Serum immunoglobulins after surgical operation.

Abstract:

:We measured immunoglobulins in the sera of 33 patients on days 1, 3, 6, 10, and 17 and three to four weeks after surgical operations (mostly hysterectomy or appendectomy) or (six patients) after spinal injury. In the absence of infection or blood transfusion, IgG usually decreased slightly and transiently after hysterectomy or appendectomy, as did IgA or IgM after hysterectomy. IgD concentrations showed no consistent changes, but in one patient after hysterectomy and with minimal infection IgD concentration decreased sharply, which contrasted with significant and early increases in IgG, IgA, and IgM. IgD concentration was not correlated with type of operation, presence of infection, or changes in the other immunoglobulins. IgE concentrations either die not change or, in some patients, increased or decreased initially, after operation. We conclude that immunoglobulin concentrations in serum are subject to multiple, unpredictable influences after trauma.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Fuller JM,Keyser JW

subject

Has Abstract

pub_date

1975-05-01 00:00:00

pages

667-71

issue

6

eissn

0009-9147

issn

1530-8561

journal_volume

21

pub_type

杂志文章
  • Aspartate aminotransferase macroenzyme complex in serum identified and characterized.

    abstract::Macromolecular aspartate aminotransferase was found in the serum of an apparently healthy patient. This complex was composed of aspartate aminotransferase (AST; EC 2.6.1.1) and immunoglobulin. Electrophoresis of the patient's serum showed an abnormal band migrating between mitochondrial (m) and cytosolic (s) AST. The ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stasia MJ,Surla A,Renversez JC,Pene F,Morel-Femelez A,Morel F

    更新日期:1994-07-01 00:00:00

  • Production of murine hybrid-hybridomas secreting bispecific monoclonal antibodies for use in urease-based immunoassays.

    abstract::To produce bispecific antibodies (BiAbs) for enzyme immunoassay (EIA) to replace antibody-enzyme conjugates, we developed a panel of 8-azaguanine/ouabain-resistant anti-urease variant hybridoma cell lines for use in hybridoma-hybridoma fusions. These variants represent mouse immunoglobulin subclasses IgM, IgG1, IgG2a,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Takahashi M,Fuller SA

    更新日期:1988-09-01 00:00:00

  • Energy-dispersive x-ray fluorescence spectroscopy and inductively coupled plasma emission spectrometry evaluated for multielement analysis in complex biological matrices.

    abstract::Energy-dispersive x-ray spectroscopy and inductively coupled plasma emission spectrometry were evaluated as methods for routine multielement analysis of biological material. Standard samples included Standard Reference Materials (National Bureau of Standards), compounded mixtures, and supplements that provided a wide ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Irons RD,Schenk EA,Giauque RD

    更新日期:1976-12-01 00:00:00

  • Presence of donor-derived DNA and cells in the urine of sex-mismatched hematopoietic stem cell transplant recipients: implication for the transrenal hypothesis.

    abstract:BACKGROUND:The term "transrenal DNA" was coined in 2000 to signify that DNA in urine may come from the passage of plasma DNA through the kidney barrier. Although DNA in the urine has the potential to provide a completely noninvasive source of nucleic acids for molecular diagnosis, its existence remains controversial. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.113530

    authors: Hung EC,Shing TK,Chim SS,Yeung PC,Chan RW,Chik KW,Lee V,Tsui NB,Li CK,Wong CS,Chiu RW,Lo YM

    更新日期:2009-04-01 00:00:00

  • Elimination of glucose interference and improved precision in a continuous-flow analysis for inulin.

    abstract::A modified fermentation procedure based on one described by Homer Smith in his textbook was used to eliminate glucose interference in the automated detrmination of inulin. The manifold of Fjeldbo and Stamey [J. Lab. Clin. Med. 72, 353 (1968)] was modified to enable us to insert the fermentation procedure without sacri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Torelli JA,Middleton B,Stein RM

    更新日期:1977-07-01 00:00:00

  • Quantitative nephelometric assay for determining myoglobin evaluated.

    abstract::A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,Chapelle JP,Vanderschueren SC

    更新日期:1990-09-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Bioassay of thyroid-stimulating immunoglobulin in cryopreserved human thyroid cells: optimization and clinical evaluation.

    abstract::We have explored the method of Rapoport et al. (J Clin Endocrinol Metab 1984;58:332-8) for the bioassay of thyroid-stimulating immunoglobulin (TSI) in cultured human thyroid cells, to optimize the assay and to evaluate its utility in clinical diagnosis and management of patients with autoimmune thyroid disease. Here w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kraiem Z,Glaser B,Pauker J,Sadeh O,Sheinfeld M

    更新日期:1988-02-01 00:00:00

  • Increases of cardiac troponin in conditions other than acute coronary syndrome and heart failure.

