Clinical significance of lipoprotein size and risk for coronary atherosclerosis.

Abstract:

:Correlation between coronary heart disease and lipoprotein size and composition is well documented. Within the low-density lipoprotein (LDL) family the small LDL particles are associated with increased risk of coronary heart disease. These particles also have increased apolipoprotein (apo) B content. The appearance of these small LDL particles is the manifestation of complex alteration of plasma lipoprotein metabolism. The LDL size is influenced by genetic, endocrine, and environmental factors. Within the high-density lipoprotein (HDL) family the decrease of larger HDL2 particles is associated with coronary heart disease. HDLs can also be separated according to their apoprotein composition into particles containing lipoprotein (Lp)A-I only and particles containing LpA-I and LpA-II. Most studies have shown that the concentration of LpA-I-only particles decreases in coronary heart disease. HDLs are remodeled in the circulation and this remodeling continues in vitro after the blood is taken. Therefore adequate preservation of blood samples is necessary.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Roheim PS,Asztalos BF

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

147-52

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

41

pub_type

杂志文章,评审
  • Multicenter evaluation of Iso-ALP test kit for measurement of bone alkaline phosphatase activity in serum and plasma.

    abstract::A test kit (Iso-ALP, Boehringer Mannheim) for measuring human bone alkaline phosphatase activity in serum or plasma was evaluated in five laboratories in three countries. The assay is based on the principle described by Rosalki and Foo (Clin Chem 1984;30:1182-6) and uses wheat germ lectin to precipitate bone alkaline ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY,Burlina A,Prellwitz W,Stieber P,Neumeier D,Klein G,Poppe WA,Bodenmüller H

    更新日期:1993-04-01 00:00:00

  • Analytical approaches of European Union laboratories to drugs of abuse analysis.

    abstract::We report a survey on urine drug testing within a total of 269 laboratories of the European Union. Clinical laboratories predominated over forensic laboratories (59.5% vs 28.5%). Screening without identification/quantification was the common approach used by clinical laboratories, whereas screening with identification...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Badia R,de la Torre R,Corcione S,Segura J

    更新日期:1998-04-01 00:00:00

  • A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.

    abstract::We evaluated a new, simple, enzymatic kinetic method from Wako Chemicals GmbH in comparison with a kinetic Jaffé method by using isotope dilution-mass spectrometry (ID-MS) as a reference method. An ID-MS-calibrated serum standard was used. Both the enzymatic and the Jaffé method correlated well with ID-MS, except for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindbäck B,Bergman A

    更新日期:1989-05-01 00:00:00

  • Cross reactions in radioimmunoassay: a mathematical model for correcting assay results, as exemplified by eliminating the interference of intact thyrotropin in an assay of its beta subunit.

    abstract::To correct the results of a radioimmunoassay for beta-thyrotropin (TSH) subunit by eliminating the proportion ascribable to intact TSH, we have devised a method that experimentally reproduces the conditions under which the interference develops. Beta-TSH subunit was assayed in several preparations containing known con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dotti C,Ceda GP,Denti L,Cavalieri S,Borasi G,Valenti G

    更新日期:1987-05-01 00:00:00

  • Automated enzymic measurement of total cholesterol in serum.

    abstract::We describe a completely automated enzymic system for measuring total cholesterol in serum. All reagents are contained in an analytical test pack and the test is performed on Du Pont's Automatic Clinical Analyzer (aca), which mixes the sample (20 microliter) and reagents and performs the necessary absorbance measureme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rautela GS,Liedtke RJ

    更新日期:1978-01-01 00:00:00

  • Overtraining in neural networks that interpret clinical data.

    abstract::Backpropagation neural networks are a computer-based pattern-recognition method that has been applied to the interpretation of clinical data. Unlike rule-based pattern recognition, backpropagation networks learn by being repetitively trained with examples of the patterns to be differentiated. We describe and analyze t...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Astion ML,Wener MH,Thomas RG,Hunder GG,Bloch DA

    更新日期:1993-09-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • Kinetic determination of serum sorbitol dehydrogenase activity with a centrifugal analyzer.

    abstract::We describe a mechanized method for centrifugal analyzer determination of sorbitol dehydrogenase in serum, based on conversion of D-fructose to sorbitol with simultaneous oxidation of NADH, in triethanolamine buffer at pH 7.4 and 30 degrees C. The standard curve for this assay is linear to 200 U of activity per liter ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dooley JF,Turnquist LJ,Racich L

    更新日期:1979-12-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.

    abstract::We present an improved Na+-selective liquid membrane electrode for measurement of Na+ concentrations in both undiluted serum and urine. The values for urinary Na+ obtained with the ion-selective electrode agree well with those obtained with the flame photometer. The correlation gives a standard residual deviation of +...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anker P,Jenny HB,Wuthier U,Asper R,Ammann D,Simon W

