The haptoglobin 2-2 phenotype affects serum markers of iron status in healthy males.

Abstract:

BACKGROUND:Human iron status is influenced by environmental and genetic factors. We hypothesized that the genetic polymorphism of haptoglobin (Hp), a hemoglobin-binding plasma protein, could affect iron status. METHODS:Reference values of serum iron status markers were compared according to Hp phenotypes (Hp 1-1, Hp 2-1, Hp 2-2; determined by starch gel electrophoresis) in 717 healthy adults. Iron storage was investigated in peripheral blood monocyte-macrophages by measuring cytosolic L- and H-ferritins and by in vitro uptake of radiolabeled ((125)I) hemoglobin-haptoglobin complexes. RESULTS:In males but not in females, the Hp 2-2 phenotype was associated with higher serum iron (P <0.05), transferrin saturation (P <0.05), and ferritin (P <0.01) concentrations than Hp 1-1 and 2-1, whereas soluble transferrin receptor concentrations were lower (P <0.05). Moreover, serum ferritin correlated with monocyte L-ferritin content (r = 0.699), which was also highest in the male Hp 2-2 subgroup (P <0.01). In vitro, monocyte-macrophages took up a small fraction of (125)I-labeled hemoglobin complexed to Hp 2-2 but not to Hp 1-1 or 2-1. CONCLUSIONS:The Hp 2-2 phenotype affects serum iron status markers in healthy males and is associated with higher L-ferritin concentrations in monocyte-macrophages because of a yet undescribed iron delocalization pathway, selectively occurring in Hp 2-2 subjects.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Langlois MR,Martin ME,Boelaert JR,Beaumont C,Taes YE,De Buyzere ML,Bernard DR,Neels HM,Delanghe JR

subject

Has Abstract

pub_date

2000-10-01 00:00:00

pages

1619-25

issue

10

eissn

0009-9147

issn

1530-8561

journal_volume

46

pub_type

杂志文章
  • Bioassay of thyroid-stimulating immunoglobulin in cryopreserved human thyroid cells: optimization and clinical evaluation.

    abstract::We have explored the method of Rapoport et al. (J Clin Endocrinol Metab 1984;58:332-8) for the bioassay of thyroid-stimulating immunoglobulin (TSI) in cultured human thyroid cells, to optimize the assay and to evaluate its utility in clinical diagnosis and management of patients with autoimmune thyroid disease. Here w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kraiem Z,Glaser B,Pauker J,Sadeh O,Sheinfeld M

    更新日期:1988-02-01 00:00:00

  • Liquid-chromatographic measurement of taurine in cerebrospinal fluid of normal individuals and patients with meningitis.

    abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,White JP

    更新日期:1979-08-01 00:00:00

  • Application of a sequence-specific radioimmunoassay for the carboxyl-terminal region of corticotropin.

    abstract::The carboxyl terminal region of corticotropin (ACTH), (Ala34-Phe-Pro-Glu-Leu-Phe39), a region of the hormone conserved during evolution, served as an antigen for the production of a sequence-specific antiserum. In a radioimmunoassay, peptides that extend toward the amino terminal from Ala34, such as [Tyr,Gly]-ACTH34-3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lazarus LH,DiAugustine RP,Khan MN,Jahnke GD,Erisman MD

    更新日期:1981-04-01 00:00:00

  • Is succinyldicholine the substrate of choice for the measurement of cholinesterase activity?

    abstract::We have developed a succinyldicholine-based assay for serum cholinesterase (EC 3.1.1.8) to help establish whether patients with suspected sensitivity to drugs of this type have enzyme abnormalities that cannot be detected by conventional laboratory techniques. Although the method discriminates between cholinesterase a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Faye S,Evans RT

    更新日期:1986-08-01 00:00:00

  • Simultaneous assay of corticosterone and cortisol in plasma by reversed-phase liquid chromatography.

    abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hariharan M,Naga S,VanNoord T,Kindt EK

    更新日期:1992-03-01 00:00:00

  • Mechanized amidolytic technique for determination of factor X and factor-X antigen, and its application to patients being treated with oral anticoagulants.

    abstract::We describe a mechanized chromogenic assay for factor X, the results of which correlate well with those for the one-stage clotting assays for factor X in which it is activated either via the extrinsic pathway by thromboplastin or directly by Russell's viper venom. We purified human factor X and raised monospecific ant...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: van Wijk EM,Kahlé LH,ten Cate JW

    更新日期:1980-06-01 00:00:00

  • One-step chemiluminescent immunoassay of free thyroxin with acridinium-ester-labeled thyroxin evaluated and compared with a two-step radioimmunoassay.

    abstract::This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantifi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bounaud JY,Bounaud MP,Begon F

