Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

Abstract:

:In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. After the membrane strips are cleared and stained, the two fractions are quantified densitometrically. As evaluated by use with blood from diabetics, results compare well with those by chromatography on short columns and by electrophoresis in commercial agar gel films.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Ambler J,Janik B,Walker G

subject

Has Abstract

pub_date

1983-02-01 00:00:00

pages

340-3

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

29

pub_type

杂志文章
  • Serum lipoperoxidation products in an infant with hemolytic-uremic syndrome.

    abstract::We detected increased concentrations of lipoperoxidation products, as malondialdehyde, in the serum of an infant with classic hemolytic-uremic syndrome. The concentrations declined when peritoneal dialysis was initiated and eventually returned to normal after clinical recovery. Our observation adds to the existing bod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown RE,Alade SL,Knight JA,Evans BJ

    更新日期:1988-11-01 00:00:00

  • A direct radioimmunoassay for aldosterone in plasma.

    abstract::This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lun S,Espiner EA,Nicholls MG,Yandle TG

    更新日期:1983-02-01 00:00:00

  • Faster determination of clottable fibrinogen in human plasma: an improved method and kinetic study.

    abstract::Clottable fibrinogen in human plasma was determined by measuring spectrophotometrically the increase in turbidity with time due to the fibrinogen-fibrin conversion with thrombin. From the maximal absorbance, Amax, at 450 nm obtained 2 min or less after thrombin as added to plasma, we estimated the fibrinogen concentra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Inada Y,Okamoto H,Kanai S,Tamaura Y

    更新日期:1978-02-01 00:00:00

  • Measurement of elastase and cysteine proteinases in synovial fluid of patients with rheumatoid arthritis, sero-negative spondylarthropathies, and osteoarthritis.

    abstract::Synovial fluid samples were collected from 45 patients with rheumatoid arthritis, spondylarthropathy, or osteoarthritis, to study their content of elastase (EC 3.4.21.37) and of cysteine proteinases (EC 3.4.22.1, 3.4.22.15). We measured both elastase complexed with alpha 1-proteinase inhibitor and elastase activity to...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huet G,Flipo RM,Richet C,Thiebaut C,Demeyer D,Balduyck M,Duquesnoy B,Degand P

    更新日期:1992-09-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Low proportions of glycosylated hemoglobin associated with hemoglobin S and hemoglobin C.

    abstract::Using a cation-exchange chromatographic method, we found normal or subnormal values for glycosylated hemoglobin in a few diabetic patients with persistent hyperglycemia. Subsequent investigations revealed that these unexpected results had originated from black patients with diabetes. In view of common occurrence of ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aleyassine H

    更新日期:1979-08-01 00:00:00

  • The Longer, the Better? An Empirical Study of the Extent and Mechanisms of Attenuating Biomarker Associations in Cardiovascular Patient Cohorts.

    abstract:BACKGROUND:Identifying novel risk markers in cardiovascular patients remains a research priority. Longer follow-up generally is considered favorable in such studies, but associations of interest may become attenuated with increasing follow-up. This issue has not been adequately addressed in the context of patient cohor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.263202

    authors: Breitling LP,Mons U,Hahmann H,Koenig W,Rothenbacher D,Brenner H

    更新日期:2017-03-01 00:00:00

  • The haptoglobin 2-2 phenotype affects serum markers of iron status in healthy males.

    abstract:BACKGROUND:Human iron status is influenced by environmental and genetic factors. We hypothesized that the genetic polymorphism of haptoglobin (Hp), a hemoglobin-binding plasma protein, could affect iron status. METHODS:Reference values of serum iron status markers were compared according to Hp phenotypes (Hp 1-1, Hp 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Langlois MR,Martin ME,Boelaert JR,Beaumont C,Taes YE,De Buyzere ML,Bernard DR,Neels HM,Delanghe JR

    更新日期:2000-10-01 00:00:00

  • Diagnosis of dopa-responsive dystonia and other tetrahydrobiopterin disorders by the study of biopterin metabolism in fibroblasts.

    abstract:BACKGROUND:Dopa-responsive dystonia (DRD) and tetrahydrobiopterin (BH4) defects are inherited disorders characterized by monoamine neurotransmitter deficiency with decreased activity of one of the BH4-metabolizing enzymes. The aim of the study was to determine the utility of cultured skin fibroblasts for the diagnosis ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bonafé L,Thöny B,Leimbacher W,Kierat L,Blau N

