Primidone analyses: correlation of gas-chromatographic assay with enzyme immunoassay.

Abstract:

:Serum specimens from patients on primidone therapy were assayed by two currently available procedures: a commercially available enzyme immunoassay (EMIT) and a published gas-chromatographic procedure. Both procedures were done with commercially available materials and equipment. Results by the two procedures agreed well, which suggests that the two methods could be used interchangeably. For the 94 specimens studied, the correlation coefficient was 0.98, and the least-squares values of slope and intercept were, respectively, 0.97 and 0.51 mg/liter.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Sun L,Walwick ER

subject

Has Abstract

pub_date

1976-06-01 00:00:00

pages

901-2

issue

6

eissn

0009-9147

issn

1530-8561

journal_volume

22

pub_type

杂志文章
  • Felbamate measured in serum by two methods: HPLC and capillary electrophoresis.

    abstract::We have developed two methods for determining serum concentrations of felbamate, a new anticonvulsant drug. The first method is based on protein precipitation with acetonitrile, followed by HPLC. The between-run CV for this method is 5.7% (mean 55 mg/L), and the linearity extends from 5 to 175 mg/L. Results by this me...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,Oles KS

    更新日期:1994-10-01 00:00:00

  • Robotic chromatography: development and evaluation of automated instrumentation for assay of glycohemoglobin.

    abstract::The measurement of glycohemoglobin (GHb) by boronate affinity chromatography is useful in monitoring long-term glucose control in diabetic subjects. The inherent disadvantage of this method is the hands-on time required because the hemoglobin fractions are separated on individual disposable columns. To overcome this d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herold CD,Andree K,Herold DA,Felder RA

    更新日期:1993-01-01 00:00:00

  • Accuracy and comparability of long-term measurements of cholesterol.

    abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hainline A Jr,Karon JM,Winn CL,Gill JB

    更新日期:1986-04-01 00:00:00

  • Diagnosis of 5α-reductase 2 deficiency: is measurement of dihydrotestosterone essential?

    abstract:BACKGROUND:5α-Reductase 2 deficiency (5ARD) is a known cause of 46,XY disorders of sex development (DSD). Traditionally, the diagnosis relies on dihydrotestosterone (DHT) measurement, but the results are often equivocal, potentially leading to misdiagnosis. We reviewed alternative approaches for diagnosis of 5ARD. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.196501

    authors: Chan AO,But BW,Lee CY,Lam YY,Ng KL,Tung JY,Kwan EY,Chan YK,Tsui TK,Lam AL,Tse WY,Cheung PT,Shek CC

    更新日期:2013-05-01 00:00:00

  • RNA chip: quality assessment of RNA by microchannel linear gel electrophoresis in injection-molded plastic chips.

    abstract::Two major components of rRNA (18S and 28S rRNA) were separated by electrophoresis in injection-molded acrylic chips with a microchannel 100 microm in width, 40 microm in depth, and with 1 cm of separation distance. Microchannels were filled with 4 g/L hydroxypropylmethylcellulose as sieving polymer and 5 mg/L ethidium...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ogura M,Agata Y,Watanabe K,McCormick RM,Hamaguchi Y,Aso Y,Mitsuhashi M

    更新日期:1998-11-01 00:00:00

  • Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation.

    abstract::Noninvasive monitoring of blood/tissue glucose concentrations has been successfully accomplished in individual diabetic subjects by using near-infrared (NIR) spectroscopy coupled with chemometric methods. Three different spectrometer configurations were tested: a) a Fourier-transform infrared spectrometer with an indi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson MR,Eaton RP,Haaland DM,Koepp GW,Thomas EV,Stallard BR,Robinson PL

    更新日期:1992-09-01 00:00:00

  • Biological variation of lipids and lipoproteins in fingerstick blood.

    abstract::The biological variability of total cholesterol (TC), triglycerides (TG), high-density lipoprotein cholesterol (HDL-C), and calculated low-density lipoprotein cholesterol (LDL-C) was determined in three serial (monthly) capillary and venous specimens from 83 subjects. The analytes were quantified with a desktop analyz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kafonek SD,Donovan L,Lovejoy KL,Bachorik PS

    更新日期:1996-12-01 00:00:00

  • A computerized classification technique for screening for the presence of breath biomarkers in lung cancer.

    abstract::A simple computer-based screening technique has been developed for classifying human expired air components into 16 chemical classes, based on empirical formulas. The sort procedure was developed to simplify the screening of the composition of expired air samples by sorting all components into chemical classes and cla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: O'Neill HJ,Gordon SM,O'Neill MH,Gibbons RD,Szidon JP

    更新日期:1988-08-01 00:00:00

  • Evaluation of the IFCC-recommended procedure for serum aspartate aminotransferase as modified for use with the centrifugal analyzer.

