Delayed cytokine mRNA expression kinetics after T-lymphocyte costimulation: a quantitative measure of the efficacy of cyclosporin A-based immunosuppression.

Abstract:

BACKGROUND:Because cyclosporin A (CsA) and glucocorticoids inhibit the production of interleukin-2 (IL-2) and other cytokines, quantitative analysis of cytokine mRNA might constitute a pharmacodynamic measure for immunosuppressive drug effects. We investigated whether immunosuppressive drugs influence cytokine mRNA expression kinetics during T-cell costimulation. METHODS:We used a human whole blood assay to determine basal (unstimulated) IL-2, IL-4, and tumor necrosis factor-alpha (TNF-alpha) mRNA concentrations and expression kinetics after anti-CD3/anti-CD28 monoclonal antibody costimulation in kidney transplant recipients undergoing CsA-based immunosuppressive triple therapy and in healthy controls (ex vivo study I). The effect of CsA on IL-2 mRNA expression kinetics was also determined ex vivo in patients undergoing CsA monotherapy (ex vivo study II) and after in vitro addition of CsA. RESULTS:In ex vivo study I, basal TNF-alpha mRNA but not IL-2 and IL-4 mRNA was decreased in kidney transplant patients. We observed shifts in peak IL-2 and IL-4 (from 8 to 24 h) and TNF-alpha (from 4 to 8 h of costimulation) mRNA expression in kidney transplant patients after T-cell costimulation. In patients undergoing CsA monotherapy (ex vivo study II), the inhibitory effect of CsA was detectable as an individually delayed increase in IL-2 mRNA during costimulation. In vitro addition of CsA also induced a dose-independent displacement of IL-2 mRNA expression kinetics (i.e., a delay). CONCLUSIONS:A delayed increase in cytokine mRNA expression during T-cell costimulation may represent a sensitive effect of immunosuppression. The single analysis of one absolute or peak mRNA value could be misleading. For prospective studies involving measurement of cytokine mRNA, we therefore suggest the parameter "area of cytokine mRNA expression over time", which should include absolute cytokine mRNA values at two different time points of mRNA kinetics.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Härtel C,Fricke L,Schumacher N,Kirchner H,Müller-Steinhardt M

subject

Has Abstract

pub_date

2002-12-01 00:00:00

pages

2225-31

issue

12

eissn

0009-9147

issn

1530-8561

journal_volume

48

pub_type

杂志文章
  • Stabilized analysis of antidepressant drugs by solvent-recycled liquid chromatography: procedure and proposed resolution mechanisms for chromatography.

    abstract::In this efficient extraction and isocratic liquid-chromatographic procedure for measuring eight antidepressant drugs in serum (amoxapine, 8-hydroxyamoxapine, doxepin, desmethyldoxepin, imipramine, desipramine, amitriptyline, and nortriptyline), they are extracted from serum as a group by use of disposable solid-phase ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lensmeyer GL,Evenson MA

    更新日期:1984-11-01 00:00:00

  • Sensitivity of immunofixation electrophoresis for detecting IgM paraproteins in serum.

    abstract::Detection and characterization of small IgM paraproteins by immunoelectrophoresis are often difficult because of (a) slow diffusion of the macromolecular immunoglobulin, and (b) the obscuring of the light chain, especially kappa, by the light chains of background polyclonal immunoglobulin (the "umbrella effect"). Vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kahn SN,Bina M

    更新日期:1988-08-01 00:00:00

  • Advances in the Treatment of Hemophilia: Implications for Laboratory Testing.

    abstract:BACKGROUND:Until recently, clinical laboratories have monitored hemophilia treatment by measuring coagulation factors before/after infusion of human-derived or recombinant factors. Substantial changes are expected in the near future based on new therapeutic approaches that have been or are being developed. CONTENT:Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2017.284356

    authors: Tripodi A,Chantarangkul V,Novembrino C,Peyvandi F

    更新日期:2019-02-01 00:00:00

  • Bilirubin binding by primary sites of human serum albumin, with suppression of secondary-site interference by use of a high salt concentration.

    abstract::A high (2.0 mol/L) NaCl concentration apparently suppresses the secondary-site binding of bilirubin by human serum albumin. Thus if an excess of bilirubin is added to human serum albumin or to neonatal serum in buffer containing 0.1 mol of tris(hydroxymethyl)aminomethane and 2.0 mol of NaCl per liter (pH 7.5), and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rutkowski RB

