mutations of the RET protooncogene. Because 85% of MEN 2A patients and 30% of FMTC patients have mutations at codon 634, the recommended molecular analyses begin at ex...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ruiz A,Antiñolo G,Marcos I,Borrego S

    更新日期:2001-11-01 00:00:00

  • Role of biomarkers in identifying and understanding environmentally induced disease.

    abstract::Establishing associations between environmental agents and disease presents challenges to both epidemiologists and toxicologists, particularly in cases of complex gene-environment interactions and when there is a long latency between exposure and disease. Biologic markers, physiological signals that reflect exposure, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Silbergeld EK,Davis DL

    更新日期:1994-07-01 00:00:00

  • Delayed cytokine mRNA expression kinetics after T-lymphocyte costimulation: a quantitative measure of the efficacy of cyclosporin A-based immunosuppression.

    abstract:BACKGROUND:Because cyclosporin A (CsA) and glucocorticoids inhibit the production of interleukin-2 (IL-2) and other cytokines, quantitative analysis of cytokine mRNA might constitute a pharmacodynamic measure for immunosuppressive drug effects. We investigated whether immunosuppressive drugs influence cytokine mRNA exp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Härtel C,Fricke L,Schumacher N,Kirchner H,Müller-Steinhardt M

    更新日期:2002-12-01 00:00:00

  • Validated gas chromatographic-negative ion chemical ionization mass spectrometric method for delta(9)-tetrahydrocannabinol in sweat patches.

    abstract:BACKGROUND:A sensitive gas chromatography-negative ion chemical ionization mass spectrometry (GC/MS-NICI) method was developed and validated for the measurement of Delta(9)-tetrahydrocannabinol (THC) in human sweat patches. METHODS:THC-d(0) and THC-d(3) were added to worn blank sweat patches (PharmChek; PharmChem Inco...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2004.034868

    authors: Saito T,Wtsadik A,Scheidweiler KB,Fortner N,Takeichi S,Huestis MA

    更新日期:2004-11-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Centrifugal analyzer determination of ascorbate in serum or urine with Fe3+/Ferrozine.

    abstract::Measurement of serum ascorbate may be useful in long-term population studies because of the possible influence of ascorbate on numerous physiological factors. We describe an automated method for determining ascorbate in serum and urine by using the reduction of ferric iron by ascorbate and the formation of a color bet...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Butts WC,Mulvihill HJ

    更新日期:1975-09-01 00:00:00

  • Determination of shelf life and activation energy for tumor necrosis factor-alpha in cerebrospinal fluid samples.

    abstract::The cytokine rumor necrosis factor-alpha (TNF-alpha) plays a prominent role in the inflammatory response and has been quantified in several kinds of body fluids. A safe method for keeping samples under the best storage conditions for later studies is clearly needed. We estimated TNF-alpha shelf life by using an accele...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cruz Ruiz M,Recio Quijano F,López Cortés LF,Hebles Duvison M,Vázquez Rubio R

    更新日期:1996-05-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • Identification and Characterization of Cardiac Troponin T Fragments in Serum of Patients Suffering from Acute Myocardial Infarction.

    abstract:BACKGROUND:Cardiac troponin T (cTnT) is the preferred biomarker for the diagnosis of acute myocardial infarction (AMI). It has been suggested that cTnT is present predominantly in fragmented forms in human serum following AMI. In this study, we have used a targeted mass spectrometry assay and epitope mapping using West...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.261511

    authors: Streng AS,de Boer D,van Doorn WP,Bouwman FG,Mariman EC,Bekers O,van Dieijen-Visser MP,Wodzig WK

    更新日期:2017-02-01 00:00:00

  • Prognostic value of emerging neurohormones in chronic heart failure during optimization of heart failure-specific therapy.

    abstract:BACKGROUND:Serial measurements of neurohormones have been shown to improve prognostication in the setting of acute heart failure (HF) or chronic HF without therapeutic intervention. We investigated the prognostic role of serial measurements of emerging neurohormones and BNP in a cohort of chronic HF patients undergoing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.125856

    authors: Neuhold S,Huelsmann M,Strunk G,Struck J,Adlbrecht C,Gouya G,Elhenicky M,Pacher R

    更新日期:2010-01-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • Plasma concentrations of gamma-aminobutyric acid (GABA) and mood disorders: a blood test for manic depressive disease?

