Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.

Abstract:

:In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, the chromogenicity of the gamma-globulins in this method is 70% of that of albumin, as estimated from results by a biuret method. Within-run CVs were less than 3.3%; the day-to-day CV was 2.9%. Errors due to interfering components in urine are less than 2%. The normal range for urinary protein as measured by this method was from 28 to 141 mg/day. Results by this method (y) and by a trichloroacetic acid-biuret method (x) correlated well (n = 80, r = 0.995; y = 0.99x - 2.9).

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Watanabe N,Kamei S,Ohkubo A,Yamanaka M,Ohsawa S,Makino K,Tokuda K

subject

Has Abstract

pub_date

1986-08-01 00:00:00

pages

1551-4

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

杂志文章
  • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.

    abstract::We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bergqvist Y,Eckerbom S,Funding L

    更新日期:1984-03-01 00:00:00

  • Erythrocyte folate analysis: saponin added during lysis of whole blood can increase apparent folate concentrations, depending on hemolysate pH.

    abstract:BACKGROUND:The analysis of red cell folate (RCF) depends on complete hemolysis of erythrocytes, and it is assumed that complete hemolysis is achieved by 10-fold dilution of whole blood with hypotonic solutions of 10 g/L ascorbic acid/ascorbate. This report challenges this assumption. METHODS:The conventional method of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wright AJ,Finglas PM,Southon S

    更新日期:2000-12-01 00:00:00

  • A method of assessing serum triiodothyronine concentrations that is independent of subject's age and variations in concentrations of binding proteins in serum.

    abstract::Pairs of values for serum triiodothyronine and serum triiodothyronine binding capacity were represented as maps of points for euthyroid populations (including subjects who were pregnant or were receiving estrogens) in the age groups 18-50, 51-64, 65-79, and greater than 80 years (504 subjects) and thyrotoxic populatio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mardell R,Gerson M

    更新日期:1978-10-01 00:00:00

  • Multi-wavelength analyses of second-derivative spectra for rapid determination of acetaminophen in serum.

    abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dingeon B,Charvin MA,Quenard MT,Thome H

    更新日期:1988-06-01 00:00:00

  • Fetuin-A is an independent predictor of death after ST-elevation myocardial infarction.

    abstract:BACKGROUND:Fetuin-A inhibits inflammation and has a protective effect against myocardial ischemia. Its deficiency has been found to be associated with cardiovascular death in patients with end-stage renal failure disease. We investigated the association between plasma fetuin-A and clinical outcome after ST-elevation ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.084947

    authors: Lim P,Collet JP,Moutereau S,Guigui N,Mitchell-Heggs L,Loric S,Bernard M,Benhamed S,Montalescot G,Randé JL,Guéret P

    更新日期:2007-10-01 00:00:00

  • Urinary cotinine and exposure to parental smoking in a population of children with asthma.

    abstract:BACKGROUND:Studies of the effects of tobacco smoke often rely on reported exposure to cigarette smoke, a measure that is subject to bias. We describe here the relationship between parental smoking exposure as assessed by urinary cotinine excretion and lung function in children with asthma. METHODS:We studied 90 childr...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Oddoze C,Dubus JC,Badier M,Thirion X,Pauli AM,Pastor J,Bruguerolle B

    更新日期:1999-04-01 00:00:00

  • Development of a chemiluminescence competitive PCR for the detection and quantification of parvovirus B19 DNA using a microplate luminometer.

    abstract:BACKGROUND:Quantitative PCR of viral nucleic acids can be useful clinically in diagnosis, risk assessment, and monitoring of antiviral therapy. We wished to develop a chemiluminescence competitive PCR (cPCR) for parvovirus B19. METHODS:Parvovirus DNA target sequences and competitor sequences were coamplified and direc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fini F,Gallinella G,Girotti S,Zerbini M,Musiani M

    更新日期:1999-09-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Progress toward ultrafast DNA sequencing using solid-state nanopores.

    abstract:BACKGROUND:Measurements of the ionic current flowing through nanometer-scale pores (nanopores) have been used to analyze single DNA and RNA molecules, with the ultimate goal of achieving ultrafast DNA sequencing. However, attempts at purely electronic measurements have not achieved the signal contrast required for sing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.091231

    authors: Soni GV,Meller A

    更新日期:2007-11-01 00:00:00

  • Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

    abstract:BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2012.195784

    authors: Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

    更新日期:2013-01-01 00:00:00

  • International normalized ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurements.

    abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lassen JF,Brandslund I,Antonsen S

    更新日期:1995-03-01 00:00:00

  • Low bias in assayed values of lipoprotein antigens--lipoprotein(a) and apolipoproteins A-I and B--in midday postprandial blood specimens compared with morning fasting specimens.

    abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Emancipator K

    更新日期:1992-03-01 00:00:00

  • The endocrinology of aging.

    abstract::Physiologic systems have substantial reserves in younger individuals. The process of aging and intercurrent pathologic processes gradually eliminate these reserves. Changes in endocrine systems, including menopause in women, androgen deficiency in men, loss of skeletal mass, decrease in growth hormone serum concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Perry HM 3rd

    更新日期:1999-08-01 00:00:00

  • Identification of chromosomally integrated human herpesvirus 6 by droplet digital PCR.

    abstract:BACKGROUND:Human herpesvirus 6 (HHV-6) latently infects a majority of adults. In about 1% of the population HHV-6 exists in a chromosomally integrated form (ciHHV-6) that resides in every somatic and germ cell and can be transmitted through the germ line. Patients with ciHHV-6 have been misdiagnosed and unnecessarily t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.217240

    authors: Sedlak RH,Cook L,Huang ML,Magaret A,Zerr DM,Boeckh M,Jerome KR

    更新日期:2014-05-01 00:00:00

  • Central role of zinc protoporphyrin in staging iron deficiency.

    abstract::In iron deficiency, zinc protoporphyrin (ZPP) is produced instead of heme, and the ZPP concentration in erythrocytes is increased (normal < or = 40 mumol/mol heme). We investigated the relevance of ZPP for staging iron deficiency. ZPP was determined by hematofluorometry in samples from 103 patients. Nineteen patients ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hastka J,Lasserre JJ,Schwarzbeck A,Hehlmann R

    更新日期:1994-05-01 00:00:00

  • Determination of inorganic arsenic and its organic metabolites in urine by flow-injection hydride generation atomic absorption spectrometry.

    abstract::A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first se...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hanna CP,Tyson JF,McIntosh S

    更新日期:1993-08-01 00:00:00

  • Radioimmunoassay of metanephrine and normetanephrine for diagnosis of pheochromocytoma.

    abstract::Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immun...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iinuma K,Ikeda I,Ogihara T,Hashizume K,Kurata K,Kumahara Y

    更新日期:1986-10-01 00:00:00

  • Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

    abstract:BACKGROUND:The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.107508

    authors: Shaikh A,Seegmiller JC,Borland TM,Burns BE,Ladwig PM,Singh RJ,Kumar R,Larson TS,Lieske JC

    更新日期:2008-09-01 00:00:00

  • Reflectance digital matrix photometry.

    abstract::We have designed and constructed a digital matrix photometer for quantitative measurement of reflected light of small chromophoric areas or colored spots. The areas are divided conceptually into small subunits in which the reflected light is measured. This is done through stepwise scanning with a photodiode array. The...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-06-01 00:00:00

  • Differential patterns of bone turnover in relation to bone pain and disease extent in bone in cancer patients with skeletal metastases.

    abstract:BACKGROUND:The alteration of the bone microenvironment as a consequence of skeletal metastases is poorly understood. The aim of this study was to search for patterns of bone markers in relation to primary tumor type, bone pain, and number of sites involved in patients with bone metastases. METHODS:We studied 323 patie...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Berruti A,Dogliotti L,Gorzegno G,Torta M,Tampellini M,Tucci M,Cerutti S,Frezet MM,Stivanello M,Sacchetto G,Angeli A

    更新日期:1999-08-01 00:00:00

  • Planar Functionalized Surfaces for Direct Immunoaffinity Desorption/Ionization Mass Spectrometry.

    abstract:BACKGROUND:Recent studies show that the haptoglobin phenotype in individuals with diabetes mellitus is an important factor for predicting the risk of myocardial infarction, cardiovascular death, and stroke. Current methods for haptoglobin phenotyping include PCR and gel electrophoresis. A need exists for a reliable met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244004

    authors: Pompach P,Nováková J,Kavan D,Benada O,Růžička V,Volný M,Novák P

    更新日期:2016-01-01 00:00:00

  • Bioassay of thyroid-stimulating immunoglobulin in cryopreserved human thyroid cells: optimization and clinical evaluation.

