Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

Abstract:

:With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in the 0.1--2.0 nanomole range. The detection reagent is stable for months and does not become colored. The reagent mixes with the column effluent in an exothermic reaction and allows use of relatively short mixing coils. The analyzer is appropriate for investigating body fluids rapidly and with high sensitivity.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Voelter W,Bauer H

subject

Has Abstract

pub_date

1975-12-01 00:00:00

pages

1882-6

issue

13

eissn

0009-9147

issn

1530-8561

journal_volume

21

pub_type

杂志文章
  • Increase in dialyzable calcium associated with therapy with lithium.

    abstract::We measured total and dialyzable calcium concentrations in consecutive sera submitted for routine lithium analysis. Of 98 samples from 61 different individuals, six (6.1%) total calcium results and 32 (33%) dialyzable calcium results were above the respective reference intervals. By comparison, when both total and dia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,McComb RB,Bowers GN Jr

    更新日期:1979-10-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Serum creatine kinase isoenzyme BB is a poor index to the size of various brain lesions.

    abstract::We divided patients with brain lesions into three groups: (a) patients with primary or metastatic brain cancer, (b) brain infarctions, and (c) brain contusion(s). We analyzed each patient's sera for creatine kinase isoenzyme BB (CK-BB), using a monoclonal antibody kit (Impres-BB; International Immunoassay Laboratories...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz JG,Bazan C 3rd,Gage CL,Prihoda TJ,Gillham SL

    更新日期:1989-04-01 00:00:00

  • Chromosomal instability in cell-free DNA is a serum biomarker for prostate cancer.

    abstract:BACKGROUND:Genomic instability resulting in copy number variation is a hallmark of malignant transformation and may be identified through massive parallel sequencing. Tumor-specific cell free DNA (cfDNA) present in serum and plasma provides a real-time, easily accessible surrogate. METHODS:DNA was extracted from serum...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.226571

    authors: Schütz E,Akbari MR,Beck J,Urnovitz H,Zhang WW,Bornemann-Kolatzki K,Mitchell WM,Nam RK,Narod SA

    更新日期:2015-01-01 00:00:00

  • Carboxyhemoglobin, cotinine, and thiocyanate assay compared for distinguishing smokers from non-smokers.

    abstract::We compared cotinine, carboxyhemoglobin, and thiocyanate concentrations in blood sampled from 187 cigarette smokers and 181 non-smokers. All three differed significantly between smokers and non-smokers. Cotinine performed best as a test for assessing smoking status, with a sensitivity of 98% as compared with 94% for c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pojer R,Whitfield JB,Poulos V,Eckhard IF,Richmond R,Hensley WJ

    更新日期:1984-08-01 00:00:00

  • Flow-injection analysis with chemiluminescence detection.

    abstract::In "flow-injection analysis," the sample is inserted into a stream of reagent by use of a sample-injection valve. Mixing occurs downstream from the valve in a coil of tubing. With chemiluminescence detection this coil is positioned in front of a photomultiplier. We have evaluated the system for detection of hydrogen p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rule G,Seitz WR

    更新日期:1979-09-01 00:00:00

  • Determination of 5-hydroxytryptophan in plasma by high-performance liquid chromatography and fluorometric detection after phthaldialdehyde reaction.

    abstract::We describe the sensitive and precise determination 5-hydroxytryptophan in plasma from patients treated with this compound. The method is based on solvent extraction of plasma, high-performance liquid chromatography and continuous fluorometric detection after reaction with phthaldialdehyde in strong acid. The combined...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Enbaek F,Magnussen I

    更新日期:1978-02-01 00:00:00

  • Differential reactivity of two homogeneous LDL-cholesterol methods to LDL and VLDL subfractions, as demonstrated by ultracentrifugation and HPLC.

    abstract:BACKGROUND:The analytical and clinical performance of homogeneous LDL-cholesterol assays has been reported, but their reactions with subfractions of LDL and VLDL have not been described in detail. METHODS:We evaluated reaction selectivity of two homogeneous LDL-cholesterol assays, LDLk (Kyowa Medex) and LDLd (Daiichi ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Usui S,Kakuuchi H,Okamoto M,Mizukami Y,Okazaki M

    更新日期:2002-11-01 00:00:00

  • Differential gene expression of Eph receptors and ephrins in benign human tissues and cancers.

    abstract:BACKGROUND:Eph receptors and their ligands, the ephrins, represent a large class of cell-cell communication molecules with well-defined developmental functions. Their role in healthy adult tissues and in human disease is still largely unknown, although diverse roles in carcinogenesis have been postulated. METHODS:We e...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026849

    authors: Hafner C,Schmitz G,Meyer S,Bataille F,Hau P,Langmann T,Dietmaier W,Landthaler M,Vogt T

