Automated homogeneous immunoassay for gentamicin on the dimension clinical chemistry system.

Abstract:

BACKGROUND:Monitoring of the concentration of gentamicin in serum and plasma during therapy is widely recommended and practiced in hospitals. Our aim was to develop a homogeneous immunoassay based on particle-enhanced turbidimetric inhibition immunoassay technology to quantify gentamicin on the Dimension clinical chemistry system. METHODS:Assay performance was assessed on each of the Dimension models in a 15-instrument interlaboratory comparison study. A split-sample comparison (n = 1171) was also performed between the gentamicin methods on the Dimension system and the Abbott TDx analyzer, using multiple reagent and calibrator lots on multiple instruments. RESULTS:The Dimension method was linear to 25.1 micromol/L (12.0 microg/mL) with a detection limit of 0.63 micromol/L (0.3 microg/mL). Calibration was stable for 30 days. The within-run imprecision (CV) was <1.3%, and total imprecision ranged from 1.8% to 3.2% between 4.2 micromol/L (2.0 microg/mL) and 16.7 micromol/L (8.0 microg/mL) gentamicin. Linear regression analysis of the results on the Dimension method (DM) vs the Abbott TDx yielded the following equation: DM = 0.98TDx - 0.42; r = 0.987. Minimal interference was observed from structurally related compounds such as sagamicin, netilmicin, and sisomicin. CONCLUSION:The monoclonal antibody used in this method has similar reactivities toward the individual gentamicin subspecies C1, C1a, and C2, thus providing analytical recovery not significantly dependent on relative subspecies concentrations.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Wei TQ,Chu VP,Craig AR,Duffy JE,Obzansky DM,Kilgore D,Masulli IS,Sanders CM,Thompson JC

subject

Has Abstract

pub_date

1999-03-01 00:00:00

pages

388-93

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

45

pub_type

杂志文章
  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Decrease of free thyroxin in serum of lactating women.

    abstract::We measured thyroid hormones and thyroxin-binding proteins in serum from 62 normal lactating and 52 nonlactating women at three months postpartum, and compared these values with those for 42 nonpregnant control women of similar age. Mean thyroxin concentrations in the lactating and nonlactating women were significantl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iwatani Y,Amino N,Tanizawa O,Mori H,Kawashima M,Yabu Y,Miyai K

    更新日期:1987-07-01 00:00:00

  • Production and certification of an enzyme reference material for gamma-glutamyltransferase (CRM 319). Part 2: Certification campaign.

    abstract::We describe the process of certification for a gamma-glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the exclusion of some dat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schiele F,Muller J,Colinet E,Siest G

    更新日期:1987-11-01 00:00:00

  • Clinical sensitivity and specificity of meconium fatty acid ethyl ester, ethyl glucuronide, and ethyl sulfate for detecting maternal drinking during pregnancy.

    abstract:BACKGROUND:We investigated agreement between self-reported prenatal alcohol exposure (PAE) and objective meconium alcohol markers to determine the optimal meconium marker and threshold for identifying PAE. METHODS:Meconium fatty acid ethyl esters (FAEE), ethyl glucuronide (EtG), and ethyl sulfate (EtS) were quantified...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.233718

    authors: Himes SK,Dukes KA,Tripp T,Petersen JM,Raffo C,Burd L,Odendaal H,Elliott AJ,Hereld D,Signore C,Willinger M,Huestis MA,Prenatal Alcohol in SIDS and Stillbirth (PASS) Network.

    更新日期:2015-03-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • Detergent extraction and enzymatic analysis for fecal long-chain fatty acids, triglycerides, and cholesterol.

    abstract::We report a procedure for determining fecal long-chain fatty acids (LCFA), triglycerides, and cholesterol after detergent extraction with 10 mL/L Triton X-100, 6 mL/L Brij 30, and 0.1 mol/L HCl in isotonic saline by enzymatic analysis of the extraction supernates. Mean recoveries of calibrators ranged from 105% to 117...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lee MJ,Crook T,Noel C,Levinson UM

    更新日期:1994-12-01 00:00:00

  • The fiscal consequences of central vs distributed testing of glucose.

    abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkelman JW,Wybenga DR,Tanasijevic MJ

    更新日期:1994-08-01 00:00:00

  • Trace-element concentrations in human autopsy tissue.

