Laboratory diagnosis of specific antibody deficiency to pneumococcal capsular polysaccharide antigens.

Abstract:

BACKGROUND:Measurement of postimmunization antibody response to pneumococcal capsular polysaccharide (caps-PS) is the standard method to identify deficiency of antipolysaccharide antibody production. However, no standardized criteria have been defined for classification of patients into responders or nonresponders to caps-PS. METHODS:We vaccinated 37 healthy children and 39 healthy adults with Pneumovax and measured the anti-caps-PS antibody response to 5 serotypes. We also measured antipneumococcal antibody titers in 82 patients with increased susceptibility to airway infection. The ELISA was performed according to the 3rd-generation assay format. RESULTS:The lower 5th percentile (cutoff) concentrations for the postimmunization antibody titer in healthy individuals were 0.67 mg/L, 0.45 mg/L, 0.46 mg/L, 0.31 mg/L, and 1.04 mg/L for serotypes 3, 4, 9N, 18C, and 19F, respectively. In 96% of healthy individuals, antibody responses higher than the cutoff concentration were seen for at least 3 of the 5 serotypes. Nine of 82 patients (11%) failed to mount an adequate antibody response for at least 4 of the 5 serotypes tested, whereas only 1 control (1.3%) failed to do so. CONCLUSION:The cutoffs for antibody responses to caps-PS identified in this study appear useful for identifying individuals with an inadequate response to vaccine.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Jeurissen A,Moens L,Raes M,Wuyts G,Willebrords L,Sauer K,Proesmans M,Ceuppens JL,De Boeck K,Bossuyt X

doi

10.1373/clinchem.2006.080051

subject

Has Abstract

pub_date

2007-03-01 00:00:00

pages

505-10

issue

3

eissn

0009-9147

issn

1530-8561

pii

clinchem.2006.080051

journal_volume

53

pub_type

杂志文章
  • Diagnosis of hemolytic disease by electrophoresis of erythrocyte lactate dehydrogenase isoenzymes on cellulose acetate or Agarose.

    abstract::We determined the LD-1/LD-2 isoenzyme ratio in hemolysates of erythrocytes by electrophoresis on cellulose acetate and on agarose. A ratio exceeding 1.0 was found with the former but not the latter. Results were similar for in vitro models of hemolytic disorders. Using cellulose acetate electrophoresis, we determined ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Marchand A,Galen RS

    更新日期:1981-08-01 00:00:00

  • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.

    abstract::We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bergqvist Y,Eckerbom S,Funding L

    更新日期:1984-03-01 00:00:00

  • Genotype-specific signal generation based on digestion of 3-way DNA junctions: application to KRAS variation detection.

    abstract:BACKGROUND:Genotyping methods that reveal single-nucleotide differences are useful for a wide range of applications. We used digestion of 3-way DNA junctions in a novel technology, OneCutEventAmplificatioN (OCEAN) that allows sequence-specific signal generation and amplification. We combined OCEAN with peptide-nucleic-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.068817

    authors: Amicarelli G,Adlerstein D,Shehi E,Wang F,Makrigiorgos GM

    更新日期:2006-10-01 00:00:00

  • Tentacle Probes: differentiation of difficult single-nucleotide polymorphisms and deletions by presence or absence of a signal in real-time PCR.

    abstract:BACKGROUND:False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation dif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.091488

    authors: Satterfield BC,Kulesh DA,Norwood DA,Wasieloski LP Jr,Caplan MR,West JA

    更新日期:2007-12-01 00:00:00

  • Specific determination of beta-galactocerebrosidase activity via competitive inhibition of beta-galactosidase.

    abstract:BACKGROUND:The determination of cellular beta-galactocerebrosidase activity is an established procedure to diagnose Krabbe disease and monitor the efficacy of gene/stem cell-based therapeutic approaches aimed at restoring defective enzymatic activity in patients or disease models. Current biochemical assays for beta-ga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.115873

    authors: Martino S,Tiribuzi R,Tortori A,Conti D,Visigalli I,Lattanzi A,Biffi A,Gritti A,Orlacchio A

    更新日期:2009-03-01 00:00:00

  • Ten electrophoretic methods compared with a selected method for quantifying lactate dehydrogenase isoenzymes in serum.

    abstract::Using the Selected Method of McKenzie and Henderson (Selected Methods Clin Chem 1983;10:59-67) as a reference method, we compared the performance of 10 commercially available methods for determination of lactate dehydrogenase (LD, EC 1.1.1.27) isoenzymes. Results were expressed as percentage of total LD activity, as d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moses GC,Ross ML,Henderson AR

    更新日期:1988-09-01 00:00:00

  • Immunoluminometric assay for measurement of the C-terminal endothelin-1 precursor fragment in human plasma.

    abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065581

    authors: Papassotiriou J,Morgenthaler NG,Struck J,Alonso C,Bergmann A

    更新日期:2006-06-01 00:00:00

  • Quantifying spurious free T4 results attributable to thyroxine-binding proteins in serum dialysates and ultrafiltrates.

    abstract:BACKGROUND:Direct equilibrium dialysis and direct ultrafiltration free thyroxine (T(4)) assays rely on semipermeable membranes to exclude T(4)-binding serum proteins from dialysates and ultrafiltrates. The presence of these proteins in dialysates or ultrafiltrates will yield spuriously high free T(4) values when free T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.085316

    authors: Fritz KS,Wilcox RB,Nelson JC

    更新日期:2007-05-01 00:00:00

  • A direct radioimmunoassay for aldosterone in unextracted serum and plasma.

    abstract::We describe a novel radioimmunoassay procedure for the direct estimation of aldosterone in unextracted plasma and serum samples, in which interfering binding proteins are digested by Proteinase K (Tritirachium alkaline proteinase, EC 3.4.21.14), a powerful proteolytic enzyme. Heating at 75 degrees C for 15 min inactiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lee TP,Tan CH

    更新日期:1981-12-01 00:00:00

  • Assay of delta-aminolaevulinate dehydratase in 10 microL of blood.

    abstract::A method is presented for the assay of delta-aminolaevulinate dehydratase (EC 4.2.1.24) to be performed on 10 microL of whole blood. Results compare favorably with those obtained with an accepted method (J. Clin. Chem. Clin. Bio-chem. 12: 389-390, 1974) that involves use of 200 microL of blood. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wigfield DC,Farant JP

    更新日期:1981-01-01 00:00:00

  • Measurement of hemoglobin A1 by liquid chromatography and by agar gel electrophoresis compared.

    abstract::We compare measurement of total fast hemoglobin (HbA1) by "high-performance" liquid chromatography and by electrophoresis on agar gel. Blood samples were obtained from a diverse population (n = 222): offspring of two diabetic parents, diabetic patients with and without retinopathy, diabetic and non-diabetic pregnant w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hayes EJ,Gleason RE,Soeldner JS,Wacks M,Blankstein L

    更新日期:1981-03-01 00:00:00

  • Changes in magnesium, zinc, calcium, potassium, cholesterol, and creatine kinase concentrations in patients from pre-infarction syndrome to fatal myocardial infarction.

    abstract::We measured changes in concentrations of magnesium, zinc, calcium, potassium, cholesterol [total and high-density lipoproteins (HDL)], total creatine kinase (CK), and CK isoenzyme-MB in plasma (PI) and/or erythrocytes (Erc) from apparently healthy subjects and from patients with either pre-infarction syndrome (PIS) or...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Speich M,Gelot S,Arnaud P,Nicolas G

    更新日期:1988-10-01 00:00:00

  • Simultaneous determination of 6-thioguanine and methyl 6-mercaptopurine nucleotides of azathioprine in red blood cells by HPLC.

    abstract::6-thioguanine (6-TGN) and methyl 6-mercaptopurine nucleotides (Me6-MPNs) are the two major metabolites found in erythrocytes after administration of azathioprine. In an attempt to understand the role of these metabolites in the pharmacologic and toxic activity of thiopurines, we have developed a HPLC method for the si...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dervieux T,Boulieu R

    更新日期:1998-03-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Glycated proteins in serum: effect of their relative proportions on their alkaline reducing activity in the fructosamine test.

    abstract::The fructosamine test is considered clinically useful for assessing short-term integrated control of blood glucose, but there are few published data to support this hypothesis. We fractionated glycated and nonglycated proteins by affinity chromatography on phenylboronate columns and, with specific immunochemical metho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zoppi F,Mosca A,Granata S,Montalbetti N

    更新日期:1987-10-01 00:00:00

  • Adenosine deaminase binding protein, a new diagnostic marker for kidney disease.

    abstract::This enzyme immunoassay detects adenosine deaminase binding protein (ABP), a glycoprotein that is shed from the brush border of the proximal tubule in kidney damage. Two monoclonal antibodies, URO-4 and URO-4a, each react with different epitopes on ABP and are used as the "sandwich" pair of antibodies. A linear standa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson RE,Piper DJ,Galberg C,Chan TH,Tolkoff-Rubin NE,Rubin RH

    更新日期:1985-05-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Evaluation of the IFCC-recommended procedure for serum aspartate aminotransferase as modified for use with the centrifugal analyzer.

    abstract::The IFCC-recommended procedure for aspartate aminotransferase (EC 2.6.1.1) was adapted to the centrifugal analyzer and evaluated during five years. The main hindrance to widespread use of the recommended method is the need for pre-incubation with pyridoxal phosphate. The present method includes a 10-min pre-incubation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Savory J,Titheradge AC,Cross RE,Wills MR

