Low bias in assayed values of lipoprotein antigens--lipoprotein(a) and apolipoproteins A-I and B--in midday postprandial blood specimens compared with morning fasting specimens.

Abstract:

:Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these biases, other major factors must be implicated for Lp(a) and apo B. Even after dilutional effects are controlled for, assayed values of Lp(a) are 11-13% lower, and assayed values of apo B are 8-9% lower, in postprandial specimens than in fasting specimens. Therefore, the time of collection of a blood sample relative to the last meal can significantly affect assayed values of lipoprotein antigens. Further studies are needed to determine whether these observations result from a physiological sequestering of lipoproteins in the postprandial state or from negative interferences affecting the assays of lipoprotein antigens.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Emancipator K

subject

Has Abstract

pub_date

1992-03-01 00:00:00

pages

431-3

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

38

pub_type

杂志文章
  • Quantification of integrated HIV DNA by repetitive-sampling Alu-HIV PCR on the basis of poisson statistics.

    abstract:BACKGROUND:Quantification of integrated proviral HIV DNA by repetitive-sampling Alu-HIV PCR is a candidate virological tool to monitor the HIV reservoir in patients. However, the experimental procedures and data analysis of the assay are complex and hinder its widespread use. Here, we provide an improved and simplified...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.219378

    authors: De Spiegelaere W,Malatinkova E,Lynch L,Van Nieuwerburgh F,Messiaen P,O'Doherty U,Vandekerckhove L

    更新日期:2014-06-01 00:00:00

  • Evaluation of a fully automated serum assay for C-terminal cross-linking telopeptide of type I collagen in osteoporosis.

    abstract:BACKGROUND:Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-da...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garnero P,Borel O,Delmas PD

    更新日期:2001-04-01 00:00:00

  • Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

    abstract::We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mahoney JJ,Wong RJ,Van Kessel AL

    更新日期:1993-05-01 00:00:00

  • Utility of the amino-terminal fragment of pro-brain natriuretic peptide in plasma for the evaluation of cardiac dysfunction in elderly patients in primary health care.

    abstract:BACKGROUND:The aims of this study were to measure the N-terminal fragment of pro-brain natriuretic peptide (proBNP) in plasma in medical conditions commonly found in primary care and to evaluate the utility of these measurements in identifying impaired cardiac function in elderly patients with symptoms associated with ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.8.1337

    authors: Alehagen U,Lindstedt G,Eriksson H,Dahlström U

    更新日期:2003-08-01 00:00:00

  • Interference of fetal hemoglobin with the spectrophotometric measurement of carboxyhemoglobin.

    abstract::We measured the concentration of carboxyhemoglobin (HbCO) in blood samples from 32 neonates by spectrophotometry (IL282 CO-Oximeter) and gas chromatography, finding a strong positive correlation (r = 0.89) between the concentration of fetal hemoglobin (Hb F) and HbCO as measured by spectrophotometry, but not by gas ch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vreman HJ,Ronquillo RB,Ariagno RL,Schwartz HC,Stevenson DK

    更新日期:1988-05-01 00:00:00

  • Association between SARS-CoV-2 neutralizing antibodies and commercial serological assays.

    abstract:INTRODUCTION:Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. METHODS:67 speci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa211

    authors: Tang MS,Case JB,Franks CE,Chen RE,Anderson NW,Henderson JP,Diamond MS,Gronowski AM,Farnsworth CW

    更新日期:2020-09-07 00:00:00

  • CEDIA, a new homogeneous immunoassay system.

    abstract::Genetic engineering of beta-galactosidase (EC 3.2.1.23) has led to the development of a new homogeneous assay system, CEDIA. The Z gene of the lac operon of Escherichia coli encodes a large enzymatically inactive polypeptide that spontaneously aggregates and folds to form active beta-galactosidase. Using recombinant D...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Henderson DR,Friedman SB,Harris JD,Manning WB,Zoccoli MA

    更新日期:1986-09-01 00:00:00

  • More sensitive flameless atomic absorption analysis of vanadium in tissue and serum.

    abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stroop SD,Helinek G,Greene HL