    abstract::The IFCC-recommended procedure for aspartate aminotransferase (EC 2.6.1.1) was adapted to the centrifugal analyzer and evaluated during five years. The main hindrance to widespread use of the recommended method is the need for pre-incubation with pyridoxal phosphate. The present method includes a 10-min pre-incubation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Savory J,Titheradge AC,Cross RE,Wills MR

    更新日期:1981-01-01 00:00:00

  • Simplified radioimmunoassay of urinary drugs of abuse adsorbed on ion-exchange papers.

    abstract::A convenient screening procedure for presence of drugs of abuse in urine consists of two steps: adsorption of the drugs from urine onto a paper loaded with cation-exchange resin and detection of the adsorbed drugs by direct radioimmunoassay. The first step can be performed in the field, the second in a central laborat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alexander GJ,Machiz S

    更新日期:1977-10-01 00:00:00

  • A fully automated solid-phase radioimmunoassay for triiodothyronine.

    abstract::We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rugg NE,Hasler MJ,Bjornsen RE,Painter K

    更新日期:1977-05-01 00:00:00

  • Gas-liquid chromatographic profile of neutral and acidic metabolites in cerebrospinal fluid from newborns and infants.

    abstract::A profile (chromatographic pattern) of the neutral and acidic metabolites present in cerebrospinal fluid from newborns and infants was obtained by gas-liquid chromatography. The metabolites are those extracted with ethyl acetate and diethyl ether. They are converted to trimethylsilyl ether derivatives, and chromatogra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Malcolm RD,Leonards R

    更新日期:1976-05-01 00:00:00

  • Four methods for glucose assay compared for various glucose concentrations and under different clinical conditions.

    abstract::Glucose was measured by the ferricyanide, the Beckman glucose oxidase, and the hexokinase procedures in 228 plasma samples taken during standard oral glucose-tolerance tests in 17 normal subjects and in 21 chemical diabetics. The neocuproine method was also used to measure glucose concentration in 156 samples (78 befo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Giampietro O,Pilo A,Buzzigoli G,Boni C,Navalesi R

    更新日期:1982-12-01 00:00:00

  • Sensitivity of immunofixation electrophoresis for detecting IgM paraproteins in serum.

    abstract::Detection and characterization of small IgM paraproteins by immunoelectrophoresis are often difficult because of (a) slow diffusion of the macromolecular immunoglobulin, and (b) the obscuring of the light chain, especially kappa, by the light chains of background polyclonal immunoglobulin (the "umbrella effect"). Vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kahn SN,Bina M

    更新日期:1988-08-01 00:00:00

  • Application of a thermodynamic nearest-neighbor model to estimate nucleic acid stability and optimize probe design: prediction of melting points of multiple mutations of apolipoprotein B-3500 and factor V with a hybridization probe genotyping assay on the

    abstract:BACKGROUND:PCR-based mutation detection is prone to methodological errors, e.g., in restriction length fragment polymorphism (RFLP) and allele-specific amplification (ASA), false PCR results may occur because of technical faults or atypical new mutations. METHODS:We investigated the ability of a genotyping assay based...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Oellerich M,Armstrong VW,Schütz E

    更新日期:1999-12-01 00:00:00

  • Organic acids in urine from human newborns.

    abstract::The pattern of organic acids in urine from 15 normal newborn infants was investigated by gas chromatography/mass spectrometry of trimethylsilylated derivatives. The urine contains large amounts of succinic, fumaric, 2-ketoglutaric, and 3-hydroxy-3-methylglutaric acids, which are all fairly small components of urine fr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkman L,McLean C,Steen G

    更新日期:1976-01-01 00:00:00

  • Single-reagent polarization fluoroimmunoassay for barbiturates in urine.

    abstract::We describe a rapid polarization fluoroimmunoassay for screening for the presence of barbiturates in urine. The single reagent is prepared by pre-mixing antiserum with a fluorescein-labeled barbiturate derivative as tracer. Use of a mixture of two sheep antisera, raised against different barbiturate immunogens, result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Smith DS,Landon J,Sidki AM

    更新日期:1984-11-01 00:00:00

  • Hydroxyurea interferes negatively with triglyceride measurement by a glycerol oxidase method.

    abstract::Measured triglyceride concentrations were extremely low (less than 100 mg/L) in the serum of some patients who were receiving hydroxyurea for myeloproliferative diseases. The assay being used to quantify triglycerides was a "cascaded" enzymatic method involving (a) lipase, to generate glycerol from triglycerides; (b) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McPherson RA,Brown KD,Agarwal RP,Threatte GA,Jacobson RJ

    更新日期:1985-08-01 00:00:00

  • Dried plasma spot measurements of ferritin and transferrin receptor for assessing iron status.

