Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

Abstract:

:We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported, both for 17-year-olds and adults examined twice, with a median period of two months between measurements. Stability was similar in a subsample of adults who had an additional measurement a median of 28 months later. Within-assay analytical variation (CV) was 1.9-2.0% for cholesterol, 1.5-2.3% for triglyceride, and 4.5% for high-density-lipoprotein cholesterol. Between-assay variation was 3-5% for cholesterol and triglyceride and 10% for high-density-lipoprotein cholesterol. The lower stability of the lipoprotein fractions of cholesterol than of total cholesterol emphasizes the need for repeated measurements of these fractions for more accurate characterization of subjects, especially those with extreme values, both for clinical use and for predicting outcome in follow-up studies.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Friedlander Y,Kark JD,Stein Y

subject

Has Abstract

pub_date

1985-07-01 00:00:00

pages

1121-6

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

31

pub_type

杂志文章
  • Analytical goal-setting for monitoring patients when two analytical methods are used.

    abstract::Serial results from an individual are often obtained using more than one method. Results should be transferable over time and locale. Every method has inherent analytical error, and goals are required to delineate the maximum allowable random (imprecision) and systematic (inaccuracy, bias) errors to facilitate optimal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Petersen PH,Fraser CG,Westgard JO,Larsen ML

    更新日期:1992-11-01 00:00:00

  • Gas-chromatographic measurement of carboxyhemoglobin in blood from mothers and newborns.

    abstract::HbCO in blood sampled from 20 mothers and newborns immediately after birth was measured with a new, simple gas-chromatographic method for CO. The mean ratio of HbCO to total hemoglobin for 13 non-smoking mothers did not differ significantly from that for their infants (mean 0.38%, SD 0.26% vs 0.38%, SD 0.13%), but the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogh-Andersen N,Eriksen PS,Grinsted J,Siggaard-Andersen O

    更新日期:1988-01-01 00:00:00

  • Simultaneous assay of corticosterone and cortisol in plasma by reversed-phase liquid chromatography.

    abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hariharan M,Naga S,VanNoord T,Kindt EK

    更新日期:1992-03-01 00:00:00

  • Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function ChemFET integrated-circuit sensor.

    abstract::On-line, simultaneous measurement of blood K+, Ca2+, Na+, and pH has been achieved by using a quadruple-function ChemFET (chemical-sensitive field-effect transistor) integrated-circuit sensor. Blood is withdrawn from the subject through an actively heparinized, dual-lumen cannula and passed into a flow-cell containing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sibbald A,Covington AK,Carter RF

    更新日期:1984-01-01 00:00:00

  • Serum protein profiles by "high-performance" liquid chromatography with detection at multiple wavelengths.

    abstract::We have separated serum proteins in only 15 min by high-performance liquid chromatography. The identification of several peaks in the chromatographic profile was greatly aided by the use of multiple-wavelength detection. We have found a good correlation between retention times and electrophoretic mobilities. Serum sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schlabach TD,Abbott SR

    更新日期:1980-09-01 00:00:00

  • Report of the National Heart, Lung, and Blood Institute Workshop on Lipoprotein(a) and Cardiovascular Disease: recent advances and future directions.

    abstract::It has been estimated that approximately 37% of the US population judged to be at high risk for developing coronary artery disease (CAD), based on the National Cholesterol Education Program guidelines, have increased plasma lipoprotein(a) [Lp(a)], whereas Lp(a) is increased in only 14% of those judged to be at low ris...

    journal_title:Clinical chemistry

    pub_type:

    doi:10.1373/clinchem.2003.023689

    authors: Marcovina SM,Koschinsky ML,Albers JJ,Skarlatos S

    更新日期:2003-11-01 00:00:00

  • Monomeric calgranulins measured by SELDI-TOF mass spectrometry and calprotectin measured by ELISA as biomarkers in arthritis.

    abstract:BACKGROUND:SELDI-TOF mass spectrometry (MS) is a high-throughput proteomic approach with potential for identifying novel forms of serum biomarkers of arthritis. METHODS:We used SELDI-TOF MS to analyze serum samples from patients with various forms of inflammatory arthritis. Several protein profiles were collected on d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.099549

    authors: de Seny D,Fillet M,Ribbens C,Marée R,Meuwis MA,Lutteri L,Chapelle JP,Wehenkel L,Louis E,Merville MP,Malaise M

