Abstract:
:We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 50 mg/L and has a detection limit of 0.4 mg/L. Analytical recoveries at three concentrations ranged between 96% and 102%. Within-run precision ranged from 1.6% to 9.5%. The method was compared with a commercial nephelometric immunoassay system and a correlation coefficient of 0.996 was found for 216 urine samples. No antigen excess affects the shape of the curve in our system, whereas in nephelometry a 3 g/L solution of albumin starts to decrease the dose-response curve.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Cambiaso CL,Collet-Cassart D,Lievens Msubject
Has Abstractpub_date
1988-02-01 00:00:00pages
416-8issue
2eissn
0009-9147issn
1530-8561journal_volume
34pub_type
杂志文章abstract:BACKGROUND:Calcitonin (CT) is a sensitive marker for evaluation of medullary thyroid cancer (MTC). However, CT measurement can vary with assay- and nonassay-dependent factors, and procalcitonin (PCT) measurement has been proposed for evaluating questionable increases in CT. METHODS:We tested 2 fully automated CT assay...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.151688
更新日期:2011-03-01 00:00:00
abstract::We compared different sample-handling techniques for measurement of Na+ and K+ with ion-selective electrodes (ISE). Imprecision was less for venous blood (with a minimum of heparin) than for plasma, serum, or capillary blood. The results for K+ were higher for serum than for whole blood, and higher for whole blood tha...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-03-01 00:00:00
abstract::Highly purified human lactate dehydrogenase 1 has been used in an interlaboratory evaluation and improvement progran in clinical chemistry in New York State since 1971. Although there are difficulties in determining and assigning the most nearly accurate values for test samples in the absence of a reference method and...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-06-01 00:00:00
abstract:BACKGROUND:Because reference values for vitamin B(12) concentrations and vitamin B(12)-binding capacities for pregnant women have not been established, the reference values for nonpregnant women are often applied to assess vitamin B(12) status. The aim of the present study was to describe ranges of biochemical indices ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-06-01 00:00:00
abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-04-01 00:00:00
abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:2002-03-01 00:00:00
abstract:BACKGROUND:We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non-ST-segment elevation myocardial infarction (STEMI). METHODS:hs-cTnT was measured serially in consecutive ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.171827
更新日期:2012-01-01 00:00:00
abstract::We describe a radioassay for cobalamin (vitamin B12) in human serum or plasma that requires no boiling or other pretreatment of the sample. Normal chicken serum covalently coupled to magnetizable particles is used as the binding agent. The assay is performed at pH 12.9, at which pH all cobalamin in human serum is rele...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-02-01 00:00:00
abstract::We describe a direct radioimmunoassay for serotonin (5-hydroxytryptamine) in cerebrospinal fluid, platelet-poor plasma, and serum. We raised antisera in rabbits against serotonin diazotized to a conjugate of bovine albumin and D,L-p-aminophenylalanine. Polyethylene glycol, alone or in combination with anti-rabbit immu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract:BACKGROUND:Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary refere...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.256768
更新日期:2016-07-01 00:00:00
abstract:BACKGROUND:Multiplexed amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, asymmetric PCR, or allele-specific PCR; however, correct differentiation of homozygous mutant and wild-type samples by melting temperature (T(m)) analysis requires high-resolution melting ana...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.097121
更新日期:2008-01-01 00:00:00
abstract:BACKGROUND:We evaluated the analytical performance of 4 cystatin C assays (Siemens N Latex on BNII, Roche Tina-quant on Cobas c501, Genzyme on Cobas c501, and Tosoh ST AIA-PACK on Tosoh AIA-600II) according to guidelines published by the Clinical and Laboratory Standards Institute. METHODS:We evaluated total imprecisi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.141531
更新日期:2010-08-01 00:00:00
abstract:BACKGROUND:Massively parallel sequencing has recently been used in noninvasive prenatal diagnosis. The current costs of this technology are still relatively expensive, however, and sample throughput is still relatively low when it is used as a molecular diagnostic tool. Rather than nonselectively sequencing the genome,...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.154336
