Interference of fetal hemoglobin with the spectrophotometric measurement of carboxyhemoglobin.

Abstract:

:We measured the concentration of carboxyhemoglobin (HbCO) in blood samples from 32 neonates by spectrophotometry (IL282 CO-Oximeter) and gas chromatography, finding a strong positive correlation (r = 0.89) between the concentration of fetal hemoglobin (Hb F) and HbCO as measured by spectrophotometry, but not by gas chromatography. Thus, Hb F interferes with the determination of HbCO by spectrophotometric techniques by falsely increasing apparent HbCO in direct proportion to Hb F. We conclude that, when Hb F is known or suspected to be present, blood HbCO cannot be reliably determined by methods based on spectrophotometry.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Vreman HJ,Ronquillo RB,Ariagno RL,Schwartz HC,Stevenson DK

subject

Has Abstract

pub_date

1988-05-01 00:00:00

pages

975-7

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

34

pub_type

杂志文章
  • Use of blood specimens collected on filter paper in screening for abnormal hemoglobins.

    abstract::Both cellulose acetate electrophoresis and citrate agar electrophoresis were performed on 834 blood samples collected on filter paper in Jamaica and shipped for testing to the National Hemoglobinopathy Standardization Laboratory at the U.S. National Center for Disease Control. Additionally, 30 blood samples collected ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schmidt RM,Brosious EM,Holland S,Wright JM,Serjeant GR

    更新日期:1976-05-01 00:00:00

  • Two-site enzyme immunoassay of CD4 and CD8 molecules on the surface of T lymphocytes from healthy subjects and HIV-1-infected patients.

    abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Carriere D,Fontaine C,Berthier AM,Rouquette AM,Carayon P,Laprode M,Juillard R,Jansen A,Paoli P,Paolucci F

    更新日期:1994-01-01 00:00:00

  • Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations.

    abstract:BACKGROUND:Specific gravity (SG) may perform as well as creatinine (CR) correction for adjusting urinary hormone concentrations, as well as offer some advantages. We compared the two methods and applied them to US and Bangladeshi specimens to evaluate their use in different populations. METHODS:Pearson correlations be...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.032292

    authors: Miller RC,Brindle E,Holman DJ,Shofer J,Klein NA,Soules MR,O'Connor KA

    更新日期:2004-05-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Utility of oligonucleotide array-based comparative genomic hybridization for detection of target gene deletions.

    abstract:BACKGROUND:direct DNA sequencing is the primary clinical technique for identifying mutations in human disease, but sequencing often does not detect intragenic or whole-gene deletions. Oligonucleotide array-based comparative genomic hybridization (CGH) is currently in clinical use to detect major changes in chromosomal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103721

    authors: Wong LJ,Dimmock D,Geraghty MT,Quan R,Lichter-Konecki U,Wang J,Brundage EK,Scaglia F,Chinault AC

    更新日期:2008-07-01 00:00:00

  • Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function ChemFET integrated-circuit sensor.

    abstract::On-line, simultaneous measurement of blood K+, Ca2+, Na+, and pH has been achieved by using a quadruple-function ChemFET (chemical-sensitive field-effect transistor) integrated-circuit sensor. Blood is withdrawn from the subject through an actively heparinized, dual-lumen cannula and passed into a flow-cell containing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sibbald A,Covington AK,Carter RF

    更新日期:1984-01-01 00:00:00

  • Effect of carbon cup aging on plasma zinc determination by flameless atomic adosorption spectrometry.

    abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chooi MK,Todd JK,Boyd ND

    更新日期:1975-04-01 00:00:00

  • Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation.

    abstract::Noninvasive monitoring of blood/tissue glucose concentrations has been successfully accomplished in individual diabetic subjects by using near-infrared (NIR) spectroscopy coupled with chemometric methods. Three different spectrometer configurations were tested: a) a Fourier-transform infrared spectrometer with an indi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson MR,Eaton RP,Haaland DM,Koepp GW,Thomas EV,Stallard BR,Robinson PL

    更新日期:1992-09-01 00:00:00

  • Acyclic adenine nucleoside phosphonates in plasma determined by high-performance liquid chromatography with fluorescence detection.

    abstract::9-(2-Phosphonylmethoxyethyl)adenine (PMEA), (S)-9-(3-hydroxy-2-phosphonylmethoxypropyl)adenine (HPMPA), and (R,S)-9-(3-fluoro-2-phosphonylmethoxypropyl)adenine (FPMPA) are selective antiviral agents with activity against a broad spectrum of DNA viruses and retroviruses. A highly sensitive method has been developed to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Naesens L,Balzarini J,De Clercq E