    abstract:BACKGROUND:Although cardiac troponin (cTn) is a cornerstone marker in the assessment and management of patients with acute coronary syndrome (ACS) and heart failure (HF), cTn is not diagnostically specific for any single myocardial disease process. This narrative review discusses increases in cTn that result from acute...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2009.130799

    authors: Kelley WE,Januzzi JL,Christenson RH

    更新日期:2009-12-01 00:00:00

  • Interference by p-hydroxyphenobarbital in the 125I-radioimmunoassay of serum and urinary phenobarbital.

    abstract::A radioimmunoassay for barbiturates is shown to be equally sensitive to phenobarbital and its major urinary metabolite, p-hydroxyphenobarbital, in serum and urine. Interference by the metabolite can be essentially eliminated by selectively extracting phenobarbital into chloroform. The extraction efficiency of the meth...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Viswanathan CT,Booker HE,Welling PG

    更新日期:1977-05-01 00:00:00

  • Chemiluminescent assay of alkaline phosphatase applied in an ultrasensitive enzyme immunoassay of thyrotropin.

    abstract::We compared a chemiluminescent assay and a colorimetric endpoint assay for measuring an alkaline phosphatase (EC 3.1.3.1) label in an enzyme immunoassay of thyrotropin (TSH). The substrate in the chemiluminescent assay is a derivative of adamantyl 1,2-dioxetane phosphate. On dephosphorylation, catalyzed by alkaline ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bronstein I,Voyta JC,Thorpe GH,Kricka LJ,Armstrong G

    更新日期:1989-07-01 00:00:00

  • Sandwich ELISA Using a Mouse/Human Chimeric CSLEX-1 Antibody.

    abstract:BACKGROUND:An assay using a mouse antisialyl Lewis X (sLeX) antibody (CSLEX-1) is used clinically for screening and monitoring patients with breast cancer in Japan. However, the IgM isoform of CSLEX-1 is not preferred for the assay because the bulkiness of IgM generally causes poor accessibility to the antigen. To solv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.260968

    authors: Yamashita J,Kobayashi I,Tatematsu K,Sezutsu H,Noda K,Ishihara H

    更新日期:2016-11-01 00:00:00

  • New dual monoclonal ELISA for measuring plasma osteopontin as a biomarker associated with survival in prostate cancer: clinical validation and comparison of multiple ELISAs.

    abstract:BACKGROUND:A previously developed monoclonal/polyclonal ELISA (Mono/Poly) to detect plasma concentrations of osteopontin (OPN) was shown to provide prognostic information in breast, prostate, and other cancers. Here we describe the clinical validation of a new dual monoclonal (Dual Mono) assay. We compared both assays ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.117465

    authors: Anborgh PH,Wilson SM,Tuck AB,Winquist E,Schmidt N,Hart R,Kon S,Maeda M,Uede T,Stitt LW,Chambers AF

    更新日期:2009-05-01 00:00:00

  • A model for the effect of bias for cholesterol on the population at risk.

    abstract::The location of the Reference Value for an analyte within the population distribution affects the magnitude of error due to methodological bias. Using the gaussian distribution, we evaluated the effects of systematic and proportional biases of the method (positive and negative), mean value, and standard deviation on t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Ruddel M,Elin RJ

    更新日期:1988-11-01 00:00:00

  • Analytical performance of 4 automated assays for measurement of cystatin C.

    abstract:BACKGROUND:We evaluated the analytical performance of 4 cystatin C assays (Siemens N Latex on BNII, Roche Tina-quant on Cobas c501, Genzyme on Cobas c501, and Tosoh ST AIA-PACK on Tosoh AIA-600II) according to guidelines published by the Clinical and Laboratory Standards Institute. METHODS:We evaluated total imprecisi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.141531

    authors: Li J,Dunn W,Breaud A,Elliott D,Sokoll LJ,Clarke W

    更新日期:2010-08-01 00:00:00

  • Gas-chromatographic determination of mephenytoin and desmethylmephenytoin, after off-column alkylation.

    abstract::We describe a gas-liquid chromatographic method for determining mephenytoin and its active metabolite, desmethylmephenytoin, in human serum. 5-Methyl-5-phenylhydantoin is used as the internal standard. The method involves extraction of the drugs by adsorption onto charcoal and off-column derivatization to their pentyl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raisys VA,Zebelman AM,MacMillan SF

    更新日期:1979-01-01 00:00:00

  • Simple spectrophotometric determination of urinary albumin by dye-binding with use of bromphenol blue.

    abstract::This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schosinsky KH,Vargas M,Luz Esquivel A,Chavarria MA

    更新日期:1987-02-01 00:00:00

  • Magnetizable solid-phase fluoroimmunoassay of thyroxine by a sequential addition technique.

    abstract::We describe a simple fluoroimmunoassay for the determination of thyroxine concentrations in serum. The method, "sequential addition, separation fluoroimmunoassay," involves both thyroxine labeled with fluorescein and magnetizable cellulose/iron oxide particles to which antibodies to thyroxine have been covalently link...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nargessi RD,Ackland J,Hassan M,Forrest GC,Smith DS,Landon J

    更新日期:1980-11-01 00:00:00

  • Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

    abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garber CC

    更新日期:1981-08-01 00:00:00

  • Detection of alpha 1-antitrypsin Z and S mutations by polymerase chain reaction-mediated site-directed mutagenesis.