更新日期:2011-01-01 00:00:00
abstract:BACKGROUND:Studies of the effects of tobacco smoke often rely on reported exposure to cigarette smoke, a measure that is subject to bias. We describe here the relationship between parental smoking exposure as assessed by urinary cotinine excretion and lung function in children with asthma. METHODS:We studied 90 childr...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-04-01 00:00:00
abstract::We describe a new and specific method for measurement of lecithin palmitic acid in amniotic fluid. Dipalmitoyl lecithin, the major alveolar surfactant, has previously been estimated by measuring the lecithin-sphingomyelin ratio, total lecithin, total phospholipid phosphorus, and (or) total palmitic acid. Our method is...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract::We tested 231 urine samples by six immunoassay methods--EMIT d.a.u., EMIT II, Roche Abuscreen Online, Abbott TDx, Diagnostic Products Corp. (DPC) double-antibody radioimmunoassay (RIA), and Biosite Triage--and by negative chemical ionization gas chromatography/mass spectrometry to determine how the immunoassays perfor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-03-01 00:00:00
abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:BACKGROUND:Remnant lipoprotein-cholesterol (RLP-C) concentrations in sera of healthy individuals are very low (0.080-0.437 mmol/L), making conventional cholesterol methods poorly suited to this purpose. We have developed a highly sensitive cholesterol assay (CD method) and applied it to the RLP-C assay. METHODS:The CD...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-05-01 00:00:00
abstract::We present a case of advanced ovarian carcinoma associated with high concentrations of serum and urine amylase. Biochemical analysis to elucidate the nature and origin of the hyperamylasemia identified seven amylase isoenzymes, of which five appeared to be distinct from normal salivary and pancreatic amylase. We discu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-06-01 00:00:00
abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract::In routine analysis for immunoglobulin light chains in pediatric diagnostics, the age-related reference intervals for serum kappa (kappa) and lambda (lambda) light chains were evaluated in 1543 healthy subjects (newborns to age 16 years, including 168 premature infants). Light-chain analysis was performed by rate neph...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-04-01 00:00:00
abstract::The values of apolipoproteins (apo) A-I and B were determined in a population sample of hospital outpatients with a standardized method to verify if the cutpoints calculated in a cross-sectional study in the US are usable with other populations. We also tested the apolipoproteins' ability to discriminate between healt...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::In response to the pressures of cost reduction, we established and evaluated a carefully integrated program to deliver clinical laboratory services more promptly and efficiently to the intensive care units (ICUs). The new protocol reduced the steps and turnaround time from ordering tests by physicians to reporting res...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-03-01 00:00:00
abstract:BACKGROUND:False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation dif...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.091488
更新日期:2007-12-01 00:00:00
abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.047399
更新日期:2005-08-01 00:00:00
abstract:BACKGROUND:Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within- (CV(i)) an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-04-01 00:00:00
abstract::We studied the pattern of acute-phase proteins (orosomucoid, C-reactive protein, and haptoglobin) in hepatocellular deficiency due to chronic alcohol consumption, characterized by a decrease in serum transferrin concentration. We found that their patterns could vary independently of hepatocellular deficiency, but depe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract::This HPLC/immunoassay procedure measures digoxin in serum with no interference from digoxin metabolites or digoxin-like factors. We used solid-phase (C18 and Diol) extraction, a C18 column with a tetrahydrofuran/water mobile phase, and final quantification by fluorescence polarization immunoassay. Deslanoside and gito...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-12-01 00:00:00
abstract::In this immunoenzymatic assay for human lutropin (hLH) we used bi-specific antibodies (BiAbs) obtained from the fusion of two hybridomas producing antibodies to beta-D-galactosidase and hLh. The BiAb complexed with the enzyme beta-D-galactosidase was used as tracer in a double-determinant assay. We compared the assay ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.268656
更新日期:2017-05-01 00:00:00