    更新日期:1992-04-01 00:00:00

  • Planar Functionalized Surfaces for Direct Immunoaffinity Desorption/Ionization Mass Spectrometry.

    abstract:BACKGROUND:Recent studies show that the haptoglobin phenotype in individuals with diabetes mellitus is an important factor for predicting the risk of myocardial infarction, cardiovascular death, and stroke. Current methods for haptoglobin phenotyping include PCR and gel electrophoresis. A need exists for a reliable met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244004

    authors: Pompach P,Nováková J,Kavan D,Benada O,Růžička V,Volný M,Novák P

    更新日期:2016-01-01 00:00:00

  • Fluorometric assay for phospholipase A2 in serum.

    abstract::In this fluorometric assay for phospholipase A2 (EC 3.1.1.4) in serum we use the fluorescent phospholipid analog 1-octacosanyl-2-(pyren-1-yl)hexanoyl-sn-glycero-3-phosphatid yl monomethyl ester as substrate. The optimized conditions are: 28 mumol of the substrate per liter of Tris buffer (20 mmol/L, pH 7.4). The hydro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thuren T,Virtanen JA,Lalla M,Kinnunen PK

    更新日期:1985-05-01 00:00:00

  • Hyperglycosylated human chorionic gonadotropin in serum of testicular cancer patients.

    abstract:BACKGROUND:Hyperglycosylated human chorionic gonadotropin (hCG-h) contains larger and more complex carbohydrate chains than regular human chorionic gonadotropin (hCG). hCG-h is thought to be the major form of hCG produced by testicular cancers and it has been suggested to play a key role in tumor invasion, but studies ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.183723

    authors: Lempiäinen A,Hotakainen K,Blomqvist C,Alfthan H,Stenman UH

    更新日期:2012-07-01 00:00:00

  • Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

    abstract::We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Hershman JM

    更新日期:1986-06-01 00:00:00

  • Characterization of a new certified reference material for human cardiac troponin I.

    abstract:BACKGROUND:To address the continuing need for the standardization of clinical human cardiac troponin I (cTnI) assays, NIST, with the assistance of the AACC/IFCC Cardiac Troponin I Standardization Committee, has developed a new certified reference material, Standard Reference Material (SRM) 2921: Human Cardiac Troponin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051359

    authors: Bunk DM,Welch MJ

    更新日期:2006-02-01 00:00:00

  • Determination of cyclosporine concentrations with monoclonal antibodies.

    abstract::We measured cyclosporine in whole blood from normal volunteers administered single oral doses of the drug and from two renal-transplant patients on immunosuppressive maintenance therapy, by liquid chromatography (I) and by radioimmunoassay with use of nonspecific polyclonal (II), specific monoclonal (III), and nonspec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schran HF,Rosano TG,Hassell AE,Pell MA

    更新日期:1987-12-01 00:00:00

  • Cross reactions in radioimmunoassay: a mathematical model for correcting assay results, as exemplified by eliminating the interference of intact thyrotropin in an assay of its beta subunit.

    abstract::To correct the results of a radioimmunoassay for beta-thyrotropin (TSH) subunit by eliminating the proportion ascribable to intact TSH, we have devised a method that experimentally reproduces the conditions under which the interference develops. Beta-TSH subunit was assayed in several preparations containing known con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dotti C,Ceda GP,Denti L,Cavalieri S,Borasi G,Valenti G

    更新日期:1987-05-01 00:00:00

  • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC.

    abstract::Assays with different specificity are used for cyclosporin monitoring in clinical transplantation. A recent survey of 35 centers showed that 86% used immunoassays for cyclosporin A (CsA). In consensus documents the following performance criteria were recommended: (a) imprecision < or = 10% at 50 microg/L and < or = 5%...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schütz E,Svinarov D,Shipkova M,Niedmann PD,Armstrong VW,Wieland E,Oellerich M

    更新日期:1998-10-01 00:00:00

  • Rate nephelometric measurement of rheumatoid factor in serum.

    abstract::We describe the measurement of rheumatoid factor in human sera with a rate nephelometer. The National Reference Preparation for Rheumatoid Factors is used to calibrate the assay in International Units. We used Hyland Positive Control, Level I, as a secondary standard. The standard curve is exponential, but is linear w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Hicks MJ,Williams RJ,Hinlicky J,Lichti DA

    更新日期:1979-11-01 00:00:00

  • Clinical evaluation of the Triage analytic device for drugs-of-abuse testing.