    更新日期:1988-12-01 00:00:00

  • New immunoenzymatic assay for human thyrotropin compared with two radioimmunoassays.

    abstract::We have evaluated a new immunoenzymatic assay for human thyrotropin involving three monoclonal antibodies (Abbott HTSH EIA) and compared the results with those of two conventional nonequilibrium double-antibody radioimmunoassay (RIA) methods: Clinical Assays' RIA and a research RIA (J Clin Endocrinol Metab 1975; 41:67...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Turner LF Jr,Hershman JM

    更新日期:1986-03-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • Automated measurement of amylase isoenzymes by a double kinetic assay with "blocked" beta-2-chloro-4-nitrophenyl maltopentaoside as substrate and with wheat germ inhibitor.

    abstract::We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Nishimura T,Noma A,Hamano K

    更新日期:1991-08-01 00:00:00

  • Computerized multicuvette system for single substance and group analysis and for the chromatographic isolation and quantitation of compounds in complex mixtures.

    abstract::A new computer-interfaced system of general applicability in the clinical laboratory has been built. The system is constructed around a new type multicuvette. Quantitation is currently by spectrophotometry and is on-line, with use of a mini-computer with output going to an electrostatic printer/plotter. The system can...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vestergaard P,Bachman A

    更新日期:1975-08-01 00:00:00

  • Prognostic value of chromogranin A at admission in critically ill patients: a cohort study in a medical intensive care unit.

    abstract:BACKGROUND:Risk assessments of patients should be based on objective variables, such as biological markers that can be measured routinely. The acute response to stress causes the release of catecholamines from the adrenal medulla accompanied by chromogranin A (CGA). To date, no study has evaluated the prognostic value ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.102442

    authors: Zhang D,Lavaux T,Voegeli AC,Lavigne T,Castelain V,Meyer N,Sapin R,Aunis D,Metz-Boutigue MH,Schneider F

    更新日期:2008-09-01 00:00:00

  • Hyperamylasemia, specific pancreatic enzymes, and hypoxanthine during recovery from diabetic ketoacidosis.

    abstract::The contribution of the exocrine pancreas to hyperamylasemia in diabetic ketoacidosis was investigated by measuring total amylase, salivary and pancreatic isoamylases, cathodic trypsin-like immunoreactivity, and pancreatic lipase in 12 consecutive patients recovering from diabetic ketoacidosis. Hyperamylasemia was pre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Møller-Petersen J,Andersen PT,Hjørne N,Ditzel J

    更新日期:1985-12-01 00:00:00

  • Predictive markers in breast and other cancers: a review.

    abstract:BACKGROUND:Unpredictable efficacy and toxicity are hallmarks of most anticancer therapies. Predictive markers are factors that are associated with response or resistance to a particular therapy. METHODS:The English literature relating to predictive markers in oncology was reviewed. Particular attention was paid to met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2004.046227

    authors: Duffy MJ

    更新日期:2005-03-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • Direct multiplex assay of lysosomal enzymes in dried blood spots for newborn screening.

    abstract:BACKGROUND:Newborn screening for deficiency in the lysosomal enzymes that cause Fabry, Gaucher, Krabbe, Niemann-Pick A/B, and Pompe diseases is warranted because treatment for these syndromes is now available or anticipated in the near feature. We describe a multiplex screening method for all five lysosomal enzymes tha...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.035907

    authors: Li Y,Scott CR,Chamoles NA,Ghavami A,Pinto BM,Turecek F,Gelb MH

    更新日期:2004-10-01 00:00:00

  • Next-generation sequencing: from basic research to diagnostics.

    abstract:BACKGROUND:For the past 30 years, the Sanger method has been the dominant approach and gold standard for DNA sequencing. The commercial launch of the first massively parallel pyrosequencing platform in 2005 ushered in the new era of high-throughput genomic analysis now referred to as next-generation sequencing (NGS). ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.112789

    authors: Voelkerding KV,Dames SA,Durtschi JD

    更新日期:2009-04-01 00:00:00

  • Prognostic value of combined data on enzymes and inflammation markers in plasma in cases of severe head injury.

    abstract::We measured certain enzyme activities (aldolase, aspartate aminotransferase, creatine kinase, and lactate dehydrogenase) and inflammation markers (alpha 1-antitrypsin, C-reactive protein, fibrinogen, and leukocytes) each day for four days in plasma of patients with severe head injury. The univariate prognostic efficie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bourguignat A,Albert A,Férard G,Tulasne PA,Kempf I,Métais P

    更新日期:1983-11-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • Borderline increases in albumin excretion rate and the relation to glycemic control in subjects with type I diabetes.

