Analytical approaches of European Union laboratories to drugs of abuse analysis.

Abstract:

:We report a survey on urine drug testing within a total of 269 laboratories of the European Union. Clinical laboratories predominated over forensic laboratories (59.5% vs 28.5%). Screening without identification/quantification was the common approach used by clinical laboratories, whereas screening with identification/quantification was the approach used by almost all forensic laboratories. Screening was primarily performed by immunoassay in both types of laboratories. Gas chromatography coupled to mass spectrometry was the main analytical method used for specific identification/quantification of drugs, but other methods (including immunoassays) were also used. Cutoff values applied varied by laboratory type, country, and method used. A high percentage of laboratories did not use or report cutoff values. Overall, countries of the European Union vary significantly in regards to drugs tested, analytical approach, and screening and identification cutoff values. It is recommended to clearly state the analytical method and the cutoff values used when reporting results for drugs of abuse testing.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Badia R,de la Torre R,Corcione S,Segura J

subject

Has Abstract

pub_date

1998-04-01 00:00:00

pages

790-9

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

44

pub_type

杂志文章
  • Evaluation of two digoxin radioimmunoassay procedures in which 125I-labeled digoxin is used.

    abstract::We present a comparative evaluation of two commercial kits, the "Quantitope" and "GammaCoat," for radioimmunoassay of digoxin in serum. These kits, in which iodine-125 is used as a label, proved to suitable for digoxin assay as determined by their reproducibility, sensitivity, precision, and a regression analysis. Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuczala ZJ,Ahluwalia GS

    更新日期:1976-02-01 00:00:00

  • Fetuin-A is an independent predictor of death after ST-elevation myocardial infarction.

    abstract:BACKGROUND:Fetuin-A inhibits inflammation and has a protective effect against myocardial ischemia. Its deficiency has been found to be associated with cardiovascular death in patients with end-stage renal failure disease. We investigated the association between plasma fetuin-A and clinical outcome after ST-elevation ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.084947

    authors: Lim P,Collet JP,Moutereau S,Guigui N,Mitchell-Heggs L,Loric S,Bernard M,Benhamed S,Montalescot G,Randé JL,Guéret P

    更新日期:2007-10-01 00:00:00

  • International normalized ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurements.

    abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lassen JF,Brandslund I,Antonsen S

    更新日期:1995-03-01 00:00:00

  • Methylmalonic acid concentrations in serum of normal subjects: biological variability and effect of oral L-isoleucine loads before and after intramuscular administration of cobalamin.

    abstract::The clinical value of measuring concentrations of methylmalonic acid in serum (S-MMA) as an aid in the diagnosis of cobalamin deficiency has recently aroused interest. In 58 healthy subjects, ages 40-68 years, we found a 0.95 reference interval of 0.05-0.37 mumol/L (mean 0.21, SD 0.094). In 33 of the subjects, who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rasmussen K,Møller J,Ostergaard K,Kristensen MO,Jensen J

    更新日期:1990-07-01 00:00:00

  • Direct determination of sulfate conjugates of 17-oxosteroids in urine by liquid chromatography.

    abstract::We describe a new liquid-chromatographic method with fluorescence detection for direct simultaneous determination of four urinary sulfate conjugates of 17-oxosteroids (17OS), without use of solvolysis or enzymatic hydrolysis. The 17OS sulfates in urine samples are extracted with benzene as ion pairs in the presence of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nishikaze O,Iwata J

    更新日期:1986-05-01 00:00:00

  • Two automated methods for plasma antithrombin III compared, and the clinical significance of the results.

    abstract::Antithrombin III (AT III) activity was determined with two different new chromogenic substances--Chromozym-TH (Tos-Gly-Arg-p-nitroanilide; Boehringer Mannheim) and alpha-N-carbobenzyl-oxy-L-lysine-thiobenzyl ester (Du Pont)--with both a discrete (aca) and a centrifugal analyzer (COBAS BIO). The correlation between the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Prellwitz W,Schmitt KF,Machner M,Schuster CJ,Weilemann L

    更新日期:1982-11-01 00:00:00

  • Detection of heterozygotes for phenylketonuria by constant intravenous infusion of L-phenylalanine.

    abstract::We measured the rate of elimination of phenylalanine by constant intravenous infusion of L-phenylalanine in 14 parents of children with phenylketonuria and in 21 subjects with a negative family history for this disease. When reciprocals of the observed elimination rates were plotted against the reciprocals of the incr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jagenburg R,Rödjer S

    更新日期:1977-09-01 00:00:00

  • Validation of RNA arbitrarily primed PCR probes hybridized to glass cDNA microarrays: application to the analysis of limited samples.

    abstract:BACKGROUND:The applicability of microarray-based transcriptome massive analysis is often limited by the need for large amounts of high-quality RNA. RNA arbitrarily primed PCR (RAP-PCR) is an unbiased fingerprinting PCR technique that reduces both the amount of initial material needed and the complexity of the transcrip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.036236

    authors: Grau M,Solé X,Obrador A,Tarafa G,Vendrell E,Valls J,Moreno V,Peinado MA,Capellá G

