Fructosamine Test-Plus, a modified fructosamine assay evaluated.

Abstract:

:We have evaluated Fructosamine Test-Plus, a commercial fructosamine assay based on the reduction of nitro-blue tetrazolium dye in alkaline buffer (Clin Chem 1985;31:1550-4), modified by including a detergent and uricase in the reagent, by changing the concentrations of buffer and dye, and by changing the approach to primary calibration. Specimens were from 2321 participants in a health screening survey in a local workforce. Compared with the original fructosamine method, the Fructosamine Test-Plus method was less affected by protein concentration in the sample and less subject to interference from hyperlipidemia. The changes have also extended the linearity of the assay in the pathological range. However, as a screening method for diabetes mellitus in a population with a disease prevalence of 2.28%, the performance of Fructosamine Test-Plus was similar to the original assay.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Baker J,Metcalf P,Scragg R,Johnson R

subject

Has Abstract

pub_date

1991-04-01 00:00:00

pages

552-6

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

37

pub_type

杂志文章
  • Determinants of Vascular Age: An Epidemiological Perspective.

    abstract:BACKGROUND:Vascular age is an emerging health indicator and predictor of end-organ damage to the heart, brain, and kidney. Although there have been many review publications concerning risk factors for vascular aging, most include cross-sectional epidemiological studies, limiting inferences about temporality. There is a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.287623

    authors: Kucharska-Newton AM,Stoner L,Meyer ML

    更新日期:2019-01-01 00:00:00

  • Mechanized amidolytic technique for determination of factor X and factor-X antigen, and its application to patients being treated with oral anticoagulants.

    abstract::We describe a mechanized chromogenic assay for factor X, the results of which correlate well with those for the one-stage clotting assays for factor X in which it is activated either via the extrinsic pathway by thromboplastin or directly by Russell's viper venom. We purified human factor X and raised monospecific ant...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: van Wijk EM,Kahlé LH,ten Cate JW

    更新日期:1980-06-01 00:00:00

  • Rapid Zeeman atomic absorption determination of copper in serum and urine.

    abstract::In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang ST,Demshar HP

    更新日期:1993-09-01 00:00:00

  • Serum ionized calcium and corrected total calcium in borderline hyperparathyroidism.

    abstract::We studied 25 borderline-hyperparathyroidism patients whose total serum calcium concentration was within normal limits (reference range: 2.25--2.75 mmol/liter) but whose concentrations of serum ionized calcium were above normal (reference range: 1.03--1.23 mmol/liter). Their hyperparathyroidism was histopathologically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Larsson L,Ohman S

    更新日期:1978-11-01 00:00:00

  • Values for some serum analytes in high-risk infants, two days postpartum.

    abstract::Using a continuous-flow (Technicon SMAC) analyzer, we measured the concentration of 20 analytes in capillary blood sera from 149 neonates in an intensive-care unit. Included were term and pre-term babies, both groups with and without asphyxia. The values obtained, especially for those enzymes and analytes that are rel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fitzsimons EJ,Fletcher MA,Chakrin A

    更新日期:1984-04-01 00:00:00

  • Theoretical aspects of one-point calibration: causes and effects of some potential errors, and their dependence on concentration.

    abstract::The potential errors of the one-point calibration technique are described mathematically. I examine the theoretical causes and effects of analytical errors in absorbance and of errors in determining calibration concentration, and discuss techniques for minimizing their impact. The dependence of these errors on the cal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kemp GJ

    更新日期:1984-07-01 00:00:00

  • C-reactive protein uptake by macrophage cell line via class-A scavenger receptor.

    abstract:BACKGROUND:C-reactive protein (CRP) increases in response to inflammation and is purported to be a risk factor for atherogenesis. We recently demonstrated that a scavenger receptor, lectin-like oxidized LDL receptor (LOX-1), is a receptor for CRP. In light of the overlapping ligand spectrum of scavenger receptors such ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140202

    authors: Fujita Y,Kakino A,Harada-Shiba M,Sato Y,Otsui K,Yoshimoto R,Sawamura T

    更新日期:2010-03-01 00:00:00

  • Comparative Analysis of Biochemical Biases by Ligation- and Template-Switch-Based Small RNA Library Preparation Protocols.

    abstract:BACKGROUND:Small RNAs are key players in the regulation of gene expression and differentiation. However, many different classes of small RNAs (sRNAs) have been described with distinct biogenesis pathways and, as a result, with different biochemical properties. To analyze sRNAs by deep sequencing, complementary DNA synt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.305045

    authors: Meistertzheim M,Fehlmann T,Drews F,Pirritano M,Gasparoni G,Keller A,Simon M