    更新日期:1981-01-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Simultaneous detection of high-sensitivity cardiac troponin I and myoglobin by modified sandwich lateral flow immunoassay: proof of principle.

    abstract:BACKGROUND:Although numerous lateral flow immunoassays (LFIAs) have been developed and widely used, inadequate analytical sensitivity and the lack of multiple protein detection applications have limited their clinical utility. We developed a new LFIA device for the simultaneous detection of high-sensitivity cardiac tro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.171694

    authors: Zhu J,Zou N,Zhu D,Wang J,Jin Q,Zhao J,Mao H

    更新日期:2011-12-01 00:00:00

  • Incubation with neuraminidase and affinity electrophoresis with wheat-germ lectin compared for separating and quantifying alkaline phosphatase isoenzymes in plasma.

    abstract::Of 98 patients' specimens examined for alkaline phosphatase (EC 3.1.3.1) isoenzymes by electrophoresis on cellulose acetate membrane after incubation with neuraminidase, 50 showed only a single liver or bone isoenzyme staining band; in 15 of these, the tissue origin of the fraction could not be accurately identified f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY

    更新日期:1985-07-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Time-course of cigarette smoke contamination of clinical hydrogen breath-analysis tests.

    abstract::The time-course of the contamination of exogenous hydrogen from cigarette smoke on postprandial breath hydrogen concentration was evaluated in 10 subjects, six regular smokers and four occasional smokers. Breath hydrogen values were determined by gas chromatography 10 min, 5 min, and immediately prior to smoking a fil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosenthal A,Solomons NW

    更新日期:1983-11-01 00:00:00

  • Quantitative real-time PCR method for detection of B-lymphocyte monoclonality by comparison of kappa and lambda immunoglobulin light chain expression.

    abstract:BACKGROUND:An abnormal IgLkappa:IgLlambda ratio has long been used as a clinical criterion for non-Hodgkin B-cell lymphomas. As a first step toward a quantitative real-time PCR-based multimarker diagnostic analysis of lymphomas, we have developed a method for determination of IgLkappa:IgLlambda ratio in clinical sample...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.1.51

    authors: Ståhlberg A,Aman P,Ridell B,Mostad P,Kubista M

    更新日期:2003-01-01 00:00:00

  • Multi-channel, probe colorimeter for use with the micr-ELISA test, which makes use of disposable flat-bottom microhemagglutination plates.

    abstract::We describe a multiprobe colorimeter that permits the reading of enzyme-linked immunosorbent assays (ELISA) in situ, by use of microhemagglutination plates. The use of dipping probes eliminates interference from meniscus effects and air-bubble entrapment. Detailed validation tests have been done and potential sources ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McMurray CH,Blanchflower WJ

    更新日期:1979-04-01 00:00:00

  • Angiotensin-converting enzyme determination in plasma during therapy with converting enzyme inhibitor: two methods compared.

    abstract::For normal and above-normal concentrations of angiotensin-converting enzyme (ACE; EC 3.4.15.1) activity in plasma, results of a manual fluorometric method [with hippuryl-histidyl-leucine (HHL), 5 mmol/L, as substrate] correlated well with those of an automated spectrophotometric method [with 3-(2-furylacryloyl)-L-phen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gorski TP,Campbell DJ

    更新日期:1991-08-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Real-time PCR assays targeting a unique chromosomal sequence of Yersinia pestis.

    abstract:BACKGROUND:Yersinia pestis, the causative agent of the zoonotic infection plague, is a major concern as a potential bioweapon. Current real-time PCR assays used for Y. pestis detection are based on plasmid targets, some of which may generate false-positive results. METHODS:Using the yp48 gene of Y. pestis, we designed...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051839

    authors: Chase CJ,Ulrich MP,Wasieloski LP Jr,Kondig JP,Garrison J,Lindler LE,Kulesh DA

    更新日期:2005-10-01 00:00:00

  • Development of a stable reference material for prostatic acid phosphatase.

    abstract::We describe the development of a stable reference material for prostatic acid phosphatase, derived from human prostatic tissue and human seminal fluid. The enzyme was purified by an L-tartramic acid affinity-chromatography technique. Two-dimensional electrophoresis revealed essentially no contaminating proteins, and s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duncan PH,Van Etten RL,MacNeil ML,Shaw LM

    更新日期:1984-08-01 00:00:00

  • Liquid-chromatographic determination of free and total 3,4-dihydroxyphenylglycol and 3-methoxy-4-hydroxyphenylglycol in urine.

    abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Julien C,Rodriguez C,Sacquet J,Cuisinaud G,Sassard J

    更新日期:1988-05-01 00:00:00