    更新日期:1983-08-01 00:00:00

  • An approach to molecular analysis of T-cell clones by two-dimensional gel electrophoresis: is there interclonal and intraclonal heterogeneity?

    abstract::To understand the regulation of immunity one must understand the processes and the consequences of the activation of the lymphoid cell, its clonal proliferation, and the ultimate differentiation of the progeny into the effector elements that constitute the immune system. By use of polyclonal mitogens, individual T-cel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kettman J,Lefkovits I

    更新日期:1984-12-01 00:00:00

  • A sensitive liquid-chromatographic method for determination of 3'-azido-3'-deoxythymidine (AZT) in plasma and urine.

    abstract::We describe a liquid-chromatographic assay for AZT in human plasma and urine. This assay involves the use of two internal standards, allowing reference of AZT peaks to the appropriate internal standard, the choice depending on the range of concentrations encountered. This method is isocratic, specific, sensitive enoug...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hedaya MA,Sawchuk RJ

    更新日期:1988-08-01 00:00:00

  • A case of sulfhemoglobinemia and emergency measurement of sulfhemoglobin with an OSM3 CO-oximeter.

    abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu C,Kenny MA

    更新日期:1997-01-01 00:00:00

  • Prognostic value of emerging neurohormones in chronic heart failure during optimization of heart failure-specific therapy.

    abstract:BACKGROUND:Serial measurements of neurohormones have been shown to improve prognostication in the setting of acute heart failure (HF) or chronic HF without therapeutic intervention. We investigated the prognostic role of serial measurements of emerging neurohormones and BNP in a cohort of chronic HF patients undergoing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.125856

    authors: Neuhold S,Huelsmann M,Strunk G,Struck J,Adlbrecht C,Gouya G,Elhenicky M,Pacher R

    更新日期:2010-01-01 00:00:00

  • Development of a proton nuclear magnetic resonance spectroscopic method for determining plasma lipoprotein concentrations and subspecies distributions from a single, rapid measurement.

    abstract::We are developing a method for quantifying plasma lipoproteins by proton nuclear magnetic resonance (NMR) spectroscopy that offers advantages over existing clinical methods. We showed that the major lipoproteins have distinct NMR properties sufficient to permit their concentrations to be extracted from a computer line...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Otvos JD,Jeyarajah EJ,Bennett DW,Krauss RM

    更新日期:1992-09-01 00:00:00

  • Inhibition of stimulated interleukin-2 production in whole blood: a practical measure of cyclosporine effect.

    abstract:BACKGROUND:Prediction of cyclosporine (CSA) efficacy and toxicity in individual patients is difficult. There is no practical, biologically relevant, pharmacodynamic measure of CSA effect. A major effect of CSA is to decrease interleukin-2 (IL-2) production; however, measurement of this effect in isolated lymphocytes as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stein CM,Murray JJ,Wood AJ

    更新日期:1999-09-01 00:00:00

  • Evaluation of the BMC glucose oxidase/peroxidase-4-aminophenazone-phenol procedure for glucose as adapted to the Technicon SMAC.

    abstract::We evaluated the analytical performance of Trinder's glucose oxidase (EC 1.1.3.4)/peroxidase (EC 1.11.1.7) 4-aminophenazone-phenol method for the quantification of serum glucose as adapted to the Technicon SMAC. Our results correlated well with those by the routine SMAC glucose oxidase/peroxidase 3-methyl-2-benzothiaz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Purcell GV,Behenna DB,Walsh PR

    更新日期:1979-10-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Rapid detection of leukemia cells by use of a complement-mediated cytolytic reaction and an imaging sensor system.

    abstract::We describe a system for detection of leukemia cells involving complement-mediated cytotoxic reaction and an image processing system, consisting of a charge-coupled-device image sensor, an image memory board, a personal computer, and a phase-contrast microscope. Then added to a cell suspension, monoclonal antibody spe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki M,Tamiya E,Kataoka T,Tokunaga T,Karube I

    更新日期:1987-04-01 00:00:00

  • Development of a kinetic assay for band 5b tartrate-resistant acid phosphatase activity in serum.

    abstract:BACKGROUND:Band 5 tartrate-resistant acid phosphatase (TrACP; EC 3. 1.3.2) consists of two isoenzymes, bands 5a and 5b, of which band 5b TrACP is considered to be derived from bone. However, no kinetic method for the specific measurement of band 5b TrACP in serum is available. Our aim was to develop a kinetic assay met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakanishi M,Yoh K,Miura T,Ohasi T,Rai SK,Uchida K