    abstract::We have explored the method of Rapoport et al. (J Clin Endocrinol Metab 1984;58:332-8) for the bioassay of thyroid-stimulating immunoglobulin (TSI) in cultured human thyroid cells, to optimize the assay and to evaluate its utility in clinical diagnosis and management of patients with autoimmune thyroid disease. Here w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kraiem Z,Glaser B,Pauker J,Sadeh O,Sheinfeld M

    更新日期:1988-02-01 00:00:00

  • Serum gentamicin assay by high-performance liquid chromatography.

    abstract::We describe a high-performance liquid chromatographic method for the quantitative determination of gentamicin in serum. The antibiotic was separated from serum by passage through a silicic acid column, derivatized with o-phthalaldehyde, and eluted with ethanol. The derivatized gentamicin was then separated into all th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maitra SK,Yoshikawa TT,Hansen JL,Nilsson-Ehle I,Palin WJ,Schotz MC,Guze LB

    更新日期:1977-12-01 00:00:00

  • Evaluation of homogeneous enzyme immunoassay of serum thyroxine with use of bichromatic analysis.

    abstract::We evaluated the homogeneous enzyme immunoassay ("EMIT") of serum thyroxine with use of an ABA- 100 Bichromatic Analyzer, modified with an auxiliary dispenser syringe and a dual probe assembly. The modification allows two reagents to be dispensed at one time. The sera must be pre-treated with 0.1 mol/liter NaOH. The p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Williams RJ

    更新日期:1978-01-01 00:00:00

  • Induced gene transcription: implications for biomarkers.

    abstract::Numerous xenobiotics regulate cellular functions by altering transcription of target genes. Use of sensitive and specific biomarkers based on gene transcript levels may help clarify the shape of the dose-response curve in the low-dose region associated with human exposures to environmental concentrations of chemicals....

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Sewall CH,Bell DA,Clark GC,Tritscher AM,Tully DB,Vanden Heuvel J,Lucier GW

    更新日期:1995-12-01 00:00:00

  • LOX index, a novel predictive biochemical marker for coronary heart disease and stroke.

    abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140707

    authors: Inoue N,Okamura T,Kokubo Y,Fujita Y,Sato Y,Nakanishi M,Yanagida K,Kakino A,Iwamoto S,Watanabe M,Ogura S,Otsui K,Matsuda H,Uchida K,Yoshimoto R,Sawamura T

    更新日期:2010-04-01 00:00:00

  • Diagnostic accuracy of pancreatic enzymes evaluated by use of multivariate data analysis.

    abstract::We analyzed pancreatic enzyme data from 508 patients with suspected pancreatitis by neural network analysis, by an Expert multirule generation protocol, and by receiver-operator characteristic (ROC) curve analysis of a single test result. Neural network analysis showed that use of lipase provided the best means for di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazmierczak SC,Catrou PG,Van Lente F

    更新日期:1993-09-01 00:00:00

  • Quantification of bone alkaline phosphatase in serum by precipitation with wheat-germ lectin: a simplified method and its clinical plausibility.

    abstract::We report an easy, rapid method for quantifying bone isoenzyme of alkaline phosphatase (EC 3.1.3.1., ALP) in serum. The original method described by Rosalki and Ying Foo (Clin Chem 1984;30:1182-6) was somewhat simplified. In contrast to their results, we found that bone ALP is precipitated quantitatively by wheat-germ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Behr W,Barnert J

    更新日期:1986-10-01 00:00:00

  • Evaluation of the lysosome-associated membrane protein LAMP-2 as a marker for lysosomal storage disorders.

    abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hua CT,Hopwood JJ,Carlsson SR,Harris RJ,Meikle PJ

    更新日期:1998-10-01 00:00:00

  • Diagnostic value of thyrotropin concentrations in serum as measured by a sensitive immunoradiometric assay.

    abstract::A new, highly sensitive immunoradiometric thyrotropin (TSH) assay involving solid-phase-coupled monoclonal antibodies (Boots-Celltech Sucrosep IRMA-TSH) has been evaluated in a wide variety of patients with thyroidal and nonthyroidal illnesses and the results compared with those obtained by conventional diagnostic TSH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bassett F,Eastman CJ,Ma G,Maberly GF,Smith HC

    更新日期:1986-03-01 00:00:00