Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

Abstract:

:A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injection), linear (r greater than 0.999 for concentrations ranging between 45 and 112,500 pmol per 100-microL injection), and reproducible (mean CVs for three different concentrations of standards and a serum pool ranged from 4.4% to 12.2%). In rats treated for three days with either neomycin, carbon tetrachloride, alpha-naphthylisothiocyanate, or total bile-duct ligation (five animals per group), total concentrations of bile acids were significantly increased (P less than 0.004). Concentrations of 16 of 17 individual bile acids differed significantly between groups (P less than 0.04). Examination of the relative concentrations (percent of total) of individual bile acids by canonical discriminant analysis placed each animal into the appropriate treatment or control group. Use of this technique in toxicological studies can help detect and identify specific types of disruptions in the enterohepatic circulation of bile acids.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

subject

Has Abstract

pub_date

1987-10-01 00:00:00

pages

1856-62

issue

10

eissn

0009-9147

issn

1530-8561

journal_volume

33

pub_type

杂志文章
  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Variability in the relationship between mean plasma glucose and HbA1c: implications for the assessment of glycemic control.

    abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.079756

    authors: Kilpatrick ES,Rigby AS,Atkin SL

    更新日期:2007-05-01 00:00:00

  • In vitro effects of a novel hemoglobin-based oxygen carrier on routine chemistry, therapeutic drug, coagulation, hematology, and blood bank assays.

    abstract::Red blood cell (RBC) replacement solutions are being developed as alternatives to allogeneic RBC use in blood transfusions in the treatment of massive trauma, to achieve hemodynamic stability during elective surgery, and to increase oxygen-carrying capacity in anemia. Hemoglobin-based oxygen carrier (HBOC)-201 (Biopur...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Callas DD,Clark TL,Moreira PL,Lansden C,Gawryl MS,Kahn S,Bermes EW Jr

    更新日期:1997-09-01 00:00:00

  • A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

    abstract::A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Riad-Fahmy D,Read GF,Gaskell SJ,Dyas J,Hindawi R

    更新日期:1979-05-01 00:00:00

  • Analytical and clinical performance goals for testing autoantibodies to thyroperoxidase, thyroglobulin, and thyrotropin receptor.

    abstract::Methods for measuring thyroid autoantibodies--to thyroperoxidase (TPOAb), thyroglobulin (TgAb), and thyrotropin receptor (TRAb)--have improved over the last decade, but increasingly, accurate and sensitive methods are needed for identifying patients with autoimmune thyroid diseases and individuals at high risk for ons...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Feldt-Rasmussen U

    更新日期:1996-01-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Results compared for tricyclic antidepressants as assayed by liquid chromatography and enzyme immunoassay.

    abstract::The tricyclic antidepressants amitriptyline, nortriptyline, imipramine, and desipramine in serum of patients taking one of the drugs were quantified in two laboratories by high-performance liquid chromatography (HPLC) and enzyme-multiplied immunoassay (EMIT; Syva). Results for split samples were highly correlated, but...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dorey RC,Preskorn SH,Widener PK

    更新日期:1988-11-01 00:00:00

  • Data Normalization Strategies for MicroRNA Quantification.

    abstract:BACKGROUND:Different technologies, such as quantitative real-time PCR or microarrays, have been developed to measure microRNA (miRNA) expression levels. Quantification of miRNA transcripts implicates data normalization using endogenous and exogenous reference genes for data correction. However, there is no consensus ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239459

    authors: Schwarzenbach H,da Silva AM,Calin G,Pantel K

    更新日期:2015-11-01 00:00:00

  • Evaluation of two digoxin radioimmunoassay procedures in which 125I-labeled digoxin is used.

    abstract::We present a comparative evaluation of two commercial kits, the "Quantitope" and "GammaCoat," for radioimmunoassay of digoxin in serum. These kits, in which iodine-125 is used as a label, proved to suitable for digoxin assay as determined by their reproducibility, sensitivity, precision, and a regression analysis. Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuczala ZJ,Ahluwalia GS

    更新日期:1976-02-01 00:00:00

  • Findings of an external quality assessment scheme for determining aluminum in dialysis fluids and water.

    abstract::The analytical performance of laboratories participating in the dialysis fluids and water aluminum program of the Guildford External Quality Assessment Scheme over the period 1986-1993 has been reviewed. For aluminum concentrations > 3.33 mumol/L in dialysis fluids, the between-laboratory CV has fallen from approximat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taylor A,Briggs RJ,Cevik C

    更新日期:1994-08-01 00:00:00

  • Influence of O.C.T. embedding compound on determinations of estrogen and progestin receptors in breast cancer.

    abstract::Estrogen receptor (ER) and progestin receptor (PR) concentrations in tumor biopsies are important predictive indicators of a clinical response to endocrine therapy of breast cancer. To assess interference of O.C.T. (optimum cutting temperature) embedding compound in assays of ER and PR by radioligand binding, we deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pasic R,Djulbegovic B,Wittliff JL

    更新日期:1989-12-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00

  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • Development of a multichannel electrochemical centrifugal analyzer.

    abstract::A new instrument has been developed that is similar in design and concept to the GeMSAEC centrifugal analyzer (Oak Ridge National Laboratory) except that electrochemical detection is used rather than optical detection. The present version has eight channels, each with its own detector. Problems of speed control and sa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cho HK,Lee YH,Couch RA,Jagadeesh JM,Olson CL

    更新日期:1982-09-01 00:00:00

  • Carcinoembryonic antigen as a marker for colorectal cancer: is it clinically useful?