    更新日期:2008-06-01 00:00:00

  • Assay for erythrocyte uroporphyrinogen I synthase activity, with porphobilinogen as substrate.

    abstract::We describe a convenient, economical procedure for measuring uroporphyrinogen I synthase (EC 4.3 1.8) activity in erythrocytes, the results of which can be used to diagnose acute intermittent porphyria, in either its latent or acute stage. By limiting the test reaction sequence to the conversion of porphobilinogen to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ford RE,Ou CN,Ellefson RD

    更新日期:1980-07-01 00:00:00

  • Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability.

    abstract::Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lott JA,Smith DA,Mitchell LC,Moeschberger ML

    更新日期:1996-06-01 00:00:00

  • Comparison of LDL cholesterol concentrations by Friedewald calculation and direct measurement in relation to cardiovascular events in 27,331 women.

    abstract:BACKGROUND:National Cholesterol Education Program (NCEP) guidelines recommend development of direct assays for LDL cholesterol (LDL-C) measurement, but it is unclear how these assays compare with Friedewald calculation in predicting cardiovascular disease (CVD). METHODS:In a study of 27 331 healthy women with triglyce...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.117929

    authors: Mora S,Rifai N,Buring JE,Ridker PM

    更新日期:2009-05-01 00:00:00

  • Established and emerging markers of kidney function.

    abstract:BACKGROUND:The kidney performs a multitude of essential functions to maintain homeostasis. In clinical medicine, glomerular filtration rate (GFR) provides the best index of overall kidney function, and proteinuria adds additional information on renal and nonrenal prognosis. Several novel biomarkers of kidney injury and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2011.167494

    authors: Ferguson MA,Waikar SS

    更新日期:2012-04-01 00:00:00

  • Turnover rate of skeletal alkaline phosphatase in humans.

    abstract::Two patients with Paget's disease of bone were subjected to plasmapheresis. Alkaline phosphatase activities of serum declined sharply, but returned to preplasmapheresis values within eight to 10 days. The biological half-life of circulating skeletal alkaline phosphatase, as calculated from these experiments, is betwee...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Posen S,Grunstein HS

    更新日期:1982-01-01 00:00:00

  • Time series modeling for quality control in clinical chemistry.

    abstract::Autocorrelation of clinical chemistry quality-control (Q/C) measurements causes one of the basic assumptions underlying the use of Levey-Jennings control charts to be violated and performance to be degraded. This is the requirement that the observations be statistically independent. We present a proposal for a new app...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alwan LC,Bissell MG

    更新日期:1988-07-01 00:00:00

  • Use of a quality-control plasma sample to decrease interassay variation in radioimmunoassays of apolipoprotein A-I.

    abstract::The apolipoprotein A-I (apo A-I) radioimmunoassay established in our laboratory involves use of purified apo A-I as the primary standard for quantifying apo A-I in plasma and a pooled plasma (quality-control sample) as a secondary standard to decrease interassay variation. The measured values for apo A-I increased ove...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Au YP,Hallaway BJ,Kottke BA

    更新日期:1986-07-01 00:00:00

  • Quality-control (QC) performance measures and the QC planning process.

    abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Parvin CA

    更新日期:1997-04-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • Factors behind the increase in cardiovascular mortality in Russia: apolipoprotein AI and B distribution in the Arkhangelsk study 2000.

    abstract:BACKGROUND:Cardiovascular mortality is markedly higher in Russia than in Western Europe and the US. Little is known about indicators of atherosclerotic risk in the Russian population. To our knowledge, this is the first study of apolipoprotein (apo) AI and B in Russia based on the WHO-IFCC standard. METHODS:We measure...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.023853

    authors: Averina M,Nilssen O,Brenn T,Brox J,Arkhipovsky VL,Kalinin AG

    更新日期:2004-02-01 00:00:00

  • The metabolic syndrome: requiescat in pace.

    abstract::Values for insulin-mediated glucose disposal vary continuously throughout a population of apparently healthy individuals, with at least a sixfold variation between the most insulin sensitive and most insulin resistant of these individuals. The more insulin resistant a person, the more insulin must be secreted to preve...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2005.048611

    authors: Reaven GM

    更新日期:2005-06-01 00:00:00

  • Proenzyme forms of prostate-specific antigen in serum improve the detection of prostate cancer.