    更新日期:1980-01-01 00:00:00

  • Screening newborn blood spots for 22q11.2 deletion syndrome using multiplex droplet digital PCR.

    abstract:BACKGROUND:The diagnosis of 22q11 deletion syndrome (22q11DS) is often delayed or missed due to the wide spectrum of clinical involvement ranging from mild to severe, often life-threatening conditions. A delayed diagnosis can lead to life-long health issues that could be ameliorated with early intervention and treatmen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.230086

    authors: Pretto D,Maar D,Yrigollen CM,Regan J,Tassone F

    更新日期:2015-01-01 00:00:00

  • Response-surface-optimized, zinc-enhanced assay for serum alkaline phosphatase.

    abstract::An optimized assay for alkaline phosphatase (EC 3.1.3.1) is reported. A discrete analyzer, the DuPont Automatic Clinical Analyzer (aca), was used for this study. The assay is based on results of response-surface experimental co-optimization techniques, and response is enhanced over the present aca assay. A key feature...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson JC,Hodges CT,Dobler GL,Williamson JA Jr

    更新日期:1981-07-01 00:00:00

  • Influences of specimen processing and storage conditions on results for plasma ammonia.

    abstract::Ammonia concentrations in plasma may increase because of contamination and deterioration of blood components during specimen handling and storage. Using replicate specimens from healthy volunteers, we studied influences of specimen processing and storage procedures on ammonia measurements made with a self-contained re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Howanitz JH,Howanitz PJ,Skrodzki CA,Iwanski JA

    更新日期:1984-06-01 00:00:00

  • Biological and clinical significance of haptoglobin polymorphism in humans.

    abstract::Haptoglobin is a hemoglobin-binding protein expressed by a genetic polymorphism as three major phenotypes: 1-1, 2-1, and 2-2. Most attention has been paid to determining haptoglobin phenotype as a genetic fingerprint used in forensic medicine. More recently, several functional differences between haptoglobin phenotype...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Langlois MR,Delanghe JR

    更新日期:1996-10-01 00:00:00

  • Isoelectric focusing in agarose: classification of genetic variants of alpha 1-antitrypsin.

    abstract::Polyacrylamide has been the matrix of choice for isoelectric focusing owing to the virtual absence of electroendosmosis in this medium. Certain inherent limitations associated with polyacrylamide have prompted some investigators to use low-electroendosmosis agarose for isoelectric focusing, but with limited success th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Stennis BJ,Schimbor CM

    更新日期:1983-02-01 00:00:00

  • Evaluation and comparison of immunoinhibition and immunoprecipitation methods for differentiating MB and BB from macro forms of creatine kinase isoenzymes in patients and healthy individuals.

    abstract::We compared results for measurements of creatine kinase isoenzyme MB (CK-MB) by immunoinhibition vs immunoprecipitation, using sera from 53 normal healthy individuals, 55 patients with increased CK-MB associated with acute myocardial infarction, and 42 patients whose blood exhibited one or more abnormal forms of CK by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu AH,Bowers GN Jr

    更新日期:1982-10-01 00:00:00

  • Reduced Testicular Steroidogenesis and Increased Semen Oxidative Stress in Male Partners as Novel Markers of Recurrent Miscarriage.

    abstract:BACKGROUND:Recurrent pregnancy loss, (RPL) affecting 1%-2% of couples, is defined as ≥3 consecutive pregnancy losses before 20-week' gestation. Women with RPL are routinely screened for etiological factors, but routine screening of male partners is not currently recommended. Recently it has been suggested that sperm qu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.289348

    authors: Jayasena CN,Radia UK,Figueiredo M,Revill LF,Dimakopoulou A,Osagie M,Vessey W,Regan L,Rai R,Dhillo WS

    更新日期:2019-01-01 00:00:00

  • Immunopeptidometric assay for enzymatically active prostate-specific antigen.

    abstract:BACKGROUND:Determinations of certain forms of prostate-specific antigen (PSA) have been shown to increase the specificity for prostate cancer (PCa). One such variant, proteolytically active PSA, is a potentially useful tumor marker, but it is not specifically recognized by antibodies. Using phage display libraries, we ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026146

    authors: Wu P,Zhu L,Stenman UH,Leinonen J

    更新日期:2004-01-01 00:00:00

  • Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry.