    更新日期:1982-01-01 00:00:00

  • C-reactive protein uptake by macrophage cell line via class-A scavenger receptor.

    abstract:BACKGROUND:C-reactive protein (CRP) increases in response to inflammation and is purported to be a risk factor for atherogenesis. We recently demonstrated that a scavenger receptor, lectin-like oxidized LDL receptor (LOX-1), is a receptor for CRP. In light of the overlapping ligand spectrum of scavenger receptors such ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140202

    authors: Fujita Y,Kakino A,Harada-Shiba M,Sato Y,Otsui K,Yoshimoto R,Sawamura T

    更新日期:2010-03-01 00:00:00

  • Low proportions of glycosylated hemoglobin associated with hemoglobin S and hemoglobin C.

    abstract::Using a cation-exchange chromatographic method, we found normal or subnormal values for glycosylated hemoglobin in a few diabetic patients with persistent hyperglycemia. Subsequent investigations revealed that these unexpected results had originated from black patients with diabetes. In view of common occurrence of ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aleyassine H

    更新日期:1979-08-01 00:00:00

  • Hyperhomocysteinemia and myocardial expression of brain natriuretic peptide in rats.

    abstract:BACKGROUND:Hyperhomocysteinemia (HHcy) has been linked to impaired left ventricular function and clinical class in patients with chronic heart failure. We hypothesized that HHcy stimulates myocardial brain natriuretic peptide (BNP) expression and induces adverse left ventricular remodeling. METHODS:We randomized 50 ra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077859

    authors: Herrmann M,Taban-Shoma O,Hübner U,Pexa A,Kilter H,Umanskaya N,Straub RH,Böhm M,Herrmann W

    更新日期:2007-04-01 00:00:00

  • Determinants of plasma methylmalonic acid in a large population: implications for assessment of vitamin B12 status.

    abstract:BACKGROUND:Methylmalonic acid (MMA) in plasma or serum is widely used for assessment of vitamin B(12) status. However, data are sparse regarding factors, besides renal function, that may influence MMA concentrations. We searched for important determinants of plasma MMA in the general population. METHODS:In 6946 middle...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.128678

    authors: Vogiatzoglou A,Oulhaj A,Smith AD,Nurk E,Drevon CA,Ueland PM,Vollset SE,Tell GS,Refsum H

    更新日期:2009-12-01 00:00:00

  • Electrophoretic patterns for serum glycoproteins reflect the presence of human breast cancer.

    abstract::We describe a group of glycoproteins that are synthesized and released by human breast tumors maintained in organ culture and similar glycoproteins released by a human breast carcinoma cell line (BT-20). The electrophoretic mobility of these glycoproteins on cellulose acetate is consistent with increased glycoprotein-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Tökes ZA

    更新日期:1977-11-01 00:00:00

  • Automated on-line solid-phase extraction coupled with HPLC for measurement of 5-hydroxyindole-3-acetic acid in urine.

    abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050062

    authors: Mulder EJ,Oosterloo-Duinkerken A,Anderson GM,De Vries EG,Minderaa RB,Kema IP

    更新日期:2005-09-01 00:00:00

  • Free erythrocyte porphyrins in the detection of undue absorption of Pb and of Fe deficiency.

    abstract::A fluorometric assay for free erythrocyte porphyrins (FEP) is described in detail, the direct test being used for the analysis of blood specimens collected with anticoagulants and the spot test for analysis of blood specimens collected on filter paper. A method for determining the amount of blood absorbed by different...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piomelli S

    更新日期:1977-02-01 00:00:00

  • Liquid-phase reactions started by rehydrating lyophilized reagents in a centrifugal analyzer.

    abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Truchaud A,Glikmanas G,Gourmelin Y,Hersant J,Trepo D,Foray G,Collombel C

    更新日期:1985-09-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Addition of triglyceride to serum for use in quality control and reference.

    abstract::We describe a simple method in which a water-soluble mixture of triocatanoin and a surfactant, "Triton X-114," are used in preparing solutions of triglycerides (triacylglycerols) in either human serum, solutions of albumin, or water. Analytical recovery added triglyceride was quantitative by two methods. The addition ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bonderman DP,Proksch GJ,Bonderman PW

