Abstract:
BACKGROUND:Monitoring of the concentration of gentamicin in serum and plasma during therapy is widely recommended and practiced in hospitals. Our aim was to develop a homogeneous immunoassay based on particle-enhanced turbidimetric inhibition immunoassay technology to quantify gentamicin on the Dimension clinical chemistry system. METHODS:Assay performance was assessed on each of the Dimension models in a 15-instrument interlaboratory comparison study. A split-sample comparison (n = 1171) was also performed between the gentamicin methods on the Dimension system and the Abbott TDx analyzer, using multiple reagent and calibrator lots on multiple instruments. RESULTS:The Dimension method was linear to 25.1 micromol/L (12.0 microg/mL) with a detection limit of 0.63 micromol/L (0.3 microg/mL). Calibration was stable for 30 days. The within-run imprecision (CV) was <1.3%, and total imprecision ranged from 1.8% to 3.2% between 4.2 micromol/L (2.0 microg/mL) and 16.7 micromol/L (8.0 microg/mL) gentamicin. Linear regression analysis of the results on the Dimension method (DM) vs the Abbott TDx yielded the following equation: DM = 0.98TDx - 0.42; r = 0.987. Minimal interference was observed from structurally related compounds such as sagamicin, netilmicin, and sisomicin. CONCLUSION:The monoclonal antibody used in this method has similar reactivities toward the individual gentamicin subspecies C1, C1a, and C2, thus providing analytical recovery not significantly dependent on relative subspecies concentrations.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Wei TQ,Chu VP,Craig AR,Duffy JE,Obzansky DM,Kilgore D,Masulli IS,Sanders CM,Thompson JCsubject
Has Abstractpub_date
1999-03-01 00:00:00pages
388-93issue
3eissn
0009-9147issn
1530-8561journal_volume
45pub_type
杂志文章abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1991-10-01 00:00:00
abstract::We measured thyroid hormones and thyroxin-binding proteins in serum from 62 normal lactating and 52 nonlactating women at three months postpartum, and compared these values with those for 42 nonpregnant control women of similar age. Mean thyroxin concentrations in the lactating and nonlactating women were significantl...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-07-01 00:00:00
abstract::We describe the process of certification for a gamma-glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the exclusion of some dat...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-11-01 00:00:00
abstract:BACKGROUND:We investigated agreement between self-reported prenatal alcohol exposure (PAE) and objective meconium alcohol markers to determine the optimal meconium marker and threshold for identifying PAE. METHODS:Meconium fatty acid ethyl esters (FAEE), ethyl glucuronide (EtG), and ethyl sulfate (EtS) were quantified...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2014.233718
更新日期:2015-03-01 00:00:00
abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-07-01 00:00:00
abstract::We report a procedure for determining fecal long-chain fatty acids (LCFA), triglycerides, and cholesterol after detergent extraction with 10 mL/L Triton X-100, 6 mL/L Brij 30, and 0.1 mol/L HCl in isotonic saline by enzymatic analysis of the extraction supernates. Mean recoveries of calibrators ranged from 105% to 117...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-12-01 00:00:00
abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-08-01 00:00:00
abstract::In this report on trace-element concentrations (As, Ca, Cd, Cl, Co, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Sb, Se, Zn) in human heart, liver, kidney, aorta, and rib obtained from 200 autopsied patients, we give special attention to sampling procedure, analysis technique, and various sources of error (autolysis...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-11-01 00:00:00
abstract:BACKGROUND:Reduced renal function is an established risk factor for cardiovascular events. We compared 3 measures of renal function--serum cystatin C, serum creatinine, and calculated creatinine clearance--as predictors of subsequent cardiovascular events in a community-based population of elderly individuals. METHODS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.135962
更新日期:2010-05-01 00:00:00
abstract::Clinicians experience difficulty in correctly interpreting the results of in vitro thyroid function tests in the presence of abnormalities of thyrobinding proteins or when results are borderline. This difficulty has been largely resolved in our laboratory by three innovations. First, the borderline areas for each of t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract:BACKGROUND:Extracellular vesicles (EVs) contain a rich cargo of different RNA species with specialized functions and clinical applications. However, the landscape and characteristics of extracellular vesicle long RNA (exLR) in human blood remain largely unknown. METHODS:We presented an optimized strategy for exLR sequ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.301291
更新日期:2019-06-01 00:00:00
abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.050062
更新日期:2005-09-01 00:00:00
abstract:BACKGROUND:Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within- (CV(i)) an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-04-01 00:00:00
abstract:BACKGROUND:Whether low plasma 25-hydroxyvitamin D concentrations cause osteoporotic fractures is unclear. We tested the hypothesis that low plasma 25-hydroxyvitamin D concentrations are associated with increased risk of osteoporotic fractures using a Mendelian randomization analysis. METHODS:We genotyped 116 335 rando...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1093/clinchem/hvaa049
更新日期:2020-05-01 00:00:00
abstract::This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other metho...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-02-01 00:00:00
abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-01-01 00:00:00
abstract::The basic theory of thyroxin-analog-based radioimmunoassays for free thyroxin has been extended to evaluate definitively the effects arising from residual binding of the tracer analog to serum proteins. Using experimentally determined binding constants and computer simulation techniques, we studied the effects of thyr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-10-01 00:00:00
abstract::We investigated the effects on plasma osteocalcin concentrations of different anticoagulants used to collect the blood samples. Plasma osteocalcin concentrations measured by enzyme immunoassay and radioimmunoassay are influenced by the nature of the anticoagulants used. The most significant difference between concentr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-02-01 00:00:00
abstract::Three different techniques of lipase (EC 3.1.1.3) determination (titrimetry, nephelometry, and enzyme immunoassay) were used to investigate an interesting effect of ionic strength on enzyme activity. Both activation in the presence of NaCl (140 mmol/L) and strong immunoinhibition were observed for lipase from plasma o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-03-01 00:00:00
abstract::This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-06-01 00:00:00
abstract::The aim of this investigation was to study the distribution of arsenic species in human organs following fatal acute intoxication by arsenic trioxide. The collected autopsy samples of most organs were ground and dried, and the total arsenic was measured by electrothermal atomic absorption spectrometry (ETAAS). The ars...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-02-01 00:00:00
abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract::We adapted an inhibition assay for methotrexate, involving dihydrofolate reductase from bovine liver, for use with a discrete analyzer (the ABA-100). The analyzer was used both for dilution and a 5-min pre-incubation of the sample with NADPH--enzyme reagent, and for the assay itself. The standard curve was linear betw...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-02-01 00:00:00
abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract::A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fl...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:BACKGROUND:C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS:We sent 40 different serum samp...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2007.101287
更新日期:2008-06-01 00:00:00
abstract:BACKGROUND:Tamoxifen is a standard endocrine therapy for the prevention and treatment of steroid hormone receptor-positive breast cancer. CONTENT:Tamoxifen requires enzymatic activation by cytochrome P450 (CYP) enzymes for the formation of active metabolites 4-hydroxytamoxifen and endoxifen. As compared with the paren...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2008.121756
更新日期:2009-10-01 00:00:00
abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.026591
更新日期:2004-04-01 00:00:00
abstract::We evaluated the HemoCue beta-Glucose Photometer system for use in our neonatal intensive care unit by assaying 178 heparinized whole-blood samples obtained by heel stick. The required sample size is 5 microL. Plasma glucose was analysed by a glucose oxidase/oxygen electrode methodology. Across the glucose range of 1....
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-11-01 00:00:00