Correlation of antemortem serum creatine kinase, creatine kinase-MB, troponin I, and troponin T with cardiac pathology.

Abstract:

BACKGROUND:Spurious increases in serum troponins, especially troponin T, have been reported in patients with and without acute myocardial syndromes. METHODS:We studied 78 autopsied patients without clinical myocardial infarction (MI) and correlated histologic cardiac findings with antemortem serum creatine kinase (CK), its MB isoenzyme (CK-MB), cardiac troponin I (cTnI), and cardiac troponin T (cTnT). RESULTS:There was no significant myocardial pathology in 15 patients. Cardiac pathologies were in five groups: scarring from previous MI or patchy ventricular fibrosis (n = 9), recent MI (n = 27), healing MI (n = 7), degenerative myocyte changes consistent with congestive heart failure (CHF; n = 12), and other cardiac pathologies (n = 8). The median concentrations in the five groups were not significantly different for either CK or CK-MB. Compared with the no-pathology group, only the MI group was significantly different for cTnI, and the MI and other pathology groups were significantly different for cTnT. For patients with MI, 22%, 19%, 48%, and 65% had increased CK, CK-MB, cTnI, and cTnT, respectively; for CHF and other cardiac pathologies combined, the percentages were 28%, 17%, 22%, and 50%. For patients with increased cTnI, 72% and 28% had MI and other myocardial pathologies, respectively; patients with increased cTnT had 64% and 36%, respectively. Patients without myocardial pathology had no increases in CK-MB, cTnI, or cTnT. CONCLUSIONS:All patients with increased serum CK-MB, cTnI, and cTnT had significant cardiac histologic changes. The second-generation cTnT assay appears to be a more sensitive indicator of MI and other myocardial pathologies than the cTnI assay used in this study.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Ooi DS,Isotalo PA,Veinot JP

subject

Has Abstract

pub_date

2000-03-01 00:00:00

pages

338-44

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

46

pub_type

杂志文章
  • Cardiac troponins I and T in patients with suspected acute coronary syndrome: a comparative study in a routine setting.

    abstract::We compared cardiac troponin I (cTnI), using Access, Sanofi Pasteur, and cardiac troponin T (cTnT), using Elecsys, Boehringer Mannheim, in the first two routine blood samplings in a routine panel of cardiac markers for the biochemical diagnostic evaluation of patients with symptoms of acute myocardial infarction (AMI)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hetland O,Dickstein K

    更新日期:1998-07-01 00:00:00

  • Use of myeloperoxidase for risk stratification in acute heart failure.

    abstract:BACKGROUND:Myeloperoxidase (MPO) is a biomarker of inflammation and oxidative stress produced by neutrophils, monocytes, and endothelial cells. Concentrations of MPO predict mortality in patients with chronic heart failure. This study sought to investigate the diagnostic accuracy and prognostic value of MPO in patients...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.142257

    authors: Reichlin T,Socrates T,Egli P,Potocki M,Breidthardt T,Arenja N,Meissner J,Noveanu M,Reiter M,Twerenbold R,Schaub N,Buser A,Mueller C

    更新日期:2010-06-01 00:00:00

  • Urothelial Carcinoma Detection Based on Copy Number Profiles of Urinary Cell-Free DNA by Shallow Whole-Genome Sequencing.

    abstract:BACKGROUND:Current noninvasive assays for urothelial carcinoma (UC) lack clinical sensitivity and specificity. Given the utility of plasma cell-free DNA (cfDNA) biomarkers, the development of urinary cfDNA biomarkers may improve the diagnostic sensitivity. METHODS:We assessed copy number alterations (CNAs) by shallow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.309633

    authors: Ge G,Peng D,Guan B,Zhou Y,Gong Y,Shi Y,Hao X,Xu Z,Qi J,Lu H,Zhang X,Zhan Y,Li Y,Wu Y,Ding G,Shen Q,He Q,Li X,Zhou L,Ci W

    更新日期:2020-01-01 00:00:00

  • Fructosamine Test-Plus, a modified fructosamine assay evaluated.

    abstract::We have evaluated Fructosamine Test-Plus, a commercial fructosamine assay based on the reduction of nitro-blue tetrazolium dye in alkaline buffer (Clin Chem 1985;31:1550-4), modified by including a detergent and uricase in the reagent, by changing the concentrations of buffer and dye, and by changing the approach to p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Baker J,Metcalf P,Scragg R,Johnson R

    更新日期:1991-04-01 00:00:00

  • Immunochemical detection of group I and group II phospholipases A2 in human serum.

    abstract::Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nevalainen TJ,Kortesuo PT,Rintala E,Märki F

    更新日期:1992-09-01 00:00:00

  • Description of a computer program to assess cancer antigen 15.3, carcinoembryonic antigen, and tissue polypeptide antigen information during monitoring of metastatic breast cancer.

    abstract::It is time-consuming to process and compare the clinical and marker information registered during monitoring of breast cancer patients. To facilitate the assessment, we developed a computer program for interpreting consecutive measurements. The intraindividual biological variation, the analytical precision profile, th...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Sölétormos G,Schiøler V

