A fully automated solid-phase radioimmunoassay for triiodothyronine.

Abstract:

:We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in rabbits, purified by ammonium sulfate precipitation, and coated onto polypropylene tubes. Analytical recovery of exogenous triiodothyronine added to sera from normal men and women and pregnant women was quantitative. Intra-assay and inter-assay coefficients of variation are 4-5 and 6-9%, respectively. Correlation coefficients (r) for comparison of sample values with those obtained by three commercial laboratories were 0.95, 0.84, and 0.91. The sensitivity of the assay is 0.5 microng/liter. The assay can be performed either manually or be fully automated on the "Concept 4."

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Rugg NE,Hasler MJ,Bjornsen RE,Painter K

subject

Has Abstract

pub_date

1977-05-01 00:00:00

pages

851-4

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

23

pub_type

杂志文章
  • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay.

    abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.057216

    authors: Lam Q,Black M,Youdell O,Spilsbury H,Schneider HG

    更新日期:2006-02-01 00:00:00

  • Automated measurement of urinary iodine with use of ultraviolet irradiation.

    abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuda K,Namba H,Nomura T,Yokoyama N,Yamashita S,Izumi M,Nagataki S

    更新日期:1995-04-01 00:00:00

  • Laboratory diagnosis of Bence Jones proteinuria in a patient with plasma cell leukemia.

    abstract::Kappa Bence Jones proteinuria was found by immunoelectrophoretic techniques in a patient with plasma cell leukemia, who presented with no M-proteins either in serum or urine. However, a significant decrease in normal immunoglobulins was observed. On microscopic examination of kidney sections obtained a autopsy, protei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chow C,Spitzer RW

    更新日期:1975-10-01 00:00:00

  • Improved biuret procedure for routine determination of urinary total proteins in clinical proteinuria.

    abstract::This communication describes and evaluates an improved routine methodology for quantitating clinical proteinuria. Based on investigations of Piscator and of Savory et al., a modified Tsuchiya's reagent (ethanolic HCI-phosphotungstic acid) is used to precipitate proteins at 56 degrees C, followed by biuret spectrophoto...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rice EW

    更新日期:1975-03-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00

  • Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

    abstract:BACKGROUND:The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.242081

    authors: Jarolim P,Patel PP,Conrad MJ,Chang L,Melenovsky V,Wilson DH

    更新日期:2015-10-01 00:00:00

  • Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

    abstract::With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Voelter W,Bauer H

    更新日期:1975-12-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • Comparison of a logistic and a mass-action curve for radioimmunoassay data.

    abstract::This paper compares a logistic curve and a mass-action curve in their ability to represent radioimmunoassay standard curves. A data base from 10 different assays is used in this comparison. Six of the 10 assays could be modeled equally well by either the logistic or the mass-action curve. In one case the mass-action c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raab GM

    更新日期:1983-10-01 00:00:00

  • Performance of an enzyme-linked immunosorbent assay system for antibodies to hepatitis C virus with two new antigens (c11/c7).

    abstract::We developed an enzyme-linked immunosorbent assay (ELISA) system for antibodies to the hepatitis C virus (HCV), using two new recombinant antigens (c11 and c7) derived from the HCV genome. The performance of this ELISA system (Imucheck HCV Ab) was examined. The CV values for both intra-assay precision and reproducibil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Saito M,Hasegawa A,Kashiwakuma T,Kohara M,Sugi M,Miki K,Yamamoto T,Mori H,Ohta Y,Tanaka E

    更新日期:1992-12-01 00:00:00

  • Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation.

    abstract::Noninvasive monitoring of blood/tissue glucose concentrations has been successfully accomplished in individual diabetic subjects by using near-infrared (NIR) spectroscopy coupled with chemometric methods. Three different spectrometer configurations were tested: a) a Fourier-transform infrared spectrometer with an indi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson MR,Eaton RP,Haaland DM,Koepp GW,Thomas EV,Stallard BR,Robinson PL