    更新日期:2004-03-01 00:00:00

  • Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry.

    abstract::A new method for quantifying specific amino acids in small volumes of plasma and whole blood has been developed. Based on isotope-dilution tandem mass spectrometry, the method takes only a few minutes to perform and requires minimal sample preparation. The accurate assay of both phenylalanine and tyrosine in dried blo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chace DH,Millington DS,Terada N,Kahler SG,Roe CR,Hofman LF

    更新日期:1993-01-01 00:00:00

  • Effect of daylight on the reaction of thiols with Ellman's reagent, 5,5'-dithiobis(2-nitrobenzoic acid).

    abstract::The reaction of 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB, Ellman's reagent) with thiols is sensitive to daylight, in particular to ultraviolet radiation at wavelengths around 325 nm. Exposure to light at the absorbance maximum of the yellow product (the thionitrobenzoate ion) at 410 nm had no effect on the reaction. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walmsley TA,Abernethy MH,Fitzgerald HP

    更新日期:1987-10-01 00:00:00

  • 25-Hydroxyvitamin D and Risk of Osteoporotic Fractures: Mendelian Randomization Analysis in 2 Large Population-Based Cohorts.

    abstract:BACKGROUND:Whether low plasma 25-hydroxyvitamin D concentrations cause osteoporotic fractures is unclear. We tested the hypothesis that low plasma 25-hydroxyvitamin D concentrations are associated with increased risk of osteoporotic fractures using a Mendelian randomization analysis. METHODS:We genotyped 116 335 rando...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa049

    authors: Çolak Y,Afzal S,Nordestgaard BG

    更新日期:2020-05-01 00:00:00

  • Concepts for the rational selection of assays to be used in monitoring therapeutic drugs.

    abstract::As the domain of monitoring therapeutic drugs rapidly expands from experimental investigations to everyday patient care, all clinical laboratory scientists, but especially clinical chemists, must learn to deal with their involvement in this expansion. First, the theoretical concepts underlying clinical pharmacology mu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Werner M,Sutherland EW 3rd,Abramson FP

    更新日期:1975-09-01 00:00:00

  • Cross reactions in radioimmunoassay: a mathematical model for correcting assay results, as exemplified by eliminating the interference of intact thyrotropin in an assay of its beta subunit.

    abstract::To correct the results of a radioimmunoassay for beta-thyrotropin (TSH) subunit by eliminating the proportion ascribable to intact TSH, we have devised a method that experimentally reproduces the conditions under which the interference develops. Beta-TSH subunit was assayed in several preparations containing known con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dotti C,Ceda GP,Denti L,Cavalieri S,Borasi G,Valenti G

    更新日期:1987-05-01 00:00:00

  • Simultaneous quantitation of zinc protoporphyrin and free protoporphyrin in erythrocytes by acetone extraction.

    abstract::Erythrocyte protoporphyrin content is increased in several human and veterinary disorders in which heme synthesis is disrupted. The nature of the defect determines whether zinc protoporphyrin, unchelated (free) protoporphyrin, or both are present in the erythrocytes. Extraction of the protoporphyrin into acetone/water...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hart D,Piomelli S

    更新日期:1981-02-01 00:00:00

  • Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

    abstract::We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-star...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de Rijke D,Kreutzer HJ

    更新日期:1983-06-01 00:00:00

  • Nonchromatographic radioimmunoassay of unconjugated estriol in plasma, with polyethylene glycol as precipitant.

    abstract::We describe a rapid, reliable radioimmunoassay for unconjugated estriol in plasma. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay is sensitive (25 pg for standards), precise, and accurate. At high and low concentrations of estriol, intra-assay coefficients of variati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schiller HS,Brammall MA

    更新日期:1976-03-01 00:00:00

  • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures.

    abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.173856

    authors: Hoofnagle AN,Becker JO,Oda MN,Cavigiolio G,Mayer P,Vaisar T

    更新日期:2012-04-01 00:00:00

  • The hybridoma-an immunochemical laser.

    abstract::The advent of hybridoma technology has provided the immunotechnologist a finely tunable instrument that should permit a marked advance in the immunologic sciences. The ability to choose the precise antibody required and the virtually unlimited availability of easily purified antibodies have already resulted in the sim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: David GS,Wang R,Bartholomew R,Sevier ED,Adams TH,Greene HE

    更新日期:1981-09-01 00:00:00

  • Extracellular Vesicles Long RNA Sequencing Reveals Abundant mRNA, circRNA, and lncRNA in Human Blood as Potential Biomarkers for Cancer Diagnosis.

