Nitromethane interferes in assay of creatinine by the Jaffé reaction.

Abstract:

:A patient who ingested a methanol/nitromethane mixture (model airplane fuel) showed an apparent plasma creatinine concentration of 8.0 mmol/L by the Jaffé reaction when the actual creatinine concentration, as measured by a specific enzymatic method, was 0.09 mmol/L. This effect was due to nitromethane in the plasma. Interference by nitromethane with the determination of creatinine by reaction with alkaline picrate (the Jaffé reaction) has not previously been reported. When nitromethane was added to plasma, the apparent creatinine measured was linearly related to the amount of nitromethane added. Comparison of spectral changes occurring during creatinine/picrate and nitromethane/picrate reactions show substantial similarity, suggesting a similar structure for the products. Although the findings are of interest for both their toxicological and analytical implications, the main interest lies with their suggestion of a model system for future investigation of the Jaffé reaction.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

De Leacy EA,Brown NN,Clague AE

subject

Has Abstract

pub_date

1989-08-01 00:00:00

pages

1772-4

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Use of a programmable desk-top calculator for the statistical quality control of radioimmunoassays.

    abstract::We have developed an interactive statistical quality-control system for the small- to medium-sized radioimmunoassay laboratory, which can be used in a programmable desk-top calculator instead of the medium- or large-scale computer systems usually required. The design of this quality-control system is modeled after the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cernosek SF Jr,Gutierrez-Cernosek RM

    更新日期:1978-07-01 00:00:00

  • Direct ultraviolet method for enzymatic determination of uric acid, with equilibrium and kinetic data-processing options.

    abstract::We developed and evaluated a direct ultraviolet method for the enzymatic determination of uric acid in serum, plasma, or urine, without deproteinization of sera and plasma. Equilibrium and nonlinear curve-fitting kinetic options are evaluated and compared, and results of the proposed method are compared with those of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dilena BA,Peake MJ,Pardue HL,Skoug JW

    更新日期:1986-03-01 00:00:00

  • Application of a sequence-specific radioimmunoassay for the carboxyl-terminal region of corticotropin.

    abstract::The carboxyl terminal region of corticotropin (ACTH), (Ala34-Phe-Pro-Glu-Leu-Phe39), a region of the hormone conserved during evolution, served as an antigen for the production of a sequence-specific antiserum. In a radioimmunoassay, peptides that extend toward the amino terminal from Ala34, such as [Tyr,Gly]-ACTH34-3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lazarus LH,DiAugustine RP,Khan MN,Jahnke GD,Erisman MD

    更新日期:1981-04-01 00:00:00

  • Evaluation of preanalytical variables associated with measurement of prothrombin fragment 1.2.

    abstract::We have used a monoclonal antibody-based ELISA for plasma prothrombin fragment 1.2 (F1.2) to establish appropriate sample collection and storage conditions for this biomarker of thrombin generation. F1.2 concentrations were not altered by exogenous factor Xa, thrombin, or thromboplastin if blood was collected by routi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Greenberg CS,Hursting MJ,Macik BG,Ortel TL,Kane WH,Moore BM

    更新日期:1994-10-01 00:00:00

  • Detection and characterization of blocking-type anti-acetylcholine receptor antibodies in sera from patients with myasthenia gravis.

    abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hara H,Hayashi K,Ohta K,Itoh N,Nishitani H,Ohta M

    更新日期:1993-10-01 00:00:00

  • DNA enzyme immunoassay: general method for detecting products of polymerase chain reaction.

    abstract::We developed a new colorimetric method, DNA enzyme immunoassay (DEIA), for detecting specific hybrids of complementary nucleic acids and applied it to the detection of hepatitis B virus (HBV) DNA amplified from serum samples by means of the polymerase chain reaction (PCR) technique. The method is based on the ability ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mantero G,Zonaro A,Albertini A,Bertolo P,Primi D