    abstract::alpha 1-Antitrypsin (A1AT) deficiency is a relatively common autosomal recessive disease, resulting most often from a single base pair (1 bp) substitution called the Z mutation. Previous genetic tests for carriers and affected patients have relied on quantitative binding of radioactive probes to an amplified gene prod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tazelaar JP,Friedman KJ,Kline RS,Guthrie ML,Farber RA

    更新日期:1992-08-01 00:00:00

  • Simple and sensitive determination of urea in serum and urine.

    abstract::In this method for serum and urinary urea determination, the same reagent is used without predilution of urine samples. The method is based on the pH increase resulting from the ammonia released by urease hydrolysis of urea. o-Cresolphthalein complexone is used to monitor the pH change colorimetrically. Urea concentra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orsonneau JL,Massoubre C,Cabanes M,Lustenberger P

    更新日期:1992-05-01 00:00:00

  • Candidate gene genotypes, along with conventional risk factor assessment, improve estimation of coronary heart disease risk in healthy UK men.

    abstract:BACKGROUND:One of the aims of cardiovascular genetics is to test the efficacy of the use of genetic information to predict cardiovascular risk. We therefore investigated whether inclusion of a set of common variants in candidate genes along with conventional risk factor (CRF) assessment enhanced coronary heart disease ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.074591

    authors: Humphries SE,Cooper JA,Talmud PJ,Miller GJ

    更新日期:2007-01-01 00:00:00

  • Cardiac troponins I and T in patients with suspected acute coronary syndrome: a comparative study in a routine setting.

    abstract::We compared cardiac troponin I (cTnI), using Access, Sanofi Pasteur, and cardiac troponin T (cTnT), using Elecsys, Boehringer Mannheim, in the first two routine blood samplings in a routine panel of cardiac markers for the biochemical diagnostic evaluation of patients with symptoms of acute myocardial infarction (AMI)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hetland O,Dickstein K

    更新日期:1998-07-01 00:00:00

  • A homogeneous fluorescent immunoassay for human immunoglobulin M.

    abstract::We describe a homogeneous substrate-labeled fluorescent immunoassay for human IgM. In this competitive-binding method we use a fluorogenic substrate for Escherichia coli beta-galactosidase, N-(6-aminohexyl)-7-beta-galactosyl-coumarin-3-carboxamide, which is covalently coupled to IgM. The fluorescence emission intensit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Worah D,Yeung KK,Ward FE,Carrico RJ

    更新日期:1981-05-01 00:00:00

  • Effect of assay methodology on pharmacokinetic differences between cyclosporine Neoral and Sandimmune formulations.

    abstract::The new oral formulation of cyclosporine (CsA), Neoral (CsA-N), results in increased area under the curve (AUC) and decreased intra- and interindividual variation in blood concentrations and other pharmacokinetic (PK) parameters when compared with the current Sand-immune (CsA-S) formulation. The present study examines...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aspeslet LJ,LeGatt DF,Murphy G,Yatscoff RW

    更新日期:1997-01-01 00:00:00

  • Potential of electrospray mass spectrometry for quantifying glycohemoglobin.

    abstract::An electrospray ionization-mass spectrometric procedure has been developed for determining glycohemoglobin. Whole-blood samples from 78 diabetic and 50 nondiabetic subjects (glycation range 3-15%, as determined by electrospray mass spectrometry) were diluted 500-fold in an acidic denaturing solvent and introduced dire...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Roberts NB,Green BN,Morris M

    更新日期:1997-05-01 00:00:00

  • Comparison of acid phosphatase isoenzymes of human seminal fluid, prostate, and leukocytes.

    abstract::We used ion-exchange column chromatography and electrophoresis on polyacrylamide gel to compare the acid phosphatase isoenzymes of prostate and leukocytes. The major isoenzyme of the prostate is band 2A; only a trace of band 2B was observed. However, the major isoenzymes of leukocytes are band 4 and band 2B, and only ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lam WK,Yam LT,Wilbur HJ,Taft E,Li CY

    更新日期:1979-07-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Serum protein profiles by "high-performance" liquid chromatography with detection at multiple wavelengths.

    abstract::We have separated serum proteins in only 15 min by high-performance liquid chromatography. The identification of several peaks in the chromatographic profile was greatly aided by the use of multiple-wavelength detection. We have found a good correlation between retention times and electrophoretic mobilities. Serum sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schlabach TD,Abbott SR

    更新日期:1980-09-01 00:00:00

  • Colorimetry of angiotensin-I converting enzyme activity in serum.

    abstract::This simple, accurate, and reproducible colorimetric method for determining the activity of angiotensin-I converting enzyme is based upon colorimetry of the quinoneimine dye produced from the substrate p-hydroxyhippuryl-L-histidyl-L-leucine by action of this enzyme through the following series of reactions. The enzyme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kasahara Y,Ashihara Y

    更新日期:1981-11-01 00:00:00