Quantification of bone alkaline phosphatase in serum by precipitation with wheat-germ lectin: a simplified method and its clinical plausibility.

Abstract:

:We report an easy, rapid method for quantifying bone isoenzyme of alkaline phosphatase (EC 3.1.3.1., ALP) in serum. The original method described by Rosalki and Ying Foo (Clin Chem 1984;30:1182-6) was somewhat simplified. In contrast to their results, we found that bone ALP is precipitated quantitatively by wheat-germ lectin. To check the clinical plausibility of the method, we used samples from several comparison groups (blood donors, children, pregnant women, patients with neoplasms but without skeletal involvement) and a large number of patients suffering from bone diseases and diseases of the liver and biliary tree. Measured activities of bone ALP nearly always correlated with the clinical diagnosis. Only patients with hepatitis often had pathological bone activities not in accord with the other findings. Possible reasons for this observation are discussed.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Behr W,Barnert J

subject

Has Abstract

pub_date

1986-10-01 00:00:00

pages

1960-6

issue

10

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

杂志文章
  • Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

    abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simon M,Cuan J

    更新日期:1980-11-01 00:00:00

  • Serum prostate-specific acid phosphatase: development and validation of a specific radioimmunoassay.

    abstract::We describe radioimmunoassay for human prostatic acid phosphatase [orthophosphoric-monoester phospho-hydrolase (acid optimum), EC 3.1.3.2] in serum, with use of monospecific antisera raised in rabbits against highly purified acid phosphatase from human prostates. The antiserum did not cross react with partly purified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vihko P,Sajanti E,Jänne O,Peltonen L,Vihko R

    更新日期:1978-11-01 00:00:00

  • Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.

    abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ohkubo A,Kamei S,Yamanaka M,Arai F,Kitajima M,Kondo A

    更新日期:1981-07-01 00:00:00

  • Correlation of antemortem serum creatine kinase, creatine kinase-MB, troponin I, and troponin T with cardiac pathology.

    abstract:BACKGROUND:Spurious increases in serum troponins, especially troponin T, have been reported in patients with and without acute myocardial syndromes. METHODS:We studied 78 autopsied patients without clinical myocardial infarction (MI) and correlated histologic cardiac findings with antemortem serum creatine kinase (CK)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ooi DS,Isotalo PA,Veinot JP

    更新日期:2000-03-01 00:00:00

  • Measurement of different forms of tissue plasminogen activator in plasma.

    abstract:BACKGROUND:We evaluated assays to measure both total tissue plasminogen activator (tPA) and the three principle forms of tPA in plasma: active tPA, tPA complexed with plasminogen activator inhibitor type 1 (PAI-1), and tPA complexed with C1-inhibitor. METHODS:Active tPA was measured by use of an indirect amidolytic as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chandler WL,Jascur ML,Henderson PJ

    更新日期:2000-01-01 00:00:00

  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Interference of fetal hemoglobin with the spectrophotometric measurement of carboxyhemoglobin.

    abstract::We measured the concentration of carboxyhemoglobin (HbCO) in blood samples from 32 neonates by spectrophotometry (IL282 CO-Oximeter) and gas chromatography, finding a strong positive correlation (r = 0.89) between the concentration of fetal hemoglobin (Hb F) and HbCO as measured by spectrophotometry, but not by gas ch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vreman HJ,Ronquillo RB,Ariagno RL,Schwartz HC,Stevenson DK

    更新日期:1988-05-01 00:00:00

  • Detection of alkaline phosphatase/immunoglobulin complexes.

    abstract::We report another patient with a circulating alkaline phosphatase/immunoglobulin complex in his blood, and describe a simple method of demonstrating such complexes. On electrophoresis on cellulose acetate, the complex was relatively slow moving and there was no activity in the normal bone/liver isoenzyme region. When ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buttery JE,Milner CR,Nenadovic P,Pannall PR

    更新日期:1980-10-01 00:00:00

  • Detergent extraction and enzymatic analysis for fecal long-chain fatty acids, triglycerides, and cholesterol.

    abstract::We report a procedure for determining fecal long-chain fatty acids (LCFA), triglycerides, and cholesterol after detergent extraction with 10 mL/L Triton X-100, 6 mL/L Brij 30, and 0.1 mol/L HCl in isotonic saline by enzymatic analysis of the extraction supernates. Mean recoveries of calibrators ranged from 105% to 117...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lee MJ,Crook T,Noel C,Levinson UM

    更新日期:1994-12-01 00:00:00

  • Pre-renal azotemia mimicking chronic renal failure in a hypotensive patient.

    abstract::A 56-year-old Samoan man with a documented history of hypertension, who presented with atrial fibrillation and hypotension, quickly developed renal failure with a serum urea nitrogen of 1.370 g/L and a serum creatinine of 92 mg/L. After hydration of the patient, the creatinine value became normal in two days, the urea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Darm JR,Bhagavan NV,Scottolini AG