    更新日期:2019-12-01 00:00:00

  • Clinical evaluation of a lead mobilization test using the chelating agent dimercaptosuccinic acid.

    abstract:BACKGROUND:The lead mobilization test reflects the mobilizable and likely toxicologically active fraction of the lead body burden. We propose a safe and convenient protocol for this test, to assess concomitant copper and zinc excretion and to determine the size of the chelatable lead pool in nonoccupationally exposed a...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.051128

    authors: Hoet P,Buchet JP,Decerf L,Lavalleye B,Haufroid V,Lison D

    更新日期:2006-01-01 00:00:00

  • Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

    abstract::We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson DH,Bogacz JP,Forsythe CM,Turk PJ,Lane TL,Gates RC,Brandt DR

    更新日期:1993-10-01 00:00:00

  • Effect of lyophilization on results of five enzymatic methods for cholesterol.

    abstract::We studied the effect of lyophilization of serum pools on the determination of cholesterol with the enzymatic methods used in five automated analyzers: SMAC (Technicon), the RA-1000 (Technicon), the aca (Du Pont), the TDx (Abbott), and the Ektachem 700P (Kodak). We prepared two serum pools: pool A (2.2 g/L) and pool B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Chesler R,Elin RJ

    更新日期:1989-07-01 00:00:00

  • Quantification of tau in cerebrospinal fluid by immunoaffinity enrichment and tandem mass spectrometry.

    abstract:BACKGROUND:Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.216515

    authors: McAvoy T,Lassman ME,Spellman DS,Ke Z,Howell BJ,Wong O,Zhu L,Tanen M,Struyk A,Laterza OF

    更新日期:2014-04-01 00:00:00

  • Recombinase Polymerase Amplification for Diagnostic Applications.

    abstract:BACKGROUND:First introduced in 2006, recombinase polymerase amplification (RPA) has stirred great interest, as evidenced by 75 publications as of October 2015, with 56 of them just in the last 2 years. The widespread adoption of this isothermal molecular tool in many diagnostic fields represents an affordable (approxim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.245829

    authors: Daher RK,Stewart G,Boissinot M,Bergeron MG

    更新日期:2016-07-01 00:00:00

  • The fiscal consequences of central vs distributed testing of glucose.

    abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkelman JW,Wybenga DR,Tanasijevic MJ

    更新日期:1994-08-01 00:00:00

  • The haptoglobin 2-2 phenotype affects serum markers of iron status in healthy males.

    abstract:BACKGROUND:Human iron status is influenced by environmental and genetic factors. We hypothesized that the genetic polymorphism of haptoglobin (Hp), a hemoglobin-binding plasma protein, could affect iron status. METHODS:Reference values of serum iron status markers were compared according to Hp phenotypes (Hp 1-1, Hp 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Langlois MR,Martin ME,Boelaert JR,Beaumont C,Taes YE,De Buyzere ML,Bernard DR,Neels HM,Delanghe JR

    更新日期:2000-10-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00

  • Automated homogeneous immunoassay for gentamicin on the dimension clinical chemistry system.

    abstract:BACKGROUND:Monitoring of the concentration of gentamicin in serum and plasma during therapy is widely recommended and practiced in hospitals. Our aim was to develop a homogeneous immunoassay based on particle-enhanced turbidimetric inhibition immunoassay technology to quantify gentamicin on the Dimension clinical chemi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wei TQ,Chu VP,Craig AR,Duffy JE,Obzansky DM,Kilgore D,Masulli IS,Sanders CM,Thompson JC

    更新日期:1999-03-01 00:00:00

  • Measurement of glycated protein by a rapid and specific method for absolute quantification of lysine-bound glucose.

    abstract::We modified the liquid-chromatographic assay of Schleicher and Wieland (J Clin Chem Clin Biochem 1981; 19:81-7) for measuring lysine-bound glucose in serum proteins, increasing its performance and practicality. After precipitating serum proteins from 10- to 50-microL samples with ethanol (700 mL/L) and hydrolyzing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Drexel H,Klocker H,Patsch JR,Breier C,Braunsteiner H

    更新日期:1987-09-01 00:00:00

  • A sensitive liquid-chromatographic method for determination of 3'-azido-3'-deoxythymidine (AZT) in plasma and urine.

    abstract::We describe a liquid-chromatographic assay for AZT in human plasma and urine. This assay involves the use of two internal standards, allowing reference of AZT peaks to the appropriate internal standard, the choice depending on the range of concentrations encountered. This method is isocratic, specific, sensitive enoug...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hedaya MA,Sawchuk RJ

    更新日期:1988-08-01 00:00:00

  • Interlaboratory/intermethod differences in functional sensitivity of immunometric assays of thyrotropin (TSH) and impact on reliability of measurement of subnormal concentrations of TSH.