    更新日期:2000-04-01 00:00:00

  • Improved HPLC method for carbohydrate-deficient transferrin in serum.

    abstract:BACKGROUND:There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms. METHODS:Transferrin was iron-saturated by mixing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.023341

    authors: Helander A,Husa A,Jeppsson JO

    更新日期:2003-11-01 00:00:00

  • Precipitation methods for high-density lipoprotein cholesterol measurement compared, and final evaluation under routine operating conditions of a method with a low sample-to-reagent ratio.

    abstract::We evaluated six precipitation methods for high-density lipoprotein cholesterol (HDL-chol) determination: the heparin/Mn2+ precipitation reagent method (Hep), two variants of the phosphotungstic acid/Mg2+ method (Tung-L and Tung-B), the dextran sulfate 50,000/Mg2+ method (Dex), the PEG 6000 method (PEG), and the PEG 6...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,Hessels M,Toenhake-Dijkstra H,Baadenhuijsen H

    更新日期:1997-04-01 00:00:00

  • Enzyme-linked immunosorbent choriomammotropin assay.

    abstract::We have devloped an enzyme-linked immunosorbent assay for determining choriomammotropin (human placental lactogen) in serum. Unlabeled hormone competes with choriomammotropin-beta-galactosidase conjugate for antibody bound to polystyrene tubes. The entire assay can be performed in 2.5 h with good precision. The coeffi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dittmar D,Monji N,Cid A,Malkus H,Castro A

    更新日期:1979-02-01 00:00:00

  • Micro-quantity tissue digestion for metal measurements by use of a microwave acid-digestion bomb.

    abstract::We describe a simple and convenient method for processing small amounts of tissue samples for trace-metal measurements by atomic absorption spectrometry, by use of a modified Parr microwave digestion bomb. Digestion proceeds rapidly (less than or equal to 90 s) in a sealed Teflon-lined vessel that eliminates contamina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nicholson JR,Savory MG,Savory J,Wills MR

    更新日期:1989-03-01 00:00:00

  • Toxicity of free p-cresol: a prospective and cross-sectional analysis.

    abstract:BACKGROUND:Uremic syndrome is the consequence of the retention of solutes usually cleared by the healthy kidneys. p-Cresol can be considered a prototypic protein-bound uremic toxin. It is conceivable, analogous with drugs, that the non-protein-bound fraction of p-cresol exerts toxicity. This aspect had never been evalu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.3.470

    authors: De Smet R,Van Kaer J,Van Vlem B,De Cubber A,Brunet P,Lameire N,Vanholder R

    更新日期:2003-03-01 00:00:00

  • Use of neural networks to diagnose acute myocardial infarction. II. A clinical application.

    abstract::We investigated the ability of neural networks to diagnose acute myocardial infarction (AMI) from laboratory data only. Several networks were trained with different combinations of data obtained at admission and within the first 12 h and 24 h after admission. The data used included the electrocardiogram (ECG) and the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pedersen SM,Jørgensen JS,Pedersen JB

    更新日期:1996-04-01 00:00:00

  • Cross reactivity of digitoxin and spironolactone in two radioimmunoassays for serum digoxin.

    abstract::We measured the cross reactivity of two medications--digitoxin and spironolactone--in two digoxin radioimmunoassay (liquid and solid-phase) kit procedures. Both tests showed similar average percentages of cross reactivity with digitoxin (7.2 and 8.9% for intravenous, and 11.9 and 10.9% for oral administration), but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Müller H,Bräuer H,Resch B

    更新日期:1978-04-01 00:00:00

  • Comparison of 11 human insulin assays: implications for clinical investigation and research.

    abstract:BACKGROUND:The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. METHODS:In 2004, we compared 11 commercially available insulin assays by analyz...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2006.077784

    authors: Manley SE,Stratton IM,Clark PM,Luzio SD

    更新日期:2007-05-01 00:00:00

  • C-reactive protein stimulates myeloperoxidase release from polymorphonuclear cells and monocytes: implications for acute coronary syndromes.

    abstract:BACKGROUND:C-reactive protein (CRP), the prototypic marker of inflammation, is present in atherosclerotic plaques and appears to promote atherogenesis. Also, CRP has been localized to monocytes and tissue macrophages, which are present in the necrotic core of lesions prone to plaque rupture. Leukocyte-derived myelopero...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.109207

    authors: Singh U,Devaraj S,Jialal I

    更新日期:2009-02-01 00:00:00

  • Automated measurement of urinary iodine with use of ultraviolet irradiation.

    abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuda K,Namba H,Nomura T,Yokoyama N,Yamashita S,Izumi M,Nagataki S

    更新日期:1995-04-01 00:00:00