    更新日期:1992-09-01 00:00:00

  • Development of a rapid and sensitive immunofluorometric assay for glutathione S-transferase A.

    abstract:BACKGROUND:The short half-life of the alpha-class glutathione S-transferases (GSTAs) in plasma combined with their even distribution throughout the liver lobule suggests that they may be useful complements to the more traditionally used liver markers. However, the currently available assays for measuring GSTAs in biolo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dajani LK,Paus E,Warren DJ

    更新日期:2001-05-01 00:00:00

  • Partition affinity ligand assay (PALA) for quantitation of triiodothyronine in serum.

    abstract::Radioimmunoassay of triiodothyronine was performed with a homogeneous incubation system. Bound and free ligand were separated by partitioning in an aqueous two-phase system. The agreement between the results obtained with this technique and conventional heterogeneous radioimmunoassay was very good (r = 0.981). ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mattiasson B,Eriksson H

    更新日期:1982-04-01 00:00:00

  • Hyperamylasemia, specific pancreatic enzymes, and hypoxanthine during recovery from diabetic ketoacidosis.

    abstract::The contribution of the exocrine pancreas to hyperamylasemia in diabetic ketoacidosis was investigated by measuring total amylase, salivary and pancreatic isoamylases, cathodic trypsin-like immunoreactivity, and pancreatic lipase in 12 consecutive patients recovering from diabetic ketoacidosis. Hyperamylasemia was pre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Møller-Petersen J,Andersen PT,Hjørne N,Ditzel J

    更新日期:1985-12-01 00:00:00

  • Systematic Review and Metaanalysis Comparing the Bias and Accuracy of the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration Equations in Community-Based Populations.

    abstract:BACKGROUND:The majority of patients with chronic kidney disease are diagnosed and monitored in primary care. Glomerular filtration rate (GFR) is a key marker of renal function, but direct measurement is invasive; in routine practice, equations are used for estimated GFR (eGFR) from serum creatinine. We systematically a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2017.276683

    authors: McFadden EC,Hirst JA,Verbakel JY,McLellan JH,Hobbs FDR,Stevens RJ,O'Callaghan CA,Lasserson DS

    更新日期:2018-03-01 00:00:00

  • Laboratory diagnosis of specific antibody deficiency to pneumococcal capsular polysaccharide antigens.

    abstract:BACKGROUND:Measurement of postimmunization antibody response to pneumococcal capsular polysaccharide (caps-PS) is the standard method to identify deficiency of antipolysaccharide antibody production. However, no standardized criteria have been defined for classification of patients into responders or nonresponders to c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.080051

    authors: Jeurissen A,Moens L,Raes M,Wuyts G,Willebrords L,Sauer K,Proesmans M,Ceuppens JL,De Boeck K,Bossuyt X

    更新日期:2007-03-01 00:00:00

  • Plasma protein abnormalities in nephrotic syndrome: effect on plasma colloid osmotic pressure and viscosity.

    abstract::The concentrations of 25 plasma proteins were measured in 22 patients with membranous nephropathy. For some large proteins, the plasma concentrations were increased; there were also large proteins with low plasma concentrations, but small or medium-sized proteins showed uniformly lower plasma concentration than the co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Joven J,Clivillé X,Camps J,Espinel E,Simó J,Vilella E,Oliver A

    更新日期:1997-07-01 00:00:00

  • Decreasing sample volume used in the "Sequential Multichannel Analyzer Computerized" (SMAC).

    abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stamper R,Robertshaw DM

    更新日期:1980-05-01 00:00:00

  • Direct ultraviolet method for enzymatic determination of uric acid, with equilibrium and kinetic data-processing options.

    abstract::We developed and evaluated a direct ultraviolet method for the enzymatic determination of uric acid in serum, plasma, or urine, without deproteinization of sera and plasma. Equilibrium and nonlinear curve-fitting kinetic options are evaluated and compared, and results of the proposed method are compared with those of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dilena BA,Peake MJ,Pardue HL,Skoug JW