    更新日期:1976-08-01 00:00:00

  • Alternatives to radioimmunoassay: labels and methods.

    abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Schall RF Jr,Tenoso HJ

    更新日期:1981-07-01 00:00:00

  • Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.

    abstract::In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Watanabe N,Kamei S,Ohkubo A,Yamanaka M,Ohsawa S,Makino K,Tokuda K

    更新日期:1986-08-01 00:00:00

  • Quantification of desferrioxamine in blood plasma by inductively coupled plasma atomic emission spectrometry.

    abstract::A sensitive method, inductively coupled plasma atomic emission spectroscopy, is used to measure desferrioxamine in blood plasma. The desferrioxamine is transformed into its iron chelate, ferrioxamine, which is extracted into benzyl alcohol, then re-extracted into HCl (0.5 mol/L), which is used as the sample for the sp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bourdon S,Houzé P,Bourdon R

    更新日期:1987-01-01 00:00:00

  • Micro-quantity tissue digestion for metal measurements by use of a microwave acid-digestion bomb.

    abstract::We describe a simple and convenient method for processing small amounts of tissue samples for trace-metal measurements by atomic absorption spectrometry, by use of a modified Parr microwave digestion bomb. Digestion proceeds rapidly (less than or equal to 90 s) in a sealed Teflon-lined vessel that eliminates contamina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nicholson JR,Savory MG,Savory J,Wills MR

    更新日期:1989-03-01 00:00:00

  • Enzymatic determination of serum urea on the surface of silicone-rubber pads.

    abstract::An enzymatic, fluorometric method is described for determination of serum urea on silicone-rubber pads. In this method, the reagents are lyophilized on the surface of the pads, NADH on one side and a mixture of urease, glutamate dehydrogenase, and alpha-ketoglutarate on the other. The rate of disappearance of NADH flu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuan JC,Lau KY,Guilbault GG

    更新日期:1975-01-01 00:00:00

  • Flash-heater ethylation of some antiepileptic drugs.

    abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friel P,Troupin AS

    更新日期:1975-05-01 00:00:00

  • Factor V Leiden and other coagulation factor mutations affecting thrombotic risk.

    abstract::Five genetic defects have been established as risk factors for venous thrombosis. Three are protein C, protein S, and antithrombin deficiencies, defects in the anticoagulant pathways of blood coagulation. Together they can be found in approximately 15% of families with inherited thrombophilia. Their laboratory diagnos...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bertina RM

    更新日期:1997-09-01 00:00:00

  • Increases of cardiac troponin in conditions other than acute coronary syndrome and heart failure.

    abstract:BACKGROUND:Although cardiac troponin (cTn) is a cornerstone marker in the assessment and management of patients with acute coronary syndrome (ACS) and heart failure (HF), cTn is not diagnostically specific for any single myocardial disease process. This narrative review discusses increases in cTn that result from acute...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2009.130799

    authors: Kelley WE,Januzzi JL,Christenson RH

    更新日期:2009-12-01 00:00:00

  • Simultaneous measurement of eight corticosteroids by liquid chromatography, and application of the procedure to diagnosis of congenital adrenal hyperplasia.

    abstract::We describe a liquid-chromatographic procedure for simultaneously determining eight steroids in serum. We used a Zorbax ODS column and a mobile phase of methanol/isopropanol/water (44/10/46, by vol), which well resolves the steroids cortisone, cortisol, corticosterone, 11-deoxycortisol, 11-deoxycorticosterone, androst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei JQ,Zhou XT,Wei JI

    更新日期:1987-08-01 00:00:00

  • Evolutionary changes in acute-phase proteins in alcoholic hepatocellular diseases.

    abstract::We studied the pattern of acute-phase proteins (orosomucoid, C-reactive protein, and haptoglobin) in hepatocellular deficiency due to chronic alcohol consumption, characterized by a decrease in serum transferrin concentration. We found that their patterns could vary independently of hepatocellular deficiency, but depe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Perier C,Chamson A,Engler R,Frey J

    更新日期:1983-01-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00