    更新日期:2001-03-01 00:00:00

  • Cobalamin deficiency in general practice. Assessment of the diagnostic utility and cost-benefit analysis of methylmalonic acid determination in relation to current diagnostic strategies.

    abstract::Diagnosing cobalamin deficiency is often difficult. We investigated the diagnostic strategies that 224 general practitioners used to assess cobalamin status and the criteria on which they based their decisions to supplement patients. From all serum cobalamin analyses carried out at a single laboratory during 1993, ind...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hølleland G,Schneede J,Ueland PM,Lund PK,Refsum H,Sandberg S

    更新日期:1999-02-01 00:00:00

  • Applications of recombinant DNA to pathologic diagnosis.

    abstract::Recombinant DNA techniques are contributing to the understanding of the pathogeneses of genetic, neoplastic, and viral diseases, and are used in the diagnosis of certain genetic and viral diseases. Such techniques will have wider application in the future and will play an increasing role in the clinical laboratory. Th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sauls CD,Caskey CT

    更新日期:1985-06-01 00:00:00

  • Ten electrophoretic methods compared with a selected method for quantifying lactate dehydrogenase isoenzymes in serum.

    abstract::Using the Selected Method of McKenzie and Henderson (Selected Methods Clin Chem 1983;10:59-67) as a reference method, we compared the performance of 10 commercially available methods for determination of lactate dehydrogenase (LD, EC 1.1.1.27) isoenzymes. Results were expressed as percentage of total LD activity, as d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moses GC,Ross ML,Henderson AR

    更新日期:1988-09-01 00:00:00

  • Evaluation of an acidic deproteinization for the measurement of ascorbate and dehydroascorbate in plasma samples.

    abstract::The most popular pretreatment method of plasma samples for the measurement of ascorbate (AsA) and dehydroascorbate (DHA) has been an acidic deproteinization via metaphosphoric acid or trichloroacetic acid. In general, DHA is absent in plasma samples prepared from human blood in a conventional manner. However, when the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koshiishi I,Mamura Y,Liu J,Imanari T

    更新日期:1998-04-01 00:00:00

  • Determination of tamoxifen and four metabolites in serum by low-dispersion liquid chromatography.

    abstract::In this assay of tamoxifen and four metabolites in human serum, the serum samples are deproteinized with an equal volume of acetonitrile, then injected into a small (0.21 X 2 cm) precolumn packed with 5-micron-diameter octadecylsilane (ODS) particles. The samples are concentrated on-column by equilibrating the column ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lien EA,Ueland PM,Solheim E,Kvinnsland S

    更新日期:1987-09-01 00:00:00

  • Serum-constituents analyses: effect of duration and temperature of storage of clotted blood.

    abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ono T,Kitaguchi K,Takehara M,Shiiba M,Hayami K

    更新日期:1981-01-01 00:00:00

  • Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: study within the framework of the Dutch project "Calibration 2000".

    abstract:BACKGROUND:The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). METHODS:Sixteen PRMs were prepared either ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Cobbaert C,Weykamp C,Baadenhuijsen H,Kuypers A,Lindemans J,Jansen R

    更新日期:2002-09-01 00:00:00

  • Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

    abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127241

    authors: Kavsak PA,Wang X,Ko DT,MacRae AR,Jaffe AS

    更新日期:2009-10-01 00:00:00

  • Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.

    abstract::Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and H...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: März W,Siekmeier R,Scharnagl H,Seiffert UB,Gross W

    更新日期:1993-11-01 00:00:00

  • Thyroxine, thyrotropin, and age in a euthyroid hospital patient population.

    abstract::The diagnosis of thyroid disease now often can be achieved reliably by measuring thyrotropin (TSH) alone. Thyroxine (T4), triiodothyronine, and other analytes are only needed if TSH and the accompanying clinical condition are discordant. We describe here work that confirms the age independence of TSH in both inpatient...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davey R

    更新日期:1997-11-01 00:00:00

  • Liquid-chromatographic profiling of solutes in serum of uremic patients undergoing hemodialysis and chronic ambulatory peritoneal dialysis (CAPD); high concentrations of pseudouridine in CAPD patients.