    更新日期:2005-01-01 00:00:00

  • Findings of an external quality assessment scheme for determining aluminum in dialysis fluids and water.

    abstract::The analytical performance of laboratories participating in the dialysis fluids and water aluminum program of the Guildford External Quality Assessment Scheme over the period 1986-1993 has been reviewed. For aluminum concentrations > 3.33 mumol/L in dialysis fluids, the between-laboratory CV has fallen from approximat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taylor A,Briggs RJ,Cevik C

    更新日期:1994-08-01 00:00:00

  • Protease inhibitor-associated dyslipidemia in HIV-infected patients is strongly influenced by the APOA5-1131T->C gene variation.

    abstract:BACKGROUND:Hyperlipidemia associated with the protease inhibitor (PI) component of highly active antiretrovial treatment can lead to accelerated atherosclerosis. The apolipoprotein A-V (APOA5) gene, which affects VLDL production and lipolysis, may play a role in PI-induced hyperlipidemia, particularly in individuals wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.069583

    authors: Guardiola M,Ferré R,Salazar J,Alonso-Villaverde C,Coll B,Parra S,Masana L,Ribalta J

    更新日期:2006-10-01 00:00:00

  • Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.

    abstract::We present an improved Na+-selective liquid membrane electrode for measurement of Na+ concentrations in both undiluted serum and urine. The values for urinary Na+ obtained with the ion-selective electrode agree well with those obtained with the flame photometer. The correlation gives a standard residual deviation of +...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anker P,Jenny HB,Wuthier U,Asper R,Ammann D,Simon W

    更新日期:1983-08-01 00:00:00

  • Mass concentration and activity concentration of creatine kinase isoenzyme MB compared in serum after acute myocardial infarction.

    abstract::We compared three current methods (immunoinhibition, "Isomune-CK" immunoprecipitation, and the Tandem-E CKMB II immunoenzymometric assay) for determination of creatine kinase (CK; EC 2.7.3.2) isoenzyme MB in serum. Although results inter-correlated well, the immunoinhibition assay gave higher activity values. Atypical...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,De Mol AM,De Buyzere ML,De Scheerder IK,Wieme RJ

    更新日期:1990-01-01 00:00:00

  • Multianalyte microspot immunoassay--microanalytical "compact disk" of the future.

    abstract::Throughout the 1970s, controversy centered both on immunoassay "sensitivity" per se and on the relative sensitivities of labeled antibody (Ab) and labeled analyte methods. Our theoretical studies revealed that RIA sensitivities could be surpassed only by the use of very high-specificity nonisotopic labels in "noncompe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ekins RP,Chu FW

    更新日期:1991-11-01 00:00:00

  • The journey to regulation of protein-based multiplex quantitative assays.

    abstract:BACKGROUND:Clinical proteomics presents great promise in biology and medicine because of its potential for improving our understanding of diseases at the molecular level and for detecting disease-related biomarkers for diagnosis, prognosis, and prediction of therapeutic responses. To realize its full potential to impro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.156034

    authors: Boja ES,Jortani SA,Ritchie J,Hoofnagle AN,Težak Ž,Mansfield E,Keller P,Rivers RC,Rahbar A,Anderson NL,Srinivas P,Rodriguez H

    更新日期:2011-04-01 00:00:00

  • Plasma fibrinogen, cholinesterase activity, and anemia: utility of fibrinogen in multiphasic screening and in assessing the activity of diseases.

    abstract::I present the general pattern relationship between (a) plasma fibrinogen and cholinesterase activity and (b) plasma fibrinogen and hemoglobin, in 250 and 310 hospitalized adults, respectively. Although responses of cholinesterase were often unrelated to fibrinogen, when its activity in plasma was depressed, above-norm...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rice EW

    更新日期:1977-01-01 00:00:00

  • Simplified micro-scale procedure for preparing samples for theophylline determination by liquid chromatography.

    abstract::We describe an improved procedure for the preparation of plasma or serum for determination of theophylline by reverse phase high-performance liquid chromatography. Quantitative results are available in less than 30 min from receipt of sample. The chromatogram is complete in 8 to 16 min, which includes the use of an in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nelson JW,Cordry AL,Aron CG,Bartell RA

    更新日期:1977-01-01 00:00:00

  • Estimation of very-low-density lipoprotein cholesterol from data on triglyceride concentration in plasma.

    abstract::We examined the relationship in a large-living population between the concentration of triglycerides in plasma from fasting persons and the concentration of very-low-density lipoprotein cholesterol (VLDL-C) as determined after preparative ultracentrifugation. Data from individuals in the Framingham Heart Study who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson PW,Abbott RD,Garrison RJ,Castelli WP

    更新日期:1981-12-01 00:00:00

  • Arylesterase in serum: elaboration and clinical application of a fixed-incubation method.

