Kinetic serum creatinine assays I. The role of various factors in determining specificity.

Abstract:

:We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interferent, the ratio of the rate constants, the extent of the analytical reaction, and the duration of the measurement. To assess the potential diminution of the interference with kinetic methods, we determined the rate constants of several alpha-keto acids in the Jaffé reaction. Evaluation of the advantages of various measuring techniques with respect to specificity showed the main factors to be the extent of the analytical reaction and the relative value of the rate constants. Total specificity for creatine appears to be unattainable with currently used kinetic techniques.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bowers LD

subject

Has Abstract

pub_date

1980-04-01 00:00:00

pages

551-4

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

26

pub_type

杂志文章
  • Novel, aberrantly truncated isoform of serum CD13 in a family with high serum aminopeptidase N (CD13) activity.

    abstract:BACKGROUND:We previously reported a family in which the propositus and both her father and paternal grandmother had high serum aminopeptidase N (CD13; EC 3.4.11.2) activity (autosomal dominant). The molecular mass of the serum CD13 polypeptide of the propositus was larger than that of normal CD13, suggesting either a m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kawai M,Hara Y,Miyazato I,Hosaki S

    更新日期:2001-02-01 00:00:00

  • Modified heparin-Sepharose procedure for determination of plasma lipolytic activities of normolipidemic and hyperlipidemic subjects after injection of heparin.

    abstract::A modified heparin-Sepharose affinity chromatography procedure (Boberg et al., J. Lipid Res. 18:544-547, 1977) was developed to determine two different triglyceride lipase activities in human post-heparin plasma: hepatic triglyceride lipase (I) and lipoprotein lipase (II). With this procedure, lipoproteins were separa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang CS,Bass HB,Downs D,Whitmer RK

    更新日期:1981-05-01 00:00:00

  • Use of a synthetic soluble bilirubin derivative to assess interference in creatinine measurements.

    abstract::In assessing interference from bilirubin, the use of a synthetic soluble derivative (ditaurobilirubin, DTB) is recommended as a surrogate for the natural conjugates (Bc). We compared the interference effect of unconjugated bilirubin (Bu), Bc, and DTB, using six mechanized methods for serum creatinine measurement. No s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Franzini C,Morelli AM,Cattozzo G

    更新日期:1991-02-01 00:00:00

  • Diagnostic and prognostic value of laboratory tests assessed in a follow-up study of 200 patients with liver disease.

    abstract::Two hundred patients with liver disease were re-studied after six to eight years. The initial routine diagnosis (mainly based on morphological criteria) was confirmed in almost 80% of cases of chronic liver disease. In chronic active hepatitis, agreement was found in 86%. An alternative classification based on cluster...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skrede S,Solberg HE,Ritland S,Blomhoff JP,Schrumpf E,Elgjo K,Gjone E

    更新日期:1982-05-01 00:00:00

  • Chemical and immunochemical measurement of total iron-binding capacity compared.

    abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Lewis SA,Iosefsohn M,Hicks JM

    更新日期:1978-10-01 00:00:00

  • Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

    abstract::We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Hammes ME,Gray R,Lineberry B,Abrams B

    更新日期:1992-12-01 00:00:00

  • Acetate intolerance and an inhibitor of acetate utilization in hemodialysis patients.

    abstract::Diminished ability to utilize acetate (acetate intolerance) developed in a male patient on chronic hemodialysis after five years of maintenance dialysis. His ability to utilize lactate was also subnormal. We studied acetate metabolism in vitro by isolating lymphocytes from the patient's blood before dialysis and measu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Egan JD,Wells IC

    更新日期:1979-03-01 00:00:00

  • Reagent-free, simultaneous determination of serum cholesterol in HDL and LDL by infrared spectroscopy.

    abstract:BACKGROUND:The purpose of this study was to assess the feasibility of infrared (IR) spectroscopy for the simultaneous quantification of serum LDL-cholesterol (LDL-C) and HDL-cholesterol (HDL-C) concentrations. METHODS:Serum samples (n = 90) were obtained. Duplicate aliquots (5 microL) of the serum specimens were dried...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Liu KZ,Shaw RA,Man A,Dembinski TC,Mantsch HH

    更新日期:2002-03-01 00:00:00

  • A systematic approach to materials handling in clinical laboratories.

    abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nabb DP

    更新日期:1990-09-01 00:00:00

  • MALDI-TOF MS for the diagnosis of infectious diseases.