    abstract::In this report on trace-element concentrations (As, Ca, Cd, Cl, Co, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, Ni, Pb, Rb, Sb, Se, Zn) in human heart, liver, kidney, aorta, and rib obtained from 200 autopsied patients, we give special attention to sampling procedure, analysis technique, and various sources of error (autolysis...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aalbers TG,Houtman JP,Makkink B

    更新日期:1987-11-01 00:00:00

  • Comparison of cystatin C and creatinine as predictors of cardiovascular events in a community-based elderly population.

    abstract:BACKGROUND:Reduced renal function is an established risk factor for cardiovascular events. We compared 3 measures of renal function--serum cystatin C, serum creatinine, and calculated creatinine clearance--as predictors of subsequent cardiovascular events in a community-based population of elderly individuals. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.135962

    authors: Beilby J,Divitini ML,Knuiman MW,Rossi E,Hung J

    更新日期:2010-05-01 00:00:00

  • Pictorial reporting of multiple thyroid function results.

    abstract::Clinicians experience difficulty in correctly interpreting the results of in vitro thyroid function tests in the presence of abnormalities of thyrobinding proteins or when results are borderline. This difficulty has been largely resolved in our laboratory by three innovations. First, the borderline areas for each of t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pain RW,Duncan BM

    更新日期:1976-10-01 00:00:00

  • Extracellular Vesicles Long RNA Sequencing Reveals Abundant mRNA, circRNA, and lncRNA in Human Blood as Potential Biomarkers for Cancer Diagnosis.

    abstract:BACKGROUND:Extracellular vesicles (EVs) contain a rich cargo of different RNA species with specialized functions and clinical applications. However, the landscape and characteristics of extracellular vesicle long RNA (exLR) in human blood remain largely unknown. METHODS:We presented an optimized strategy for exLR sequ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.301291

    authors: Li Y,Zhao J,Yu S,Wang Z,He X,Su Y,Guo T,Sheng H,Chen J,Zheng Q,Li Y,Guo W,Cai X,Shi G,Wu J,Wang L,Wang P,He X,Huang S

    更新日期:2019-06-01 00:00:00

  • Automated on-line solid-phase extraction coupled with HPLC for measurement of 5-hydroxyindole-3-acetic acid in urine.

    abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050062

    authors: Mulder EJ,Oosterloo-Duinkerken A,Anderson GM,De Vries EG,Minderaa RB,Kema IP

    更新日期:2005-09-01 00:00:00

  • Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A(1c), IgA, prolactin, and free testosterone in healthy women.

    abstract:BACKGROUND:Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within- (CV(i)) an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garde AH,Hansen AM,Skovgaard LT,Christensen JM

    更新日期:2000-04-01 00:00:00

  • 25-Hydroxyvitamin D and Risk of Osteoporotic Fractures: Mendelian Randomization Analysis in 2 Large Population-Based Cohorts.

    abstract:BACKGROUND:Whether low plasma 25-hydroxyvitamin D concentrations cause osteoporotic fractures is unclear. We tested the hypothesis that low plasma 25-hydroxyvitamin D concentrations are associated with increased risk of osteoporotic fractures using a Mendelian randomization analysis. METHODS:We genotyped 116 335 rando...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa049

    authors: Çolak Y,Afzal S,Nordestgaard BG

    更新日期:2020-05-01 00:00:00

  • Automated enhanced latex agglutination assay for rheumatoid factors in serum.

    abstract::This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other metho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkles JW,Lunec J,Gray L

    更新日期:1989-02-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00

  • Comprehensive study of a thyroxin-analog-based assay for free thyroxin ("Amerlex FT4").

    abstract::The basic theory of thyroxin-analog-based radioimmunoassays for free thyroxin has been extended to evaluate definitively the effects arising from residual binding of the tracer analog to serum proteins. Using experimentally determined binding constants and computer simulation techniques, we studied the effects of thyr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilkins TA,Midgley JE,Barron N

    更新日期:1985-10-01 00:00:00

  • Osteocalcin concentrations in plasma prepared with different anticoagulants.

    abstract::We investigated the effects on plasma osteocalcin concentrations of different anticoagulants used to collect the blood samples. Plasma osteocalcin concentrations measured by enzyme immunoassay and radioimmunoassay are influenced by the nature of the anticoagulants used. The most significant difference between concentr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Power MJ,O'Dwyer B,Breen E,Fottrell PF