    abstract::Using "high performance" liquid chromatography, we studied non-protein-bound fractions and total concentrations of 18 solutes accumulating in sera from a group of 12 patients who were undergoing chronic ambulatory peritoneal dialysis (CAPD) and in predialysis sera from a group of 15 hemodialysis (HD) patients. We moni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schoots AC,Gerlag PG,Mulder AW,Peeters JA,Cramers CA

    更新日期:1988-01-01 00:00:00

  • Ultraviolet fluorescence of human sera: I. Sources of characteristic differences in the ultraviolet fluorescence spectra of sera from normal and cancer-bearing humans.

    abstract::The ultraviolet fluorescence emission spectra of sera from apparently healthy persons and of sera from cancer patients frequently show significantly different curve shapes. A biparametric fluorescence method has been developed to use these deviations to detect patients with malignant diseases (Clin Chem 1986;32:1974-8...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hubmann MR,Leiner MJ,Schaur RJ

    更新日期:1990-11-01 00:00:00

  • Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol.

    abstract::We evaluated the performance of two homogeneous assays for quantifying HDL cholesterol (HDL-C) and compared them with the phosphotungstic acid (PTA)/ MgCl2 assay. Both homogeneous HDL-C assays were precise, having a within-run CV of < 1.20% and a between-run CV of < 4.07%. The HDL-C values (y) measured by the two homo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huang YC,Kao JT,Tsai KS

    更新日期:1997-06-01 00:00:00

  • Detection of mitochondrial DNA mutations by temporal temperature gradient gel electrophoresis.

    abstract:BACKGROUND:A unique requirement for the molecular diagnosis of mitochondrial DNA (mtDNA) disorders is the ability to detect heteroplasmic mtDNA mutations and to distinguish them from homoplasmic sequence variations before further testing (e.g., sequencing) is performed. We evaluated the potential utility of temporal te...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Chen TJ,Boles RG,Wong LJ

    更新日期:1999-08-01 00:00:00

  • Phase-separation immunoassays.

    abstract::Solid-phase-based immunoassays have traditionally been plagued by nonspecific binding to the solid phase and by slow reaction kinetics relative to reactants that are free to diffuse in solution. We have developed two novel immunoassays in which the solid phase is generated in situ after the specific binding reaction h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Auditore-Hargreaves K,Houghton RL,Monji N,Priest JH,Hoffman AS,Nowinski RC

    更新日期:1987-09-01 00:00:00

  • Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability.

    abstract::Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lott JA,Smith DA,Mitchell LC,Moeschberger ML

    更新日期:1996-06-01 00:00:00

  • Improved column method for separating lactate dehydrogenase isoenzymes 1 and 2.

    abstract::Lactate dehydrogenase (LD) isoenzymes 1 and 2 in human serum were separated on a column of diethylaminoethyl-Sephadex. Samples layered on mini-columns were eluted with buffered sodium chloride (100, 150, and 200 mmol/liter). Lactate dehydrogenase activity in column effluents was measured by the Wacker method, and thei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mercer DW

    更新日期:1978-03-01 00:00:00

  • Diagnosis of hemolytic disease by electrophoresis of erythrocyte lactate dehydrogenase isoenzymes on cellulose acetate or Agarose.

    abstract::We determined the LD-1/LD-2 isoenzyme ratio in hemolysates of erythrocytes by electrophoresis on cellulose acetate and on agarose. A ratio exceeding 1.0 was found with the former but not the latter. Results were similar for in vitro models of hemolytic disorders. Using cellulose acetate electrophoresis, we determined ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Marchand A,Galen RS

    更新日期:1981-08-01 00:00:00

  • Inhibitory effects of micronized fenofibrate on carotid atherosclerosis in patients with essential hypertension.

    abstract:BACKGROUND:The coexistence of hypertension and dyslipidemia synergistically increases the risk of cardiovascular events. We investigated the effect of the lipid-lowering agent micronized fenofibrate on inhibition of carotid atherosclerosis in patients with essential hypertension and mild hyperlipidemia. METHODS:We mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.074724

    authors: Zhu S,Su G,Meng QH

    更新日期:2006-11-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • A model for the effect of bias for cholesterol on the population at risk.

    abstract::The location of the Reference Value for an analyte within the population distribution affects the magnitude of error due to methodological bias. Using the gaussian distribution, we evaluated the effects of systematic and proportional biases of the method (positive and negative), mean value, and standard deviation on t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Ruddel M,Elin RJ

    更新日期:1988-11-01 00:00:00