    更新日期:1979-11-01 00:00:00

  • The journey to regulation of protein-based multiplex quantitative assays.

    abstract:BACKGROUND:Clinical proteomics presents great promise in biology and medicine because of its potential for improving our understanding of diseases at the molecular level and for detecting disease-related biomarkers for diagnosis, prognosis, and prediction of therapeutic responses. To realize its full potential to impro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.156034

    authors: Boja ES,Jortani SA,Ritchie J,Hoofnagle AN,Težak Ž,Mansfield E,Keller P,Rivers RC,Rahbar A,Anderson NL,Srinivas P,Rodriguez H

    更新日期:2011-04-01 00:00:00

  • High-throughput genotyping of thiopurine S-methyltransferase by denaturing HPLC.

    abstract:BACKGROUND:The thiopurine S:-methyltransferase (TPMT) genetic polymorphism has a significant clinical impact on the toxicity of thiopurine drugs, which are used in the treatment of leukemia and as immunosuppressants. To date, 10 mutant alleles are known that are associated with intermediate or low TPMT activity. To fac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schaeffeler E,Lang T,Zanger UM,Eichelbaum M,Schwab M

    更新日期:2001-03-01 00:00:00

  • Circulating epithelial cells in patients with benign colon diseases.

    abstract:BACKGROUND:Detection of circulating tumor cells (CTCs) in the peripheral blood is a rapidly developing research field with clear clinical implications for the staging and monitoring of cancer patients. Current CTC assays, including the US Food and Drug Administration-cleared CellSearch® system, typically use markers [e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.175570

    authors: Pantel K,Denève E,Nocca D,Coffy A,Vendrell JP,Maudelonde T,Riethdorf S,Alix-Panabières C

    更新日期:2012-05-01 00:00:00

  • Gas-chromatographic profiling of urinary acidic and alcoholic catecholamine metabolites.

    abstract::Urinary acidic and alcoholic catecholamine metabolites were isolated separately from 24-h urines by simple extraction procedures. After derivatization, extracts were analyzed by means of simultaneous gas chromatography on two different stationary phases. The quality of the assay was checked by running "normal" and enr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Fremouw-Ottevangers DC,Wolthers BG,Vries JA

    更新日期:1977-05-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Cobalamin-binding capacity of haptocorrin and transcobalamin: age-correlated reference intervals and values from patients.

    abstract::Unsaturated cobalamin-binding capacity in plasma (P-UBBC) is determined by use of a silica gel (QUSO G32) to separate haptocorrin (P-ApoHC) and transcobalamin (P-ApoTC). The method is sensitive and precise: detection limit 13 pmol/L, interassay coefficients of variation 3% for P-UBBC (mean = 1080 pmol/L), 4% for P-Apo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gimsing P,Nexø E

    更新日期:1989-07-01 00:00:00

  • Determination of 5-hydroxytryptophan in plasma by high-performance liquid chromatography and fluorometric detection after phthaldialdehyde reaction.

    abstract::We describe the sensitive and precise determination 5-hydroxytryptophan in plasma from patients treated with this compound. The method is based on solvent extraction of plasma, high-performance liquid chromatography and continuous fluorometric detection after reaction with phthaldialdehyde in strong acid. The combined...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Enbaek F,Magnussen I

    更新日期:1978-02-01 00:00:00

  • Rapid, simple, and sensitive immunoagglutination assay with SiO2 particles and quartz crystal microbalance for quantifying Schistosoma japonicum antibodies.

    abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071555

    authors: Wang H,Zhang Y,Yan B,Liu L,Wang S,Shen G,Yu R

    更新日期:2006-11-01 00:00:00

  • Measurement of elastase and cysteine proteinases in synovial fluid of patients with rheumatoid arthritis, sero-negative spondylarthropathies, and osteoarthritis.

    abstract::Synovial fluid samples were collected from 45 patients with rheumatoid arthritis, spondylarthropathy, or osteoarthritis, to study their content of elastase (EC 3.4.21.37) and of cysteine proteinases (EC 3.4.22.1, 3.4.22.15). We measured both elastase complexed with alpha 1-proteinase inhibitor and elastase activity to...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huet G,Flipo RM,Richet C,Thiebaut C,Demeyer D,Balduyck M,Duquesnoy B,Degand P

    更新日期:1992-09-01 00:00:00

  • New immunoenzymatic assay for human thyrotropin compared with two radioimmunoassays.

    abstract::We have evaluated a new immunoenzymatic assay for human thyrotropin involving three monoclonal antibodies (Abbott HTSH EIA) and compared the results with those of two conventional nonequilibrium double-antibody radioimmunoassay (RIA) methods: Clinical Assays' RIA and a research RIA (J Clin Endocrinol Metab 1975; 41:67...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Turner LF Jr,Hershman JM

