Abstract:
BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glucose profiles (premeal, postmeal, and bedtime) and HbA(1c) were measured quarterly during the DCCT. We studied measurements from (a) intensively treated patients at study commencement, (b) intensively treated patients after stabilization of their glycemia (from 6 months onward), and (c) conventionally treated patients from 6 months onward. Only complete glucose profile and HbA(1c) pairings were considered (n = 589, 11 483, and 11 855, respectively). RESULTS:From 6 months into the trial, conventionally treated patients had consistently higher MPG concentrations than intensively treated patients at any given HbA(1c) value (mean difference, 1.6 mmol/L at 7% HbA(1c), increasing to 2.8 mmol/L at 11% HbA(1c)). Similarly, at the same HbA(1c), the MPG of intensively treated patients at baseline was higher than in the same individuals after 6 months of intensive treatment (1.2 mmol/L difference at 7% HbA(1c), increasing to 4.6 mmol/L at 11% HbA(1c)). CONCLUSIONS:The relationship between MPG and HbA(1c) is not constant but differs depending on the glycemic control of the population being studied. Having lower mean glucose at the same HbA(1c) may help explain why intensive DCCT treatment appeared intrinsically linked to both increased hypoglycemia and decreased microvascular complications compared with conventional treatment. These findings may also have implications for expressing HbA(1c) as mean blood glucose equivalent.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Kilpatrick ES,Rigby AS,Atkin SLdoi
10.1373/clinchem.2006.079756subject
Has Abstractpub_date
2007-05-01 00:00:00pages
897-901issue
5eissn
0009-9147issn
1530-8561pii
clinchem.2006.079756journal_volume
53pub_type
杂志文章,随机对照试验abstract::Market forces have dramatically influenced the environment in which healthcare is delivered, but these changes do not need to be interpreted negatively by community laboratorians. Only total vertical integration of laboratory medicine can control episode-of-care cost. Opportunities also exist for horizontal integratio...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1996-05-01 00:00:00
abstract::We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared b...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-08-01 00:00:00
abstract:BACKGROUND:Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.216515
更新日期:2014-04-01 00:00:00
abstract::We report the kinetics of the reactions of unconjugated bilirubin and conjugated bilirubin with p-diazobenzene sulfonic acid in aqueous media. Our studies confirm that each reaction proceeds in two steps and that the second step is catalyzed by sulfanilic acid. In the presence of an excess of p-diazobenzenesulfonic ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-10-01 00:00:00
abstract::The topic of quality control often evokes prolific discussion among those whose business is its administration. Reliable methods for identifying mistakes must be developed in both the manufacture and use of test devices. Unit test devices are uncomplicated to run and provide quick results in a world where speed and si...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1997-05-01 00:00:00
abstract:BACKGROUND:We evaluated assays to measure both total tissue plasminogen activator (tPA) and the three principle forms of tPA in plasma: active tPA, tPA complexed with plasminogen activator inhibitor type 1 (PAI-1), and tPA complexed with C1-inhibitor. METHODS:Active tPA was measured by use of an indirect amidolytic as...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-01-01 00:00:00
abstract::Creatine kinase (CK; EC 2.7.3.2) has been used as an indicator of myocardial cellular damage. In this study we used a Krebs-Henseleit (KH) solution to reperfuse isolated rat hearts after 24 h of cold preservation and collected the KH reperfusate for assay of CK to assess cellular damage. We wanted to determine the sta...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-05-01 00:00:00
abstract:BACKGROUND:Human herpesvirus 6 (HHV-6) latently infects a majority of adults. In about 1% of the population HHV-6 exists in a chromosomally integrated form (ciHHV-6) that resides in every somatic and germ cell and can be transmitted through the germ line. Patients with ciHHV-6 have been misdiagnosed and unnecessarily t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.217240
更新日期:2014-05-01 00:00:00
abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-08-01 00:00:00
abstract::A modified gas-liquid chromatographic method for determining plasma concentrations of bupivacaine and lidocaine is described, with cyclizine as an internal standard. The extraction procedure requires no solvent evaporation, thus overcoming the problem of drug volatility. Concentrations as low as 0.1 mg/liter can be de...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-09-01 00:00:00
abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-07-01 00:00:00
abstract::This solid-phase competitive europium immunoassay of progesterone in plasma relies on antigen labeling. With this new approach, time-resolved fluoroimmunoassay can attain sensitivity and precision similar to that of conventional radioimmunoassay. The europium-labeling involves coupling diethylenetriaminepentaacetic ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-03-01 00:00:00
abstract::We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve fo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-10-01 00:00:00