    abstract:BACKGROUND:First introduced into clinical microbiology laboratories in Europe, MALDI-TOF MS is being rapidly embraced by laboratories around the globe. Although it has multiple applications, its widespread adoption in clinical microbiology relates to its use as an inexpensive, easy, fast, and accurate method for identi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2014.221770

    authors: Patel R

    更新日期:2015-01-01 00:00:00

  • Primidone analyses: correlation of gas-chromatographic assay with enzyme immunoassay.

    abstract::Serum specimens from patients on primidone therapy were assayed by two currently available procedures: a commercially available enzyme immunoassay (EMIT) and a published gas-chromatographic procedure. Both procedures were done with commercially available materials and equipment. Results by the two procedures agreed we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sun L,Walwick ER

    更新日期:1976-06-01 00:00:00

  • Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

    abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127241

    authors: Kavsak PA,Wang X,Ko DT,MacRae AR,Jaffe AS

    更新日期:2009-10-01 00:00:00

  • Concentrations of zinc, iron, molybdenum, arsenic, and lithium in cerebrospinal fluid of patients with brain tumors.

    abstract::We used flameless atomic absorption spectrophotometry to measure concentrations of Fe, Mo, Li, As, and Zn in cerebrospinal fluid (CSF) of patients with malignant brain tumors benign brain tumors, non-brain malignant tumors and control (non-neoplastic disease) patients. Mean (and SD) concentrations (microgram/L) of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: el-Yazigi A,Al-Saleh I,Al-Mefty O

    更新日期:1986-12-01 00:00:00

  • Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: two techniques evaluated and modified for improved performance.

    abstract::We evaluated the EMIT (enzyme-multiplied immuno technique) and FPIA (fluorescence polarization immunoassay) urine screening systems for detection of benzodiazepine intake. Healthy male volunteers were given single oral therapeutic doses of alprazolam (2 mg), chlordiazepoxide (25 mg), flunitrazepam (1 mg), lorazepam (3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Beck O,Lafolie P,Hjemdahl P,Borg S,Odelius G,Wirbing P

    更新日期:1992-02-01 00:00:00

  • Sample preparation with ion-exchange resin before liquid-chromatographic determination of plasma catecholamines.

    abstract::Estimation of plasma catecholamine concentrations by "high-performance" liquid chromatography, although increasingly used, still presents difficulties. We describe a method for clean-up of plasma samples on cation-exchange resin before they are extracted with alumina. This procedure eliminates many of the interfering ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frayn KN,Maycock PF

    更新日期:1983-07-01 00:00:00

  • Analysis for lead in undiluted whole blood by tantalum ribbon atomic absorption spectrophotometry.

    abstract::We describe a modified tantalum ribbon atomic absorption procedure for determining lead in undiluted whole blood. An instrumentation Laboratory (I.L.) Model 151 atomic absorption spectrophotometer equipped with an I.L. Model 355 Flameless Sampler was used. The Flameless Sampler was slightly modified to include three-c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Therrell BL Jr,Drosche JM,Dziuk TW

    更新日期:1978-07-01 00:00:00

  • Detection of mitochondrial DNA mutations by temporal temperature gradient gel electrophoresis.

    abstract:BACKGROUND:A unique requirement for the molecular diagnosis of mitochondrial DNA (mtDNA) disorders is the ability to detect heteroplasmic mtDNA mutations and to distinguish them from homoplasmic sequence variations before further testing (e.g., sequencing) is performed. We evaluated the potential utility of temporal te...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Chen TJ,Boles RG,Wong LJ

    更新日期:1999-08-01 00:00:00

  • The journey to regulation of protein-based multiplex quantitative assays.

    abstract:BACKGROUND:Clinical proteomics presents great promise in biology and medicine because of its potential for improving our understanding of diseases at the molecular level and for detecting disease-related biomarkers for diagnosis, prognosis, and prediction of therapeutic responses. To realize its full potential to impro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.156034

    authors: Boja ES,Jortani SA,Ritchie J,Hoofnagle AN,Težak Ž,Mansfield E,Keller P,Rivers RC,Rahbar A,Anderson NL,Srinivas P,Rodriguez H

    更新日期:2011-04-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • Established and emerging markers of kidney function.

    abstract:BACKGROUND:The kidney performs a multitude of essential functions to maintain homeostasis. In clinical medicine, glomerular filtration rate (GFR) provides the best index of overall kidney function, and proteinuria adds additional information on renal and nonrenal prognosis. Several novel biomarkers of kidney injury and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2011.167494

    authors: Ferguson MA,Waikar SS

    更新日期:2012-04-01 00:00:00

  • Clinical evaluation of a radiometric assay specific for creatine kinase isoenzyme MB.

