Screening for primary aldosteronism in essential hypertension: diagnostic accuracy of the ratio of plasma aldosterone concentration to plasma renin activity.

Abstract:

BACKGROUND:The ratio of plasma aldosterone concentration to plasma renin activity (PRA) is considered the screening test of choice for primary aldosteronism. Uncertainty exists, however, regarding its diagnostic accuracy and the effects of antihypertensive drugs and dietary sodium balance on test characteristics. METHODS:We measured PRA and aldosterone in 118 white adults [71 men and 47 women; mean (SD) age, 51 (7) years] with previously diagnosed essential hypertension. Measurements were made while individuals were on antihypertensive drug therapy, after a 2-week drug-free period, after 4 days of dietary sodium loading, and after acute furosemide diuresis. We measured 24-h urine aldosterone excretion and PRA on the 4th day of dietary sodium loading to establish the diagnosis of primary aldosteronism. ROC curves were constructed for ratios measured under each clinical condition, and likelihood ratios were determined for individuals on or off antihypertensive drug therapy. RESULTS:Fifteen patients [13%; 95% confidence interval (CI), 7-20%] met the reference standard for primary aldosteronism. The mean (SD) areas under the ROC curves did not differ significantly across conditions of measurement [range, 0.80 (0.10) to 0.85 (0.04); P = 0.72]. When measured on and off antihypertensive drug therapy, the 95% CIs for the optimum cutpoint for the ratio overlapped. Point estimates of sensitivity on and off therapy were 73% (95% CI, 50-96%) and 87% (70-100%), respectively, and specificities were 74% (65-83%) and 75% (66-84%). Under either condition, increased ratios were associated with 2.4- to 13-fold increases of posttest odds above pretest odds. CONCLUSIONS:The aldosterone:PRA ratio provides only fair diagnostic accuracy in screening for primary aldosteronism, but concomitant antihypertensive drug therapy or acute variation in dietary sodium balance does not adversely affect test accuracy. Reporting of likelihood ratios associated with ranges of values of the aldosterone:PRA ratio, rather than use of a single "optimum" cutpoint, may enhance the usefulness of the test.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Schwartz GL,Turner ST

doi

10.1373/clinchem.2004.041780

subject

Has Abstract

pub_date

2005-02-01 00:00:00

pages

386-94

issue

2

eissn

0009-9147

issn

1530-8561

pii

51/2/386

journal_volume

51

pub_type

临床试验,杂志文章
  • Associations between serum gamma-glutamyltransferase and apolipoproteins: relationships with hepatobiliary diseases.

    abstract::We studied the association between gamma-glutamyltransferase (GGT) and apolipoproteins A or B in serum of 42 patients with various hepatobiliary diseases. Binding of the enzyme to apolipoprotein A is not related to a clearly defined disease, but appears to be mainly influenced by the ratio of total cholesterol to GGT ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Artur Y,Wellman-Bednawska M,Jacquier A,Siest G

    更新日期:1984-08-01 00:00:00

  • High-pressure liquid-chromatographic separation of lactate dehydrogenase isoenzymes.

    abstract::The isoenzymes of lactate dehydrogenase (EC 1.1.1.27) were separated with excellent resolution in less than 1 h by high-pressure anion-exchange chromatography. These isoenzymes were determined in some tissue extracts and high-activity serum samples by this technique. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kudirka PJ,Schroeder RR,Hewitt TE,Toren EC Jr

    更新日期:1976-04-01 00:00:00

  • An interlaboratory study of measurement of aspartate aminotransferase activity with use of purified enzyme materials.

    abstract::The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Burtis CA,Sampson EJ,Bayse DD,McKneally SS,Whitner VS

    更新日期:1978-06-01 00:00:00

  • Automated measurement of amylase isoenzymes by a double kinetic assay with "blocked" beta-2-chloro-4-nitrophenyl maltopentaoside as substrate and with wheat germ inhibitor.

    abstract::We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Nishimura T,Noma A,Hamano K

    更新日期:1991-08-01 00:00:00

  • Urokinase plasminogen activator: a prognostic marker in breast cancer including patients with axillary node-negative disease.

    abstract::Urokinase plasminogen activator (uPA) is a serine protease causally involved in cancer invasion and metastasis. In this study, high concentrations of uPA in primary breast cancers were independently associated with both a shortened disease-free interval and overall survival. For the disease-free interval as endpoint, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duffy MJ,Duggan C,Mulcahy HE,McDermott EW,O'Higgins NJ

    更新日期:1998-06-01 00:00:00

  • Performance of the Hitachi 705 evaluated.

    abstract::We evaluated a new discrete analyzer, the Hitachi 705. The instrument can process sequentially as many as 19 different enzymes or other analytes, with a throughput of 180 tests per hour. We evaluated the spectrophotometer, the sample and reagent probes, and the performance for 11 assays: creatine kinase, aspartate ami...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Douville P,Forest JC

    更新日期:1983-04-01 00:00:00

  • Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma.