    abstract::A sensitive, specific, and simple method for determining serum or urine arylesterase (EC 3.1.1.2) is described. The enzyme acts on phenyl acetate to release phenol, which produces a stable indophenol dye with 4-aminoantipyrine and potassium ferricyanide. Arylesterase, a thiol enzyme, is reactivated by 2-mercaptoethano...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lorentz K,Flatter B,Augustin E

    更新日期:1979-10-01 00:00:00

  • Immunoassay of low concentrations of albumin in urine by latex particle counting.

    abstract::We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 5...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cambiaso CL,Collet-Cassart D,Lievens M

    更新日期:1988-02-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Sensitivity and specificity of the hydrogen breath-analysis test for detecting malabsorption of physiological doses of lactose.

    abstract::We examined the changes in sensitivity and specificity that would occur with alterations in the sample-collection schedule and (or) cutoff criterion for the increase in hydrogen concentration in breath after administration of doses of lactose in the dietary range. In a breath-analysis test to classify individuals as l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosado JL,Solomons NW

    更新日期:1983-03-01 00:00:00

  • Effects of storage time and temperature on urinary enzymes.

    abstract::We measured three renal tubular brush-border enzymes (lactate dehydrogenase, LDH, EC 1.1.1.27; gamma-glutamyltransferase, GGT, EC 2.3.2.2; and alkaline phosphatase, AP, EC 3.1.3.1) in morning urine samples from 48 healthy subjects to check whether different storage times and temperatures could modify enzyme concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matteucci E,Gregori G,Pellegrini L,Navalesi R,Giampietro O

    更新日期:1991-08-01 00:00:00

  • Erythrocyte folate analysis: saponin added during lysis of whole blood can increase apparent folate concentrations, depending on hemolysate pH.

    abstract:BACKGROUND:The analysis of red cell folate (RCF) depends on complete hemolysis of erythrocytes, and it is assumed that complete hemolysis is achieved by 10-fold dilution of whole blood with hypotonic solutions of 10 g/L ascorbic acid/ascorbate. This report challenges this assumption. METHODS:The conventional method of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wright AJ,Finglas PM,Southon S

    更新日期:2000-12-01 00:00:00

  • Immunopeptidometric assay for enzymatically active prostate-specific antigen.

    abstract:BACKGROUND:Determinations of certain forms of prostate-specific antigen (PSA) have been shown to increase the specificity for prostate cancer (PCa). One such variant, proteolytically active PSA, is a potentially useful tumor marker, but it is not specifically recognized by antibodies. Using phage display libraries, we ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026146

    authors: Wu P,Zhu L,Stenman UH,Leinonen J

    更新日期:2004-01-01 00:00:00

  • Central role of zinc protoporphyrin in staging iron deficiency.

    abstract::In iron deficiency, zinc protoporphyrin (ZPP) is produced instead of heme, and the ZPP concentration in erythrocytes is increased (normal < or = 40 mumol/mol heme). We investigated the relevance of ZPP for staging iron deficiency. ZPP was determined by hematofluorometry in samples from 103 patients. Nineteen patients ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hastka J,Lasserre JJ,Schwarzbeck A,Hehlmann R

    更新日期:1994-05-01 00:00:00

  • Use of magnetic circular dichroism spectroscopy for biologic monitoring of occupational exposures to toxicants.

    abstract::Zinc protoporphyrin is the predominent fluorescent porphyrin accumulating in erythrocytes as a result of chronic lead absorption or iron-deficiency anemia. Although diagnostic concentrations or thresholds for it in erythrocytes have been inferred, normal adult averages have not been established. We quantitatively asse...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zygowicz ER,Hollebone BR,Perkins HM

    更新日期:1980-09-01 00:00:00

  • Reappraisal of the uroporphyrinogen I synthase assay, and a proposed modified method.

    abstract::Problems encountered in the uroporphyrinogen I synthase assay were found to be due to the Triton reagent, slit-width and excitation wavelength settings of the spectrophotofluorometer, and leg-phase in the enzyme reaction. Of Triton X-100 from four suppliers, only three were found suitable. Differences in enzyme activi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chamberlain BR,Buttery JE

    更新日期:1980-08-01 00:00:00

  • Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

    abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127241

    authors: Kavsak PA,Wang X,Ko DT,MacRae AR,Jaffe AS

    更新日期:2009-10-01 00:00:00

  • Immunological measurement of transferrin compared with chemical measurement of total iron-binding capacity.

    abstract::Because of uncertainty as to the molecular weight of transferrin, a previous comparison [Von der Heul et al., Clin. Chim. Acta 38, 347 (1972)] between transferrin content of serum and total iron-binding capacity cannot be definitive. We found a conversion factor for expressing the maximum amount of iron bound by 1 mg ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsung SH,Rosenthal WA,Milewski KA

    更新日期:1975-07-01 00:00:00

  • Analytical performance of EMIT cyclosporine assay evaluated.

    abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Desai M

    更新日期:1991-12-01 00:00:00