    abstract:INTRODUCTION:Pro or precursor forms of prostate-specific antigen (PSA) have emerged as potentially important diagnostic serum markers for prostate cancer detection. Immunoassays were developed to measure specific proPSA forms containing propeptides of 2, 4, and 7 amino acids [(-2)proPSA, (-4)proPSA, and (-7)proPSA, res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026823

    authors: Mikolajczyk SD,Catalona WJ,Evans CL,Linton HJ,Millar LS,Marker KM,Katir D,Amirkhan A,Rittenhouse HG

    更新日期:2004-06-01 00:00:00

  • Gas-chromatographic determination of cholesterol sulfate in plasma and erythrocytes, for the diagnosis of recessive X-linked ichthyosis.

    abstract::We describe a rapid method for determining cholesterol sulfate in plasma and erythrocytes. After its single-step isolation by means of anion-exchange chromatography cholesterol sulfate is hydrolyzed, trimethylsilylated, and determined by gas chromatography with flame ionization detection. 5 beta-Cholestan-3 alpha-ol s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Jansen G,Wolthers BG,Marinkovic-Ilsen A,van Voorst Vader PC

    更新日期:1983-07-01 00:00:00

  • Nitromethane interferes in assay of creatinine by the Jaffé reaction.

    abstract::A patient who ingested a methanol/nitromethane mixture (model airplane fuel) showed an apparent plasma creatinine concentration of 8.0 mmol/L by the Jaffé reaction when the actual creatinine concentration, as measured by a specific enzymatic method, was 0.09 mmol/L. This effect was due to nitromethane in the plasma. I...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: De Leacy EA,Brown NN,Clague AE

    更新日期:1989-08-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A

    更新日期:1997-09-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Prognostic value of combined data on enzymes and inflammation markers in plasma in cases of severe head injury.

    abstract::We measured certain enzyme activities (aldolase, aspartate aminotransferase, creatine kinase, and lactate dehydrogenase) and inflammation markers (alpha 1-antitrypsin, C-reactive protein, fibrinogen, and leukocytes) each day for four days in plasma of patients with severe head injury. The univariate prognostic efficie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bourguignat A,Albert A,Férard G,Tulasne PA,Kempf I,Métais P

    更新日期:1983-11-01 00:00:00

  • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures.

    abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.173856

    authors: Hoofnagle AN,Becker JO,Oda MN,Cavigiolio G,Mayer P,Vaisar T

    更新日期:2012-04-01 00:00:00

  • Separation of bound and free ligand by ethacridine (Rivanol) in thyroxin radioimmunoassay.

    abstract::In this simple and low-cost radioimmunoassay (RIA) procedure for thyroxin (T4), ethacridine (6,9-diamino-2-ethoxyacridine lactate; Rivanol) is used to separate antibody-bound ligand and free ligand. This acridine dye precipitates free T4 not bound to antibody. At pH 8.6, it precipitates more than 90% of 125I-labeled T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bhupal V,Mani RS

    更新日期:1983-11-01 00:00:00

  • Kinetic serum creatinine assays I. The role of various factors in determining specificity.

    abstract::We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interfere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers LD

    更新日期:1980-04-01 00:00:00

  • Discrete modular system for automation of radioimmunoassay of serum choriomammotropin.

    abstract::We describe a discrete automated radioimmunoassay system for determining choriomammotropin (placental lactogen) in human serum. With the present system it can be measured in as many as 37 unknown sera (50 muL) and three quality-control sera, in duplicate, within 1.5 h. The time required for sample preparation, incubat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hammond GL,Leinonen P,Vihko R

    更新日期:1979-01-01 00:00:00

  • Effect of stripping thyroxin from thyroxin-binding globulin on the measurement of free thyroxin in serum by equilibrium dialysis and by radioimmunoassay.

    abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakagawa T,Matsumura K,Takeda K,Shinoda N,Matsuda A,Matsushita T,Tagami T

    更新日期:1990-02-01 00:00:00

  • Simultaneous detection of high-sensitivity cardiac troponin I and myoglobin by modified sandwich lateral flow immunoassay: proof of principle.

    abstract:BACKGROUND:Although numerous lateral flow immunoassays (LFIAs) have been developed and widely used, inadequate analytical sensitivity and the lack of multiple protein detection applications have limited their clinical utility. We developed a new LFIA device for the simultaneous detection of high-sensitivity cardiac tro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.171694

    authors: Zhu J,Zou N,Zhu D,Wang J,Jin Q,Zhao J,Mao H

    更新日期:2011-12-01 00:00:00