    abstract::We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jaouhari J,Schiele F,Dragacci S,Tarallo P,Siest JP,Henny J,Siest G

    更新日期:1992-10-01 00:00:00

  • Description of a computer program to assess cancer antigen 15.3, carcinoembryonic antigen, and tissue polypeptide antigen information during monitoring of metastatic breast cancer.

    abstract::It is time-consuming to process and compare the clinical and marker information registered during monitoring of breast cancer patients. To facilitate the assessment, we developed a computer program for interpreting consecutive measurements. The intraindividual biological variation, the analytical precision profile, th...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Sölétormos G,Schiøler V

    更新日期:2000-08-01 00:00:00

  • Determination of quinidine by high-performance liquid chromatography.

    abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Powers JL,Sadee W

    更新日期:1978-02-01 00:00:00

  • Development of a rapid and sensitive immunofluorometric assay for glutathione S-transferase A.

    abstract:BACKGROUND:The short half-life of the alpha-class glutathione S-transferases (GSTAs) in plasma combined with their even distribution throughout the liver lobule suggests that they may be useful complements to the more traditionally used liver markers. However, the currently available assays for measuring GSTAs in biolo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dajani LK,Paus E,Warren DJ

    更新日期:2001-05-01 00:00:00

  • Improved thin-layer chromatographic determination of phospholipids in gastric aspirate from newborns, for assessment of lung maturity.

    abstract::This one-dimensional thin-layer chromatographic method is used for assay of phospholipids in the gastric aspirate of newborns. The solvent mixture (chloroform/hexane/methanol/glacial acetic acid/water, 12/7/4/3/0.3 by vol) completely resolves lecithin, sphingomyelin, phosphatidylinositol, phosphatidylserine, phosphati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Serrano de la Cruz D,Santillana E,Mingo A,Fuenmayor G,Pantoja A,Fernández E

    更新日期:1988-04-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Amniotic fluid acetylcholinesterase activity and alpha-fetoprotein in chromosomal anomalies and neural tube defects.

    abstract::Measurement of alpha-fetoprotein concentration and acetylcholinesterase activity in amniotic fluid can be used to identify chromosomal defects as well as neural tube defects. In seven cases of trisomy 21 and one case of partial trisomy 3, alpha-fetoprotein concentrations were below the reference range but values for a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buamah PK,Skillen AW,Harrison J,Davison V

    更新日期:1985-04-01 00:00:00

  • Real-time quantitative PCR for the measurement of MYCN amplification in human neuroblastoma with the TaqMan detection system.

    abstract:BACKGROUND:Neuroblastoma is the most common extracranial malignant solid tumor in children under 5 years and is characterized by a wide clinical and biological heterogeneity, from spontaneously regressive forms to cancers with a rapid and fatal progression. MYCN oncogene amplification is considered the most important p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raggi CC,Bagnoni ML,Tonini GP,Maggi M,Vona G,Pinzani P,Mazzocco K,De Bernardi B,Pazzagli M,Orlando C

    更新日期:1999-11-01 00:00:00

  • Quantifying manganese in lymphocytes to assess manganese nutritional status.

    abstract::To clarify whether manganese nutritional status is better reflected by the manganese concentration in lymphocytes or in whole blood, we injected manganese solutions intravenously into manganese-deficient rats and determined manganese concentrations in lymphocytes, whole blood, and various tissues. The manganese concen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matsuda A,Kimura M,Kataoka M,Ohkuma S,Sato M,Itokawa Y

    更新日期:1989-09-01 00:00:00

  • Gas-chromatographic analysis for chlorpromazine and some of its metabolites in human serum, with use of a nitrogen detector.

    abstract::We describe a gas-chromatographic method for measuring chlorpromazine and its metabolites chlorpromazine sulfoxide, mono-N-desmethylchlorpromazine, and di-N-desmethylchlorpromazine at therapeutic concentrations in human serum, with use of a nitrogen detector. The compounds are extracted from serum at pH 10.5 into hexa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bailey DN,Guba JJ

    更新日期:1979-07-01 00:00:00

  • Direct determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.

    abstract::A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iwata R,Hayashi T,Nakao Y,Yamaki M,Yoshimasa T,Ito H,Saito Y,Mukoyam M,Nakao K

    更新日期:1996-08-01 00:00:00

  • One-tube radiotransinassay for determination of cortisol at ambient temperature.

    abstract::After extraction of the sample (on filter paper) in the counting vial, cortisol is assayed by adding 50 microL of horse serum containing tritiated cortisol, and 2 mL of toluene scintillator, shaking for 20 min, and counting the radioactivity in a liquid-scintillation counter at ambient temperature. The method can be a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Murphy BE,Barta A

    更新日期:1987-07-01 00:00:00

  • Kinetic determination of serum sorbitol dehydrogenase activity with a centrifugal analyzer.