    更新日期:2000-08-01 00:00:00

  • Multi-channel, probe colorimeter for use with the micr-ELISA test, which makes use of disposable flat-bottom microhemagglutination plates.

    abstract::We describe a multiprobe colorimeter that permits the reading of enzyme-linked immunosorbent assays (ELISA) in situ, by use of microhemagglutination plates. The use of dipping probes eliminates interference from meniscus effects and air-bubble entrapment. Detailed validation tests have been done and potential sources ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McMurray CH,Blanchflower WJ

    更新日期:1979-04-01 00:00:00

  • Detection of apolipoprotein E variants by an oligonucleotide "melting" procedure.

    abstract::An oligonucleotide "melting" procedure was developed whereby we can monitor for a sequence heterogeneity in the gene for apolipoprotein E production. Two oligonucleotides were synthesized, one recognizing the common epsilon 3 allele but not the common epsilon 2 allele, the other recognizing the epsilon 2 allele but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Funke H,Rust S,Assmann G

    更新日期:1986-07-01 00:00:00

  • Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration.

    abstract:BACKGROUND:Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.176545

    authors: Heijboer AC,Blankenstein MA,Kema IP,Buijs MM

    更新日期:2012-03-01 00:00:00

  • Kromoscopic analysis: a possible alternative to spectroscopic analysis for noninvasive measurement of analytes in vivo.

    abstract::Light that penetrates scattering media shows nonlinearities that mask the broad and shallow perturbations made by trace analytes on the background illuminant spectrum. Narrow-band spectroscopic decomposition and deconvolution of such weak bands is a formidable analytical task that pushes the fundamentally linear spect...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sodickson LA,Block MJ

    更新日期:1994-09-01 00:00:00

  • Iron and total iron-binding capacity in serum of patients receiving iron-dextran: Kodak Ektachem methodologies, spectrophotometry, and atomic-absorption spectrometry compared.

    abstract::We compared the analytical performance of the Kodak Ektachem XR700 assays of iron (Fe) and total iron-binding capacity (TIBC) with that of a conventional ferrozine assay (performed with a Cobas-Bio) and occasionally with that of atomic-absorption spectrometry (AAS). The correlation was modest between Kodak and Cobas-B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vercammen M,Goedhuys W,Boeyckens A,De Roy R,Sennesael J,Sevens C,Gorus F

    更新日期:1990-10-01 00:00:00

  • Enzyme-linked immunosorbent choriomammotropin assay.

    abstract::We have devloped an enzyme-linked immunosorbent assay for determining choriomammotropin (human placental lactogen) in serum. Unlabeled hormone competes with choriomammotropin-beta-galactosidase conjugate for antibody bound to polystyrene tubes. The entire assay can be performed in 2.5 h with good precision. The coeffi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dittmar D,Monji N,Cid A,Malkus H,Castro A

    更新日期:1979-02-01 00:00:00

  • Enzyme-linked immunosorbent assay of apolipoprotein B in blood spotted onto filter paper, suitable for neonatal screening.

    abstract::This assay was developed to measure apolipoprotein (apo) B in blood samples spotted onto filter paper. The long-term aim is to detect young families with the dominantly inherited familial hypercholesterolemia, during current neonatal screening programs. The interassay CV was 5.6%, and apo B concentrations correlated c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang XL,Dudman NP,Wilcken DE

    更新日期:1989-06-01 00:00:00

  • Effect of stripping thyroxin from thyroxin-binding globulin on the measurement of free thyroxin in serum by equilibrium dialysis and by radioimmunoassay.

    abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakagawa T,Matsumura K,Takeda K,Shinoda N,Matsuda A,Matsushita T,Tagami T

    更新日期:1990-02-01 00:00:00

  • A direct radioimmunoassay for aldosterone in unextracted serum and plasma.

    abstract::We describe a novel radioimmunoassay procedure for the direct estimation of aldosterone in unextracted plasma and serum samples, in which interfering binding proteins are digested by Proteinase K (Tritirachium alkaline proteinase, EC 3.4.21.14), a powerful proteolytic enzyme. Heating at 75 degrees C for 15 min inactiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lee TP,Tan CH

    更新日期:1981-12-01 00:00:00

  • Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability.

    abstract::Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lott JA,Smith DA,Mitchell LC,Moeschberger ML

    更新日期:1996-06-01 00:00:00

  • Enzyme immunoassay for intact human insulin in serum or plasma.

    abstract::We describe an enzyme-linked two-site immunoassay for quantitation of intact insulin in human serum and plasma. The method uses two murine monoclonal antibodies that bind to two different epitopes on the insulin molecule. The immunoassay is specific. Human proinsulin is not bound by the antibodies, and the binding of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andersen L,Dinesen B,Jørgensen PN,Poulsen F,Røder ME

    更新日期:1993-04-01 00:00:00

  • Acyclic adenine nucleoside phosphonates in plasma determined by high-performance liquid chromatography with fluorescence detection.