    更新日期:1991-03-01 00:00:00

  • Direct solid-phase time-resolved immunofluorometric assay of cortisol in serum.

    abstract::A dissociation-enhanced lanthanide fluoroimmunoassay of serum cortisol based on time-resolved fluorescence is described. The assay is a direct assay, where cortisol immobilized on the wall of a microtiter-strip well competes with cortisol in the sample for the europium-labeled polyclonal antibody. The amount of bound ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eskola JU,Näntö V,Meurling L,Lövgren TN

    更新日期:1985-10-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Statistical interpretation of concentrations of magnesium, zinc, calcium, potassium, cholesterols, and creatine kinase isoenzymes in men at different stages of ischemic heart disease.

    abstract::We present a statistical interpretation of plasma (Pl) and (or) erythrocyte (Erc) concentrations of magnesium, zinc, calcium, potassium, and total high-density lipoprotein (HDL) cholesterol, as well as of the activity of total creatine kinase (CK) and its CK-MB isoenzyme, in 26 men with pre-infarction syndrome (PIS) a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Speich M,Auget JL,Arnaud P

    更新日期:1989-05-01 00:00:00

  • Cholesterol screening: comparative evaluation of on-site and laboratory-based measurements.

    abstract::We measured cholesterol in capillary blood samples from 9683 volunteers over a four-day on-site community screening program, using the "Reflotron" desk-top analyzer (Boehringer-Mannheim Diagnostics, Indianapolis, IN). We also measured cholesterol in venous blood samples from 3% of those screened (a) with the Reflotron...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bachorik PS,Rock R,Cloey T,Treciak E,Becker D,Sigmund W

    更新日期:1990-02-01 00:00:00

  • The clinical utility of high-sensitivity C-reactive protein in cardiovascular disease and the potential implication of JUPITER on current practice guidelines.

    abstract:BACKGROUND:High-sensitivity C-reactive protein (hsCRP) testing is relatively inexpensive and has been shown to predict the risk of cardiovascular disease (CVD) and diabetes in multiple patient groups, including those treated with statin therapy. JUPITER (Justification for the Use of Statins in Primary Prevention: An In...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.109728

    authors: Mora S,Musunuru K,Blumenthal RS

    更新日期:2009-02-01 00:00:00

  • Erroneous results with routine laboratory testing for immunoglobulins due to interference from circulating immune complexes in a case of hyperviscosity syndrome associated with autoimmune disease.

    abstract::A patient with the hyperviscosity syndrome exhibited very high concentrations of intermediate to small circulating immune complexes (CIC), involving 40-50% of the IgG present, with IgG rheumatoid factor activity. We demonstrate that precipitation of CIC by polyethylene glycol in the reaction mixture caused interferenc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levinson SS,Perry M,Goldman J,Nathan LE

    更新日期:1988-04-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00

  • An optimized continuous-monitoring procedure for semiautomated determination of serum acid phosphatase activity.

    abstract::A continuous-monitoring method for measuring acid phosphatase activity with alpha-naphthyl phosphate as the substrate was critically evaluated and modified. Using partially purified prostatic acid phosphatase, we show that certain conditions for the assay must be satisfied to ensure linearity. These conditions include...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bais R,Edwards JB

    更新日期:1976-12-01 00:00:00

  • Novel protein markers of acute coronary syndrome complications in low-risk outpatients: a systematic review of potential use in the emergency department.

    abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2005.052456

    authors: Mitchell AM,Brown MD,Menown IB,Kline JA

    更新日期:2005-11-01 00:00:00

  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • Rapid single-tube screening of the C282Y hemochromatosis mutation by real-time multiplex allele-specific PCR without fluorescent probes.

    abstract:BACKGROUND:An accurate determination of the major HFE mutation (C282Y), which is associated with hereditary hemochromatosis, is important in diagnosis and risk assessment for this disease. We report a single-tube high-throughput PCR method for the detection of C282Y. METHODS:We combined three previously described prin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Donohoe GG,Laaksonen M,Pulkki K,Rönnemaa T,Kairisto V