    更新日期:1991-02-01 00:00:00

  • Differentiating two forms of plasma lipase by use of media with different ionic strengths.

    abstract::Three different techniques of lipase (EC 3.1.1.3) determination (titrimetry, nephelometry, and enzyme immunoassay) were used to investigate an interesting effect of ionic strength on enzyme activity. Both activation in the presence of NaCl (140 mmol/L) and strong immunoinhibition were observed for lipase from plasma o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Arzoglou PL,Férard G,Métais P

    更新日期:1984-03-01 00:00:00

  • Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.

    abstract::This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bertholf RL,Brown S,Renoe BW,Wills MR,Savory J

    更新日期:1983-06-01 00:00:00

  • Arsenic speciation in human organs following fatal arsenic trioxide poisoning--a case report.

    abstract::The aim of this investigation was to study the distribution of arsenic species in human organs following fatal acute intoxication by arsenic trioxide. The collected autopsy samples of most organs were ground and dried, and the total arsenic was measured by electrothermal atomic absorption spectrometry (ETAAS). The ars...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Benramdane L,Accominotti M,Fanton L,Malicier D,Vallon JJ

    更新日期:1999-02-01 00:00:00

  • Analytical performance of EMIT cyclosporine assay evaluated.

    abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Desai M

    更新日期:1991-12-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Enzymic inhibition assay for methotrexate with a discrete analyzer, the ABA-100.

    abstract::We adapted an inhibition assay for methotrexate, involving dihydrofolate reductase from bovine liver, for use with a discrete analyzer (the ABA-100). The analyzer was used both for dilution and a 5-min pre-incubation of the sample with NADPH--enzyme reagent, and for the assay itself. The standard curve was linear betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown LF,Johnson GF,Witte DL,Feld RD

    更新日期:1980-02-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • Total urinary hydroxyproline determined with rapid and simple high-performance liquid chromatography.

    abstract::A precolumn derivatization method was optimized for rapid and specific analysis of total urinary hydroxyproline by HPLC. After an overnight hydrolysis, urine samples dried and reconstituted with the internal standard cysteic acid (in sodium hydrogen carbonate, pH 9.3) were derivatized with N,N-diethyl-2,4-dinitro-5-fl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Paroni R,De Vecchi E,Fermo I,Arcelloni C,Diomede L,Magni F,Bonini PA

    更新日期:1992-03-01 00:00:00

  • Standardization of C-peptide measurements.

    abstract:BACKGROUND:C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS:We sent 40 different serum samp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2007.101287

    authors: Little RR,Rohlfing CL,Tennill AL,Madsen RW,Polonsky KS,Myers GL,Greenbaum CJ,Palmer JP,Rogatsky E,Stein DT

    更新日期:2008-06-01 00:00:00

  • Pharmacogenomics of tamoxifen therapy.

    abstract:BACKGROUND:Tamoxifen is a standard endocrine therapy for the prevention and treatment of steroid hormone receptor-positive breast cancer. CONTENT:Tamoxifen requires enzymatic activation by cytochrome P450 (CYP) enzymes for the formation of active metabolites 4-hydroxytamoxifen and endoxifen. As compared with the paren...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.121756

    authors: Brauch H,Mürdter TE,Eichelbaum M,Schwab M

    更新日期:2009-10-01 00:00:00

  • Detection of hemoglobin-based oxygen carriers in human serum for doping analysis: confirmation by size-exclusion HPLC.

    abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026591

    authors: Varlet-Marie E,Ashenden M,Lasne F,Sicart MT,Marion B,de Ceaurriz J,Audran M

    更新日期:2004-04-01 00:00:00

  • HemoCue beta-glucose photometer evaluated for use in a neonatal intensive care unit.

    abstract::We evaluated the HemoCue beta-Glucose Photometer system for use in our neonatal intensive care unit by assaying 178 heparinized whole-blood samples obtained by heel stick. The required sample size is 5 microL. Plasma glucose was analysed by a glucose oxidase/oxygen electrode methodology. Across the glucose range of 1....

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vadasdi E,Jacobs E

    更新日期:1993-11-01 00:00:00