    abstract::In the present clinical evaluation of Triage immunoassay for detection of drugs of abuse, we examined a possible connection between the laboratory skills of the personnel using it and the quality of analytical results; we also evaluated the degree of concordance between the Triage results and those obtained by an inst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de la Torre R,Domingo-Salvany A,Badia R,Gonzàlez G,McFarlane D,San L,Torrens M

    更新日期:1996-09-01 00:00:00

  • Detecting CFTR gene mutations by using primer oligo base extension and mass spectrometry.

    abstract::A new method for the reliable identification of localized variations in DNA by detection of associated diagnostic products with matrix-assisted laser desorption ionization time-of-flight mass spectrometry is described. The diagnostic products are generated by the primer oligo base extension (PROBE) reaction, which req...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Braun A,Little DP,Köster H

    更新日期:1997-07-01 00:00:00

  • Separation of bound and free ligand by ethacridine (Rivanol) in thyroxin radioimmunoassay.

    abstract::In this simple and low-cost radioimmunoassay (RIA) procedure for thyroxin (T4), ethacridine (6,9-diamino-2-ethoxyacridine lactate; Rivanol) is used to separate antibody-bound ligand and free ligand. This acridine dye precipitates free T4 not bound to antibody. At pH 8.6, it precipitates more than 90% of 125I-labeled T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bhupal V,Mani RS

    更新日期:1983-11-01 00:00:00

  • Statistical evaluation of method-comparison data.

    abstract::Comparison of two methods for determining a substance is a common procedure in clinical chemistry. Almost without exception, normal theory statistics are used with the tacit assumption that the data under test show gaussian distributions. Experience has led us to question this assumption for populations of differences...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu GT,Twomey SL,Thiers RE

    更新日期:1975-03-01 00:00:00

  • Clinical and genetic correlates of growth differentiation factor 15 in the community.

    abstract:BACKGROUND:Growth differentiation factor 15 (GDF15), a stress-responsive cytokine produced in cardiovascular cells under conditions of inflammation and oxidative stress, is emerging as an important prognostic marker in individuals with and without existing cardiovascular disease (CVD). We therefore examined the clinica...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2012.190322

    authors: Ho JE,Mahajan A,Chen MH,Larson MG,McCabe EL,Ghorbani A,Cheng S,Johnson AD,Lindgren CM,Kempf T,Lind L,Ingelsson E,Vasan RS,Januzzi J,Wollert KC,Morris AP,Wang TJ

    更新日期:2012-11-01 00:00:00

  • Thin film biosensor for rapid visual detection of nucleic acid targets.

    abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ostroff RM,Hopkins D,Haeberli AB,Baouchi W,Polisky B

    更新日期:1999-09-01 00:00:00

  • Automated on-line solid-phase extraction coupled with HPLC for measurement of 5-hydroxyindole-3-acetic acid in urine.

    abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050062

    authors: Mulder EJ,Oosterloo-Duinkerken A,Anderson GM,De Vries EG,Minderaa RB,Kema IP

    更新日期:2005-09-01 00:00:00

  • Fully enzymatic method for determining 1,5-anhydro-D-glucitol in serum.

    abstract::We have developed a fully enzymatic method to measure 1,5 anhydro-D-glucitol (1,5-AG) in serum through use of pyranose oxidase (PROD: EC 1.1.3.10), glucokinase (EC 2.7.1.2), and an ATP-regenerating system. In a previous report (Clin Chem 1989;35:2039-43) the glucose interfering with the measurement of 1,5-AG was remov...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fukumura Y,Tajima S,Oshitani S,Ushijima Y,Kobayashi I,Hara F,Yamamoto S,Yabuuchi M

    更新日期:1994-11-01 00:00:00

  • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.

    abstract::We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bergqvist Y,Eckerbom S,Funding L

    更新日期:1984-03-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Utility of commonly used commercial human chorionic gonadotropin immunoassays in the diagnosis and management of trophoblastic diseases.

    abstract:BACKGROUND:Patients with trophoblastic diseases produce ordinary and irregular forms of human chorionic gonadotropin (hCG; e.g., nicked hCG, hCG missing the beta-subunit C-terminal segment, hyperglycosylated hCG, and free beta subunit) that are recognized to differing extents by automated immunometric hCG (or hCG beta)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cole LA,Shahabi S,Butler SA,Mitchell H,Newlands ES,Behrman HR,Verrill HL

    更新日期:2001-02-01 00:00:00

  • A tandem mass spectrometry triplex assay for the detection of Fabry, Pompe, and mucopolysaccharidosis-I (Hurler).

    abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.152009

    authors: Duffey TA,Bellamy G,Elliott S,Fox AC,Glass M,Turecek F,Gelb MH,Scott CR

    更新日期:2010-12-01 00:00:00