    abstract::A new method for the reliable identification of localized variations in DNA by detection of associated diagnostic products with matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. The diagnostic products are generated by the primer oligo base extension (PROBE) reaction, which req...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Braun A,Little DP,Köster H

    更新日期:1997-07-01 00:00:00

  • Immunofluorometric demonstration and quantification of placental protein 5 in the absence of pregnancy.

    abstract::This time-resolved immunofluorometric assay (IFMA) developed for measurement of placental protein 5 (PP5) involves two antibodies: a monoclonal anti-PP5 antibody attached to a solid phase and an europium(III) chelate-labeled polyclonal anti-PP5 antibody as a tracer. The measuring range is 0.05-100 micrograms/L and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bützow R,Alfthan H,Stenman UH,Suikkari AM,Bohn H,Seppälä M

    更新日期:1988-08-01 00:00:00

  • Screening for primary aldosteronism in essential hypertension: diagnostic accuracy of the ratio of plasma aldosterone concentration to plasma renin activity.

    abstract:BACKGROUND:The ratio of plasma aldosterone concentration to plasma renin activity (PRA) is considered the screening test of choice for primary aldosteronism. Uncertainty exists, however, regarding its diagnostic accuracy and the effects of antihypertensive drugs and dietary sodium balance on test characteristics. METH...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2004.041780

    authors: Schwartz GL,Turner ST

    更新日期:2005-02-01 00:00:00

  • Rate nephelometric measurement of rheumatoid factor in serum.

    abstract::We describe the measurement of rheumatoid factor in human sera with a rate nephelometer. The National Reference Preparation for Rheumatoid Factors is used to calibrate the assay in International Units. We used Hyland Positive Control, Level I, as a secondary standard. The standard curve is exponential, but is linear w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Hicks MJ,Williams RJ,Hinlicky J,Lichti DA

    更新日期:1979-11-01 00:00:00

  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • Measurement of cyclosporine concentrations in whole blood: HPLC and radioimmunoassay with a specific monoclonal antibody and 3H- or 125I-labeled ligand compared.

    abstract::We compared cyclosporine concentrations in whole blood as measured by HPLC and by RIA with a monoclonal antibody specific for cyclosporine with 3H- or 125I-labeled cyclosporine ligand. The 3H-RIA kit slightly underestimated cyclosporine concentrations (greater than 600 micrograms/L) in comparison with HPLC. Over a wid...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wolf BA,Daft MC,Koenig JW,Flye MW,Turk JW,Scott MG

    更新日期:1989-01-01 00:00:00

  • Quantifying spurious free T4 results attributable to thyroxine-binding proteins in serum dialysates and ultrafiltrates.

    abstract:BACKGROUND:Direct equilibrium dialysis and direct ultrafiltration free thyroxine (T(4)) assays rely on semipermeable membranes to exclude T(4)-binding serum proteins from dialysates and ultrafiltrates. The presence of these proteins in dialysates or ultrafiltrates will yield spuriously high free T(4) values when free T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.085316

    authors: Fritz KS,Wilcox RB,Nelson JC

    更新日期:2007-05-01 00:00:00

  • Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots.

    abstract::We have assessed the technical performance and robustness of NycoCard CRP Whole Blood, a near-patient test for C-reactive protein (CRP), when used in realistic daily routine situations in general practice clinics (GPC). Thirteen GPCs participated, five of them with technician staff. From 898 patients, split-sample mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dahler-Eriksen BS,Lassen JF,Petersen PH,Lund ED,Lauritzen T,Brandslund I

    更新日期:1997-11-01 00:00:00

  • Biological variability in concentrations of serum lipids: sources of variation among results from published studies and composite predicted values.

    abstract::To obtain the best estimates of the average intraindividual biological variability (CVb) in the concentrations of total cholesterol (TC), low-density lipoprotein cholesterol (LDLC), high-density lipoprotein cholesterol (HDLC), and triglyceride serum lipids in a person's blood, we evaluated results from 30 studies publ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:

    authors: Smith SJ,Cooper GR,Myers GL,Sampson EJ

    更新日期:1993-06-01 00:00:00

  • A liquid-chromatographic analysis for ritalinic acid [alpha-phenyl-alpha-(2-piperidyl) acetic acid] in serum.