    abstract::gamma-Aminobutyric acid (GABA), an inhibitory neurotransmitter that serves about one-third of brain neurons, is involved in the development of depression and in the treatment of depression and mania with pharmacological therapy. Brain activity of GABA may be conveniently measured in plasma, and changes in plasma conce...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Petty F

    更新日期:1994-02-01 00:00:00

  • Polyacrylamide gel electrophoresis in quantification of high-density lipoprotein cholesterol.

    abstract::We evaluated a method for quantifying high-density lipoprotein cholesterol in plasma, based on electrophoretic migration of the prestained (with Sudan Black III) sample through a discontinuous polyacrylamide++ gel and densitometric integration of the stain associated with each class of lipoprotein. With this method, o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Roche D,Atger V,Le Quang NT,Girard A,Ekindjian OG

    更新日期:1985-11-01 00:00:00

  • Noninvasive prenatal diagnosis of duchenne muscular dystrophy: comprehensive genetic diagnosis in carrier, proband, and fetus.

    abstract:BACKGROUND:Noninvasive prenatal diagnosis of monogenic disorders using maternal plasma and targeted massively parallel sequencing is being investigated actively. We previously demonstrated that comprehensive genetic diagnosis of a Duchenne muscular dystrophy (DMD) patient is feasible using a single targeted sequencing ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.236380

    authors: Yoo SK,Lim BC,Byeun J,Hwang H,Kim KJ,Hwang YS,Lee J,Park JS,Lee YS,Namkung J,Park J,Lee S,Shin JY,Seo JS,Kim JI,Chae JH

    更新日期:2015-06-01 00:00:00

  • Identification of alpha(1)-antitrypsin variants in plasma with the use of proteomic technology.

    abstract:BACKGROUND:Proteomic technology permits the investigation of genetic metabolic diseases at the level of protein expression. Changes in the expression, polypeptide structure, and posttranslational modification of individual proteins can be detected in complex mixtures of proteins. METHODS:We used high-resolution two-di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mills K,Mills PB,Clayton PT,Johnson AW,Whitehouse DB,Winchester BG

    更新日期:2001-11-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • Efficient cleavage of conjugates of drugs or poisons by immobilized beta-glucuronidase and arylsulfatase in columns.

    abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toennes SW,Maurer HH

    更新日期:1999-12-01 00:00:00

  • Immunoradiometric assay for alpha gamma- and gamma gamma-enolase (neuron-specific enolase), with use of monoclonal antibodies and magnetizable polymer particles.

    abstract::Monoclonal antibodies were raised against neuron-specific enolase, gamma gamma-enolase, and used in an immunoradiometric assay (IRMA), with mono-disperse magnetizable particles as the solid phase. The assay's sensitivity was 0.4 microgram/L and the interassay coefficient of variation was less than 5% in the working ra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Paus E,Nustad K

    更新日期:1989-10-01 00:00:00

  • Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

    abstract::Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore FM,Simpson D

    更新日期:1989-08-01 00:00:00

  • Use of blood specimens collected on filter paper in screening for abnormal hemoglobins.

    abstract::Both cellulose acetate electrophoresis and citrate agar electrophoresis were performed on 834 blood samples collected on filter paper in Jamaica and shipped for testing to the National Hemoglobinopathy Standardization Laboratory at the U.S. National Center for Disease Control. Additionally, 30 blood samples collected ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schmidt RM,Brosious EM,Holland S,Wright JM,Serjeant GR

    更新日期:1976-05-01 00:00:00

  • Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry.

    abstract::A new method for the reliable identification of localized variations in DNA by detection of associated diagnostic products with matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. The diagnostic products are generated by the primer oligo base extension (PROBE) reaction, which req...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Braun A,Little DP,Köster H

    更新日期:1997-07-01 00:00:00

  • High-purity 4-nitrophenol: purification, characterization, and specifications for use as a spectrophotometric reference material.

    abstract::We describe specifications for high-purity 4-nitrophenol, which is suitable for spectrophotometric standardization. Such a reference material is needed in clinical enzymology to establish the proper molar absorptivity of 4-nitrophenol under final reaction conditions, particularly for measuring alkaline phosphatase act...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers GN Jr,McComb RB,Christensen RG,Schaffer R

    更新日期:1980-05-01 00:00:00