    abstract::We evaluated "borderline" increases in overnight albumin excretion rates (AERs)----i.e., those between the upper 95th percentile of normal (7.6 micrograms/min) and the lowest value currently considered predictive of nephropathy (30 micrograms/min)----to determine their importance and to see whether glucose control inf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chase HP,Marshall G,Garg SK,Harris S,Osberg I

    更新日期:1991-12-01 00:00:00

  • Carcinoembryonic antigen as a marker for colorectal cancer: is it clinically useful?

    abstract:BACKGROUND:Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers worldwide. Its main application is mostly in gastrointestinal cancers, especially in colorectal malignancy. Although in use for almost 30 years, the clinical value of CEA in colorectal cancer is still not clear. METHODS:The literatu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Duffy MJ

    更新日期:2001-04-01 00:00:00

  • Serum immunoglobulins after surgical operation.

    abstract::We measured immunoglobulins in the sera of 33 patients on days 1, 3, 6, 10, and 17 and three to four weeks after surgical operations (mostly hysterectomy or appendectomy) or (six patients) after spinal injury. In the absence of infection or blood transfusion, IgG usually decreased slightly and transiently after hyster...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fuller JM,Keyser JW

    更新日期:1975-05-01 00:00:00

  • LOX index, a novel predictive biochemical marker for coronary heart disease and stroke.

    abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140707

    authors: Inoue N,Okamura T,Kokubo Y,Fujita Y,Sato Y,Nakanishi M,Yanagida K,Kakino A,Iwamoto S,Watanabe M,Ogura S,Otsui K,Matsuda H,Uchida K,Yoshimoto R,Sawamura T

    更新日期:2010-04-01 00:00:00

  • Urokinase plasminogen activator: a prognostic marker in breast cancer including patients with axillary node-negative disease.

    abstract::Urokinase plasminogen activator (uPA) is a serine protease causally involved in cancer invasion and metastasis. In this study, high concentrations of uPA in primary breast cancers were independently associated with both a shortened disease-free interval and overall survival. For the disease-free interval as endpoint, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duffy MJ,Duggan C,Mulcahy HE,McDermott EW,O'Higgins NJ

    更新日期:1998-06-01 00:00:00

  • Toxicity of free p-cresol: a prospective and cross-sectional analysis.

    abstract:BACKGROUND:Uremic syndrome is the consequence of the retention of solutes usually cleared by the healthy kidneys. p-Cresol can be considered a prototypic protein-bound uremic toxin. It is conceivable, analogous with drugs, that the non-protein-bound fraction of p-cresol exerts toxicity. This aspect had never been evalu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.3.470

    authors: De Smet R,Van Kaer J,Van Vlem B,De Cubber A,Brunet P,Lameire N,Vanholder R

    更新日期:2003-03-01 00:00:00

  • Microscale ultrafiltration technique for determining free drug in 50-microL serum samples.

    abstract::This ultrafiltration technique allows determination of free drug in 50 microL of serum. We ultrafiltered sera containing the following drugs--valproic acid (and its major metabolites), phenobarbital, diazepam, indomethacin, phenytoin, furosemide, and chloramphenicol--using both the commercially available micropartitio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wittfoht W,Duwe K,Kuhnz W,Nau H

    更新日期:1984-06-01 00:00:00

  • Homogeneous apoenzyme reactivation immunoassay for thyroxin-binding globulin in serum.

    abstract::In this automated apoenzyme reactivation immunoassay system (Ames Optimate) for thyroxin-binding globulin (TBG), the sample and N6-aminohexylflavin adenine dinucleotide-labeled TBG react sequentially with antiserum. Then apoglucose oxidase is added to combine with the free fraction and generate glucose oxidase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schroeder HR,Johnson PK,Dean CL,Morris DL,Smith D,Refetoff S

    更新日期:1986-05-01 00:00:00

  • External quality assurance program for PCR amplification of genomic DNA: an Italian experience.

    abstract:BACKGROUND:External quality assurance (EQA) programs for diagnostic tests based on nucleic acid amplification have not been widely implemented in clinical laboratories and remain limited to few tests. Development of specific EQA programs based on application-based proficiency testing for any diagnostic molecular target...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.5.782

    authors: Raggi CC,Pinzani P,Paradiso A,Pazzagli M,Orlando C

    更新日期:2003-05-01 00:00:00

  • Delivering clinical laboratory services to intensive care units.

    abstract::In response to the pressures of cost reduction, we established and evaluated a carefully integrated program to deliver clinical laboratory services more promptly and efficiently to the intensive care units (ICUs). The new protocol reduced the steps and turnaround time from ordering tests by physicians to reporting res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steffes MW,Gillen JL,Fuhrman SA

    更新日期:1996-03-01 00:00:00