    abstract:BACKGROUND:Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers worldwide. Its main application is mostly in gastrointestinal cancers, especially in colorectal malignancy. Although in use for almost 30 years, the clinical value of CEA in colorectal cancer is still not clear. METHODS:The literatu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Duffy MJ

    更新日期:2001-04-01 00:00:00

  • Ultracentrifugation in swinging-bucket and fixed-angle rotors evaluated for isolation and determination of high-density lipoprotein subfractions HDL2 and HDL3.

    abstract::We evaluated the density-gradient ultracentrifugation method in a swinging-bucket rotor (Anal Biochem 111, 149-157, 1981) in a slightly modified version for isolation and determination of high-density lipoprotein (HDL) subfractions. We prestained the serum with Coomassie Brilliant Blue R, which did not change the hydr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,van Sommeren-Zondag DF,Stalenhoef AF,Stuyt PM,van't Laar A

    更新日期:1983-04-01 00:00:00

  • Determination of cyclosporine concentrations with monoclonal antibodies.

    abstract::We measured cyclosporine in whole blood from normal volunteers administered single oral doses of the drug and from two renal-transplant patients on immunosuppressive maintenance therapy, by liquid chromatography (I) and by radioimmunoassay with use of nonspecific polyclonal (II), specific monoclonal (III), and nonspec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schran HF,Rosano TG,Hassell AE,Pell MA

    更新日期:1987-12-01 00:00:00

  • Chemical and immunochemical measurement of total iron-binding capacity compared.

    abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Lewis SA,Iosefsohn M,Hicks JM

    更新日期:1978-10-01 00:00:00

  • Collection of blood on filter paper for measurement of glycated hemoglobin by affinity chromatography.

    abstract::We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Little RR,McKenzie EM,Wiedmeyer HM,England JD,Goldstein DE

    更新日期:1986-05-01 00:00:00

  • Transferability studies for the AACC reference method and the IFCC method for measurement of alkaline phosphatase activity.

    abstract::We present the results of measurements of alkaline phosphatase activity from interlaboratory transferability studies conducted by 12 laboratories in five countries. The variability, as demonstrated by within-day precision (CV less than or equal to 2.6%), between-day precision (CV less than or equal to 3.6%), and betwe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tietz NW,Rinker AD,Burtis C,Duncan P,Ervin K,Ewen L,Hørder M,Mathieu M,Petitclerc C,Grisley D

    更新日期:1984-05-01 00:00:00

  • Development of time-resolved immunofluorometric assay of vascular permeability factor.

    abstract::We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-ch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yeo KT,Sioussat TM,Faix JD,Senger DR,Yeo TK

    更新日期:1992-01-01 00:00:00

  • Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

    abstract::With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Voelter W,Bauer H

    更新日期:1975-12-01 00:00:00

  • Sensitivity and specificity of the hydrogen breath-analysis test for detecting malabsorption of physiological doses of lactose.

    abstract::We examined the changes in sensitivity and specificity that would occur with alterations in the sample-collection schedule and (or) cutoff criterion for the increase in hydrogen concentration in breath after administration of doses of lactose in the dietary range. In a breath-analysis test to classify individuals as l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosado JL,Solomons NW

    更新日期:1983-03-01 00:00:00

  • Interlaboratory comparison of results of erythrocyte protoporphyrin analysis.

    abstract::Each of 65 laboratories analyzed 10 whole-blood samples for erythrocyte protoporphyrin by one or more of several analytical procedures. These procedures were of two types: (a) extraction of protoporphyrin from the erythrocytes into ethyl acetate/acetic acid, re-extraction into hydrochloric acid, and fluorometric measu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jackson KW

    更新日期:1978-12-01 00:00:00

  • Improved interassay correlation of digoxin results in patients with and without renal failure by elimination of digoxin-like immunoreactive factors.

    abstract::Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skogen WF,Rea MR,Valdes R Jr

    更新日期:1987-06-01 00:00:00

  • P-selectin- and CD63-exposing platelet microparticles reflect platelet activation in peripheral arterial disease and myocardial infarction.

    abstract:BACKGROUND:Platelet-derived microparticles (PMPs) are generally considered a marker of platelet activation in cardiovascular disease. We studied the extent to which PMP subpopulations parallel platelet activation in vitro and in vivo. METHODS:Using flow cytometry, we analyzed PMP subpopulations from resting and activa...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.057414

    authors: van der Zee PM,Biró E,Ko Y,de Winter RJ,Hack CE,Sturk A,Nieuwland R

    更新日期:2006-04-01 00:00:00

  • Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

    abstract::Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore FM,Simpson D

    更新日期:1989-08-01 00:00:00

  • The National Glycohemoglobin Standardization Program: Over 20 Years of Improving Hemoglobin A1c Measurement.

    abstract:BACKGROUND:Measurement of hemoglobin A1c (HbA1c) in the blood is integral to and essential for the treatment of patients with diabetes mellitus. HbA1c reflects the mean blood glucose concentration over the preceding 8 to 12 weeks. Although the clinical value of HbA1c was initially limited by large differences in result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.296962

    authors: Little RR,Rohlfing C,Sacks DB

    更新日期:2019-07-01 00:00:00

  • Radioimmunoassay of osteocalcin with polyclonal and monoclonal antibodies.

    abstract::We have developed and thoroughly validated radioimmunoassays (RIAs) for osteocalcin in plasma and serum, demonstrating independence of volume and determining the recovery of added standard and within- and between-assay precision. Antibodies were raised in rabbits and mice by immunization with either osteocalcin adsorb...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Power MJ,Gosling JP,Fottrell PF

    更新日期:1989-07-01 00:00:00