    abstract::Clinically relevant interassay precision profiles for thyrotropin (thyroid-stimulating hormone; TSH) were constructed with human serum pools measured over 4-8 weeks by six immunometric assays, in at least two different reagent lots. Functional sensitivities (the concentration at which the interassay CV is < or = 20%) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Spencer CA,Takeuchi M,Kazarosyan M,MacKenzie F,Beckett GJ,Wilkinson E

    更新日期:1995-03-01 00:00:00

  • Tentacle Probes: differentiation of difficult single-nucleotide polymorphisms and deletions by presence or absence of a signal in real-time PCR.

    abstract:BACKGROUND:False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation dif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.091488

    authors: Satterfield BC,Kulesh DA,Norwood DA,Wasieloski LP Jr,Caplan MR,West JA

    更新日期:2007-12-01 00:00:00

  • A computerized classification technique for screening for the presence of breath biomarkers in lung cancer.

    abstract::A simple computer-based screening technique has been developed for classifying human expired air components into 16 chemical classes, based on empirical formulas. The sort procedure was developed to simplify the screening of the composition of expired air samples by sorting all components into chemical classes and cla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: O'Neill HJ,Gordon SM,O'Neill MH,Gibbons RD,Szidon JP

    更新日期:1988-08-01 00:00:00

  • New immunoenzymatic assay for human thyrotropin compared with two radioimmunoassays.

    abstract::We have evaluated a new immunoenzymatic assay for human thyrotropin involving three monoclonal antibodies (Abbott HTSH EIA) and compared the results with those of two conventional nonequilibrium double-antibody radioimmunoassay (RIA) methods: Clinical Assays' RIA and a research RIA (J Clin Endocrinol Metab 1975; 41:67...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Turner LF Jr,Hershman JM

    更新日期:1986-03-01 00:00:00

  • Comparison of two micromethods for determination of lipoprotein cholesterol in plasma.

    abstract::We compared the results obtained by a micromethod for the determination of plasma lipoprotein cholesterol, in which electrophoresis is used to separate the lipoprotein fractions (beta-, pre-beta-, and alpha-lipoproteins), with those determinations with ultracentrifugation (low-density, very-low-density, and high-densi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kupke IR,Zeugner S,Gottschalk A

    更新日期:1979-10-01 00:00:00

  • A two-step radioimmunoassay for free triiodothyronine in serum.

    abstract::Using a high-affinity solid-phase-bound antibody (Ka = 1.2 X 10(11) L/mol), we have standardized a two-step radioimmunoassay for free triiodothyronine (FT3) in serum, based on immunoextraction. The method was validated by comparison with an equilibrium-dialysis procedure (r = 0.96) involving RIA of T3 in the dialysate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rajan MG,Samuel AM

    更新日期:1987-03-01 00:00:00

  • Improved HPLC method for carbohydrate-deficient transferrin in serum.

    abstract:BACKGROUND:There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms. METHODS:Transferrin was iron-saturated by mixing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.023341

    authors: Helander A,Husa A,Jeppsson JO

    更新日期:2003-11-01 00:00:00

  • Reflotron assays of alanine aminotransferase and gamma-glutamyltransferase in whole-blood samples evaluated.

    abstract::We evaluated the Reflotron (Boehringer Mannheim) system for measuring activities of alanine aminotransferase (EC 2.6.1.2) and gamma-glutamyltransferase (EC 2.3.2.2). Within- and between-day precision were comparable with conventional analytical methods. The linear range of the methods extended to more than 40-fold the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: James DR,Price CP

    更新日期:1987-06-01 00:00:00

  • Evaluation of the IFCC-recommended procedure for serum aspartate aminotransferase as modified for use with the centrifugal analyzer.

    abstract::The IFCC-recommended procedure for aspartate aminotransferase (EC 2.6.1.1) was adapted to the centrifugal analyzer and evaluated during five years. The main hindrance to widespread use of the recommended method is the need for pre-incubation with pyridoxal phosphate. The present method includes a 10-min pre-incubation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Savory J,Titheradge AC,Cross RE,Wills MR

    更新日期:1981-01-01 00:00:00

  • Assay of an antitumor protein, neocarzinostatin, and its antibody by fluorescence polarization.

    abstract::I evaluated use of the fluorescence polarization technique to measure neocarzinostatin, a proteinaceous antitumor antibiotic, and its antibody, in serum. The antigen (neocarzinostatin), labeled with fluorescein isothiocyanate, was allowed to interact with its antibody in a cuvet, in the instrument, yielding an increas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maeda H

    更新日期:1978-12-01 00:00:00