    更新日期:1986-03-01 00:00:00

  • Isolation and characterization of myoglobin and its two major isoforms from sheep heart.

    abstract::We isolated myoglobin from sheep heart by homogenizing cardiac muscle in 70%-saturated ammonium sulfate, followed by chromatography on a column containing carboxymethyl(CM)-Sephadex gel. Two major isoforms of myoglobin, designated Mb 7.9 and Mb 8.1, were separated by chromatofocusing and were distinguished by their di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu JT,Pieper RK,Wu LH,Peters JL

    更新日期:1989-05-01 00:00:00

  • Enzyme-linked immunosorbent assay of apolipoprotein B in blood spotted onto filter paper, suitable for neonatal screening.

    abstract::This assay was developed to measure apolipoprotein (apo) B in blood samples spotted onto filter paper. The long-term aim is to detect young families with the dominantly inherited familial hypercholesterolemia, during current neonatal screening programs. The interassay CV was 5.6%, and apo B concentrations correlated c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang XL,Dudman NP,Wilcken DE

    更新日期:1989-06-01 00:00:00

  • Centrifugal analyzer determination of ascorbate in serum or urine with Fe3+/Ferrozine.

    abstract::Measurement of serum ascorbate may be useful in long-term population studies because of the possible influence of ascorbate on numerous physiological factors. We describe an automated method for determining ascorbate in serum and urine by using the reduction of ferric iron by ascorbate and the formation of a color bet...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Butts WC,Mulvihill HJ

    更新日期:1975-09-01 00:00:00

  • Improved separation of creatine kinase cardiac isoenzyme in serum by batch fractionation.

    abstract::I describe a simple, single-tube batch fractionation procedure for separating MM and MB isoenzymes of creatine kinase on a macroporous strong anion exchanger (AG MP-1, Bio-Rad Laboratories). The isoenzymes can be separated in less than 3 min, with a resulting dilution of the serum with no more than an equal volume of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morin LG

    更新日期:1976-01-01 00:00:00

  • Do enzymatic analyses of serum triglycerides really need blanking for free glycerol?

    abstract::Distributions of concentrations of free glycerol in clinical plasma obtained for triglyceride assay were compiled to determine the frequency with which increased concentrations of free glycerol posed a potential problem for clinical interpretation of triglyceride results. Clinical histories were studied in patients wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jessen RH,Dass CJ,Eckfeldt JH

    更新日期:1990-07-01 00:00:00

  • Virus-coated layer-by-layer colloids as a multiplex suspension array for the detection and quantification of virus-specific antibodies.

    abstract:BACKGROUND:Suspension array technology has surpassed ELISA for automated, simultaneous detection and quantification of soluble biomarkers such as virus-specific antibodies. We describe assays in which antigens are attached to a lipid bilayer surrounding color-coded particles. METHODS:We used layer-by-layer technology ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065789

    authors: Toellner L,Fischlechner M,Ferko B,Grabherr RM,Donath E

    更新日期:2006-08-01 00:00:00

  • Prospective Associations of Systemic and Urinary Choline Metabolites with Incident Type 2 Diabetes.

    abstract:BACKGROUND:Several compounds in the choline oxidation pathway are associated with insulin resistance and prevalent diabetes; however, prospective data are scarce.We explored the relationships between systemic and urinary choline-related metabolites and incident type 2 diabetes in an observational prospective study amon...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.250761

    authors: Svingen GF,Schartum-Hansen H,Pedersen ER,Ueland PM,Tell GS,Mellgren G,Njølstad PR,Seifert R,Strand E,Karlsson T,Nygård O

    更新日期:2016-05-01 00:00:00

  • Detection and characterization of blocking-type anti-acetylcholine receptor antibodies in sera from patients with myasthenia gravis.

    abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hara H,Hayashi K,Ohta K,Itoh N,Nishitani H,Ohta M

    更新日期:1993-10-01 00:00:00

  • Robotic chromatography: development and evaluation of automated instrumentation for assay of glycohemoglobin.

    abstract::The measurement of glycohemoglobin (GHb) by boronate affinity chromatography is useful in monitoring long-term glucose control in diabetic subjects. The inherent disadvantage of this method is the hands-on time required because the hemoglobin fractions are separated on individual disposable columns. To overcome this d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herold CD,Andree K,Herold DA,Felder RA

    更新日期:1993-01-01 00:00:00

  • Detection of hemoglobin-based oxygen carriers in human serum for doping analysis: confirmation by size-exclusion HPLC.

    abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026591

    authors: Varlet-Marie E,Ashenden M,Lasne F,Sicart MT,Marion B,de Ceaurriz J,Audran M

    更新日期:2004-04-01 00:00:00