abstract::We describe a new and specific method for measurement of lecithin palmitic acid in amniotic fluid. Dipalmitoyl lecithin, the major alveolar surfactant, has previously been estimated by measuring the lecithin-sphingomyelin ratio, total lecithin, total phospholipid phosphorus, and (or) total palmitic acid. Our method is...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract::A competitive solid-phase fluoroenzymeimmunoassay has been developed for rapidly measuring 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide (Pd-3G) directly in diluted specimens of pre-breakfast urine. The assay involves use of an antiserum to Pd-3G and enzyme-labeled antigen prepared by chemically linking g...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-02-01 00:00:00
abstract:BACKGROUND:It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.046995
更新日期:2005-08-01 00:00:00
abstract::3-Hydroxy-3-methylglutaric aciduria was detected in a newborn. The progress of the dietary therapy for the disorder was monitored by dual-column "high-performance" liquid chromatography with a computer-controlled photodiode array spectrophotometric detector. This procedure is a quick way to detect and monitor the prog...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-01-01 00:00:00
abstract::Correlation between coronary heart disease and lipoprotein size and composition is well documented. Within the low-density lipoprotein (LDL) family the small LDL particles are associated with increased risk of coronary heart disease. These particles also have increased apolipoprotein (apo) B content. The appearance of...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1995-01-01 00:00:00
abstract::We have explored the method of Rapoport et al. (J Clin Endocrinol Metab 1984;58:332-8) for the bioassay of thyroid-stimulating immunoglobulin (TSI) in cultured human thyroid cells, to optimize the assay and to evaluate its utility in clinical diagnosis and management of patients with autoimmune thyroid disease. Here w...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-02-01 00:00:00
abstract::We describe a rapid, sensitive, and specific "high performance" liquid chromatographic analysis for disopyramide and its mono-N-dealkylated metabolite in serum, urine, and saliva. We used a mu-Bondapak CN column and an acetate buffer mobile phase containing methanol. Retention times for the two compounds and the inter...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-03-01 00:00:00
abstract::Endotoxin, the lipopolysaccharide cell wall constituent of Gram-negative bacteria, produces symptoms of the Gram-negative sepsis syndrome. By measuring endotoxin in blood from septic patients it may be possible to select a subpopulation of patients in which mortality can be prevented by treatment with anti-endotoxin a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-08-01 00:00:00
abstract:BACKGROUND:Increased concentrations of cell-free DNA have been found in several disorders and have been interpreted as evidence of increased rates of cell death or turnover. Evidence from in vitro and animal experiments suggests that DNA may play a role in the pathogenesis of rheumatoid arthritis (RA). METHODS:We meas...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.084509
更新日期:2007-09-01 00:00:00
abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-01-01 00:00:00
abstract::Recent evidence indicates that high-density lipoprotein triglyceride (HDL-Tg) may be a predictor of coronary artery disease. We examined three methods for HDL-Tg measurement, comparing results obtained by measurement of Tg in the supernate after heparin-manganese chloride (heparin-Mn) precipitation of EDTA-treated pla...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-10-01 00:00:00
abstract:BACKGROUND:Next generation sequencing (NGS)-based assays continue to redefine the field of genetic testing. Owing to the complexity of the data, bioinformatics has become a necessary component in any laboratory implementing a clinical NGS test. CONTENT:The computational components of an NGS-based work flow can be conc...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2014.224360
更新日期:2015-01-01 00:00:00
abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-10-01 00:00:00
abstract:BACKGROUND:Analysis of fetal DNA in maternal plasma has recently been introduced as a new method for noninvasive prenatal diagnosis, particularly for the analysis of fetal genetic traits, which are absent from the maternal genome, e.g., RHD or Y-chromosome-specific sequences. To date, the analysis of other fetal geneti...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.029835
更新日期:2004-06-01 00:00:00
abstract:BACKGROUND:First introduced into clinical microbiology laboratories in Europe, MALDI-TOF MS is being rapidly embraced by laboratories around the globe. Although it has multiple applications, its widespread adoption in clinical microbiology relates to its use as an inexpensive, easy, fast, and accurate method for identi...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2014.221770
更新日期:2015-01-01 00:00:00
abstract::We compared cotinine, carboxyhemoglobin, and thiocyanate concentrations in blood sampled from 187 cigarette smokers and 181 non-smokers. All three differed significantly between smokers and non-smokers. Cotinine performed best as a test for assessing smoking status, with a sensitivity of 98% as compared with 94% for c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-08-01 00:00:00