    abstract:BACKGROUND:Extracellular vesicles (EVs) contain a rich cargo of different RNA species with specialized functions and clinical applications. However, the landscape and characteristics of extracellular vesicle long RNA (exLR) in human blood remain largely unknown. METHODS:We presented an optimized strategy for exLR sequ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.301291

    authors: Li Y,Zhao J,Yu S,Wang Z,He X,Su Y,Guo T,Sheng H,Chen J,Zheng Q,Li Y,Guo W,Cai X,Shi G,Wu J,Wang L,Wang P,He X,Huang S

    更新日期:2019-06-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Diet-related reference values for plasma amino acids in newborns measured by reversed-phase HPLC.

    abstract::We have measured by reversed-phase HPLC concentrations of amino acids in plasma in groups of 80 normal appropriate-weight term babies fed from birth either a casein formula (WhiteCap SMA, n = 26), a whey formula (Gold Cap SMA, n = 26), or breast milk (n = 28). They were studied from day 11 to week 15 postpartum. The t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Scott PH,Sandham S,Balmer SE,Wharton BA

    更新日期:1990-11-01 00:00:00

  • Plasma microRNA-122 as a biomarker for viral-, alcohol-, and chemical-related hepatic diseases.

    abstract:BACKGROUND:The liver is frequently subject to insult because of viral infection, alcohol abuse, or toxic chemical exposure. Extensive research has been conducted to identify blood markers that can better discern liver damage, but little progress has been achieved in clinical practice. Recently, circulating microRNAs (m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.147850

    authors: Zhang Y,Jia Y,Zheng R,Guo Y,Wang Y,Guo H,Fei M,Sun S

    更新日期:2010-12-01 00:00:00

  • Abnormal composition of apoproteins C-I, C-II, and C-III in plasma and very-low-density lipoproteins of non-insulin-dependent diabetic Chinese.

    abstract::Apoprotein (apo) C-I, C-II, and C-III were measured in plasma from 35 white American non-diabetic subjects. The mean concentrations (mg/L) in plasma from normolipidemic and hypertriglyceridemic subjects, respectively, were apo C-I, 78 and 311; apo C-II, 37 and 200; and apo C-III, 98 and 529. These concentrations were ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pan XR,Cheung MC,Walden CE,Hu SX,Bierman EL,Albers JJ

    更新日期:1986-10-01 00:00:00

  • Seasonal and sex variation of high-sensitivity C-reactive protein in healthy adults: a longitudinal study.

    abstract:BACKGROUND:Cross-sectional studies have reported seasonal variation in high-sensitivity C-reactive protein (hsCRP). However, longitudinal data are lacking. METHODS:We collected data on diet, physical activity, psychosocial factors, physiology, and anthropometric measurements from 534 healthy adults (mean age 48 years,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111245

    authors: Chiriboga DE,Ma Y,Li W,Stanek EJ 3rd,Hébert JR,Merriam PA,Rawson ES,Ockene IS

    更新日期:2009-02-01 00:00:00

  • "Sandwich" enzyme immunoassay for serum ferritin with polypropylene test tubes as the solid phase.

    abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Revenant MC

    更新日期:1983-04-01 00:00:00

  • Troponin I in patients without chest pain.

    abstract:BACKGROUND:Testing for troponin has important clinical value for patients who present with typical symptoms of acute coronary syndromes (ACS) such as chest pain (CP). Much less is known about the value of troponin testing for patients who present with other symptoms of ACS (anginal equivalent symptoms). METHODS:The ut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.016311

    authors: Ritter D,Lee PA,Taylor JF,Hsu L,Cohen JD,Chung HD,Virgo KS

    更新日期:2004-01-01 00:00:00

  • Cobalamin-binding capacity of haptocorrin and transcobalamin: age-correlated reference intervals and values from patients.

    abstract::Unsaturated cobalamin-binding capacity in plasma (P-UBBC) is determined by use of a silica gel (QUSO G32) to separate haptocorrin (P-ApoHC) and transcobalamin (P-ApoTC). The method is sensitive and precise: detection limit 13 pmol/L, interassay coefficients of variation 3% for P-UBBC (mean = 1080 pmol/L), 4% for P-Apo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gimsing P,Nexø E

    更新日期:1989-07-01 00:00:00

  • Determination of vanillylmandelic acid with ion-pair chromatography and fluorescence detection.

    abstract::We describe a chromatographic procedure for sensitive (2.0 mumol/L), specific quantification of vanillylmandelic acid (VMA) in urine with iso-VMA as an internal standard. After rapid extraction from urine, the VMA is determined by isocratic reversed-phase ion-pair chromatography on a bonded C8 column and detection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindgren K,Rodopoulos N

    更新日期:1986-04-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00