    更新日期:2000-10-01 00:00:00

  • Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.

    abstract::This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and rep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gault MH,Longerich L,Dawe M,Vasdev SC

    更新日期:1985-08-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Analysis for bismuth in tissue by electrothermal atomic absorption spectrometry.

    abstract::We developed a simple method for the analysis of bismuth (Bi) in biological tissue, using wet digestion for sample pretreatment. Bi was determined by electrothermal atomic absorption spectrometry with platinum as a matrix modifier to decrease the volatility of Bi. The furnace program included a gas stop for sensitivit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Slikkerveer A,Helmich RB,de Wolff FA

    更新日期:1993-05-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • External quality assurance program for PCR amplification of genomic DNA: an Italian experience.

    abstract:BACKGROUND:External quality assurance (EQA) programs for diagnostic tests based on nucleic acid amplification have not been widely implemented in clinical laboratories and remain limited to few tests. Development of specific EQA programs based on application-based proficiency testing for any diagnostic molecular target...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.5.782

    authors: Raggi CC,Pinzani P,Paradiso A,Pazzagli M,Orlando C

    更新日期:2003-05-01 00:00:00

  • Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

    abstract::We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Hammes ME,Gray R,Lineberry B,Abrams B

    更新日期:1992-12-01 00:00:00

  • Apolipoprotein B and A-I values in 147576 Swedish males and females, standardized according to the World Health Organization-International Federation of Clinical Chemistry First International Reference Materials.

    abstract::Serum concentrations of apolipoprotein (apo) B and apo A-I were measured from 1985-1996 in a Swedish population sample of 83 112 males and 64 464 females, ages <20 to >80 years, using an automated immunoturbidimetric method calibrated against fresh pools of human serum and commercial calibrators. All values were recal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jungner I,Marcovina SM,Walldius G,Holme I,Kolar W,Steiner E

    更新日期:1998-08-01 00:00:00

  • Effects of storage time and temperature on urinary enzymes.

    abstract::We measured three renal tubular brush-border enzymes (lactate dehydrogenase, LDH, EC 1.1.1.27; gamma-glutamyltransferase, GGT, EC 2.3.2.2; and alkaline phosphatase, AP, EC 3.1.3.1) in morning urine samples from 48 healthy subjects to check whether different storage times and temperatures could modify enzyme concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matteucci E,Gregori G,Pellegrini L,Navalesi R,Giampietro O

    更新日期:1991-08-01 00:00:00

  • Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation.

    abstract:BACKGROUND:Low concentrations of cardiac troponin (cTn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (hs-cTnI) assay to identify a single test threshold that can safely rule out AMI. METHODS:This analysis used ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.283887

    authors: Greenslade J,Cho E,Van Hise C,Hawkins T,Parsonage W,Ungerer J,Tate J,Pretorius C,Than M,Cullen L

    更新日期:2018-05-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • Inhibitory effects of micronized fenofibrate on carotid atherosclerosis in patients with essential hypertension.

    abstract:BACKGROUND:The coexistence of hypertension and dyslipidemia synergistically increases the risk of cardiovascular events. We investigated the effect of the lipid-lowering agent micronized fenofibrate on inhibition of carotid atherosclerosis in patients with essential hypertension and mild hyperlipidemia. METHODS:We mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.074724

    authors: Zhu S,Su G,Meng QH

    更新日期:2006-11-01 00:00:00

  • Urinary excretion of some proteins and enzymes during normal pregnancy.

    abstract::Total protein (TP), albumin (Alb), transferrin (TRF), retinol-binding protein (RPB), N-acetyl-beta-glucosaminidase (NAG), alanine aminopeptidase (AAP), gamma-glutamyltransferase (GGT), and creatinine (Cr) were measured in random (untimed) urine samples from 29 nonpregnant women and from pregnant subjects (11 in the fi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cheung CK,Lao T,Swaminathan R