    更新日期:1986-03-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Ten commercial kits compared for assay of thyrotropin in the normal and thyrotoxic range.

    abstract::I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly supe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Evans MC

    更新日期:1988-01-01 00:00:00

  • Influence of autoantibodies to creatine kinase-BB on assays for MB isoenzyme.

    abstract::We describe the influence of autoantibodies that bind creatine kinase BB (CK-BB) on the methods for MB isoenzyme. If these autoantibodies are present in patients' sera, they cause the formation of macro CK type 1 (immunoglobulin-linked CK-BB). In some of these cases they can bind not only endogenous CK-BB but also CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stein W,Bohner J

    更新日期:1985-07-01 00:00:00

  • Micro-scale method for theophylline in body fluids by reversed-phase, high-pressure liquid chromatography.

    abstract::We describe a micro-scale method for determining serum theophylline. The chromatography system includes a muBondapack C18 column and acetonitrile, 70 ml/liter of sodium acetate buffer (10 mmol/liter, ph 4.0) as the mobile phase. Test serum or plasma, 30 mul, is mixed with an equal quantity of a solution containing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orcutt JJ,Kozak PP Jr,Gillman SA,Cummins LH

    更新日期:1977-03-01 00:00:00

  • Development and evaluation of quality control dried blood spot materials in newborn screening for lysosomal storage disorders.

    abstract:BACKGROUND:Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111864

    authors: De Jesus VR,Zhang XK,Keutzer J,Bodamer OA,Mühl A,Orsini JJ,Caggana M,Vogt RF,Hannon WH

    更新日期:2009-01-01 00:00:00

  • Comparative costs of treating adults and children within selected diagnosis-related groups.

    abstract:BACKGROUND:There have been no large-scale analyses of resource utilization comparing the overall costs to treat pediatric patients vs adult patients. Likewise, there have been no studies evaluating the costs of the various components of hospitalization (e.g., accommodation, laboratory, radiology, and drugs) among adult...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Young DS,Sachais BS,Jefferies LC

    更新日期:2002-01-01 00:00:00

  • Improved separation of creatine kinase cardiac isoenzyme in serum by batch fractionation.

    abstract::I describe a simple, single-tube batch fractionation procedure for separating MM and MB isoenzymes of creatine kinase on a macroporous strong anion exchanger (AG MP-1, Bio-Rad Laboratories). The isoenzymes can be separated in less than 3 min, with a resulting dilution of the serum with no more than an equal volume of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morin LG

    更新日期:1976-01-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00

  • Coffee consumption and circulating B-vitamins in healthy middle-aged men and women.

    abstract:BACKGROUND:Coffee consumption has been associated with several risk factors for coronary heart disease, including increased cholesterol, increased blood pressure, and increased plasma total homocysteine (tHcy). tHcy is determined by several B-vitamins. However, reports about the association between coffee intake and B-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103465

    authors: Ulvik A,Vollset SE,Hoff G,Ueland PM

    更新日期:2008-09-01 00:00:00

  • Colorimetry of angiotensin-I converting enzyme activity in serum.

    abstract::This simple, accurate, and reproducible colorimetric method for determining the activity of angiotensin-I converting enzyme is based upon colorimetry of the quinoneimine dye produced from the substrate p-hydroxyhippuryl-L-histidyl-L-leucine by action of this enzyme through the following series of reactions. The enzyme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kasahara Y,Ashihara Y

    更新日期:1981-11-01 00:00:00

  • Preparation of whole blood for liquid scintillation counting.

    abstract::Liquid scintillation counting of 3H-labeled whole-blood samples is severely impaired owing to quenching by blood pigments. In this study, dry oxidation and chemical solubilization followed by decolorization were the two general methods used to eliminate color quenching. Three blood volumes were examined: 0.25, 0.50, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore PA

    更新日期:1981-04-01 00:00:00