    abstract:BACKGROUND:Efforts to reduce the high global prevalence of nutritional anemia require the use of both reliable laboratory assays to distinguish iron deficiency from other causes of anemia and cost-effective methods for collection of blood specimens under field conditions. The suitability of using small plasma samples s...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Flowers CH,Cook JD

    更新日期:1999-10-01 00:00:00

  • Automated measurement of amylase isoenzymes by a double kinetic assay with "blocked" beta-2-chloro-4-nitrophenyl maltopentaoside as substrate and with wheat germ inhibitor.

    abstract::We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Nishimura T,Noma A,Hamano K

    更新日期:1991-08-01 00:00:00

  • Reduced bovine hemoglobin solution evaluated for use as a blood gas quality-control material.

    abstract::We evaluated a new commercially available partially purified reduced bovine hemoglobin solution (RBHS) and a new tonometer for use in the quality control of blood gas analyzers. RBHS is manufactured in three different formulations, each corresponding to three different bicarbonate-buffering capacities and concentratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mahoney JJ,Wong RJ,Van Kessel AL

    更新日期:1993-05-01 00:00:00

  • Endotoxin binding to platelets in blood from patients with a sepsis syndrome.

    abstract::Endotoxin, the lipopolysaccharide cell wall constituent of Gram-negative bacteria, produces symptoms of the Gram-negative sepsis syndrome. By measuring endotoxin in blood from septic patients it may be possible to select a subpopulation of patients in which mortality can be prevented by treatment with anti-endotoxin a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Salden HJ,Bas BM

    更新日期:1994-08-01 00:00:00

  • Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    abstract:BACKGROUND:In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.067116

    authors: Sauvage FL,Saint-Marcoux F,Duretz B,Deporte D,Lachatre G,Marquet P

    更新日期:2006-09-01 00:00:00

  • Capillary electrophoresis for detection of inherited disorders of purine and pyrimidine metabolism.

    abstract:BACKGROUND:Measurement of purine and pyrimidine metabolites presents complex problems for separations currently performed by HPLC and thin-layer chromatography in clinical practice. We developed a novel capillary electrophoresis method for this purpose. METHODS:Separations were performed in 60 mmol/L borate-2-amino-2-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adam T,Friedecký D,Fairbanks LD,Sevcík J,Barták P

    更新日期:1999-12-01 00:00:00

  • LC-MS/MS Measurement of Parathyroid Hormone-Related Peptide.

    abstract:INTRODUCTION:Parathyroid hormone-related peptide (PTHrP) is involved in activating pathways, allowing tumor cells to form bone metastases. Measurement of PTHrP is used for the diagnosis and clinical management of patients suspected of hypercalcemia of malignancy. We developed an LC-MS/MS method for measuring PTHrP, est...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244012

    authors: Kushnir MM,Rockwood AL,Strathmann FG,Frank EL,Straseski JA,Meikle AW

    更新日期:2016-01-01 00:00:00

  • Values for some serum analytes in high-risk infants, two days postpartum.

    abstract::Using a continuous-flow (Technicon SMAC) analyzer, we measured the concentration of 20 analytes in capillary blood sera from 149 neonates in an intensive-care unit. Included were term and pre-term babies, both groups with and without asphyxia. The values obtained, especially for those enzymes and analytes that are rel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fitzsimons EJ,Fletcher MA,Chakrin A

    更新日期:1984-04-01 00:00:00

  • Immunoradiometric serum ferritin concentration compared with stainable bone-marrow iron as indices to iron stores.

    abstract::Immunoradiometric analysis has made it possible to measure ferritin reliably in serum. The determination is a sensitive means of assessing body iron because concentrations of ferritin closely parallel the body's reticuloendothelial iron stores. The information provided is similar to that obtained from bone-marrow aspi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Forman DT,Vye MV

    更新日期:1980-01-01 00:00:00

  • Up-dated catalogue of HeLa cell proteins: percentages and characteristics of the major cell polypeptides labeled with a mixture of 16 14C-labeled amino acids.

    abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bravo R,Celis JE

    更新日期:1982-04-01 00:00:00

  • Vitamin C and glycohemoglobin.

    abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Weykamp CW,Penders TJ,Baadenhuijsen H,Muskiet FA,Martina W,van der Slik W

    更新日期:1995-05-01 00:00:00

  • Use of natriuretic peptides to guide and monitor heart failure therapy.

    abstract:BACKGROUND:Plasma B-type cardiac natriuretic peptides reflect cardiac structure and function and have proven roles in assisting in the diagnosis of acute heart failure. They are independent prognostic indicators across the full spectrum of cardiovascular disease. Serial changes in plasma B-type cardiac natriuretic pept...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2011.165704

    authors: Richards AM,Troughton RW

    更新日期:2012-01-01 00:00:00