    abstract::A new radiometric assay specific for creatine kinase isoenzyme MB was evaluated with respect to its precision and agreement with a conventional electrophoretic CK-MB assay for the diagnosis of myocardial infarction. The reference interval we find for serum CK-MB in healthy subjects is 0--30 micrograms/L. The coefficie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kwong TC,Rothbard RL,Biddle TL

    更新日期:1981-06-01 00:00:00

  • Automated detection of inaccurate and imprecise transitions in peptide quantification by multiple reaction monitoring mass spectrometry.

    abstract:BACKGROUND:Multiple reaction monitoring mass spectrometry (MRM-MS) of peptides with stable isotope-labeled internal standards (SISs) is increasingly being used to develop quantitative assays for proteins in complex biological matrices. These assays can be highly precise and quantitative, but the frequent occurrence of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.138420

    authors: Abbatiello SE,Mani DR,Keshishian H,Carr SA

    更新日期:2010-02-01 00:00:00

  • Proficiency testing: purification of lactate dehydrogenase 1 and results of its use as a reference material in the New York State program.

    abstract::Highly purified human lactate dehydrogenase 1 has been used in an interlaboratory evaluation and improvement progran in clinical chemistry in New York State since 1971. Although there are difficulties in determining and assigning the most nearly accurate values for test samples in the absence of a reference method and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Copeland WH,Fasce CF Jr,Kowalski P,Richards AH,Vanderlinde RE

    更新日期:1977-06-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Computerized multicuvette system for single substance and group analysis and for the chromatographic isolation and quantitation of compounds in complex mixtures.

    abstract::A new computer-interfaced system of general applicability in the clinical laboratory has been built. The system is constructed around a new type multicuvette. Quantitation is currently by spectrophotometry and is on-line, with use of a mini-computer with output going to an electrostatic printer/plotter. The system can...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vestergaard P,Bachman A

    更新日期:1975-08-01 00:00:00

  • New reference intervals for thyrotropin and thyroid hormones based on National Academy of Clinical Biochemistry criteria and regular ultrasonography of the thyroid.

    abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.047399

    authors: Kratzsch J,Fiedler GM,Leichtle A,Brügel M,Buchbinder S,Otto L,Sabri O,Matthes G,Thiery J

    更新日期:2005-08-01 00:00:00

  • Ligase chain reaction assay for human mutations: the Sickle Cell by LCR assay.

    abstract::We can detect the beta-globin gene sickle cell mutation by using an assay based on the ligase chain reaction. The simultaneous amplification of the human growth hormone gene in the same reaction serves as a control for the amount of template DNA or amplification efficiency. Ligation products, which are biotinylated at...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Reyes AA,Carrera P,Cardillo E,Ugozzoli L,Lowery JD,Lin CI,Go M,Ferrari M,Wallace RB

    更新日期:1997-01-01 00:00:00

  • Dual-precipitation method evaluated for determination of high-density lipoprotein (HDL), HDL2, and HDL3 cholesterol concentrations.

    abstract::We evaluated a dual-precipitation method for determining cholesterol in high-density lipoprotein (HDL) and its subfractions HDL2 and HDL3. After total HDL was isolated by precipitation of very-low-density (VLDL) and low-density (LDL) lipoproteins with polyethylene glycol (Mr 8000), HDL2 was isolated from total HDL by ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dias VC,Parsons HG,Boyd ND,Keane P

    更新日期:1988-11-01 00:00:00

  • Microcalorimetric determination of glucose in reference samples of serum.

    abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Goldberg RN

    更新日期:1976-10-01 00:00:00

  • Measurement of the energy-generating capacity of human muscle mitochondria: diagnostic procedure and application to human pathology.

    abstract:BACKGROUND:Diagnosis of mitochondrial disorders usually requires a muscle biopsy to examine mitochondrial function. We describe our diagnostic procedure and results for 29 patients with mitochondrial disorders. METHODS:Muscle biopsies were from 43 healthy individuals and 29 patients with defects in one of the oxidativ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.062414

    authors: Janssen AJ,Trijbels FJ,Sengers RC,Wintjes LT,Ruitenbeek W,Smeitink JA,Morava E,van Engelen BG,van den Heuvel LP,Rodenburg RJ

    更新日期:2006-05-01 00:00:00