    abstract::9-(2-Phosphonylmethoxyethyl)adenine (PMEA), (S)-9-(3-hydroxy-2-phosphonylmethoxypropyl)adenine (HPMPA), and (R,S)-9-(3-fluoro-2-phosphonylmethoxypropyl)adenine (FPMPA) are selective antiviral agents with activity against a broad spectrum of DNA viruses and retroviruses. A highly sensitive method has been developed to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Naesens L,Balzarini J,De Clercq E

    更新日期:1992-04-01 00:00:00

  • Comparison of urinary albumin quantification by immunoturbidimetry, competitive immunoassay, and protein-cleavage liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Increased urinary albumin excretion is a well-documented diagnostic and prognostic biomarker for renal disease. Urinary albumin is typically measured in clinical settings by immunoassay methods. However, neither a reference method nor a urine albumin calibration reference material is currently available. ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.129833

    authors: Seegmiller JC,Sviridov D,Larson TS,Borland TM,Hortin GL,Lieske JC

    更新日期:2009-11-01 00:00:00

  • Low bias in assayed values of lipoprotein antigens--lipoprotein(a) and apolipoproteins A-I and B--in midday postprandial blood specimens compared with morning fasting specimens.

    abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Emancipator K

    更新日期:1992-03-01 00:00:00

  • Copy number and expression alterations of miRNAs in the ovarian cancer cell line OVCAR-3: impact on kallikrein 6 protein expression.

    abstract:BACKGROUND:Kallikrein-related peptidase 6 (KLK6), a member of the serine protease family of kallikrein (KLK) genes, is dysregulated in ovarian carcinomas (OCa) and its overexpression is associated with poor prognosis. Regulation of its expression is poorly understood and is likely to be influenced by multiple mechanism...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.193060

    authors: Bayani J,Kuzmanov U,Saraon P,Fung WA,Soosaipillai A,Squire JA,Diamandis EP

    更新日期:2013-01-01 00:00:00

  • Variability in the relationship between mean plasma glucose and HbA1c: implications for the assessment of glycemic control.

    abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.079756

    authors: Kilpatrick ES,Rigby AS,Atkin SL

    更新日期:2007-05-01 00:00:00

  • C-reactive protein stimulates myeloperoxidase release from polymorphonuclear cells and monocytes: implications for acute coronary syndromes.

    abstract:BACKGROUND:C-reactive protein (CRP), the prototypic marker of inflammation, is present in atherosclerotic plaques and appears to promote atherogenesis. Also, CRP has been localized to monocytes and tissue macrophages, which are present in the necrotic core of lesions prone to plaque rupture. Leukocyte-derived myelopero...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.109207

    authors: Singh U,Devaraj S,Jialal I

    更新日期:2009-02-01 00:00:00

  • Two-site immunoenzymometric assay for the 52-kDa cathepsin D in cytosols of breast cancer tissues.

    abstract::We developed a solid-phase two-site immunoenzymometric assay (IEMA) of the estrogen-induced 52-kDa cathepsin D (EC 3.4.23.5) and its processed forms (48-kDa and 34-kDa proteins) in cytosols of breast cancer tissues, using two monoclonal antibodies directed against two different epitopes of these antigens. The first an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rogier H,Freiss G,Besse MG,Cavalié-Barthez G,Garcia M,Pau B,Rochefort H,Paolucci F

    更新日期:1989-01-01 00:00:00

  • Pre-renal azotemia mimicking chronic renal failure in a hypotensive patient.

    abstract::A 56-year-old Samoan man with a documented history of hypertension, who presented with atrial fibrillation and hypotension, quickly developed renal failure with a serum urea nitrogen of 1.370 g/L and a serum creatinine of 92 mg/L. After hydration of the patient, the creatinine value became normal in two days, the urea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Darm JR,Bhagavan NV,Scottolini AG

    更新日期:1979-11-01 00:00:00

  • Simple spectrophotometric determination of urinary albumin by dye-binding with use of bromphenol blue.

    abstract::This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schosinsky KH,Vargas M,Luz Esquivel A,Chavarria MA

    更新日期:1987-02-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

    abstract::We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Hershman JM

    更新日期:1986-06-01 00:00:00

  • Oligosaccharide analysis in urine by maldi-tof mass spectrometry for the diagnosis of lysosomal storage diseases.

    abstract:BACKGROUND:There are 45 known genetic diseases that impair the lysosomal degradation of macromolecules. The loss of a single lysosomal hydrolase leads to the accumulation of its undegraded substrates in tissues and increases of related glycoconjugates in urine, some of which can be detected by screening of free oligosa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.201053

    authors: Xia B,Asif G,Arthur L,Pervaiz MA,Li X,Liu R,Cummings RD,He M

    更新日期:2013-09-01 00:00:00

  • Development of a kinetic assay for band 5b tartrate-resistant acid phosphatase activity in serum.

    abstract:BACKGROUND:Band 5 tartrate-resistant acid phosphatase (TrACP; EC 3. 1.3.2) consists of two isoenzymes, bands 5a and 5b, of which band 5b TrACP is considered to be derived from bone. However, no kinetic method for the specific measurement of band 5b TrACP in serum is available. Our aim was to develop a kinetic assay met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakanishi M,Yoh K,Miura T,Ohasi T,Rai SK,Uchida K

    更新日期:2000-04-01 00:00:00