    abstract::We describe a "high-performance" liquid-chromatographic assay for measuring ritalinic acid in 300 muL of serum. The procedure includes adsorption of ritalinic acid and internal standard (alpha,alpha-dimethyl-beta-emthylsuccinimide) from serum onto charcoal, from which both compounds are eluted with methanol. The metha...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Soldin SJ,Hill BM,Cahn YP,Swanson JM,Hill JG

    更新日期:1979-01-01 00:00:00

  • Metabolic relationship between urea and guanidino compounds as studied by automated fluorimetry of guanidino compounds in urine.

    abstract::In this automated system for assaying guanidino compounds, the compounds are resolved on an ion-exchange (Dowex 50) column, then reacted with phenanthrenequinone in alkaline solution. This mixture is then acidified and the resulting fluorescence is measured (lambda ex, 305 nm; lambda em, 395 nm). I applied the system ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Natelson S

    更新日期:1984-02-01 00:00:00

  • Glucocorticoid receptors in normal leukocytes: effects of age, gender, season, and plasma cortisol concentrations.

    abstract::We measured glucocorticoid receptors (GR) in mononuclear leukocytes (MNL) isolated from peripheral blood of 145 apparently healthy volunteers (86 men and 59 women). An age-related decrease in the number of GR was suggested between subjects younger than 20 years and elderly subjects; there was no apparent seasonal vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka H,Akama H,Ichikawa Y,Homma M,Oshima H

    更新日期:1991-10-01 00:00:00

  • Semi-automated direct colorimetric measurement of creatine kinase isoenzyme MB activity after extraction from serum by use of a CK-MB-specific monoclonal antibody.

    abstract::This semi-automated colorimetric assay for the MB isoenzyme of creatine kinase (EC 2.7.3.2) is based on a monoclonal antibody ("Conan-MB") specific for this isoenzyme and is a modification of a previously published method (Vaidya et al., Clin Chem 1986;32:657-63). A 0.64-cm bead coated with 2 to 3 micrograms of antibo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Landt Y,Vaidya HC,Porter SE,Whalen K,McClellan A,Amyx C,Parvin CA,Kessler G,Nahm MH,Dietzler DN

    更新日期:1988-03-01 00:00:00

  • Sodium activity, sodium concentration, and osmolality in plasma in acute and chronic renal failure.

    abstract::We compared the ionic activity of sodium, as measured with glass electrodes, with sodium concentration in 23 healthy persons, 15 persons with acute renal failure, and before and after dialysis in 46 patients with chronic renal failure. In healthy persons the mean (+/- SEM) sodium concentration was 139.1 +/- 0.6 mmol/L...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Langhoff E,Ladefoged J

    更新日期:1985-11-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • Simple spectrophotometric determination of urinary albumin by dye-binding with use of bromphenol blue.

    abstract::This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schosinsky KH,Vargas M,Luz Esquivel A,Chavarria MA

    更新日期:1987-02-01 00:00:00

  • Correlation between estrogen receptor protein and carcinoembryonic antigen in normal and carcinomatous human breast tissue.

    abstract::We determined estrogen receptor protein and carcinoembryonic antigen in cytosols prepared from 189 human breast carcinoma tissues, 85 benign or normal breast biopsies, and 101 tissue specimens metastatic from breast carcinoma. Carcinoembryonic antigen was observed in 70% of the primary carcinomatous tissues, 15% of th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Menendez-Botet CJ,Nisselbaum JS,Fleisher M,Rosen PP,Fracchia A,Robbins G,Urban JA,Schwartz MK

    更新日期:1976-08-01 00:00:00

  • Benign inherited hyperphosphatasemia of intestinal origin: report of two cases and a brief review of the literature.

    abstract::Two families with benign hyperphosphatasemia of intestinal origin were studied and compared with six other cases reported in the literature. No evidence of clinical abnormalities or explanations for the unusual enzyme concentrations were found. Agarose gel electrophoresis of alkaline phosphatase (ALP, EC 3.1.3.1) isoe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Panteghini M

    更新日期:1991-08-01 00:00:00