    abstract::We describe a mechanized method for centrifugal analyzer determination of sorbitol dehydrogenase in serum, based on conversion of D-fructose to sorbitol with simultaneous oxidation of NADH, in triethanolamine buffer at pH 7.4 and 30 degrees C. The standard curve for this assay is linear to 200 U of activity per liter ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dooley JF,Turnquist LJ,Racich L

    更新日期:1979-12-01 00:00:00

  • Low bias in assayed values of lipoprotein antigens--lipoprotein(a) and apolipoproteins A-I and B--in midday postprandial blood specimens compared with morning fasting specimens.

    abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Emancipator K

    更新日期:1992-03-01 00:00:00

  • C-reactive protein and coronary heart disease: predictive test or therapeutic target?

    abstract:BACKGROUND:The hepatocyte-derived acute-phase reactant C-reactive protein (CRP) has been the subject of intense research over the last 2 decades for its possible role in the pathogenesis of cardiovascular diseases. This research has spawned interest in the use of the blood concentration of CRP for predicting a first co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.115923

    authors: Hingorani AD,Shah T,Casas JP,Humphries SE,Talmud PJ

    更新日期:2009-02-01 00:00:00

  • Activation of alanine aminotransferase in serum by pyridoxal phosphate.

    abstract::Alanine aminotransferase activity in serum increases significantly when serum is incubated with pyridoxal phosphate. The increase depends on the L-alanine concentration in the final assay mixture, being greatest at 800 mmol/liter. Preincubation of 22 normal sera, in a 10:1 ratio with an 8.09 mmol/liter pyridoxal phosp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lustig V

    更新日期:1977-02-01 00:00:00

  • Cross reactions in radioimmunoassay: a mathematical model for correcting assay results, as exemplified by eliminating the interference of intact thyrotropin in an assay of its beta subunit.

    abstract::To correct the results of a radioimmunoassay for beta-thyrotropin (TSH) subunit by eliminating the proportion ascribable to intact TSH, we have devised a method that experimentally reproduces the conditions under which the interference develops. Beta-TSH subunit was assayed in several preparations containing known con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dotti C,Ceda GP,Denti L,Cavalieri S,Borasi G,Valenti G

    更新日期:1987-05-01 00:00:00

  • A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

    abstract::A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Riad-Fahmy D,Read GF,Gaskell SJ,Dyas J,Hindawi R

    更新日期:1979-05-01 00:00:00

  • A model for the effect of bias for cholesterol on the population at risk.

    abstract::The location of the Reference Value for an analyte within the population distribution affects the magnitude of error due to methodological bias. Using the gaussian distribution, we evaluated the effects of systematic and proportional biases of the method (positive and negative), mean value, and standard deviation on t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Ruddel M,Elin RJ

    更新日期:1988-11-01 00:00:00

  • Ten commercial kits compared for assay of thyrotropin in the normal and thyrotoxic range.

    abstract::I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly supe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Evans MC

    更新日期:1988-01-01 00:00:00

  • Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay.

    abstract::We have designed a re-usable dialysis cell and a complex dialysis buffer, with which undiluted serum samples can be dialyzed with minimal changes in their serum matrix. Dialysate thyroxin (free T4) is then measured by a sensitive RIA for T4. The range of reportability was 2-128 ng/L, the normal range was 8-27 ng/L, an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nelson JC,Tomei RT

    更新日期:1988-09-01 00:00:00

  • Clinical Correlations of Programmed Cell Death Ligand 1 Status in Liquid and Standard Biopsies in Breast Cancer.

    abstract:BACKGROUND:Data regarding the prognostic value of programmed cell death ligand 1 (PD-L1) expression on circulating tumor cells (CTCs) are lacking. However, CTCs could represent an alternative approach to serial biopsies, allowing real-time monitoring of cancer phenotype. METHODS:We evaluated, in a dedicated prospectiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa121

    authors: Jacot W,Mazel M,Mollevi C,Pouderoux S,D'Hondt V,Cayrefourcq L,Bourgier C,Boissiere-Michot F,Berrabah F,Lopez-Crapez E,Bidard FC,Viala M,Maudelonde T,Guiu S,Alix-Panabières C

    更新日期:2020-08-01 00:00:00

  • Statistical interpretation of concentrations of magnesium, zinc, calcium, potassium, cholesterols, and creatine kinase isoenzymes in men at different stages of ischemic heart disease.

    abstract::We present a statistical interpretation of plasma (Pl) and (or) erythrocyte (Erc) concentrations of magnesium, zinc, calcium, potassium, and total high-density lipoprotein (HDL) cholesterol, as well as of the activity of total creatine kinase (CK) and its CK-MB isoenzyme, in 26 men with pre-infarction syndrome (PIS) a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Speich M,Auget JL,Arnaud P

    更新日期:1989-05-01 00:00:00

  • Automated on-line solid-phase extraction coupled with HPLC for measurement of 5-hydroxyindole-3-acetic acid in urine.

    abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050062

    authors: Mulder EJ,Oosterloo-Duinkerken A,Anderson GM,De Vries EG,Minderaa RB,Kema IP

    更新日期:2005-09-01 00:00:00